Rheem 2 Stage Compressor Instructions

July 15, 2024
Rheem

Rheem-logo

Rheem 2 Stage Compressor

Product Information

  • Specifications:
    • Brand: RHEEM
    • Compressor Type: 2 Stage
    • Wiring: Diagram provided
    • Connector Rating: 600VAC
  • Safety Precautions:
    • Before installation, ensure all power sources are switched off and follow proper electrical safety procedures. Use appropriate personal protective equipment.
  • Installation Steps:
    • Ensure all connectors used are rated for 600VAC.
    • Remove all start component connections and wires indicated by a yellow X in the system.
    • Connect Easy Start Black to compressor common (BK) on the contactor using a fork or ring terminal connector.
    • Place Easy Start Orange on the run-capacitor Herm (H) position.
    • Remove compressor run (R) from the contactor and splice it to Easy Start Brown.
    • Connect Easy Start White to the contactor.
  • Additional Information:
    • The DFC circled in purple is a defrost board, not a compressor monitoring board. No adjustments are needed for Easy Start settings on this board.

FAQs

  • Q: What should I do if I encounter a yellow X in my system?
    • A: Remove all start component connections and wires indicated by the yellow X before proceeding with the Easy Start installation.
  • Q: Can Easy Start settings be adjusted on the DFC defrost board?
    • A: No, the DFC board is specifically for defrost purposes and does not require any adjustments for Easy Start settings.

WIRING DIAGRAM

RHEEM 2-STAGE COMPRESSOR WIRING DIAGRAM

Rheem-2-Stage-Compressor-fig-1

Product Usage Instructions

  1. Before Easy Start installaƟon!
    • All connectors used must be 600VAC rated!
    • If present in your system all start component connections and wires need to be removed where you see a yellow X
  2. Put Easy Start Black with compressor common (BK) on the contactor behind the screwhead using a fork or ring terminal connector.
  3. Put Easy Start Orange on the run-capacitor Herm (H) posiƟon.
  4. Remove compressor run (R) from the contactor [see red X] and Splice to Easy Start Brown.
    • NOTE: The wire between the contactor and the run-capacitor common remains untouched and unused, and nothing is connected at either end!
  5. Where you removed the last connecƟon Put Easy Start White on the contactor behind the screwhead using a fork or ring terminal connector.
  6. See DFC circled in purple this is a defrost board. This is NOT a compressor monitoring board. NO Easy Start seƫngs are adjusted.