TARAMPS T-4400 Professional Amplifier 4x 100W RMS Power Instruction Manual

June 20, 2024
TARAMPS

TARAMPS logo T-4400 Professional Amplifier 4x 100W RMS Power
Instruction ManualTARAMPS T 4400 Professional Amplifier 4x 100W RMS
Power Instruction manual
T 4.400 ProAudio
PROFESSIONAL AMPLIFIER
4 x 100W RMS
The installation of this product must be done by a qualified professional.

Term of warranty

TARAMPS, located on Abilo Daguano Street 274, Res. Manuel Martins – Alfredo Macondo’s, SP – Brazil, ZIP CODE 19180-000, guarantees this product against any defects on terms of project, making, assembling, and/or with solidarity, due to project vices which cause it improper or inadequate to its original use within 12 months from the date of purchase. In case of defect during the warranty period, TARAMPS responsibility is limited to the repairing or substitution of the device of its own making.
This warranty excludes:

  • Damaged products by improper installation, water infiltration, violation by unauthorized individuals;
  • Tamper or torn warranty seal;
  • Cases in which the product is not used in adequate conditions;
  • Defects caused by accessories, modifications or features attached to the product;
  • The product with damage from falling, bumps or nature related problems (flooding, lightning, etc.);
  • Costs involving uninstallation, reinstallation of equipment as well as shipment to the factory;
  • Warranty card is not properly filled or torn;
  • Damage of any kind, due to problems in the product, as well as losses caused by discontinued use of the product.

Technical assistance

For international support, check on our website:
www.taramps.com.br/en/rede-de-assistencias- tecnicas or contact direct the factory support:
Phones: +55 18 3266-4050 / +55 18 99749-3391
E-mail: service@taramps.com.br

Introduction

Congratulations on your purchase of a Tramps product.
It was developed in a modern laboratory and with the latest technology.
This manual covers all features, operations and instructions to solve any doubt that may arise during the installation. Please take some time to read it carefully in order to ensure the proper installation and the use of all benefits that this  product can offer.
For questions, please call +55 (18) 3266-4050, e-mail support@taramps.com.br or visit www.taramps.com.br.

Safety requirements

-To ensure proper use, please read through this manual before using the amplifier. It is specially important that you know the CAUTIONS contained here.
– This amplifier must be installed in a firm place with at least 1” space around the heatsink for proper heat spreading.
– The installation of this amplifier must be done by a qualified professional.
– Never install the amplifier in places exposed to dust, humidity, water or heat sources.
– Do not open. This product is not user serviceable.
-Don’t block and not insert objects into the amplifier’s ventilation openings.
-Avoid to drop this amplifier, risk of damage.
-When in use, the top surface of the amplifier becomes hot. Avoid contact and keep the amplifier out of the reach of children.
-Unplug this apparatus during lightning storms or when unused for long periods of time.
-This amplifier can produce high sound pressure levels. Avoid continuous exposure to levels above 85dB to prevent hearing damage.
-Speaker output connections may have voltage levels when the amplifier is operating. Make sure the amplifier is OFF before proceeding with any connections or disconnections at these terminals.
-If you want to dispose of this amplifier, please do not throw it in household waste. It must be collected by a used electronics disposal service for proper recycling.
Safety
As you read this manual, pay attention to the safety symbols.
CAUTION
This symbol with “CAUTION” is intended to alert the user to the presence of important instructions. Failure to heed the instructions will result in risk of injury to user or product damage.
Front panel

TARAMPS T 4400 Professional Amplifier 4x 100W RMS Power - Front
panel

  1.  – 19″ RACK MOUNT HOLE: Use these holes to fix the T 4.400 on the rack.
  2. – VOLUME: Volume adjustment of the selected channel (A, B, C or D).
  3. – SIGNAL LED: Indicates the existence of an audio signal at the input of the channel in use on the amplifier (A, B, C or D).
  4.  – ON / OFF SWITCH: Turns amplifier power on and off.
  5. – CLIP LED: Flashing according to the song, it indicates that the amplifier is operating at the distortion threshold of the channel in use (A, B, C or D).

Rear panel

TARAMPS T 4400 Professional Amplifier 4x 100W RMS Power - Rear
panel

  1. AC POWER INPUT: Connect the cable to the AC mains. This product operates with 120V AC or 240V AC (automatic dual voltage).
  2. OUT C / D: Channel C and D power output for speakers. Follow the indicated polarity and recommended minimum impedance.
  3. OUT A / B: Channel A and B power output for speakers. Follow the indicated polarity and recommended minimum impedance.
  4. MODE KEY: Selects the type of connection to be used (Bridge, stereo or parallel).
  5. INPUT: Audio inputs (unbalanced) 1/4″ input.

Stereo connection example
1/4″ signal inputs: To connect audio mixer, equalizer, audio processor, receiver, etc…TARAMPS T 4400 Professional Amplifier 4x 100W RMS Power -
Stereo

Bridge connection example

TARAMPS T 4400 Professional Amplifier 4x 100W RMS Power -
Bridge

Parallel connection example

TARAMPS T 4400 Professional Amplifier 4x 100W RMS Power -
Parallel1

Mode: Bridge / Parallel
ATTENTION: If the connection is bridge or parallel, it is mandatory that the audio signal enters the A/C inputs as per the connection examples above.
Use the MODE switch to change the desired modes.
The front panel volume will be the same as the signal input (A/C).
CAUTION
Due to the presence of voltage at the output terminals when the product is on, avoid contact with them. Risk of electric shock.
Connect signals with amplifier volumes at minimum.
Connect the output cables only with the product off.
Connection to the AC mains
The wall power outlet must withstand the amplifier’s maximum current draw.

Technical features

Minimum Output Impedance:      2 Ohms Stereo / 4 Ohms bridge
Number of Channels: 4
Maximum power: 400W RMS ( 4 x 100W RMS) or ( 2 x 200W RMS)

IEC 60268-3*
Input sensitivity:| 775mV (0dBm)
Input Impedance:| 10K Ohms unbalanced
Signal-to-Noise Ratio:| >100dB
Frequency Response**:| 4Hz ~ 30KHz -3dB 2Ω Stereo
4Hz ~ 30KHz -3dB 4Ω Bridge
19Hz ~ 80KHz -3dB 4Ω Stereo
4Hz ~ 80KHz -3dB 8Ω Bridge
Crosstalk:| >63dB
THD+N:| <0,06%
Stand-by consumption:| 3,5W
Maximum consumption:| 500W
Supply voltage:| 127/220 VAC (Automatic bivolt)
Fuse| 6A
Protection| Short circuits outputs and low impedance
Dimensions (W x H x D):| 482 x 55 x 168mm (18.98″ x 2.17″ x 6.61″)
Weight:| 2,43Kg (5.35lb)

*Nominal power with 1KHz sinusoidal signal and 4 Ohms resistive load. (Measured according to IEC 60268-3 Sound Equipment, Part 3: Amplifiers).
**Frequency response measured at twice the minimum impedance.
Tramps reserves the right to modify the contents of this document at any time without prior notice and does not have the obligation to apply the changes in units which were previously produced.

TARAMPS logo +55 18 3266-4050
Fabric ado poor / Manufactured by:
TARAMPS ELECTRONICS LTDA ?
CNPJ/TAX ID: 11.273.485/0001-03 R. João Silverio, 121 Res.
Manuel Martins Alfredo Macondo’s – SP
Industrial Brasilia – Made in Brazil
www.taramps.com.br

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>