Wizard and Pendant Operation
The following is a guide to the operation of the PD92201 remote pendant.
Please verify the battery type selected for the proper button and LED
operation. The colour of the Battery Type LED on the the converter indicates
the setting.
FLA – Flooded Lead Acid (GREEN LED battery indicator)
Action| Automatic & Manual operation are the
same| Mode| Converter Output Voltage
Press the button once. Or hold for 0 -3 seconds.| The light will go solid|
Boost (Bulk)| 14.4VDC
Press and hold the button untill it blinks then let go .Or hold for 3-6
seconds.| Will flash on and offat a 1 cycle per second rate.| Normal mode
(Absorption)| 13.6 VDC.
Press and hold the button again untill it stops flashing. (light will be
out)Or hold for 6-9 seconds.| The light will flash briefly once every6
seconds| Storage mode (Float)| 13.2VDC.
Holding the button for longer than 9 seconds will return the Wizard to
“Normal” mode. Once the button is released, automatic operation willresume.|
Will flash on and offat a 1 cycle per second rate.| Normal mode (Absorption)|
13.6 VDC.
AGM – Absorbed Glass Material (WHITE LED
battery indicator)
Action| Automatic & Manual operation are the
same| Mode| __Converter Output Voltage
Press the button once. Or hold for 0 -3 seconds.| The light will go solid|
Bulk| 14.0VDC
Press and hold the button untill it blinks then let go .Or hold for 3-6
seconds.| Will flash on and offat a 1 cycle per second rate.| Absorption| 14.7
VDC.
Press and hold the button again untill it stops flashing. (light will be
out)Or hold for 6-9 seconds.| The light will flash briefly once every6
seconds| Float| 13.6VDC.
Holding the button for longer than 9 seconds will return the Wizard to Regular
mode. Once the button is released, automatic operation will resume.| Will
flash on and offat a 1 cycle per second rate.| Absorption| 14.7VDC
Lithium – LiFePO4 (BLUE LED battery indicator)
Action| Automatic & Manual operation are the
same| Mode| Converter Output Voltage
Press the button once.Or 0 -3 seconds| Long flash followed by ashort wink.|
Charge mode| 14.4VDC
Press and hold the button untill the flashpattern changes.| Long off followed
by a short flash.| Idle mode| 13.6 VDC.
Holding the button for longer than 3 seconds will put the Wizard in Idle mode.
Once the button is released, automatic operation will resume.| Long off
followed by a short flash.| Idle mode| 13.6 VDC.
Constant Voltage – Single-stage (Magenta LED
battery indicator)|
---|---
Action| Automatic & Manual operation are the
same| Mode| Converter Output Voltage
No action| Will flash on and offat a 1 cycle per second rate.| Single-stage|
13.6 VDC.
**Notes ***
The PD92201 Charge Wizard remote pendant and the Battery Type indicator LED on
the PD9300 will illuminate if the AC Power is applied to the
converter/charger.
The Battery Type indicator will extinguish 30 seconds after the last button press.
The remote pendant will always indicate the Charge Wizard mode whenever AC Power is applied.
When AC Power is removed, the pendant will not illuminate.