GIRA 2045 00 Mermbach Industrial Area Instruction Manual

July 14, 2024
GIRA

GIRA 2045 00 Mermbach Industrial Area

Specifications:

  • Model: Gira Eco 2045 00
  • Connection: KNX
  • External Power Supply Connection
  • Programming Button
  • LED Programming Indicator
  • RUN/DIAG Application Status Indicator
  • KNX/TP Communication
  • Modbus Connection
  • Network Connection: 2 x RJ45 Sockets
  • MicroSD Card Slot

Product Usage Instructions

Safety Notes:

Only qualified electricians should install and mount electrical devices to prevent damage, fire, or other hazards. The installation guide must be followed at all times.

Device Design:

The Gira Eco device features a programming button, KNX connection, external power supply connection, LED programming indicator, and RUN/DIAG application status indicator. It also includes KNX/TP communication, a release lever for top-hat rail terminal, Modbus connection, network connection with two RJ45 sockets, and a microSD card slot.

Function:

The Gira Eco serves as a gateway to integrate compatible external devices into the KNX system. For specific functions and proper usage details, refer to the product manual available on the product page of www.gira.de.

Information for Qualified Electricians:

For mounting and electrical connections, please refer to the product documentation.

FAQ

What should I do if the LED programming indicator does not light up?

If the LED programming indicator does not light up, check the power supply connection and the device’s programming settings. Ensure that the device is properly connected and powered.

How do I reset the device to its factory settings?

To reset the device to factory settings, press and hold the programming button for 10 seconds until the LED indicators flash. Release the button and wait for the device to restart.

Safety notes

Only qualified electricians may install and mount electrical. Failure to ob- serve the installation guide can result in damage to the device, fire or other dangers. This installation guide is an integral part of the product and must remain with the customer.

Device design (fig. 1)

GIRA-2045-00-Mermbach-Industrial-Area-FIG-1

  1. Programming button
  2. Connection: KNX
  3. Connection: External power supply
  4. Programming LED
  5. RUN/DIAG = application status indicator
  6. KNX = KNX/TP communication
  7. Release lever for top-hat rail terminal
  8. Connection: Modbus
  9. Network connection: 2 x RJ45 sockets
  10. microSD card slot

Function

System information
This device is a KNX system product and com-plies with the KNX guidelines. Detailed specialist knowledge gained on KNX training courses is re-quired to understand the device. The device’s function depends on the software.
Detailed information about software versions, specific ranges of functions, and the software it-self can be found in the manufacturer’s product database.
KNX-certified ETS software is used to plan, in-stall and commission the device. You will find the product database and technical descriptions on our website at www.gira.de.

Proper use
This gateway serves as an interface to integrate the compatible external device into the KNX sys-tem.
You will find information on specific functions and the proper use in the associated product docu-mentation available on the relevant product page at www.gira.de.

Information for electricians
Mounting and electrical connection

DANGER!
You are at risk of electric shock if you touch live parts in the instal-la- tion area.
Electric shock can cause death. Isolate before working on the device and cover up live parts in the vicinity!

Installation and electrical connection (fig. 1) The device is intended for fixed installation in in-door spaces and dry rooms. The device and the devices connected to it in a network must be in-stalled in the same earthing system.

  • Observe the temperature range.
  • Ensure sufficient cooling.
  • Use protection class II for external power sup-ply.
  • Ensure safe separation between Ethernet, RS485 and mains voltage.
  1. Snap the device onto a top-hat rail according to DIN EN 60715. For the installation position, see Figure 1.
  2. Connect the external power supply to the connection terminal (3). Recommendation: Use white-yellow connection terminal.
  3. Connect KNX line with a red-black bus terminal (2).
  4. Connect RS485 (Modbus) to a 3-pin screw terminal (8).
  5. Establish network connection by inserting RJ45 plug into RJ45 socket (9).

Attaching the cover cap (fig. 2)

GIRA-2045-00-Mermbach-Industrial-Area-FIG-2

A cover cap must be attached to protect the bus connection from dangerous voltages in the connection area.

  1. Route bus line to the rear.
  2.  Attach cover cap over the connection terminals until it engages.

Removing the cover cap (fig. 3)
Press cover cap on the sides and remove.

GIRA-2045-00-Mermbach-Industrial-Area-FIG-3

Commissioning

  1. Briefly press the programming button (1).
    Programming LED (4) lights up.

  2. Assign individual address.
    Programming LED (4) goes out.

  3. Label device with individual address.

  4. Load application software, parameters, etc.

Technical data

  • Rated voltage: DC 24 V to 30 V SELV

  • Power consumption: 2.3 W
    KNX:

  • Connection: Bus connection terminal

  • Medium: TP1, S-Mode

  • Current consumption: typ. 6 mA
    IP:

  • Connection 2x RJ45

  • Communication: Ethernet 10/100 BaseT (10/100 Mbit/s)
    RS485:

  • Connection: screw terminal, 3-pin (GND, A+, B-)

  • Communication: Modbus

  • Data rate: max. 500 kbps

  • Cable length: up to 1200 m

  • Electrical isolation: 3 kV DC

  • Ambient temperature: 0 °C to +45 °C

  • Storage temperature: -25 °C to +70 °C

  • Dimensions: 2 HP (DRA plus)

Disposal

Devices with this symbol must be disposed of separately from unsorted municipal waste. Delete any personal data by executing a factory reset before disposal. Please contact our support team before you send a device back.

Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade).
They will forward the devices to the Gira Service Center.