PDU3EVSR6G60 14.5kW 200-240V 3PH Switched PDU
14.5kW 200-240V 3PH Switched PDU – LX
Interface, Gigabit, 30 Outlets, IEC 309 60A Blue Input, LCD, 1.8 m Cord, 0U
1.8 m Height, TAA
MODEL NUMBER: PDU3EVSR6G60 14.5kW 3-phase PDU with multi-function touchscreen
LCD distributes, monitors and manages AC power.
Built-in Java-free network interface helps you remotely monitor load levels to
prevent overloads that cause downtime.
Description
The PDU3EVSR6G60 14.5kW 3-Phase Switched Power Distribution Unit provides
advanced network control and remote power monitoring with the ability to turn
on, turn off, reboot or lock out power to each outlet. By reducing the
frequency of on-site visits, these advanced remote capabilities can save you
money and reduce downtime.
The 0U PDU features 30 switched outlets (24 C13 and 6 C19) with included plug-
lock insert sleeves to prevent cables from becoming accidentally disconnected.
A 6-ft. (1.83 m) cord with IEC 309 60A Blue plug onnects the PDU to a
compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full
remote access for PDU status monitoring and email notifications via secure web
browser, SNMP, telnet, SSH, or CLI. It supports 10/100/1000 Mbps auto-sensing
for optimum communication with an Ethernet network. Optional EnviroSense2
modules (sold separately) provide a variety of environmental monitoring
capabilities.
Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2,
SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A color touchscreen LCD lets you toggle between menus to monitor input current
level per phase, output current per load bank and per outlet with ±1% billing-
grade accuracy, environmental sensor data and network information. It also
generates a unique QR code to allow access to the switchable PDU through a
mobile device.
Features
Distributes, Monitors and Manages Network-Grade AC Power14.5kW 200-240V switched rack PDU (rPDU) with 3-phase inputRecommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network componentsIEC 309 60A Blue plug with 6-ft. (1.83 m) cord connects to compatible AC power sourceFirmware upgrades support future product enhancements 30 Switched Outlets Distribute AC Power24 C13 and 6 C19 outlets split into 3 separately breakered load banksIndividual outlets can be remotely controlled to power up, power down, reboot or lock out devicesPlug-lock insert sleeves prevent cables from becoming accidentally disconnected Color Touchscreen LCDReports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracyGenerates unique QR code for read-only access to PowerAlert® Device Manager via mobile deviceFull access available by logging into PowerAlert Device Manager via browser as user with read/write credentials
Highlights
- 14.5kW 200-240V 3-phase switched 0U PDU
- 30 individually controllable outlets—24 C13, 6 C19
- Pre-installed GbE-capable WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
- IEC 309 60A Blue PDU input with 1.8 m power cord
- Touchscreen LCD with mobile access option via QR code
Package Includes
- PDU3EVSR6G60 14.5kW 3Phase
- Switched PDU
- Built-in LX Platform interface
- Configuration cable
- (30) Plug-lock insert sleeves
- Rack-mounting hardware
- PDUMVROTATEBRKT mounting bracket accessory
- Owner’s manual
Built-In GbE-Capable LX Interface
Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager
firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and
PowerAlert Element Manager (PAEM) form a powerful tool for expanding
maintenance functions in large installations, including firmware update checks
and backup and restoration of device configurationsIPbased Auto Probe detects
lost connectivity and restores service autonomously
Broad Communications Compatibility
Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH,
FTP, DHCP and NTPSupports automatic and manual assignment of IP address
Easy 0U Installation in EIA-Standard 19 in. Racks
Mounts vertically using included toolless buttons or rack-mounting
bracketsIncluded PDUMVROTATEBRKT allows mounting with rear-facing outlets
TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule
purchases
Specifications
**OVERVIEW**
UPC Code| 037332212863
PDU Type| Switched
**INPUT
Input Phase| 3-Phase
PDU Input Voltage| 200; 208; 220; 230; 240
Recommended Electrical Service| Three-phase 60A 200-240V service
Maximum Input Amps| 35
Maximum Input Amps Details| Agency de-rated to 35A continuous
PDU Plug Type| IEC-309 60A BLUE (3P+E)
Input Cord Length (ft.)| 6
Input Cord Length (m)| 1.83
****OUTPUT
Output Capacity Details| 14.5kW (240V), 13.9kW (230V), 13.3kW (220V), 12.6kW
(208V), 12.1kW (200V) total capacity; 20A max per breakered outlet bank; 16A
max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility| 50 / 60 Hz
Output Receptacles| (24) C13; (6) C19
Output Nominal Voltage| 200-240V
Overload Protection| Three 20A circuit breakers, 1 per outlet bank
Customized Load Management Receptacles| ** Each outlet is individually
controllable via remote interface
**USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments| Reports input current per phase (L1, L2, L3), plus
output current for each output load bank (20A balanced max per banks B1-B3)
and individual output receptacle (1-30); Outlets are color-coded and labeled
for phase and load bank identification; L1-L2 feeds light-gray outlets (B1);
L2-L3 feeds black outlets (B2); L3-L1 feeds dark-gray outlets (B3)
Front Panel LCD Display| Touchscreen LCD reports NETWORK DATA (IP address,
Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT
PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage),
LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU
output in watts), OUTLET DATA (Amperage, Wattage per outlet), CONFIGURATION
DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports
data and status of E2 sensor modules; Sensor options are available for
temperature and humidity, plus input and output dry contacts), MOBILE ACCESS
(Generates a unique QR code to view reported PDU details on a mobile device)
Front Panel LEDs| One LED for each output receptacle offers power availability
information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load
bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power
OFF/breaker trip), LED OFF (Power OFF). Network Activity (Green): Flashes for
network activity. Link/Network Speed (Yellow): On steady for any speed.
Switches| LX Platform Interface: Recessed reset switch for interface reboot
and factory reset
Current Measurement Accuracy (Amps)| +/-1%
Voltage Measurement Accuracy (Volts)| +/-1%
Power Measurement Accuracy (Watts)| +/-1%
****SURGE / NOISE SUPPRESSION
Automatic Shut-Off| No
****PHYSICAL
Material of Construction| Metal
Form Factors Supported| Vertical rackmount installation supported with
included mounting brackets; supports toolless mounting in button- mount
compatible racks
PDU Form Factor| Vertical (0U)
Shipping Dimensions (hwd / in.)| 6.89 x 9.65 x 75.87
Shipping Dimensions (hwd / cm)| 17.50 x 24.51 x 192.71
Shipping Weight (lbs.)| 27.08
Shipping Weight (kg)| 12.28
Unit Dimensions (hwd / in.)| 70.000 x 2.170 x 2.860
Unit Dimensions (hwd / cm)| 177.8 x 5.5 x 7.3
Unit Weight (lbs.)| 20.01
Unit Weight (kg)| 9.08
****ENVIRONMENTAL
Operating Temperature Range| 32° to 122°F (0° to 50°C)
Storage Temperature Range| -22° to 140°F (-30° to 60°C)
Relative Humidity| 5% to 95% non-condensing
Operating Elevation| 0-10000 ft. (0-3000 m)
****COMMUNICATIONS
PowerAlert Software| LX Platform Interface: PowerAlert Device Manager
Communications Cable| USB B-to-USB A Configuration/Console Access cable
Network Monitoring Port| RJ45 Network port, RJ45 Config/Console Access port;
2x USB A ports supports a variety of Envirosense2 environmental and control
modules. See Accessories>Management Hardware section for more information
about these modules. USB B port (Configuration & Console Access)
SNMP Compatibility| SNMP V1, V2c, V3
Network Compatibility| 10 Mbps; 100 Mbps (Fast Ethernet); 1 Gbps (Gigabit)
Communications Interface| Pre-installed network card; RS-232; USB
****FEATURES & SPECIFICATIONS
High Availability PDU Features| Auto Probe Monitoring and Reboot (included);
Auto Load Shedding
****STANDARDS & COMPLIANCE
Product Certifications| CAN/CSA-C22.2 No. 60950-1 (Canada); NOM (Mexico); UL
60950-1
Product Compliance| RoHS; FCC Part 15 Class A (USA); Trade Agreements Act
(TAA)
****WARRANTY & SUPPORT
Product Warranty Period (Worldwide)| ** 2-year limited warranty