MAXIM 88841 SERENE 52 Inch 3 Blade Fan with LED Light Kit Instruction Manual

July 3, 2024
MAXIM

MAXIM 88841 SERENE 52 Inch 3 Blade Fan with LED Light Kit

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-product-
image

Specifications

  • Item/Model Number: 88841 SERENE 52 3-Blade Fan with LED Light Kit
  • Power: 27 W
  • Material: Plywood
  • Warranty: 5 Years

Product Usage Instructions

Safety Precautions
Before installation, cleaning, or servicing the fan, ensure to disconnect it from the power supply. Avoid exposing combustible materials during installation and do not install the fan on a ceiling with a combustible finish. Ensure no wood or thermal insulation is exposed to the interior of the room after installation.

Battery Installation
Use CR2032 3V batteries and install them correctly according to polarity. Do not mix old and new batteries or different types of batteries. Always securely close the battery compartment. If the compartment does not close securely, stop using the product, remove the batteries, and keep them away from children.

Fan Installation

  1. Wood Ceiling: Drill the mounting bracket into the wood ceiling with wood screws or use appropriate tools to fix it tightly. Ensure the ceiling can bear more than 60KG.
  2. Concrete Ceiling: Use an 8mm hammer drill bit to drill holes for expansion screws. Fix the bracket with the provided screws and tighten the nuts.
  3. Hanger Bracket: Install the hanger bracket to the outlet box by following the provided instructions.

FAQ

  • Q: Can I use rechargeable batteries in the product?

    • A: Non-rechargeable batteries are recommended. Do not attempt to recharge them as it may result in venting, leakage, or explosion.
  • Q: What should I do if the battery compartment does not close securely?

    • A: Stop using the product, remove the batteries, and ensure they are kept away from children. Do not continue using the product until the battery compartment securely closes.

Item/Model Num:88841
SERENE 52″ 3-Blade Fan with LED Light Kit

SAFETY PRECAUTION

  • WARNING -To make sure power is off before attempting installation.
  • WARNING -Support Directly From Building Structure. When mounted directly to the building structure, appliance installation shall not expose combustible material and do not install the appliance to a ceiling with combustible finish. The installation of the appliance cannot leave the wood of the rafters or any thermal insulation exposed to the interior of the room.
  • WARNING -To reduce the risk of fire, electric shock, or injury to persons, unplug or disconnect the appliance from the power supply before the fan installation, cleaning, or servicing.
  • WARNING -To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
  • WARNING -To Reduce The Risk Of Personal injury, Do Not Bend The Blade Brackets When installing The Brackets, Balancing The Blades, Or Cleaning The fan. Do Not Insert Foreign Objects In Between Rotating Fan Blades.
  • WARNING -Remove and immediately recycle or dispose of batteries from equipment not used for an extended period of time according to local regulations. Do NOT dispose of batteries in household trash or incinerate. Even used batteries may cause severe injury or death. Call a local poison control center for treatment information, Non-rechargeable batteries are not to be recharged. Don not force discharge, recharge, disassemble, heat above 125°C or incinerate. Doing so may result in injury due to venting, leakage or explosion resulting in chemical burns. Ensure the batteries(CR2032 3V) are installed correctly according to polarity(+ and-). Do not mix old and new batteries, different brands or types of batteries, such as alkaline, carbon-zinc,or rechargeable batteries. Always completely secure the battery compartment. lf the battery compartment does not close securely, stop using the product, remove the batteries, and keep them away from children.
  • Remove and immediately recycle or dispose of batteries from equipment not used for an extended period of time a ccording to local regulations.
  • The installation is to be in accordance with the National Electrical Code , ANSI/NFPA 70-1999 and local codes. Consult a qualified electrician if in double.
  • WARNING -To Reduce The Risk Of Electric Shock, This Fan Must Be installed With A General-Use, isolating Wall control/Switch.
  • All set screws must be checked, and re-tightened where necessary before installation.
  • After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
  • The splices after being made should be turned upward and pushed carefully up into the outlet box.
  • Conductor of a fan identified as grounded conductor to be connected to a grounded conductor of power supply, conductor of fan identified as ungrounded conductor to be connected to an ungrounded conductor of power supply, conductor of fan identified for equipment grounding to be connected to an equipment-grounding conductor.
  • CAUTION -To Reduce The Risk Of Electric Shock, Disconnect The Electrical Supply Circuit To The Fan Before Installing Light Kit.
  • WARNING -To reduce the risk of fire, electric shock, or personal injury, mount directly to a
    structural framing member of to an outlet box marked (acceptable for fan support of 15.9 kg(35lbs) or less). For outlet box mounting, use mounting screws provided with the outlet box. Must check that the outlet box is securely installed in place before

Precautions
Before using this ceiling fan, please read this manual carefully and operate strictly in accordance with the procedures.

  1. The input voltage of this product: 120V/60Hz
  2. If you have insufficient knowledge of electrical appliances, be sure to hire an experienced expert to install them.
  3. Before installing and disassembling the ceiling fan light, please turn off the power first. The installation must be installed in the order of ground wire, live wire, and neutral wire. Before disassembly, it must be disassembled in the order of neutral wire, live wire and ground wire to avoid electric shock.
  4. The ceiling fan must be installed on a solid ceiling, and the location of the ceiling fan must be able to withstand a gravity greater than 60 KG.
  5. When installing the ceiling fan, all screws must be securely locked.
  6. When the ceiling fan is rotating, no objects should touch the blades to avoid danger.
  7. The angle and elevation of the leaf frame are determined after many repeated measurements, so it cannot be changed at will. When installing the leaf frame and blades, special care should be taken not to force collisions. If the angle and elevation angle of the leaf frame are deformed that will cause the ceiling fan to shake.

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(1\)

Prepare tools before installation

Basic parameters

  1. Voltage : 120V/60Hz
  2. Power : Motor power: 27 W
  3. Speed + Color change : 6 speed +3 color temperatures
  4. Number of rotating leaves : 3 blades
  5. Fan blade material: Plywood
  6. Motor material: Pure copper wire winding and high-quality silicon steel stator, high efficiency, super quiet, energy saving.
  7. Control method : Remote control
  8. Reversible : YES
  9. Warranty : 5 Years

Installation steps and instructions

1 Ceiling Fan Kit Before the ceiling fan is installed, there are the following accessories in the carton please check them one by one, if there is no shortage, you can install it.

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(2\)

Mounting Bracket Fasten Method

  1. Wood ceiling: Drill the mounting bracket directly into the wood ceiling with wood screws (4 pieces) or Use tools to fix the mounting bracket tightly. (The ceilina must bear more than 60KG)MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image \(3\)
  2. Concrete ceiling: First use an 48mm hammer drill bit to drill the hole according to the length of the expansion screw, then use the equipped expansion screws(2 Pieces) to fix the bracket on the ceiling, and then Please use 8mm drill hole before installing with M6 expansion screws
  3. Install the hanger bracket to the outlet box
    • Take off the screws on the outlet box.
    • Install the hanger bracket to the outlet box by screws

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(5\)

Note

  1. According to the ceiling of different materials, use different screws to fix the mounting bracket (as shown above).
  2. After the bracket is fixed, it must be determined to be able to bear the weight of more than 60 kg(test pull by hand) for safety.
  3. Ceiling fans cannot be installed on gypsum ceilings.
  4. To reduce the risk of fire, electric shock, or personal injury mount to an outlet box marked “Acceptable for Fan Support”.Use the mounting screws provided with the outlet box. Most outlet boxes commonly used for supporting lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

Suspension Installation

  1. Select the downrod

    • There are two downrod of 4 inch and 6 inch in the package, customers can choose according to the height of the house.

    • The normal default is to install the 4 inch downrod

    • How to replace the 6 inch downrod
      Notice: Make sure the fan blades at least 7 feet above the floorMAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(6\)

    • Loosen the two fixing screws (as shown in Figure 2).

    • Push the downrod upwards (as shown in Figure 3) out of the horizontal tip (as shown in Figure 4).

    • Then pull out the 4.5 inch downrod to replace another 12 inch downrod (as shown in Figure 5).

    • After replacement, follow the above installation steps 4-3-2 to install until it is restored to the state shown in Figure 1.

    • Finally, you must pay attention that the two fixing screws must be firmly locked.

  2. How to install Suspension Installation

  3. Remove the positioning screws from the fan body as follows and place them side by side to proceed to the next step (Figure 6)

  4. Get off the pin off the downrod by remove the R clip, and get the lead wire through the downrod and canopy, then seat the downrod into the fan body & rotate the downrod until the holes on the downrod will match with the holes on the fan body, finally, you should get the pin through the holes and fix the pin by the R clip in another side (Figure 7)

  5. Tighten the two set screws removed previously.MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image \(7\)

  6. Hang the fan on the hanger, and then slowly rotate the fan downrod to make the lugs on the hanger fit with the groove of the hanging ball on the downrod. (Figure 9)

The groove on the – downrod ball must be exactly the same as the lug on the hanger.

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(8\)

Attaching Fan Blades

  1. Take off the screws on the blade arms, and save them for next step. (Figure 10)
  2. Tighten the fan blades into the blade arms. Make sure all screws are fixed tightly for safety. (Figure 11)

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(9\)

Note: The solid wood fan blades have a certain squeezing space. The blades must be installed with washers, and pay attention to locking with conventional force. Do not continue to apply force after the blades are locked to continue screwing in the screws, otherwise It will cause irreversible failures to the motor coil

Install lamp

  1. Remove the three fixing screws from the lamp holder. (Figure 12)
  2. Please plug the 2 light wires to the LED board properly, and check whether the driver output wires and the LED source board are tightly inserted, lock the lamp plate to the lamp holder with screws. (Figure 13-14)
  3. Install the lamp shade in place and rotate the lamp shade clockwise.(Figure 15)

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(10\)

Wiring
The all-pole disconnect circle breaker with a contact distance of 3mm must be connected to the fixed wiring.

Controller wiring Diagram

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(11\)

Wiring Method: One Live One Neutral Use Effect

  1. If a regular single pole switch is connected, it can only control to turn on or off the light, but not control the fan. The fan must be turn on/off and adjust by remote control.
  2. If the regular single pole switch is not connected, the remote control can directly control the lights and fans separately

Note: This Ceiling fan built in light status memory function. When the power is turned off and turned on again, the light will back to the last status. If the light is turn off by remote control, the light will keep the turn off mode. Need use remote control to turn on the light after the power switch on. If the light is turn on before the power switch off, the light will remember the turn on status, the light will keep turn on once switch on.

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(12\)

  1. Connect the ground wire from ceiling to three green/yellow wires from the mounting bracket, the hanger ball on the downrod, and the receiver (AC IN E).
  2. Connect the neutral wire from ceiling to receiver white wire (AC IN N).
  3. Connect the live wire from ceiling to receiver black wire (AC IN L).
  4. Plug in the light wires and motor wires in the correct way as indicated in the diagram.

Note: The slotted side of the plug face the slotted side of the socket.

Canopy Installation
Fix the canopy with fixing screws and ensure that the screws are tightened. (Figure 16)

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(13\)

Balance adjustment method of ceiling fan.
If there is any wobble after ceiling fan installation, please confirm whether the screws that fix the hanger ball, mounting bracket, hanger, blade holder, and blade are locked. If one of the above parts is not locked, please re-lock it. If it is locked, please adjust it as follows.

  1. Change the position of the fan blades:
    • There is no improvement after the swap blades position. Please remove the fan blades 2 and 3 and re-lock each other to observe the effect.MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image \(14\)
  2. Adjust with balance kit.
    • Take out the balance bag from the package box, use a balance clamp to select one of the fan blades and clamp the balance clamp on the edge of the tail end of the fan blade (Figure 18)
    • Turn on the fan switch to see whether the wobble of the ceiling fan has been reduced. If it does not improve, try another fan blade. Experiment with all the fan blades in turn to find the blade with the weakest clamping balance.
    • Clamp the balance clamp on the fan blade with the weakest wobble, move it in or out on the edge of the fan blade, turn on the ceiling fan to find the best position of the balance clamp to control the wobble balance (Figure 18)
    • Take the balance sticker, tear off the double-sided tape of the balance sticker, and stick the balance sticker on the center of the blade at the position of the balance clip (Figure 18)

Precautions

Warning
In order to prevent fire and electric shock, it is forbidden to install and use the electric switch which is not equipped with this ceiling fan.

Maintenance and repair of ceiling fans

  1. It is recommended to check the connecting parts of the fan ar least once a year, such as the hanger, the hanging pipe fastening screw and the fan blade, to ensure that their connection is still safe and reliable.
  2. Clean the ceiling fan regularly to keep the surface clean and clean. When removing surface dust, please use a soft brush or cloth. When removing oil or laminate, wipe it off with a slightly wet cloth. Do not rinse with water directly.
  3. Motor bearing is already provided with grease, do not add lubricating oil to the motor of ceiling fan. To avoid scratching the surface.

Ceiling Fan Troubleshooting Solutions & Common Problems

MAXIM-88841-SERENE-52-Inch-3-Blade-Fan-with-LED-Light-Kit-image
\(16\)

WARNING / AVERTISSEMENT

  • INGESTION HAZARD: This product contains a button cell or coin battery.
  • DEATH or serious injury can occur if ingested.
  • KEEP new and used batteries OUT OF REACH OF CHILDREN

Read User Manual Online (PDF format)