DHL_EN_50Hz Electronic Circulators For Heating Systems
PERFORMANCE RANGE
- Flow rate up to 3.5 m3/h (0.97 l/s)
- Head up to 6 m
INSTALLATION AND USE
Energy-efficient, class A electronic circulators significantly reduce electricity use by up to 85% compared to traditional models with similar performance, making them an ideal choice for home and residential heating systems. These circulators feature advanced control electronics that allow for customizable functionality to meet the specific needs of various systems. Users can easily adjust and select the desired operating program directly from the electrical panel’s controller, enhancing system efficiency and comfort by minimizing energy consumption and reducing water flow noise in pipes, valves, and radiators. For optimal perfor-mance, installation should be in well- ventilated, enclosed spaces or areas protected from the elements.
APPLICATION LIMITS
- Liquid temperature between +2 °C and +95 °C
- Ambient temperature between 0 °C and +40 °C
- Maximum working pressure = 6 bar.
- Minimum suction pressure:
- 0.3 bar to 50 °C
- 1.0 bar to 95 °C
- Maximum relative humidity ≤ 95%.
- Sound pressure level < 43 db(A)
- Glycol maximum 30%
- Continuous running duty S1
COMPONENTS
OPERATING MODE
The electrical panel enables users to select the optimal working curve for the circulator through three distinct programs. A bright LED indicator displays the circulator’s operating status, with variations in illumination providing clear, at-a-glance information.
PROPORTIONAL PROGRAM
GREEN LED
This setting proportionally adjusts the pressure (head) based on the system’s
heat demand and desired flow rate
CONSTANT PROGRAM
ORANGE LED
This setting maintains a constant pressure level (head) according on the
system’s heat demand and desired flow rate.
CUSTOMISED PROGRAM
LED BLU
Allows the pump’s speed to be set to a constant level, adjustable through a
selector that can be positioned between the MIN and MAX settings to fine-tune
performance.
An LED indicator on the electrical panel alerts users to the potential presence of air in the system. Should this occur, the circulator’s onboard electronics automatically engage a mo-tor unlocking feature to resolve the issue.
-
WHITE LED
Presence of air in the system. Bleed the system -
RED LED
The circulator is in a locked state but is still under power
DIMENSIONS AND WEIGHT
TYPE
Single- phase
| PORTS| DIMENSIONS mm| kg
---|---|---|---
DN1| DN2| h| a1| a2| b1| b2
DHL 25-60/130| G 1½| G 1½| 130|
45
|
45
|
29
|
104.2
| 2.01
DHL 25-60/180| 180| 2.60
PERFORMANCE CURVES