KaWe MedCharge 4000 Charging Station User Manual

June 3, 2024
KaWe

KaWe MedCharge 4000 Charging Station

Dear buyer! Thank you for choosing a KaWe product. Our products are known for high quality and durability. This KaWe device (classified as a medical device) complies with the provisions of Directive EU 2017/745 (European Directive on Medical Devices), whereby it is classified as a medical product of class 1.

  • Please carefully consider this user’s manual and read all the provisions prior to use. Follow the warnings and safety instructions.
  • Prior to use, please carefully consider the maintenance procedure.
  • Application: KaWe MedCharge 4000 may only be used by authorized or instructed personnel.
  • Intended use: Charging station for charging KaWe charging handles of type „2.5 V“ and „3.5 V“ with NiMH or Li-Ion charging battery.
  • The battery type is recognized automatically, i.e. NiMH or lithium-ion, as well as the correspon-ding management of the charging characteristics.
  • Chargeable elements:
    • Type „C Li-Ion 3.5 V with 2250 mAh“
    • Type „AA NiMH 2.5 V with 1700 mAh“
    • Type „AA NiMH 3.5 V with 750 mAh“
    • Type „AA NiMH 2.5 V with 3050 mAh“

Improper use of the device/contraindications for use: Any other method of use or use for purposes other than intended is considered improper. The manufacturer is not responsible for damage resulting from such use. In this case, only the operator assumes all risks.
Additional information, maintenance and storage : No maintenance is required.

Warnings

  • Follow additional requirements specified in user’s manuals for rechargeable batteries for the charging time.
  • Caution! Do not use dry batteries – risk of explosion!
  •  Before installation, check that the mains voltage used is within the permissible range (see technical data).
  • After charging has been completed, remove the battery handles from the device and disconnect the power cable of the charger from the mains.
  • The device may only be used in closed, dry rooms.
  • Do not use the charger in areas subject to strong magnetic fields (MRI systems).
  • Do not clean the inside of the charger as this could cause a short circuit.

Maintenance

After the power supply plug has been plugged into the outlet, the charger is ready for use (the green LED will read: „Standby“). After the battery handle have been inserted, the LED of the corresponding charging socket signals the charging status (red = charging, green = fully charged, blinking red = error). After the charging voltage has been reached, the LED switches from red to green, i.e. the battery handle is fully charged. When the handle is inserted into the socket, the charging process starts automatically. If necessary, a take-up sleeve is used as an adapter for the various handles. After unscrewing the cover, the battery can be removed or replaced.

Technical data

  • Input voltage………………………………..100 V–240 V +/- 10%, 50–60 Hz
  • Power factor…………………………………>0.99
  • Chargeable elements…………………….NiMH and Li-Ion
  • Number of elements……………………..NiMH 2–3 elements, Li-Ion 1 element
  • Chargeable capacity………………………min. 250 mAh, max. 4500 mAh
  • Charger input voltage……………………8.55–9.45 VDC
  • No-load power consumption…………< 0.5 W
  • Rated power consumption…………….about 4.5 W
  • No-load output voltage…………………< 9 VDC
  • Rated output voltage…………………….2 x 3.6 VDC
  • Rated charging current………………….2 x 250 mA +/-10%
  • Charge end voltage……………………….6 VDC +/-1%
  • Charge end current………………………..10–30 mA for Li-Ion
  • Reverse current without power………< 0.1 mA at 4.2 V
  • Recharging current………………………..NiMH 3–8 mA, Li-Ion — no recharging current
  • Electrical breakdown strength………..4 kV
  • Protection rating…………………………..II

Standards: IEC 60601-1 & IEC 60601-1-2

Safety functions

  1. Electronic protection against short circuit, mechanic protection against reverse polarity.
  2. Overheating protection (linear derating).
  3. Built-in reverse polarity protection (safety).
  4. Overvoltage shutdown.
  5. Battery temperature control.

Safety instructions

  1. Use only accessories recommended by KaWe. Any other use may cause fire, electric shock or injury.
  2. The supplied mains power supply produces 9 VDC and 1200 mA direct current. Do not use mains units with specifications other than above-mentioned, as this may damage the charger or the power unit with the plug.
  3. Do not alter the supplied plug. If the plug is not compatible with the existing outlet, it must be replaced by a qualified technician. Improper connections can cause electric shock.
  4. Do not use a damaged charger. Have it repaired by a specialist.
  5. Do not disassemble the charger. Improper installation of the charger may cause fire or electric shock.
  6. While charging, the battery and charger may become warm.
  7. Do not use the charger as a power source for electrical appliances.
  8. Keep the charger and power supply unit with a plug dry.

Cleaning

Clean the charger external surface with a damp, soft and lent-free cloth. A napkin moistened with alcohol can be used to disinfect the device. Do not immerse the device in so-lutions or cleaning agents!

At 30 %–75% relative humidity

  • Storage +5 °C to +45 °C

  • Transportation -20 °C to +50 °C

  • Operation +10 °C to +40 °C

  • Disposal:
    Dispose of decommissioned electrical devices in an environmentally friend-ly manner. It is forbidden to dispose of these devices together with household waste. Hand them over to collection points for electrical and electronic waste for subsequent recycling.

  • General accessories:
    To find out more about these products, visit our homepage: www.kawemed.com

  • Options:
    Wall mount bracket.

  • Manufacturer: KaWe

  • Manufacturer’s contact details:
    Dealer’s address or phone number: +49-7141-68188-0

  • Warranty:
    The warranty for the device totals two years from the date of purchase with proper handling and following the operation manual. If any issues arise or repair is necessary, please contact your dealer.
    Basic UDI-DI: 4030155KaWe1204ZB

Symbol key

  • Manufacturer
  • Date of manufacture
  • Serial number
  • Article number
  • Protection rating II
  • Please follow the User’s Manual
  • Medical device
  • Caution
  • CE conformity mark
  • GOST-R certifi cation of export goods imported into Russia
  • Temperature range
  • Separate disposal of electric and electronic devices
  • Use the device only in dry rooms

Information for users and patients
All serious incidents involving this device must be immediately reported to the manufacturer and the competent authorities of the respective Member State in which the user and/or patient is located.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals