ELPLAST-B150-1B1(H01) Wall Mounted Energy Recovery Ventilators Owner’s Manual
- July 14, 2024
- ELPLAST
Table of Contents
- ELPLAST-B150-1B1(H01) Wall Mounted Energy Recovery Ventilators
- Product Usage Instructions
- Delivering a healthy indoor environment
- REDUCING THE ELECTRIC BILLS
- WALL MOUNTED ENERGY RECOVERY VENTILATOR
- FEATURES
- FUNCTIONING
- CONTROL
- SCENE CONTROL
- Technical Parameters
- INSTALLATION ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELPLAST-B150-1B1(H01) Wall Mounted Energy Recovery Ventilators
Specifications
- Multiple filters for indoor & outdoor air
- High efficiency heat recovery and humidity recovery
- 99% purification filtration
- High efficiency DC fans
- Remote control
- CO2/PM2.5 monitoring
- Easy installation
Product Usage Instructions
Delivering a Healthy Indoor Environment
This product provides high-efficiency filtration and heat recovery to
create a healthy indoor environment with purified air and controlled humidity
levels.
Reducing Electric Bills
The Energy Recovery Ventilator (ERV) system helps reduce energy costs by
transferring heat between incoming and outgoing air, leading to energy savings
of up to 30% compared to natural ventilation methods.
Summer and Winter Operation
In summer, the ERV cools the warmer supply air using the inside air,
reducing cooling costs. In winter, it transfers heat from the warm inside
exhaust air to the cold outside supply air, cutting heating expenses.
Wall Mounted Energy Recovery Ventilator
This ductless ERV system is designed for residential and commercial use,
providing efficient ventilation without the need for extensive ductwork. It
features SA HEPA and Activated Carbon filters and an enthalpy heat exchange
core with up to 82% efficiency.
Air Filtration
The unit includes primary, F5, HEPA H10, and activated carbon filters for
effective purification. Both primary filters are washable and durable,
reducing maintenance costs.
Fans
The unit utilizes high efficiency DC fans with 8-speed regulation for
balanced air supply and exhaust. The fans ensure a slight positive pressure
indoors to prevent pollutants from entering through gaps
Enthalpy Heat Exchanger
The heat exchanger facilitates heat and humidity recovery for optimal
energy efficiency and indoor comfort.
FAQ
-
Q: How do I monitor CO2 and PM2.5 levels?
A: The product features CO2/PM2.5 monitoring capabilities, which can be accessed through the remote control or a connected device such as a tablet. -
Q: Are the filters included washable?
A: Yes, both primary filters included in the unit are washable and durable for long-term use, reducing maintenance costs.
WALL MOUNTED ENERGY RECOVERY VENTILATOR
Delivering a healthy indoor environment
The indoor air can be many times worse than outdoor air. Exchange your indoor
air with ELPLAST. In the pursuit of keeping our homes insulated and energy
efficient we have also sealed in models, bacteria, fungus, VOCs, allergens,
carbon dioxide and carbon monoxide, all inevitably contributing to the
potential for illness.
Between home, work and school, 90% of our lives are lived indoors. That’s why
the quality of your indoor air is of utmost importance . ELPLAST wall mounted
ductless energy recovery ventilator will remove the indoor polluted air with
ease and provide a constant supply of clean filtered air, allowing you and
your family to live in an ideal indoor environment.
REDUCING THE ELECTRIC BILLS
Struggling with high electricity bills by using the air conditioner and wanna
lower energy bill? Most ventilation systems drive up heating and cooling costs
while decreasing indoor comfort. Much like venting a room by opening a window,
ventilation systems can degrade energy performance because they expel air
without capturing the heat. ERV systems conserve energy, lowering electric
bills.
The ERV reduces the costs of heating ventilated air in the winter by
transferring heat from the warm inside exhaust air to the fresh (but cold)
outside supply air. In the summer, the inside air cools the warmer supply air
to reduce cooling costs.
The heat from the exhaust air is transferred to the incoming air via a heat
exchanger. The heat recovery efficiency is up to 82%. The ERV saves energy up
to 30% compared to natural ventilation. This also helps reduce the size of the
HVAC equipment needed because it doesn’t have to work as hard to heat and cool
when the intake air is conditioned by the ERV unit.
Because the ERV transfers some of the moisture from the exhaust air to the
usually less humid incoming winter air, the humidity of the house air stays
more constant. This also keeps the heat exchanger core warmer, minimizing
problems with freezing.
WALL MOUNTED ENERGY RECOVERY VENTILATOR
DUCTLESS TYPE ENERGY RECOVERY VENTILATOR
The single room ERV is designed for both residential and commercial spaces.
It’s ductless design, suitable for easy and high-efficient ventilation in the
new or retrofitting buildings no need to run ducts anywhere in the room.
FEATURES
- Easy installation for ventilation in single room size 15-50m2.
- Heat recovery efficiency up to 82%.
- Brushless DC motor with low energy consumption, 8 speeds.
- Silent operation noise (22.6-37.9dBA).
- Indoor air quality monitor (humidity + temperature + CO2/PM2.5).
- Supply air purification with primary filter+medium filter+HEPA filter(H10) with activated carbon filter as standard, the PM2.5 purification efficiency is up to 99%.
- Thin and light weight and compact size.
- Two kinds of installation to suit room.
- Slight positive ventilation to ensure fresh air won’t come through doors or windows without purification.
- Smart phone control Android / IOS.
DESIGN
CASING
The casing is integrated with a seamless and leak proof ABS frame made by
molding. It has good quality of high strength, light weight, good insulation,
smooth surface and easy to clean. The upper panel ensures convenient access to
the replacement of HEPA filter and activated carbon filter. The OA primary
filter and medium filter are at the side of the ventilator while RA primary
filter is at the bottom of the unit. The unit has two inlets and outlet spigot
with a diameter of 100mm for fresh air intake and stale air outlet.
AIR FILTRATION
The primary filter, F5 filter, the HEPA H10 filter, and activated carbon
filters are included at the supply air side. The purification efficiency of
PM2.5 is up to 99%. The primary filter is included in the extract air side.
Both primary filters are washable and durable for use for a long time. It can
reduce the maintenance costs of the unit.
FANS
The unit takes advantage of using brush less DC motors and 8-speed regulation
for supply air and exhaust air. freely adjust the air supply volume slightly
larger than the exhaust air volume to form a sight positive pressure in the
room to ensure that no pollutants can penetrate into the gaps such as windows
and doors. The DC motor has strong vibration resistance with lower noise and
smooth operation, good ability and stability.
ENTHALPY HEAT EXCHANGER (heat & humidity recovery)
The model ELPLAST -B150 -1B1 unit is equipped with a crossflow heat exchanger
with enthalpy membrane . Membrane is made of imported pulp by special
processing methods and adding some inorganic materials and fire retardant , to
keep the heat exchange paper thin while maintaining high heat
transmissibility, anti-tear properties, fireproof and keep the corrugated
paper stiff and strong but thin.
Enthalpy heat exchanger was coated with a hygroscopic agent with high
absorption and release ability on the surface. The small particle diameter
water moisture molecule can pass while the bigger particle diameter like
harmful gas or peculiar smell gas molecules can’t pass, to make sure heat
exchanger paper have strong penetrability, good selective ability and air
tightness.
FUNCTIONING
CONTROL
- The unit is equipped with a control panel
- The remote control is supplied as standard Wi-Fi communication
- Controlled by Android or iOS smartphone or tablet
SCENE CONTROL
User can create the scene according to the weather changes, schedule or the device status changes.For example, when the weather shows the outdoor relative humidity is higher than 85%, user can the set the ventilator to stop running, to prevent the outdoor humidity coming inside.On the other hand, users can add devices with Tuya APP to their home screen. For example, they can add all the single room ventilator, exhaust fans or light switches in the APP and control them at their will.
CONTROL PANEL
- The upper left corner is the WIFI connection status.
- The upper right corner of the screen is the clock or timing status.
- The upper central part of the screen is the current indoor CO2 concentration / PM2.5 value.
- The lower left side of the screen is the current room temperature and humidity values.
- The lower right side of the screen is the current operation speed of the device.
- At the bottom of the screen are three adjustable buttons.
- “Auto””Manual””Timing””Sleep””PUREL”” PURE-M” and “PURE-H” are mode indication
APP CONTROL
- Speed change over
- Filter replacement indication
- Alarm indication
- Speed setting
- Timer
- Weekly schedule
- Group control
- Scene control
GROUP CONTROL
The ventilator can create group control at the APP, the quantity is not
limited. User can control all the ventilator in the group easily.
Comprehensive Timely Monitoring, Intelligent
Multiple Purification Modes Switch
Original function of “Pure L”“Pure M””Pure H”, 30mins quick deeply clean
User manual of remote controller Button function introduction:
- Press “on” to turn on the ventilator.
- Press “off” to turn off the ventilator.
- Press “lock” to turn off the display,Re-press again to turn on the display.
- Press “Hour”, “Hour” part at the top right corner of the ventilator screen starts twinkling, then press “+” to increase me, press “-” to decrease me, repress “Hour” bu on to save me and exit.
- Press “Minute”, “Minute” part at the top right corner of the ventilator screen starts twinkling, then press “+” to increase me, press “-” to decrease me, repress “Minute” bu on to save and exit. Remark: During twinkling, if no opera on in 15s, twinkling ends and save setting automatically.
- Except for the status of me adjustment and being shut down, press “+” to change speed range from small to large, press “-” to change air speed range from large to small. Switching to “Manual” mode, the SA indicator flashes, press “+” or “-” to adjust the SA speed. A er completing the SA speed setting, press “Pure H” switch to the air speed selection of EA (Under this state, the “Pure H” bu on is equivalent to the “Mode” bu on), press “+” or “-” to adjust the air speed, a er completing the EA speed setting, press “Pure H” bu on again can exit the speed setting( or automatically exit without ac on for 15s), the air speed of SA and EA will be saved respectively.
- The function of “Sleep” bu on is similar to “Sleep” bu on on ventilator.
- The function of “Auto” bu on is similar to “Auto” bu on on ventilator.
- Timer: Press “Timer”, timer mode starts, me at the top right corner of the machine screen twinkles. Press “+” to increase me and “-” to decrease me in interval of 30 minutes, the longest timing is 8 hours, default timing is 00:00; Repress “Timer” bu on to save and exit timer setting, top right corner of the ventilator displays current me again.
- The function of “PURE L”, “PURE M”, “PURE H” is similar to that on the ventilator.Remark: During twinkling, if no opera on in 15s, twinkling ends and save setting automatically. A er timer setting finished, if repress “Timer” bu on, top right corner of the display shows remaining me for the timer setting, at this me it is ok to set the timer again. To cancel timer function, set the me to 00:00.
For model ELPLAST-B150-1B1(H01), under mode “Auto”, the ERV will adjust supply air volume according to indoor PM2.5 range, corresponding speed as below:
PM2.5 Value | Status | Operational | Speed |
---|---|---|---|
0≤PM2.5≤35 | Excellent | 1 | |
35<PM2.5≤75 | Good | 2 | |
75<PM2.5≤115 | Light Pollution | 4 | |
115<PM2.5≤150 | Medium Pollution | 5 | |
150<PM2.5≤250 | Heavy Pollution | 7 | |
250<PM2.5 | Serious Pollution | 8 |
For model ELPLAST -B150 -1B1(H02), under mode “Auto ”, the ERV will adjust supply air volume according to indoor CO2 range, corresponding speed as below:
CO2 Value | Status | Operational | Speed |
---|---|---|---|
0≤CO2≤450 | Excellent | 1 | |
450<CO2≤1000 | Good | 3 | |
1000<CO2≤1500 | Light Pollution | 5 | |
1500<CO2≤2000 | Medium Pollution | 7 | |
2000<CO2 | Serious Pollution | 8 |
Remark: To ensure sufficient indoor fresh air supply, the speed will rise automatically after model “Auto” runs for some time, 5-10 minutes later it will return to previous speed. During this time, the screen shows different speed from above chart.
Technical Parameters
Model | ELPLAST-B150-1B1(H01) | ELPLAST-B150-1B1(H02) |
---|---|---|
Supply Airflow [m3/h] | 50-150 | |
Voltage [V/50(60)Hz] | 110-240 | |
Max. unit power [W] | 43.8 | |
Max. unit current [A] | 0.37 | |
Sound pressure level at 1.5 m distance [dBA] | 23-36 | |
Transported air temperature [°C] | -15~+40 | |
Casing material | ABS | |
Motor type | DC Type, 8 Speeds | |
Filtration efficiency [%] | 99% HEPA | |
Filtration mode | Pure High, Pure Medium, Pure Low | |
Temperture efficiency [%] | 82 | |
Enthalpy efficiency (Heating) [%] | 58 | |
Enthalpy efficiency (Cooling) [%] | 52 | |
Control | Touch Screen Panel / Remote control | |
Air quality display | PM2.5, Temperature and Retilative Humidity | CO2, |
Temperature and Retilative Humidity
Operational Mode| Manual / Auto / Timer / Sleep
Suitable room size [m2]| 20-45
Dimension [mm]| 450155660
Weight [kg]| 10
Remarks: The equipment has indoor air purification function, under maximum air supply volume of 150 cmh, about 60 cmh of indoor circulating air. It’s helpful to further clean the indoor air and reduce the PM2.5 level.
Ecodesign Information
According to Regulation EU No 1253/2014 of the European Commission,
implementing Directive 2009/125/CE of European Parliament
Model | ELPLAST-B150-1B1(H01) | ELPLAST-B150-1B1(H02) |
---|---|---|
Specific energy consumption (SEC) [kWh/(m2.a)] | Cold | Avera |
-79.28 | A+ | -40.95 |
Type of ventilation unit | Bidirectional | |
Type of drive installed | Eight speed | |
Type of heat recovery system | Recuperative | |
Thermal efficiency of heat recovery [%] | 82% | |
Maximum air flow rate [m3/h] | 150 | |
Power [W] | 43.8 | |
Sound power level [dBA] | 37.9 | |
Reference air flow rate [m3/s] | 0.0417 | |
Reference pressure difference [Pa] | 0 | |
Specific power input (SPI) [W/(m3/h)] | 0.292 | |
Control typology | Local demand control | |
Maximum internal leakage rate [%] | 3.5 | |
Maximum external leakage rate [%] | 5 | |
Mixing rate of bidirectional units [%] | 20 | |
Airflow sensitivity at +20Pa and -20Pa | 27 | |
The classification of the indoor/outdoor air tightness [m3/h] | 7 | |
Internet address | www.elplast.com | |
The annual electricity consumption (AEC) [kWh electricity/a] | Cold | Average |
Warm
7.54| 2.16| 1.72
The annual heating saved (AHS) [kWh primary energy/a]| Cold| Average| Warm
89.4| 45.7| 20.66
DIMENSIONS (mm)
INSTALLATION ACCESSORIES
The package has included all the accessories needed for the installation. user don’t need to prepare extra accessories and save costs.
INSTALLATION
Installation at the back
Installation at the side
ELPLAST.COM P.S.A. ul.Konarskiego 20
99-300, Poland
tel. +48 24 2537865
e-mail: info@elplast.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>