QOCA thermo02C Wearable BLE Thermometer User Manual
- June 29, 2024
- QOCA
Table of Contents
thermo02C Wearable BLE Thermometer
“`html
Product Information
Specifications:
- Product Name: QOCA Wearable BLE Thermometer
- Model: thermo02C
- Version: 3A Quanta
Product Usage Instructions
Safety Notes:
-
Read the user guide carefully before using the QOCA Wearable
BLE Thermometer. -
Use the thermometer for clinical assessment and personal
reference only. -
Maintenance should be done by professional technicians
only. -
Use specified accessories to avoid damage or inaccurate
readings. -
Avoid contact with power sources and damaged accessories.
-
Replace low battery accessories promptly to prevent
malfunction. -
Avoid interference from other electronic devices during
measurements. -
Avoid extreme temperatures and keep away from pets or
children.
Getting Started:
-
Charging the QOCA Wearable BLE Thermometer:
-
Connect the charger (Model: CR1) to the thermometer.
-
Ensure a full charge before initial use.
-
Bluetooth Pairing:
-
Turn on Bluetooth on your smartphone or device.
-
Follow the pairing instructions on the QOCA vital+ APP (Model:
thermo02C). -
Wearing the Thermometer:
-
Apply the QOCA Wearable BLE Thermometer on the body as
instructed. -
Ensure a snug fit for accurate readings.
FAQ
Q: Can I use the QOCA Wearable BLE Thermometer for medical
diagnosis?
A: The thermometer is for clinical assessment and personal
reference only. Consult a healthcare professional for medical
diagnosis.
Q: What should I do if the thermometer stops working?
A: Contact customer support for assistance or consult a
professional technician for maintenance.
“`
QOCA Wearable BLE Thermometer
Model thermo02C
Version: 3A Quanta
Table of Contents
Safety Notes ……………………………………………………………… 4
Product Overview……………………………………………………15 Introduction ………………………………………… 15
Product Contents…………………………………. 16 QOCA Wearable BLE Thermometer (Model:
thermo02C) ……………………….17 Holder Patch (Model: thermo02C-P1) 19 Charger (Model:
CR1)……………………..20
Getting Start …………………………………………………………….21 Charging QOCA Wearable BLE
Thermometer ………………………………………. 21
2
Bluetooth Pairing …………………………………. 22 Wearing QOCA Wearable BLE Thermometer
(thermo02C)………………………………………… 23
QOCA vital+ APP……………………………………………………27 Main Screen ………………………………………… 28
History………………………………………………… 29 Detail Information………………………………… 30
Other Information…………………………………………………..31 The LED Indication ……………………………….. 31
Maintenance ……………………………………….. 33 Product Specification……………………………. 33
Bluetooth Specification ………………………… 36 Customer Support ……………………………….. 37
3
SAFETY NOTES
Please read through this user guide carefully before using QOCA WEARABLE BLE
THERMOMETER.
The QOCA WEARABLE BLE THERMOMETER is to be used for clinical assessment and
personal reference only.
The QOCA WEARABLE BLE THERMOMETER consists entirely of sophisticated medical
electrical parts. Maintenance can only be carried out by professional
technicians. Unauthorized disassembly of the device by the user is not
allowed. It may cause malfunction if unauthorized disassembly of the device.
The QOCA WEARABLE BLE THERMOMETER must be used with its specified accessories.
The use of accessories from other brands can damage the device or cause
inaccurate readings.
4
Do not allow the connectors or contacts on the devices to come into contact
with any kind of power source during use.
Damaged or faulty accessories should not be used.
When the QOCA WEARABLE BLE THERMOMETER is low on battery power, it will
automatically stop taking measurements and the corresponding indicator lights
will be blink.
Avoid using devices that can affect the accuracy of the readings when the QOCA
WEARABLE BLE THERMOMETER is taking measurements.
Avoid using other electronic devices when the QOCA WEARABLE BLE THERMOMETER is
taking measurements. If using another other electronic device is necessary,
please check to ensure the thermometer is continuing to take measurements
normally.
5
Do not use the QOCA WEARABLE BLE THERMOMETER near open flames or in excessive
heat. The changing environmental conditions may influence the body temperature
measurement.
Pay attention to ensure that the QOCA WEARABLE BLE THERMOMETER is not
swallowed by pets or children.
If QOCA WEARABLE BLE THERMOMETER must be used to take measurements over an
extended period of time, please inspect the contact point of the thermometer
at least once every 24 hours to make sure that the thermometer is in the right
position and that there is no allergic reaction on the user’s skin.
Do not use high-frequency instruments or electrical medical equipment when
using the QOCA WEARABLE BLE THERMOMETER.
The QOCA WEARABLE BLE THERMOMETER can only take measurements while the subject
6
is at rest (e.g., while sitting or lying down) or engaging in ordinary
activity. Any activities not permitted by the attending physician may affect
the accuracy of the measurements. Do not expose QOCA WEARABLE BLE THERMOMETER
to extreme temperatures, extremely moist environments, dust, or direct
sunlight. Do not clean the QOCA WEARABLE BLE THERMOMETER with corrosive or
abrasive cleaning agents. The QOCA WEARABLE BLE THERMOMETER and its
accessories should be disposed of properly. Disposal of the device and its
accessories should comply with the relevant local regulations. The QOCA
WEARABLE BLE THERMOMETER has been tested and certified to international
electro-magnetic compatibility (EMC) standards for medical equipment (EN
60601-1
7
and EN 60601-1-2). If abnormal behavior is observed due to EMC disturbances,
please relocate the device accordingly. The expected service life of the QOCA
WEARABLE BLE THERMOMETER is 1 years. People with sensitive skin or with known
skin conditions should use the QOCA WEARABLE BLE THERMOMETER with caution. If
irritation such as redness, severe itching or allergic symptoms (i.e. hives)
develop, instruct patients to remove the QOCA WEARABLE BLE THERMOMETER
immediately and have them contact their physician. Do not use QOCA WEARABLE
BLE THERMOMETER on patients with known skin allergies or family history of
skin allergies. Do not use QOCA WEARABLE BLE THERMOMETER in MRI or X-ray room.
This device should not be used adjacent to or stacked with other equipment.
8
Due to electrostatic discharge (ESD) sparks may cause sparks. QOCA WEARABLE
BLE THERMOMETER is not suitable for use in an explosive environment.
Avoid using heavy electronic equipment or other sources of electromagnetic
interference (such as electric blankets) when using the QOCA WEARABLE BLE
THERMOMETER.
The device is intended for use by the person who are educated eight-grade or
above.
If re-use QOCA WEARABLE BLE THERMOMETER or its component, it may cause no
stickiness or have inaccurate readings.
To avoid low-temperature burn, please remove QOCA WEARABLE BLE THERMOMETER
immediately when your temperature is over 41°C.
If you change the setting value of the alert temperature, it will affect the
time point of
9
QOCA vital+ APP notification, please confirm it before changing it. If using
several QOCA WEARABLE BLE Thermometer in the same space, please unify the
setting values of alert temperature to avoid information confusion. Whether it
is restarting QOCA vital+ APP, restarting the smart phone, or even a sudden
power failure of smart phone, the setting value of alert temperature remains
the value set last time. When wearing QOCA WEARABLE BLE Thermometer, maintain
a distance of at least 6 inches from the pacemaker. Do not use accessories
which are not supplied or recommended by the manufacturer. Other accessories
may negatively affect EMC performance. Household electronic devices such as
humidifiers, heaters or microwaves, and so on
10
may be susceptible to cause interference with the device. Do not expose the
device to strong electrostatic fields or strong magnetic fields to avoid
inaccurate results. If abnormal behavior is observed due to EM disturbances,
please relocate the device accordingly. Use of this device adjacent to or
stacked with other devices should be avoided as it could result in improper
operation. Any part of the monitor should be used no closer than 30 cm (12
inches) to wireless communication devices, such as networking devices, mobile
phones, and walkie-talkies, or it can result in error display or inaccurate
results.
11
Precaution:
Before using this product, please read the instructions carefully.
When using this product, the user should try to remain in a resting state to
obtain accurate body temperature information for reference by medical
personnel.
When it is necessary to use this product for an extended period, observe the
adhesive area at the back of the patch at least every 24 hours to ensure the
position of the adhesive and check for any signs of skin allergies in the
person being measured.
Do not use “shockers” or other related medical electronic devices while using
this product.
If stable measurement values cannot be obtained when using this product for
measurement, stop the measurement immediately.
12
After placing this product under the armpit with hands down for 5 minutes, a
stable armpit body temperature can be measured.
This product can only be used for measurement when the person being measured
is at rest (sitting or lying down) or engaged in normal activities. Any
activity not permitted by a treating physician may affect measurement
accuracy.
Do not use this product in high humidity environments. It can be used during
showers, but do not immerse it directly in water.
Do not clean or wipe this product with corrosive or abrasive cleansers.
Dispose of this product in accordance with local regulations.
Using this product near high-frequency communication devices may affect the
accuracy of medical electronic equipment.
13
If you experience itching or swelling when using this product, remove it
immediately and stop the measurement.
14
PRODUCT OVERVIEW
Introduction
QOCA WEARABLE BLE THERMOMETER measures body temperature continuously.
Installed the sensor to a dedicated holder patch and place it under the
armpit, user can easily monitor their body temperature at home or at hospital.
The measured body temperature can be transferred via BLE up to 14 days with
embedded rechargeable Li-battery technology.
The device is operated by the person who are educated eight-grade or above.
15
Product Contents
After purchasing QOCA WEARABLE BLE THERMOMETER, Please check the product package to ensure that the following items are included:
Items
Model Number
Quantity
Sensor
thermo02C
1
Charger
CR1
1
Holder Patch
thermo02C-P1
1
Quick Guide
NA
1
- For purchasing holder patch, please contact
manufacturer. (10 pcs/box) 16
QOCA Wearable BLE Thermometer
(Model: thermo02C)
Front View:
1
2 2
1
Power Key
2
LED Indicator
17
Back View:
1 2
1
Spring (contact to
holder patch)
2
Charging contact point
18
Holder Patch (Model: thermo02C-P1)
1
1
stainless steel contact point
19
Charger (Model: CR1)
Charging point
USB hole
20
GETTING START
Charging QOCA Wearable BLE Thermometer
Please follow the charging steps to use QOCA Wearable BLE Thermometer
1. Connect the charger with USB cable to an adaptor, which complied to IEC
60601-1 and IEC 62368-1 class standards.
2. Place the thermometer on charger. 3. It is fully charged while the battery
LED indicator in
solid green.
21
Charger
Thermometer
USB cable
Bluetooth Pairing
Adaptor
Please follow the steps to pairing the thermometer.
1. Power on the QOCA wearable BLE thermometer 2. Launch QOCA vital+ APP and
then enter to the
pairing page of QOCA vital+ APP. Please select the device name follows the
format “MHFXXXXXX”. 3. Wear the QOCA wearable BLE thermometer
22
Wearing QOCA Wearable BLE Thermometer (thermo02C)
Wearing this product require to attach the dedicated holder patch
(thermo02C-P1) on the armpit.
IMPORTANTPlease clean and keep your armpit dry before attach QOCA Wearable BLE
Thermometer. We recommend that hair removal and skin exfoliation will help the
contact of holder patch. And avoiding any activities that cause sweating
during this period.
IMPORTANTIf the skin at the contact point develops a rash, blisters,
reddening, or other irritation, please contact a medical professional or
physician.
IMPORTANTAble to engage in daily activities, DO NOT do strenuous exercise,
bathing or swimming.
23
A. Install QOCA Wearable BLE thermometer Step 1: First, install QOCA Wearable
BLE Thermometer on the dedicated holder patch. DO NOT power on QOCA
Wearable BLE Thermometer
before install on the holder patch.
24
Step 2: Press the power button till QOCA Wearable BLE Thermometer flash green
light. After power on, the status indicator ” ” will keep flashing orange
light. The orange light will turn off once it attach on armpit. DO NOT
touch the stainless steel contact point in front of the holder patch while
QOCA Wearable BLE Thermometer is in power on process.
B. Clean the skin
Step 3: If there has hair under the armpit, please remove it before attach the
deice. If no, please skip this step. Step 4: Use alcohol pad to clean the skin
and wait around 1 minute for drying.
25
C. Attach the dedicated holder patch Step 5: Remove the release paper of
holder patch (thermo02C-P1). Step 6: Place the temperature measuring point
under the armpit. And press the temperature measuring point at least 10
seconds till it’s fully attached on armpit. Step 7:The wearing of QOCA
wearable BLE thermometer
26
QOCA VITAL+ APP
Launch the QOCA vital+ APP for connecting to QOCA Wearable BLE thermometer as
below figures
27
Main Screen
The main page shows current measured temperature value:
Body temperature
Function bar 28
History
In history page, you can check the measured data.
29
Detail Information
User can check the following information: APP version, Firmware version, and
device serial number. The measuring period, alter temperature value, and the
temperature display unit also can be set in this page.
30
OTHER INFORMATION
The LED Indication
Event Power on
Power off
Device does not place on holder patch
Operation Press power button for 1 second and then release the button Press
power button for 5 seconds
NA
LED Indication Both the status LED and battery LED flash green light. And after power on, the status LED will keep flash orange. Both the status LED and battery LED in solid blue light till pressing button for 5 seconds to compete power off process The status LED flash orange light (fast)
31
Patch off
NA
Low Battery
NA
Bluetooth connected successfully
Bluetooth disconnected Charging
Fully Charging
Launch QOCA vital+ APP and connect to device NA
Place on charger Place on charger
The status LED flash orange light (fast) The battery LED flash orange light
The status LED flash blue light several times
The status LED flash orange light every 10 seconds The battery LED flash
orange light The battery LED flash orange light
32
Maintenance
The QOCA Wearable BLE thermometer and charger are reusable components and
should be cleaned by following the instructions. To clean the thermometer and
the charger, wipe the device with a dry cloth or alcohol pad. And the holder
patch is one-time use. DO NOT reuse it.
Product Specification
Measuring Range
25 ~ 42 (77 ~ 107.6 )
Resolution
0.1 (0.1)
Accuracy
±0.1 (±0.18), for body temperature range: 35.5 ~ 42
33
Location Connectivity
Measured Frequency
Battery IP Button Indication Weight
±0.2 (±0.36), for body temperature range: 25 ~ 35.5
Armpit
BLE 5.0 (Connection Distance: 10m at open space)
Default measuring period: every 60 seconds. (Note: Place it under the armpit
at least 5 minutes to get a stable temperature value)
Lithium polymer, 350 mAh
IP34
1 button
Two LEDs 12.7 ±0.5g
34
Size (mm) L x W x H
Altitude
Working Condition
Storage Condition
Thermometer30.7 x 30.7 x 9.4 ±0.5 Charger41.1 x 41.1 x 13.45 ±0.5
2000m 5 ~ 42°C, 10% ~ 95%, noncondensing -20 ~ 60°C, 10% ~ 95%, noncondensing
35
Bluetooth Specification
Items Operating Frequencies
Parameter 2402~2480MHz
Channel Spacing
2MHz
Channel number
40
Modulation
GFSK
Antenna Gain
FPC Antenna, Peak Gain: -2.46 dBi
36
Customer Support
For additional technical information, contact Quanta Customer Support
Department
Quanta Computer Inc.(QCI) Address: No. 188, Wenhua 2nd Rd., Guishan Dist.,
Taoyuan City 333, Taiwan TEL: +886-3-327-2345 FAX: +886-3-318-4207 Email:
QOCA@quantatw.com
37
Federal Communications Commission (FCC) Statement
15.105(b)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is
38
no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.”
39
“15.21
You are cautioned that changes or modifications not expressly approved by the
part responsible for compliance could void the user’s authority to operate the
equipment.”
FCC RF Radiation Exposure Statement:
1. This Transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
2. For portable operation, this device has been tested and meets FCC RF
exposure guidelines. When used with an accessory that contains metal may not
ensure compliance with FCC RF exposure guidelines.
40
15.19 This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: 1) this device may not cause harmful
interference and 2) this device must accept any interference received,
including interference that may cause undesired.
41
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>