BougeRV BV122000 Pure Sine Wave Inverter User Manual
- July 11, 2024
- BougeRV
Table of Contents
- BougeRV BV122000 Pure Sine Wave Inverter
- Product Usage Instructions
- FCC STATEMENT
- Safety Instructions
- Technical After Services
- Appearance And Interface Description
- Installation and Wiring
- App Usage Instructions
- External Display
- Base Specification
- Overload Protection Description
- FAQ
- CONTACT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BougeRV BV122000 Pure Sine Wave Inverter
Product Usage Instructions
- Follow the safety guidelines provided in the manual to prevent accidents.
- Ensure secure connections to avoid electrical hazards.
- Install the inverter following safety precautions to prevent injuries.
- Refer to any additional safety notes mentioned in the manual for safe operation.
- Contact technical support for any post-purchase assistance or service needs.
- Detailed description of the different models BV121000, BV122000, BV123000.
- Follow step-by-step instructions for proper installation of the inverter.
- Properly connect the grounding wire, battery positive and negative wires, and AC equipment according to the manual.
- Download the designated app for controlling the inverter.
- Follow precautions outlined in the manual when using the app for safety reasons.
- Learn how to adjust settings on the external display for optimal performance.
- Detailed specifications of the inverter’s base model.
- Understand the indicators and alarms to monitor the inverter’s operation effectively.
- Information on how the inverter handles overload situations and protection mechanisms.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B
digital device, under Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed and used under the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance 20cm between the radiator & your body
Safety Instructions
- Please follow the safety instructions for operation, the damage caused by not following the safety instructions shall be borne by the individual.
- Please save these instructions
Inverter Safety Information
- Forbidden for non-professionals to disassemble, repair or modify the inverter.
- Do not place the inverter where children can touch it.
- Keep the inverter far away from harsh environments such as damp, greasy, flammable, explosive, or a large amount of dust.
- The AC output of the inverter is a high voltage, please do not touch the wiring.
- Please read the product installation steps to ensure all connections are correct.
- Do not touch it when it working and keep away from materials or materials affected by high temperatures.
- Please do not open the terminal protection cover when the inverter is working.
- Be sure to disconnect the fuse or circuit breaker near the battery and AC output terminals, before installing and adjusting the wiring of the inverter.
- After installation, check whether all cable connections are tight to avoid the danger of heat accumulation due to virtual connections.
- The inverter is off-grid, and the input power supply of the load equipment needs to be confirmed as the only input device, and do not use in parallel with other input AC power to avoid damage.
Connection Security Information
-
The DC voltage must be matched;
Each inverter has a nominal voltage, and the selected battery voltage must be consistent with the nominal DC input voltage of the inverter. For example, a 12V inverter must select a 12V battery. -
The output power of the inverter must be higher than the maximum power of the electrical appliance;
The maximum power of equipment with large starting energy requirements, such as motors and air conditioners, cannot be higher than the output power of the inverter, and an additional power margin is required. -
The positive and negative poles must be wired correctly;
The diameter of the connecting wire must be thick enough, and the length of the connecting wire should be minimized. -
The inverter shell should be properly grounded to avoid personal injury due to leakage.
Installation Safety Instructions
- Before installation, please read this manual carefully and be familiar with the installation steps.
- Be very careful when installing the battery. When installing a lead-acid liquid battery, you should wear protective glasses. Once you come into contact with the battery acid, please rinse it with clean water in time.
- Avoid placing metal objects near the battery to prevent short circuits of the battery.
- Acid gas may be generated when the battery is charged, make sure the surrounding environment is well-ventilated.
- When installing the cabinet, be sure to leave enough space around the inverter for heat dissipation; do not place the inverter and the lead-acid liquid battery together.
- False connection points and corroded wires can cause extreme heat to melt wire insulation, burn surrounding materials, and even cause fire, so make sure that the connectors are tightened, and the wires are fixed by cable ties to avoid loose connectors caused by shaking of the wires during mobile applications.
- When installing outdoors, avoid direct sunlight and rainwater infiltration.
- After the power switch is turned off, there is still high voltage inside the inverter, please do not open or touch the internal components, and related operations can only be performed after the capacitor is fully discharged.
- Please do not install the inverter in harsh environments such as damp, greasy, flammable, explosive, or a large amount of dust.
- It is forbidden to reverse the polarity of the battery input terminal of this product, otherwise, it is easy to damage the equipment or cause unpredictable dangers.
- The AC output is a high voltage, please do not touch the wiring.
- When the fan is working, do not touch it to avoid injury.
- It is necessary to confirm that the inverter is the only input device for the input power of the load equipment, and it is forbidden to use it in parallel with other input AC power sources to avoid damage.
Additional Safety Note
- In order to protect the personal and property safety of users while using this product, the relevant information is provided in the manual and highlighted with the following symbols.
- If you encounter the following symbols in the manual, please read the relevant text carefully.
- WARNING: Indicates a hazard of electric shock which, if not avoided, will result in equipment damage or personal electric shock/injury.
- ATTENTION: Indicates a potential hazard that, if not avoided, could result in equipment damage.
- NOTE: Indicates an important prompt during operation, failure to execute may cause an equipment failure alarm
Technical After Services
BougeRV provides a 1-on-1 solar solution and an 18-month warranty service.
If you have any questions during use, please feel free to contact us
- (US/CA) service@bougerv.com
- (BougeRV Website) support@bougerv.com
- 1-408-656-8402 9:00AM-6:00PM(CST) Mon-Fri
- www.bougerv.com
- 1-669-232-7427
If you could provide the following relevant information to our email before contacting us; we can provide you with technical support solutions faster.
- Voltage of battery.
- Power of electrical appliance etc.
The company does not assume any responsibility for damages caused by the following circumstances.
- Damage caused by improper use or use in an inappropriate place.
- The current, voltage, and power of the load exceed the limit value of the inverter.
- Damage caused by the working environment temperature exceeding the limited working temperature range.
- Unauthorized disassembly and maintenance of the inverter due to arcing, fire, explosion and other accidents caused by failure to follow the inverter logo or manual instructions.
- Force majeure.
Appearance And Interface Description
BV121000
Interface Description
- Positive electrode of battery input
- Negative electrode of Battery input
- Cooling fan
- AC output terminal 1(15A)
- AC output terminal 2(15A)
- ON/OFF switch
- Fault indicator
- Running indicator
- RS485 communication interface
- USB interface
- Input grounding terminal
BV122000
Interface Description
- Positive electrode of battery input
- Negative electrode of Battery input
- Cooling fan
- AC output terminal 1(15A)
- AC output terminal 2(20A)
- ON/OFF switch
- Fault indicator
- Running indicator
- RS485 communication interface
- USB interface
- Input grounding terminal
- AC high power link port
BV123000
Interface Descripti
- Positive electrode of battery input
- Negative electrode of Battery input
- Cooling fan
- AC output terminal 1(15A)
- AC output terminal 2(20A)
- ON/OFF switch
- Fault indicator
- Running indicator
- RS485 communication interface
- USB interface
- Input grounding terminal
- AC high power link port
Installation and Wiring
Installation Steps
- Step 1: Read the user manual carefully.
- Step 2: Determine the installation position and heat dissipation space.
- Determine the installation position (wall-mounted or horizontal installation mode can be used).
- When installing the inverter, ensure that sufficient space is available and the inverter is removed
- At least 200mm (7.9in) space should be left between the tuyere and the intake for air circulation.
- If installed in a closed container, ensure that heat dissipation can be dissipated through the container; otherwise, reduce the amount of heat used.
- Step 3: Connect cables
- The AC device shall be determined according to the continuous output power of the inverter, but the impact power of the AC device. Do not exceed the instantaneous impact power of the inverter. Otherwise, the inverter may be damaged.
- Before wiring, set the inverter switch to OFF state.
- During the wiring process, do not close the circuit breaker or safety, and confirm the lead connection of the electrodes of each component.
- The battery end needs to be installed with insurance, which is selected according to the inverter input rated current of 2-2.5 times.
- Ensure that the safe position is not more than 150mm away from the battery.
- The input has no reverse connection protection. Before connecting the battery cable, ensure that the positive and negative terminals are correctly connected.
Wiring Sequence
Grounding Wire
Battery Positive and Negative Wires
- Input has no reverse connection protection.
- Before connecting the battery cable, ensure that the positive and negative terminals are correctly connected; otherwise, the inverter may be damaged
AC Equipment
- L:Live wire; N:Neutral wire;+:Ground wire
- Please connect the ground wire first, then the fire wire L and zero wire N.
App Usage Instructions
- Built-in Bluetooth communication function can monitor the operation data, fault status and adjust the operation parameters of the controller in real time through mobile APP.
Download
-
Scan the QR code to download the application;
-
Search for “BougeRV” in the APP Store (for IOS devices) or Google Play (for Android devices).
Precautions For Using APP
- Make sure the inverter is turned on before connecting to Bluetooth.
- The Bluetooth function of the mobile phone is available and turned on.
- The GPS function is available and turned on in your phone.
- Android firmware 8.0 and above, or IOS firmware 13.0 and above.
- If you cannot connect to the app, you need to set it up on the external display: press and hold the AC button for 5 seconds, reset bluetooth and then reconnect to the app;
External Display
- Input voltage
- Output frequency
- Output voltage
- Battery power
- Output power
- Working status
- Over temperature protection
- Over-discharge protection
- Overvoltage protection
- Overload protection
- Inverter temperature
- Inverter switch
- AC voltage switch
- Backlight switch
Setting Method
- Inverter switch: Single press [ON/OFF] to switch ON/OFF.
- AC voltage switch:
- Single press [AC] to switch the AC output voltage. (110V/120V,default 120V)
- Press and hold [AC] for more than 5s to reset bluetooth and then reconnect to the app.
- Backlight switch: Single press [Back Light] to control the display backlight switch.
Base Specification
Model | BV121000 | BV122000 |
---|---|---|
Rated output power | 1000W | 2000W |
Peak power | 2000W(1s) 4000W(1s) | |
Output voltage | 110VAC/120VAC(default) | |
Output frequency | 50/60 Hz(default) | |
Rated input voltage | 12VDC | |
The input voltage ranges | 10V-15.5VDC | |
Output waveform | Pure sine wave | |
Maximun output efficiency | >90% | |
Full Load Efficiency | >86% | |
Battery low voltage alarm | 10.5VDC (±0.3V) | |
Over-discharge voltage | 10VDC (±0.3V) | |
Overvoltage | 15.5VDC (±0.3V) | |
Operating ambient temperature range | -40°F~185°F(-40°C~85°C) | |
Storage temperature range | -40°F~176°F(-40°C~80°C) | |
Noise | ≤60dB | |
Communication Port | RS485+Inbuilt Bluetooth | |
Fan start-up temp | ≥113℉(45℃)/≥50% load | |
USB port | 18W*1(5V-3A,9V-2A,12V-1.5A) | |
Protection function | Input over-voltage/ over-discharge protection, output |
overload/short-circuit protection, and inverter overtemperature protection
Output harmonic component(THD)| <3%| <4%
Over-temperature protection recovery| ≤167℉(75℃)| ≤158℉(70℃)
No-load Loss| <0.5A| <0.7A
Over temperature protect| ≥203℉(95℃)| ≥176℉(80℃)
Product size| 12.235.672.96 in| 14.796.653.98 in
Weight| 5.07 lb| 8.6 lb
Model| BV123000
---|---
Rated output power| 3000W
Peak power| 6000W(1s)
Output voltage| 110VAC/120VAC(default)
Output frequency| 50/60 Hz(default)
Rated input voltage| 12VDC
The input voltage ranges| 10V-15.5VDC
Output waveform| Pure sine wave
Maximun output efficiency| >90%
Full Load Efficiency| >86%
Battery low voltage alarm| 10.5VDC (±0.3V)
Over-discharge voltage| 10VDC (±0.3V)
Overvoltage| 15.5VDC (±0.3V)
Operating ambient temperature range| -40°F~185°F(-40°C~85°C)
Storage temperature range| -40°F~176°F(-40°C~80°C)
Noise| ≤60dB
Communication Port| RS485+Inbuilt Bluetooth
Fan start-up temp| ≥113°F(45℃)/≥50% load
USB port| 18W1(5V-3A,9V-2A,12V-1.5A)
Protection function| Input over-voltage/ over-discharge protection, output
overload/short-circuit protection, and inverter overtemperature protection
Output harmonic component(THD)| <5%
Over-temperature protection recovery| ≥176°F(80℃)
No-load Loss| <0.9A
Over temperature protect| ≥203°F(95℃)
Product size| 17.597.94*3.84 in
Weight| 14.3 lb
Indicators And Alarms
Working status| Running indicator Run-blue| Fault
indicator Fault-red| Buzzer
---|---|---|---
Power on| Steady On| Off| No sound
Shut down| Off| Off| No sound
Under-voltage alarm| Steady On| Off| Buzzer sounds 4 times
Under-voltage protection| Steady On| Steady On| Buzzer sounds 4 times
Undervoltage recovery| Steady On| Off| Buzzer sounds 1 time
Overvoltage protection| Steady On| Steady On| The buzzer sounds 3 times
Overvoltage recovery| Steady On| Off| No sound
Short circuit protection| Steady On| Steady On| Buzzer sounds 1 time
Overload protection| Steady On| Steady On| The buzzer sounds 2 times
Over temperature protect| Steady On| Steady On| Buzzer sounds 4 times
Overload Protection Description
BV121000
Load power | Possible duration |
---|---|
120% ≤ Po ≤ 125% | 20s |
125% ≤ Po ≤ 150% | <10s |
Po﹥150% | <5s, Stop output if the AC voltage is less than 90V. |
BV122000
Load power | Possible duration |
---|---|
110% ≤ Po ≤ 115% | 20s |
115% ≤ Po ≤ 130% | <10s |
Po﹥130% | <5s, Stop output if the AC voltage is less than 90V. |
BV123000
Load power | Possible duration |
---|---|
105% ≤ Po ≤ 108% | 20s |
108% ≤ Po ≤ 143% | <10s |
Po﹥143% | <5s, Stop output if the AC voltage is less than 90V. |
RS485 Connection Diagram
| Switch position| Switch position
---|---|---
| 1| RS485A
2| RS485B
3| GND
4| ****
GND
5| +12V
6| SW-EN
Error Code
Error code | Cause of failure | Solution |
---|---|---|
F01 | Parameter configuration fault | Restart the inverter |
F02 | Circuit sampling fault | Check and repair the current sampling circuit and |
restart the inverter.
F03| DC busbar low-voltage| ① Check whether the power tube of the latter stage
is short-circuited.
②Check the front-stage boost circuit or DC line components.
F04| There are other power supplies in the output circuit| Check if there is
any other power source connected to the output wiring.
F05| Inverter output short circuit protection| Check the output wiring and the
load.
F06| Inverter over-current protection| Reduce the load.
F07| Inverter overload protection| Reduce the load.
F08| Inverter overheating protection| ①Check the fan or air duct, and lower
the ambient temperature.
②reduce/turn off the load output, and wait for the inverter to cool down.
F10| Battery over-voltage protection| Check whether the input power supply or
charger is functioning properly.
F11| DC busbar over-voltage| ① Check the input power supply.
② Internal damage to the machine.
F12| Battery low voltage warning| Charge the battery or replace it.
F13| Data read error| Restart the inverter.
Recommended Cable Sizing
PVC copper cable size(AWG/mm )| Ampcaity(A)tested at
194℉
---|---
8(8.37)| 55
6(13.3)| 75
4(21.2)| 95
3(26.7)| 115
2(33.6)| 130
1(42.4)| 145
1/0(53.5)| 170
2/0(67.4)| 195
3/0(85.0)| 225
4/0(107)| 260
FAQ
Q: What should I do if the inverter shows an overload alarm?
A: If the inverter displays an overload alarm, immediately disconnect excessive loads to prevent damage to the equipment.
Q: Can I install the inverter outdoors?
A: The inverter should be installed indoors or in a protected environment to ensure proper operation and longevity.
Q1: When I have some problems in the process of using the inverter, what information can I provide to BougeRV to provide me with technical support faster and better?
A1: Send the following information to the email, ①The connection method of the inverter and battery. ②The voltage and battery type of the battery. ③The display data/app data of the inverter. ④Connection from battery to inverter and inverter to the loads. If the above information can be provided with pictures or videos, BougeRV can provide you with technical support faster.
Q2: Can I use the inverter with a 24 V system?
A2: No. This model can only work with a 12V battery system.
Q3: Can I use this inverter to charge my batteries?
A3: No. The BougeRV 12VDC to 120VAC inverter can only convert DC power to AC power. Please check the BougeRV Pure Sine Wave Inverter Charger.
Q4: How to check the power consumption of this inverter?
A4: This inverter has a built-in Bluetooth module, and parameters can be set and viewed on the mobile APP.
Q5: Why does the inverter suddenly disconnect during work?
A5: 1. The battery voltage is low, start the over-discharge protection, and it can work normally after recharging the battery; 2. Battery overcurrent. Most batteries are discharged at 1C(1C discharge refers to:The max discharge current of a 100AH battery is 100A, and the max discharge current of a 50AH battery is 50A.), and a 1500W electrical appliance connected to a 2000W inverter connected to 12V 100AH will cause overcurrent. Because after connecting a 1500W electrical appliance, the inverter needs to get 500W/12.8V=117.19A>100A from the battery. In this case, the battery will start protection and disconnect from other devices. Connecting batteries in parallel to increase the current can solve this problem. 3. The power of the electrical appliance is greater than the rated output power of the inverter. For example, using the 2000W inverter to carry a 2500W high-power electrical appliance cannot work. At the same time, the inverter can withstand a maximum instantaneous impact power of 4000W. This means that even if the rated power of the electrical appliance is less than 2000W, excessive instantaneous power will cause abnormal operation and even damage the inverter.
CONTACT
- (US/CA) service@bougerv.com
- (BougeRV Website) support@bougerv.com
- 1-408-656-8402 9:00AM-6:00PM(CST) Mon-Fri
- www.bougerv.com
- 1-669-232-7427
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>