Product Specifications
- Model : R96MSN
- Heating Input (BTUH):
- R96MSN0401410A: 40,000
- R96MSN0401712A: 40,000
- R96MSN0601716A : 60,000
- R96MSN0801716A: 80,000
- R96MSN0802120A: 80,000
- R96MSN1002120A: 100,000
- R96MSN1202422A: 120,000
- AFUE (up to):
- Upflow: 97.0%
- Downflow: 95.0%
- Cooling Capacity CFM range @ 0.5 in. W.C.: 155-1000 to 290-2240
- Operating Dimensions: 35 x 14-3/16 x 29-1/2 to 35 x 24-1/2 x 29-1/2 inches (millimeters)
- Shipping Weight: 123 lbs (56 kg) to 181 lbs (82 kg)
Product Usage Instructions
- Efficiency/Performance: The R96MSN gas furnace boasts up to 97% AFUE, ensuring efficient heating performance. The single-stage operation with a multi-speed ECM blower motor enhances reliability and performance.
- Reliability/Durability: This furnace is designed for reliability and durability with features like a heat exchanger to prevent overheating and a nitride ignitor for efficient ignition. The one-piece steel cabinet ensures sturdiness and longevity.
- Easy-to-Install and Service: The unit is designed for easy installation and service, making maintenance hassle-free. It comes with an OFF delay feature for added convenience.
Efficiency/Performance
- Up to 97% AFUE in upflow/horizontal, up to 95% AFUE in downflow
- Multi 18-speed, constant torque (MCT) ECM blower motor
- Enhanced diagnostics with easy to read 3 digit display for faults and status
- Supports single-stage cooling units
- Insulated heat exchanger compartment
- All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirement
- Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w. c. when tested in accordance with ASHRAE standard 193
- Approved for twinning applications (0601716, 0801716, 0802120, 1002120, 1202422) with accessory (order separately)
- Approved for manufactured housing/mobile home applications (0401410 through 1202422) with accessory (order separately)
Reliability/Durability
- Flame roll−out sensors standard
- Adjustable heating blower OFF delay
- Factory set blower ON delay
- RPJ® primary heat exchanger
- Stainless steel secondary heat exchanger
- High temperature limit control designed to prevent overheating
- Direct ignition with Silicon Nitride ignitor
- High-quality, corrosion-resistant, one-piece steel cabinet
Easy-to-Install and Service
- On-board NFC antenna makes setup a tap away when using the service technician app
- Direct vent (2-pipe), single-pipe venting, or ventilated combustion air
- 24 VAC humidifier terminal, electronic air cleaner terminal
- 35” (889mm) high, for ease of installation
- Quarter turn knobs for easy door removal and secure attachment
- Convertible to propane with gas conversion accessory kit
- Four position − upflow/downflow/horizontal (left/right) installation
- Twelve different venting configurations
- Through the casing flue pipe for counterflow or horizontal applications with accessory (order separately)
- Concentric vent available
- Self diagnostics with super bright LED
- Slide out heat exchanger and blower assembly
Limited Warranty
- 20-year heat exchanger limited warranty
- Five-year parts limited warranty
- With timely registration, an additional five-year parts limited warranty
For residential applications only. See warranty certificate for complete details and restrictions, including warranty coverage for other applications.
For California Residents: If installed with a manufactured (mobile) home conversion kit in SCAQMD: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com
Illustrations and photographs are only representative. Some Product models may vary.
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
WARNING
CARBON MONOXIDE POISONING AND FIRE HAZARD
Failure to follow this warning could result in personal injury, death, and/or
property damage. This furnace is not designed for use in recreation vehicles
outdoors Failure to follow this warning could result in personal injury,
death, and/or property damage.
Unit Performance Data
FAQ
Q: What is the warranty coverage for the R96MSN gas furnace?
A: The limited warranty covers residential applications only. For complete
details and restrictions, refer to the warranty certificate included with the
product.
Q: Can this furnace be used in mobile homes?
A: Yes, the R96MSN gas furnace can be used in mobile home applications with
the appropriate accessory ordered separately.
Q: How can I check for faults and status on the furnace?
A: You can read the 3-digit display on the furnace to monitor faults and the
status of the unit.