ELPLAST YWF Series Axial Fan Instruction Manual

July 12, 2024
ELPLAST

ELPLAST YWF Series Axial Fan

Specifications

  • Model: YWF Series
  • Input Voltage: 230V
  • Frequency: 50Hz
  • Power Range: 40W – 550W
  • Air Flow Rate: 415m3/h – 8452m3/h
  • IP Rating: 54
  • Noise Level: 46dBA – 72dBA
  • Speed Range: 1300RPM – 2500RPM
  • Operating Temperature: -30°C to 60°C
  • Model Variants: G and B series

Product Usage Instructions

Application
The YWF fan series is designed for ventilation purposes and can be installed on various devices. Ensure the fan is used within the specified operating ranges mentioned on the nameplate.

Safety
Before operating the fan, always ensure the power supply is turned off to prevent any electrical hazards.

Installation
Follow the installation instructions provided in the user manual. Make sure to mount the fan securely in the desired location as per the guidelines mentioned on the nameplate.

Fan Start
To start the fan, refer to the instructions given on the nameplate. Ensure all connections are secure before turning on the power supply.

Maintenance
Under normal operating conditions, the fan does not require frequent maintenance. However, in extreme conditions, it is recommended to periodically check and clean the rotor blades, as well as the inlet and outlet of the fan. Use common cleaning products for this purpose and avoid using sharp tools that could damage the fan casing.

FAQ

  • Is it safe to operate the fan in high-temperature environments?
    The fan is designed to operate within a temperature range of -30°C to 60°C. Operating the fan within this range ensures safe and efficient performance.

  • How often should I clean the fan for optimal performance?
    Under normal conditions, the fan does not require frequent cleaning. However, in extreme conditions, it is advisable to periodically check and clean the rotor blades and fan inlet/outlet to maintain optimal performance.

Technical data

MODEL [V] [Hz] [W] [m3/h] [IP] [dBA] [RPM] [◦C]

  • YWF-2E-200S-

  • 92/15G 230 50 55 780 54 52 2500 -30 ̴ 60

  • YWF-2E-250S-

  • 92/25G 230 50 90 1495 54 60 2400 -30~60

  • YWF-2E-300S-

  • 92/35G 230 50 145 2330 54 62 2300 -30 ̴ 60

  • YWF-4E-200S-

  • 92/15G 230 50 40 415 54 46 1400 -30 ̴ 60

  • YWF-4E-250S-

  • 92/25G 230 50 50 829 54 55 1380 -30 ̴ 60

  • YWF-4E-300S-

  • 92/35G 230 50 85 1887 54 60 1380 -30 ̴ 60
    YWF-4E-350S-

  • 102/34G 230 50 129 2450 54 64 1400 -30 ̴ 60

  • YWF-4E-400S-

  • 102/47G 230 50 180 3544 54 67 1380 -30 ̴ 60

  • YWF-4E-450S-

  • 102/60G 230 50 250 5368 54 69 1350 -30 ̴ 60

  • YWF-2E-200B-

  • 92/15G 230 50 55 780 54 52 2550 -30 ̴ 60

  • YWF-2E-250B-

  • 92/25G 230 50 90 1495 54 60 2400 -30 ̴ 60

  • YWF-2E-300B-

  • 92/35G 230 50 145 2330 54 62 2300 -30 ̴ 60

  • YWF-4E-200B-

  • 92/15G 230 50 40 415 54 46 1400 -30 ̴ 60

  • YWF-4E-250B-

  • 92/25G 230 50 50 829 54 60 1380 -30 ̴ 60

  • YWF-4E-300B-

  • 92/35G 230 50 85 1887 54 60 1380 -30 ̴ 60

  • YWF-4E-350B-

  • 102/34G 230 50 129 2450 54 64 1400 -30 ̴ 60

  • YWF-4E-400B-

  • 102/47G 230 50 180 3544 54 67 1380 -30 ̴ 60

  • YWF-4E- 450B-

  • 102/60G 230 50 250 5368 54 69 1350 -30 ̴ 60

  • YWF-4E-500B-

  • 137/35G 230 50 380 7077 54 71 1320 -30 ̴ 60

  • YWF-4E-550B-

  • 137/50G 230 50 550 8452 54 72 1300 -30 ̴ 60

  • YWF-2E-200B-

  • 92/15B 230 50 55 780 54 52 2500 -30 ̴ 60

  • YWF-2E-250B-

  • 92/25B 230 50 90 1510 54 60 2400 -30 ̴ 60

  • YWF-2E-300B-

  • 92/35B 230 50 145 2330 54 62 2300 -30 ̴ 60

  • YWF-4E-200B-

  • 92/15B 230 50 40 415 54 46 1400 -30 ̴ 60

  • YWF-4E-250B-

  • 92/25B 230 50 50 829 54 60 1380 -30 ̴ 61

  • YWF-4E-300B-

  • 92/35B 230 50 75 1887 54 60 1400 -30 ̴ 60

  • YWF-4E-350B-

  • 102/34B 230 50 129 2450 54 64 1400 -30 ̴ 61

  • YWF-4E-350B-

  • 102/47B 230 50 165 2961 54 65 1420 -30 ̴ 60

  • YWF-4E-400B-

  • 102/47B 230 50 180 3544 54 67 1380 -30 ̴ 61

  • YWF-4E-450B-

  • 102/60B 230 50 250 5368 54 69 1350 -30 ̴ 60

  • YWF-4E-500B-

  • 137/35B 230 50 380 7077 54 71 1320 -30 ̴ 61

User instruction

  • YWF-2E-200S-92/15G
  • YWF-2E-250S-92/25G
  • YWF-2E-300S-92/35G
  • YWF-4E-200S-92/15G
  • YWF-4E-250S-92/25G
  • YWF-4E-300S-92/35G
  • YWF-4E-350S-102/34G
  • YWF-4E-400S-102/47G
  • YWF-4E-450S-102/60G
  • YWF-2E-200B-92/15G
  • YWF-2E-250B-92/25G
  • YWF-2E-300B-92/35G
  • YWF-4E-200B-92/15G
  • YWF-4E-250B-92/25G
  • YWF-4E-300B-92/35G
  • YWF-4E-350B-102/34G
  • YWF-4E-400B-102/47G
  • YWF-4E- 450B-102/60G
  • YWF-4E-500B-137/35G
  • YWF-4E-550B-137/50G
  • YWF-2E-200B-92/15B
  • YWF-2E-250B-92/25B
  • YWF-2E-300B-92/35B
  • YWF-4E-200B-92/15B
  • YWF-4E-250B-92/25B
  • YWF-4E-300B-92/35B
  • YWF-4E-350B-102/34B
  • YWF-4E-350B-102/47B
  • YWF-4E-400B-102/47B
  • YWF-4E-450B-102/60B
  • YWF-4E-500B-137/35B

EU / GUARANTEE CONDITIONS

  • The producer grants a guarantee for a failure-free operation of the fan.
  • The guarantee period is 24 months from the sale date.
  • This Guarantee Certificate is valid only with a receipt confirming the date of purchase.
  • Claims under this guarantee should be made through the authorized dealer.
  • The costs between of carriage to the dealer shall be borne by the pur- chaser.
  • The producer shall not be liable for mechanical damage or when the purchaser makes any construction changes in the product.

Information for Users on Disposal of Old Equipment. This symbol indicates that the electrical and electronic equipment should not be disposed of as general household waste at its end-of-life. Instead, the products should be handed over to the appliance collection points for the recycling of electrical and electronic equipment., recovery and recycling in accordance with your national legislation and the Directive 2002/96/EC and 2006/66/EC.

APPLICATION

Fan series: YWF are intended for use in ventilation and can be used for installation on other devices. The fan should only be used for its intended purpose in the ranges specified by the nameplate! The fan can not work in the room where the conditions may cause corrosion or explosion.

  • The equipment is not intended for use by the persons (including children) with reduced physical, sensory or mental abilities.
  • The equipment is not designed for children to play.

SAFETY

  • All measures should be taken to secure the rotor. It could not be accidentally touched.
  • The installer is responsible for wiring and electrical installations
  • Connections to the mains may only be done by the person authorized to operate the electrical system, after having turned off the power supply.

INSTALLATION

  • Installation should be carried out according to the documentation made by the person authorized to do so.
  • Electrical connections must be made in accordance with applicable regulations according to the wiring diagram located in the connection box or at the fan casing.
  • The casing should adjust evenly to the mounting plane to avoid distortion.
  • Appropriate measures should be taken to prevent reverse gas flow into the room with an open flue or other devices with open flames.
  • For the fans connected to the network permanently electrical installation must contain a circuit breaker in which the distance between the contacts of all poles shall be not less than 3mm.

FAN START

  • Check the correctness of installation
  • Check that the fan is protected from accidental contact with blades.
  • Check that all unwanted objects are removed from the interior
  • Check for leaks in the junction box and connection cable
  • Check that the power consumption shall not exceed the level stated on the nameplate

MAINTENANCE

Under normal operating conditions, the fans do not require maintenance. If you use fans in extreme conditions it is necessary to periodically check and clean the rotor blades and inlet and outlet of the fan. To clean the fan used commonly available cleaning products! Do not use sharp tools that may scratch the surface of the fan casing.

NOTE: All maintenance work can be made only after disconnecting the fan from the power supply.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>