OSRAM LUXVANCE Streetlight General Edition Installation Guide

July 8, 2024
OSRAM

OSRAM LUXVANCE Streetlight General Edition

Specifications

Product| H (mm)| W (mm)| L (mm)| Wattage (W)| Installation height (m)| Weight (kg)| Voltage (v)
---|---|---|---|---|---|---|---
LUXVANCE ST GEN 30W| 175| 467| 88| 30W| 6-9| 1.56| 277V
LUXVANCE ST GEN 60W| 221| 564| 88| 60W| 8-11| 2.57| 277V
LUXVANCE ST GEN 80W| 241| 642| 88| 80W| 9-12| 3.05| 277V
LUXVANCE ST GEN 120W| —| —| —| 120W| —| 3.77| 277V
LUXVANCE ST GEN 150W| —| —| —| 150W| —| —| 277V
LUXVANCE ST GEN 180W| —| —| —| 180W| —| —| 277V
LUXVANCE ST GEN 200W| 276| 740| 88| 200W| —| —| 277V
LUXVANCE ST GEN 240W| —| —| —| 240W| —| —| 277V

Product Usage Instructions

Orientation Change:
To change the orientation of the spigot, loosen or remove the bolts securing the shaft.

Lamp Angle Adjustment:
Adjust the angle of the lamp head as desired.

Luminaire Connection:
Ensure the power is switched OFF before proceeding.
Connect the luminaire to the mains using an IP rated terminal.

Lamp Securing:
Secure the lamp by tightening the pole screws to prevent instability.

Frequently Asked Questions

  • Can I replace the light source myself?
    The light source of this luminaire is a non-user-replaceable light source. It should only be replaced by the manufacturer, their service agent, or a qualified person.

  • Are these products suitable for outdoor use?
    Yes, these products are suitable for outdoor use. Please ensure proper installation and grounding for outdoor applications.

  • What should I do if I need service or have further questions?
    For service inquiries or further questions, please contact Haneco Lighting Australia Pty Ltd at the provided contact information.

DIMENSION

LUXVANCE® Street Light General Edition| W

(mm)

| L

(mm)

| H

(mm)

| Wattage (W)| Installation height

(m)

| Weight (kg)| Voltage (v)| IP| IK| ta
---|---|---|---|---|---|---|---|---|---|---
LUXVANCE ST GEN| 175| 467| 88| 30W| 6-9| 1.56| AC120-| 66| 08| 40°C
30W|  |  |  |  |  |  | 277V|  |  |
 |  |  |  |  |  |  | 50Hz/

60Hz

|  |  |
LUXVANCE ST GEN 60W| 60W
LUXVANCE ST GEN| 221| 564| 88| 80W| 8-11| 2.57|  |  |  |
80W|  |  |  |  |  |  |  |  |  |
LUXVANCE ST GEN|  |  |  | 120W|  |  |  |  |  |
120W|  |  |  |  |  |  |  |  |  |
LUXVANCE ST GEN| 241| 642| 88| 150W| 9-12| 3.05|  |  |  |
150W|  |  |  |  |  |  |  |  |  |
LUXVANCE ST GEN|  |  |  | 180W|  |  |  |  |  |
180W|  |  |  |  |  |  |  |  |  |
LUXVANCE ST GEN| 276| 740| 88| 200W|  | 3.77|  |  |  |
200W|  |  |  |  |  |  |  |  |  |
LUXVANCE ST GEN|  |  |  | 240W|  |  |  |  |  |
240W|  |  |  |  |  |  |  |  |  |

INSTALLATION INSTRUCTION

  1. To change orientation of spigot, loosen or remove bolts used to secure the shaft.

  2. Adjust the angle of the lamp head and secure it by tightening the screws.

  3. Ensure that the power is switched OFF. Connect the the luminaire to mains using an IP rated terminal.

  4. Secure the lamp by tightening the pole screws to prevent it from becoming unstable.

  5. Switch power ON and check that the luminaire is operational.

  6. Note: Shorting cap must be attached to fitting to ensure fixture is operational. Shorting cap can be disgarded if PE Cell is utilised.

WARNING

  1. Ensure that any installation and maintenance be performed by a qualified electrician and the luminaire is wired in accordance with the local wiring and relevant Australia standards.
  2. Ensure that the power supply is off before starting installation and maintenance. Do not switch on until the installation or maintenance is completed.
  3. The light source of this luminaire is non-user alternative light source, the light source contained in the luminaire shall only be replaced by the manufacturer of his service agent or a similar qualified person.
  4. Make sure the products are grounded.
  5. Power supply system should be equipped with SPD (Surge Protection Device) accordance with electrical regulations.
  6. The products are suitable for outdoor use.
  7. For luminaires with dimmable LED drivers. reinforce insulation was provided between LV supply and output/dimming circuit.
  8. For NEMA version, make sure to meet the waterproof requirement after installing the short cap or NEMA controller.
  9. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 3m is not expected.
  10. Glass cover was constituted with a glass having a high impact shock resistance.

ABOUT COMPANY

  • Haneco Lighting Australia Pty Ltd
  • 262 Marion Road, Netley, South Australia 5037
  • Haneco.com.au
  • 1300 001 533
  • OSRAM is a trademark of OSRAM GmbH.
  • TRAXON is a licensee of product trademark OSRAM for a fixed list of General Lighting product.
  • Haneco Lighting Australia is a Traxon distributor of OSRAM products in Australia, New Zealand and Pacific Islands.

OSRAM OFFICIAL LICENSEE

  • Traxon Technology Ltd. 213 Wireless Centre,
  • 3 Science Park East Avenue, Science Park, Shatin,
  • New Territories, Hong Kong
  • Phone: +852 2943 3488
  • www.traxon-ecue.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals