ZEBRA 4Sight XV6 Fanless Industrial Imaging Computer User Guide

June 21, 2024
ZEBRA

ZEBRA 4Sight XV6 Fanless Industrial Imaging Computer

Specifications

  • Product: Zebra 4Sight XV6
  • Class: A
  • Intended Use: Not for residential environments
  • Regulatory Compliance: FCC Part 15, Directives 2014/30/EU, 2014/35/EU, 2011/65/EU
  • Manufacturer: Zebra Technologies B.V
  • Website: zebra.com

Regulatory Information

This device is approved under Zebra Technologies Corporation.
This guide applies to the following model number: XV6
All Zebra devices are designed to be compliant with the rules and regulations in the locations they are sold and will be labeled as required.

Local language translation
Any changes or modifications to Zebra equipment not expressly approved by Zebra could void the user’s authority to operate the equipment.
Declared maximum operating temperature: 45°C

WARNING : This is a Class A product. This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.

Regulatory Markings
Regulatory markings subject to certification are applied to the device. Refer to the Declaration of Conformity (DoC) for details of other country markings. The DOC is available at: zebra.com/doc.

Safety Precautions

Zebra 4Sight XV6 safety precautions and key to symbols
Before installing, connecting to, and using Zebra 4Sight XV6, you shall be aware of the meaning of the symbols on the unit and important safety precautions. The following is a list of precautionary symbols on the unit and their meaning:

Symbola Description
The case of your Zebra 4Sight XV6 can become quite hot and should not be

touched while operating.

Always allow hot surfaces to cool down before touching your Zebra 4Sight XV6.

| • Caution: Consult this product’s installation and hardware reference manual before installing, connecting to, and using Zebra 4Sight XV6. For hardware installation instructions, refer to Chapter 2: Getting Started with your Zebra 4Sight XV6 Unit and Chapter 3: Cleaning the air filter and adding devices to Zebra 4Sight XV6; for environmental and electrical specifications and connector pinout descriptions, refer to Appendix B: Technical information.

This product must be used as specified; otherwise, the protection provided by its components might be compromised. Any usage, changes, or modifications to Zebra equipment not expressly approved by Zebra could compromise product safety and void the user’s authority to operate the equipment.

•Refer to the Zebra 4Sight XV6 electrical specifications section, in Appendix B: Technical reference of the above-mentioned manual, for voltages and current ratings.

•To service the equipment, always turn off the unit and disconnect the main AC power before opening the unit. Always secure the equipment and close the chassis before reconnecting the main AC power.

•This product is a Class I equipment as per industry standards.

•This product is designed for use in a pollution degree 2 environment as per industry standards.

•This product is designed for indoor use only.

•This product is designed to operate at temperatures ranging from 0°C to 45°C at a non-condensing relative humidity of 10 to 90%.

•This product is not intended for use at altitudes exceeding 2000 m.

  • a. Note that these symbols might not necessarily be the same colour as depicted.
  • b. Manual available on the Zebra website at zebra.com/mv-manuals.
  • c. As per CAN/CSA-C22.2 No. 62368-1-14, ANSI/UL 62368-1-2014, EN 62368-1:2014 + A11:2017, IEC 62368-1:2014 (ed. 2.0).

Ergonomic Recommendations
To avoid or minimize the potential risk of ergonomic injury, always follow good ergonomic workplace practices. Consult with your local Health and Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.

Connecting to a LAN Network

Please note that this device is not tested or authorized to be connected via ethernet cable to a Local Area Network (LAN) in outdoor conditions. It may only be connected to an indoor LAN.

Marking and European Economic Area (EEA)

  • Statement of Compliance
    • Zebra hereby declares that this device complies with Directives 2014/30/EU, 2014/35/EU and 2011/65/EU.
    • The full text of the EU Declaration of Conformity is available at: zebra.com/doc.
    • EU Importer: Zebra Technologies B.V
    • Address: Mercurius 12, 8448 GX Heerenveen, Netherlands
  • Waste Electrical and Electronic Equipment (WEEE)
    For EU and UK Customers: For products at the end of their life, please refer to recycling/disposal advice at: zebra.com/weee.

FCC

United States and Canada Regulatory

Radio Frequency Interference Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference,
  2. this device must accept any interference received including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device under Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Radio Frequency Interference Requirements – Canada
Innovation, Science and Economic Development Canada ICES-003 Compliance Label: CAN ICES-003 ([A])/NMB-003([A])
This device complies with Innovation, Science and Economic Development Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference;
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

United Kingdom (Statement of Compliance)

  • Zebra hereby declares that this device complies with the Electromagnetic Compatibility Regulations 2016, the Electrical Equipment (Safety) Regulations 2016 and the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic
  • Equipment Regulations 2012.
  • The full text of the UK Declaration of Conformity is available at: zebra.com/doc.
  • UK Importer: Zebra Technologies Europe Limited
  • Address: Dukes Meadow, Millboard Rd, Bourne End, Buckinghamshire, SL8 5XF

Warranty

For the complete Zebra hardware product warranty statement, go to: zebra.com /mv-support.

Service Information

  • Before you use the unit, it must be configured to operate in your facility’s network and run your applications.
  • If you have a problem running your unit or using your equipment, contact your facility’s Technical or System Support. If there is a problem with the equipment, they will contact Zebra support at zebra.com/mv-support.
  • For the latest version of the guide, go to: zebra.com/mv-manuals.

Patent Information
This product may be protected by one or more patents. Patents: zebra.com/patents.

FAQ

  • Q: Where can I find the manual for the Zebra 4Sight XV6?
  • Q: What should I do with the product at the end of its life?
    • A: For EU and UK customers, refer to recycling/disposal advice at zebra.com/weee.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals