Jandy TrueClear Salt Chlorinators User Guide

July 17, 2024
Jandy

Jandy-TrueClear-Salt-Chlorinators-logo

Jandy TrueClear Salt Chlorinators

Product Information

Specifications

  • Model: TruClear11K / TruClear11KU
  • Recommended Pool Size: Up to 35,000 gallons
  • Salt Range: 3,000 – 6,000 PPM
  • Voltage: 120 / 240 VAC
  • Flow Sensing: Gas Trap

Product Usage Instructions

Installation
Step 1: Cut plumbing as indicated in the manual.
Step 2: Glue in the specified unions or couplings as directed.
Step 3: Secure the TruClear unit in the correct orientation with the viewing window facing up.
Step 4: Ensure the flow indicator arrows on the housing align with the water flow direction.

Maintenance
To clean the cell:

  1. Remove the cell from the system.
  2. Dip the cell into a cleaning solution to remove any build-up.
  3. Monitor the transparent viewing window to determine when cleaning is required.

Parts Replacement
If parts need replacement, refer to the provided part numbers for compatible replacements. Follow the manufacturer’s recommendations for part compatibility.

Suggested Tools
Ensure you have the necessary tools on hand, such as cutting tools, glue for plumbing, and any specified unions or couplings.

FAQ

  1. Q: Can I use TruClear with a pool larger than 35,000 gallons?
    A: TruClear is recommended for pools up to 35,000 gallons. For larger pools, consider consulting with a pool professional for guidance.

  2. Q: How often should I clean the TruClear cell?
    A: The frequency of cleaning will depend on usage and environmental factors. Monitor the viewing window regularly and clean the cell when buildup is visible.

  3. Q: Do I need to winterize the TruClear unit?
    A: The Winterizing Cap provided with the unit allows for easy winterization. Follow the manufacturer’s instructions for proper winterizing procedures.

Why TruClear® is the best option to replace or add a salt chlorinator

Clear Viewing Window
Don’t guess and check when cells need to be cleaned! Transparent window allows for easy visual inspection of blades, so you know when it needs to be cleaned.

Easiest to Clean
No need to unscrew unions, buy extra parts or be cautious of electronics — just remove the cell and dip the whole thing into the cleaning solution.

Jandy-TrueClear-Salt-Chlorinators-\(3\)

Made for Multitasking
Because the cell body stays in place when cleaning the cell, you can still run the system to continue servicing as needed — simply unscrew the cell and screw on the cap.

Make the Right Connections
Whether the existing setup is wired for 115V or 230V, TruClear® is easy to connect with dual voltage capabilities.

Simple to Situate
Need to replace a Salt Chlorinator? TruClear® requires minimal horizontal plumbing, allowing for easy installation on virtually any pad.

Suggested Tools

  • 2″ PVC Pipe Cutter & deburring tool
  • PVC primer and heavy duty gray cement
  • Pen or Marker
  • Towel for clean up
  • Power Drill and a 6mm (15/64″) drill bit
  • Phillips Screwdriver or bit
  • Multimeter to confirm proper voltage
  • 12 AWG wire Red/Black/Green

Jandy-TrueClear-Salt-Chlorinators-\(5\)

Note: TruClear works with pools of up to 35,000 gallons

Jandy® TruClear® Replacement Parts

Jandy-TrueClear-Salt-Chlorinators-\(6\)

New replacement parts for TruClear are backwards compatible:
R0802200 replaces R0663700; R0802300 replaces R0663900; R0802400 replaces R0609700.
NOTE: When replacing transformer R0609700 with the new Dual Voltage/RS485 transformer R0802400, we also recommend changing to the new Dual Voltage/RS485 PCB R0802300.

How TruClear® 11KU fits

(Replacing Pentair® Intellichlor®)

Jandy-TrueClear-Salt-Chlorinators-\(7\)

NOTE: Fluidra equipment must be installed and serviced by qualified or licensed pool professionals. Please see the installation manual for complete step-by-step instructions.

How TruClear® 11KU fits
(Replacing Pentair® Intellichlor®)

Jandy-TrueClear-Salt-Chlorinators-\(8\)

How TruClear® 11K fits

(Replacing Hayward® T-Cell 15®)

Jandy-TrueClear-Salt-Chlorinators-\(9\)

NOTE: Fluidra equipment must be installed and serviced by qualified or licensed pool professionals. Please see the installation manual for complete step-by-step instructions.

How TruClear® 11K fits
(Replacing Hayward® T-Cell 15®)

Jandy-TrueClear-Salt-Chlorinators-\(10\)

How TruClear® 11KU fits

(Replacing Hayward T-Cell 15)

Jandy-TrueClear-Salt-Chlorinators-\(11\)

Jandy-TrueClear-Salt-Chlorinators-\(12\)

Competitor Matrix

BRAND| DESCRIPTION| PART NUMBER| RECOMMENDED GALLONAGE| SALT RANGE (PPM)| VOLTAGE| PIPE SIZE| FLOW SENSING
---|---|---|---|---|---|---|---
Jandy®| TruClear®| TRUCLEAR11KU| 35,000| 3,000 – 6,000| 120 / 240 VAC| 2″| Gas Trap
Jandy| TruClear| TRUCLEAR11K| 35,000| 3,000 – 6,000|

120 / 240 VAC

| 2″| Gas Trap

REPLACE THE FOLLOWING WITH JANDY TRUCLEAR11KU:

Hayward®| AquaRite T-3| AQR3 / AQR915| 15,000| 2,700 – 3,400| 120 / 240 VAC| 2″          External Flow Switch
Hayward| AquaRite T-9| AQR9 / AQR925| 25,000| 2,700 – 3,400| 120 / 240 VAC| 2″ External Flow Switch
Hayward| AquaRite T-15| AQR15 / AQR940| 40,000| 2,700 – 3,400| 120 / 240 VAC| 2″          External Flow Switch
Hayward| AquaRite S315| AQRS315| 15,000| 1,200 – 8,000| 115 / 230 VAC| 2″ External Flow Switch
Hayward| AquaRite S325| AQRS325| 25,000| 1,200 – 8,000| 115 / 230 VAC| 2″ External Flow Switch
Hayward| AquaRite S340| AQRS340| 40,000| 1,200 – 8,000| 115 / 230 VAC| 2″ External Flow Switch
Pentair®| IntelliChlor® IC20| 520556 + 520554| 20,000| 3,600 – 4,500| 120 / 240 VAC| 2″          External Flow Switch
Pentair| IntelliChlor IC40| 520556 + 520555| 40,000| 3,600 – 4,500| 120 / 240 VAC| 2″          External Flow

NOTE: TruClear works with pools of up to 35,000 gallons

BRAND| DESCRIPTION| PART NUMBER| RECOMMENDED
GALLONAGE| SALT RANGE
(PPM)| VOLTAGE| PIPE SIZE          FLOW SENSING
---|---|---|---|---|---|---
Pentair®| iChlor15| 523080| 15,000| 3,000 – 6,000| 120 / 240 VAC| 2″ Integrated Flow Switch
Pentair| iChlor30| 523081| 30,000| 3,000 – 6,000| 120 / 240 VAC| 2″ Integrated Flow Switch
AutoPilot®| Digital Nano®| DN1 / DN2| 28,000| 3,000 – 35,000| 120 / 240 VAC| 2″          External Flow Switch
AutoPilot| Digital Nano+®| DNP2| 32,000| 3,000 – 35,000| 120 / 240 VAC| 2″ External Flow Switch
AutoPilot| Eco Nano®| EN2| 25,000| 3,000 – 35,000| 120 / 240 VAC| 2″ External Flow Switch
AutoPilot| Digital®| PPM1| 40,000| 3,000 – 35,000| 120 / 240 VAC| 2″ External Flow Switch
Solaxx®| PureChlor 15K| CLG115A| 15,000| 3,500 – 4,500| 120 / 240 VAC| 2″ Integrated Flow Switch
Solaxx| PureChlor 25K| CLG125A| 25,000| 3,500 – 4,500| 120 / 240 VAC| 2″ Integrated Flow Switch
Solaxx
Solaxx| PureChlor 40K
Resilience E| CLG140A
E40| 40,000
40,000| 3,500 – 4,500
500 – 6,000| 120 / 240 VAC
110 / 240 VAC| 2″            Integrated Flow Switch
2″            Integrated

A Fluidra Brand | Jandy.ca | 1.800.822.7933
©2024 Fluidra. All rights reserved. The trademarks and trade names used herein are the property of their respective owners. 02197_SA