dellonda DG1.V2 Outdoor Garden Gas Patio Heater Instructions
- June 14, 2024
- dellonda
Table of Contents
dellonda DG1.V2 Outdoor Garden Gas Patio Heater
Model No. DG1.V2, DG2.V2
Thank you for purchasing a Dellonda product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
Specification
Model no’s | DG1.V2 DG2.V2 |
---|---|
Fuel consumption: | 928g/hr |
Fuel Type: | Propane |
Heated area: | 10m² |
Output: | 13kW |
Dimensions (W x H): | 810 x 2190mm |
Max. gas bottle size (W x H): | Ø325 x 700mm |
Product Depth (Front to Back): | 81cm |
Product Dimensions (W x D x H): | 810 x 810 x 2190mm |
Product Height (Floor to Top): | 219cm |
Product Width (Side to Side): | 81cm |
Weight: | 15Kg |
Introduction
The innovative design of radiant gas tower patio heater. This traditional freestanding patio heater produces a pleasant, heated working/relaxing environment and is ideal for both commercial and domestic settings including open workshops, boat yards, patios, forecourts, gardens, and terraces. The burner head is positioned approximately 2.19m off the ground and the metal reflector directs radiation downwards and outwards. Variable heat output controls make it fully adjustable. The unit features a fully enclosed gas cylinder chamber and a safety tip-over switch. Supplied with wheels for easy manoeuvrability, regulator and hose assembly for use with propane patio gas bottles and is available in black or stainless steel. This product should only be used in a well-ventilated area. Maximum Gas Bottle Size (W x H): Ø325 x 700mm. Some simple assembly is required.
Safety Instructions
- Read the installation, operating, and maintenance instructions thoroughly before installing or using this equipment.
- Keep the instructions for future reference.
- If there is a smell of gas: shut off the gas to the appliance and extinguish any open flames. If the odor continues contact the gas supplier.
- DO NOT store or use petrol or other flammable substances inside the housing of the heater.
- DO NOT store or use petrol or other flammable liquids or gases in the vicinity of the heater.
- DO NOT store a gas cylinder that is not connected for use in the vicinity of this or any other appliance.
- WARNING! DO NOT use indoors. For use outdoors or in amply ventilated areas.
- An amply ventilated area has a minimum of 25% of the surface area open, see fig.1.(The surface area is the sum of the wall surface).
- WARNING! Not intended to be installed in recreational vehicles and/or boats.
- WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
- Installation and repair must be carried out by a qualified person.
- This product must be installed and the gas cylinder stored by the local regulations in force.
- DO NOT obstruct the ventilation holes of the cylinder housing.
- DO NOT move/transport the appliance when in operation. Shut off the gas cylinder or the regulator before moving.
- DO NOT move/transport the heater until it has cooled down.
- Use only the type of gas and the type of cylinder specified by the manufacturer.
- The LP cylinder used with the patio heater must meet the following size requirements:
- Diameter 32.5cm x height 70cm, 15kg maximum capacity.
- Protect the product from strong wind to prevent tilting. In case of violent wind precautions must be taken against tilting of theappliance.
- Only use on level ground capable of withstanding the weight of the heater.
- DO NOT remove the injector (it is not removable). It is forbidden to convert the appliance from one gas pressure to another gas pressure.
- Use only the type of gas specified in the instructions.
- The whole gas system (hose, regulator, pilot, or burner) should be inspected for leaks or damage before use and at least annually, by a Sufficiently qualified person.
- DO NOT modify this product. Parts sealed by the manufacturer or his agent shall not be manipulated by the user.
- All leak testing should be done with a soap solution. Never use an open flame to check for leaks, refer to section ‘leakage test’.
- DO NOT use the heater until all connections have been leak tested.
- Turn off the gas immediately if a gas smell is detected. Turn the cylinder valve OFF. If the leak is at the hose/regulator connection tighten the connection and perform another leak test. If bubbles continue appearing contact your supplier. If the leak is at the regulator/cylinder connection disconnect from the cylinder, reconnect, and perform another leak check. If soap bubbles are still seen, the cylinder valve is defective. Return the cylinder to its place of purchase.
- Keep the ventilation opening of the cylinder enclosure free and clear of debris.
- Turn off the gas supply at the cylinder after use.
- DO NOT paint the radiant screen, control panel, or top canopy reflector.
- The control compartment, burner, and circulation air passageways of the heater must be kept clean.
- Turn off the gas whilst not in use.
- LP regulator/hose assembly must be protected from accidental damage.
- Any guard removed for servicing/maintenance must be replaced before operation.
- Keeps adults and children away from the high-temperature surface to avoid burns from ignition of clothing.
- WARNING! Accessible parts may be very hot. Keep young children away.
- Children should be carefully supervised when in the vicinity of the heater.
- DO NOT hang clothing or other flammable materials on the heater or place them near the heater.
- WARNING! Change the gas cylinder in an amply ventilated area, away from any ignition source (candle, cigarettes, other flame-producing appliances).
Gas Supply Installation
- Unscrew and remove the protective plug from the valve outlet if one is fitted on the gas cylinder.
- Check the bullnose connection on the regulator for any damage before connecting. Make sure the regulator is clear of any debris.
- Check the condition of the hose, especially at the nozzle end.
- Ensure the regulator is in the off position to allow the regulator to be fitted to the gas cylinder.
- Attach the regulator onto the gas cylinder, and pull the regulator upward to check the fitting is secure.
- To remove the regulator ensure the gas tap is in the off position. (Fig. 2). Press the release button, and lift the regulator off from the gas cylinder.
- Check the regulator seal at regular intervals. And is correctly fitted and able to fulfill its function.
- Read the instructions before installation.
- DO NOT connect the gas cylinder directly to the appliance without a regulator.
- The tubing or the flexible hose must be changed within the prescribed intervals.
- Use only the types of gas and the type of cylinder specified in these instructions.
- If the tubing shows signs of cracking, splitting or other deterioration it shall be exchanged for a new hose of the same length and of the equivalent quality.
- This appliance must be used, and the gas cylinder stored, by the regulations in force.
Regulator And Hose
- Only use regulators and hoses approved for LPG stated on the rating plate. The life expectancy of the regulator is estimated as 10 years. It is recommended that the regulator is changed within 10 years of the date of manufacture.
- This product is supplied with a propane regulator and hose assembly.
- The use of the wrong regulator or hose is unsafe; always check that you have the correct items before operating the appliance.
- The hose used must conform to the relevant standard for the country of use. The length of the hose must be 1.5 meters (maximum). The worn or damaged hose must be replaced. Ensure that the hose is not obstructed, kinked, or in contact with any part of the appliance other than at its connection. Change the hose when the national conditions require it.
- The hose should not be twisted or kinked when attached to the regulator and appliance.
- No part of the hose should touch any part of the appliance. Site the cylinder out to the left-hand side of the appliance at the maximum distance permitted by the hose length.
- Make sure the vent on a regulator does not point upwards or is installed in a position that allows the ingress of water, either by; rain, snow or any trickling or pooling. (If applicable).
- Protect from seawater spray unless the regulator is otherwise designed for this environment or is suitably protected.
- When the regulator (or change-over device) is used outdoors, it shall be positioned or protected against penetration by any trickling water.
- Orientation of any diaphragm vent to avoid any water accumulation on the atmospheric side of the diaphragm. If applicable.
Gas Regulator IGT 27mm Push type
Regulator marked to BS EN 16129 standard CE UK CA Regulator cannot be fitted
unless in the off position. Capacity 1.5kg/h Type.A127Inlet pressure minimum 1
bar maximum.16 bar. Propane 37mbar ∆ P2=2mbar.The downstream installation
pressure loss shall not exceed the ΔP value marked on the device.
For your safety
- DO NOT force a regulator onto the cylinder valve if it does not fit easily.
- DO NOT operate its mechanism using excessive force.
- DO NOT use regulators with US POL inlet fittings (designed for use on bulk storage vessels) with Cylinder valves (the threads may look the same, but they are different).
- Never tamper with the regulator.
- Never try to adjust non-user adjustable regulators, they are pre-set by the manufacturer to control the gas supply at the correct pressure, unless you are qualified to do so.
- DO NOT purchase or use a second-hand regulator.
GAS TYPE: | Propane |
---|---|
Inlet Pressure (bar) | 1 to 16 |
Normal Outlet Pressure (mbar) | 37 |
∆P2 (mbar) | 2 |
∆P5 (mbar) | N/A |
Working temperature | -20°C to 50°C |
Capacity | 1.5Kg/h |
Inlet connection | G52-20mm, G53-21mm, G54-22mm, G59-27mm, G61 |
Outlet connection | H50, H51, H53 |
Contents
Assembly
STEP 1
- Fix wheel bracket to base.
PART | DESCRIPTION | QTY |
---|---|---|
A | Reflector outer | 3 |
B | Reflector inner | 1 |
C | Burner head assembly | 1 |
D | Cylinder housing | 1 |
E | Main pole | 1 |
F | Gas hose | 1 |
FF | Reflector spacer | 3 |
G | Support leg | 3 |
H | Base | 1 |
I | Wheel kit | 1 |
STEP 2
Fix the 3 post brackets as shown. Use bolt BB to join post brackets to the
stand.
STEP 3
Fix the post to the 3 post brackets. Use bolts EE and nuts CC. Tighten nuts
and bolts.
STEP 4
Place the tank housing over the post.
STEP 5
- Remove four bolts from the base of the burner.
- Pass the gas hose down through the post.
- Fix the burner to the post, use bolt DD. Tighten nuts and bolts.
STEP 6
- Place large washers GG on the 3 reflector spacers FF.
STEP 7
- Fix the reflector onto the reflector spacers using 3 x wing nut KK.
STEP 8
- Raise the tank housing and rest it on the post plate. Be aware that it may fall if it is knocked.
- Connect the gas hose to the regulator.
- Place the LPG cylinder on the stand.
Operation
CONNECT GAS CYLINDER
-
Change the gas cylinder in an amply ventilated area, away fro many ignition sources (candles, cigarettes, other flame-producing appliances).
-
Lift the tank housing and prop it up on the top of the post brackets.
NOTE: In this instance, the housing can not be propped up on the top of the post brackets. A second person will be required to hold the tank housing up while the gas cylinder is fitted. -
Check the regulator seal. If damaged replace the regulator.
-
Use propane only.
-
Only use the hose and regulator supplied with the heater.
-
Never use a gas cylinder with a damaged valve or a damaged cylinder.
-
Never connect an unregulated cylinder to the heater.
GAS LEAKAGE
- In the event of gas leakage DO NOT use the heater. The gas supply should be shut off and the cause should be investigated before it is used again.
- Regulator ON position.
- Regulator OFF position.
- Regulator release button.
- Gas cylinder.
- Gas hose.
When attaching and detaching the regulator make sure the regulator gas tap is in the OFF position.
LEAKAGE TEST
- WARNING! Never perform leak test near sources of ignition.
- Gas connections are tested at the factory. A complete gas tightness check must be completed at the installation site prior to use.
- Make a solution of one part liquid detergent and one part water. The soap solution can be applied with spray bottle, brush or rag. Soap bubbles will appear at the site of a leak.
- Test must be performed with a full cylinder.
- Make sure the safety control valve is in the off position. Turn the gas supply on. In the case of a leak turn the gas supply off, re-tighten any fittings, then turn the gas supply on and re-check.
LOCATION OF HEATER refer to fig.3
- DANGER The use of this heater in enclosed areas is dangerous and is prohibited.
- Ensure that adequate fresh air ventilation is provided.
- Always maintain proper clearance from combustible materials, i.e top 1000mm and sides 1000mm minimum.
- Place on level solid ground.
- Never operate in an explosive atmosphere for example where explosive or flammable substances are stored.
- Protect from strong wind. Anchor securely to the ground with screws, refer to fig.3A.
TO TURN ON THE HEATER refer to fig.4
- Turn the cylinder valve fully on.
- Press in and turn the variable control knob to the PILOT position (counterclockwise 90°).
- Press down the variable control knob and hold in for 90 seconds. Whilst holding down the variable control knob, press the igniter button several times until the pilot flame lights. Variable control knob can be released after the pilot flame lights.
NOTE:
- If a new gas bottle has been connected, allow at least one minute for the air in the gas pipeline to purge out through the pilot hole.
- When lighting the pilot flame make sure the variable control knob is continuously pressed down, whilst pressing the igniter button.
- Variable control knob can be released after the pilot flame ignites.
- Pilot flame can be watched and checked from the small round window with the sliding lid, located at the bottom of the flame screen (to the left or right side of the controller).
- If the pilot flame does not light or goes out repeat the above paragraph.
- After the pilot flame lights, turn the variable flame knob to the maximum position and leave it there for 5 minutes or more before turning the knob to the desired position.
TO TURN OFF THE HEATER
- Turn the variable control knob to the pilot position.
- Push the knob in and move the knob to the off position.
- Turn off the valve on the cylinder completely.
CHECK HEATER IMMEDIATELY IF
- the heater does not reach temperature,
- the burner makes a popping noise during use (a slight noise is usual when the burner is extinguished).
- smell of gas in conjunction with the extremely yellow tip of the burner flame.
Storage
- Always turn off the gas valve on the gas cylinder after use.
- Disconnect the valve from the cylinder.
- Check the tightness of the gas valve. Check gas valve for damage.
- If damage is suspected have it inspected/changed by a gas stockist.
- DO NOT store a liquid gas cylinder in a cellar or in places without adequate air ventilation.
Maintenance
REGULATOR AND HOSE
- The use of wrong regulator or hose is unsafe, always check that you have the correct items before using the heater.
- The hose must conform to the relevant standard for the country of use. The length of hose must be 1.5 meters (maximum). Worn or damaged hose must be replaced. Ensure that the hose is not obstructed, kinked or in contact with any part of the heater other than its connection. Change the hose when national conditions require it.
- Check the hose at least once a month, each time the cylinder is changed, or after a period when the heater has not been used.
- If it shows signs of cracking, splitting or other deterioration it must be changed for a new hose of equivalent length and quality.
CLEANING
- Wipe surfaces with a soft, moist rag. DO NOT use combustible or corrosive cleaners.
- Remove debris from the burner to keep it safe for use.
- Cover the burner unit with the optional protective cover (Model no. DG179) when not in use.
Servicing
- Your gas appliance should be serviced annually by a competent registered person. Or contact the Dellonda service center at the contact details below.
Troubleshooting
PROBLEM | CAUSE | SOLUTION |
---|---|---|
Pilot will not light | Gas valve OFF | Turn gas valve on |
Gas cylinder empty | Renew cylinder | |
Opening blocked | Clean or replace the opening | |
Air in supply system | Purge air from lines | |
Loose connections | Tighten connections | |
Pilot will not stay on | Debris around pilot | Clean dirty area |
Loose connections | Tighten connections | |
Thermocouple faulty | Replace thermocouple | |
Gas leak in the line | Check connections | |
Lack of fuel pressure | Cylinder is nearly empty. Renew cylinder | |
Burner will not light | Pressure is low | Cylinder is nearly empty. Renew |
cylinder
Opening blocked| Remove and clean
Control not ON| Turn the valve to ON
Thermocouple faulty| Replace thermocouple
The pilot light assembly bent| Reposition pilot light
Not incorrect location (too windy)| Position properly and retry
Environment Protection, Waste Electrical and Waste Electronic Equipment Regulations (WEEE)
Recycle unwanted packaging materials. When this product is no longer required or has reached the end of its useful life, please dispose of in an environmentally friendly way. Drain any fluids (if applicable) into approved containers, per local waste regulations. Please note that this product contains one or more batteries. It is our policy to continually improve products and we reserve the right toalter data, specifications and parts without prior notice. No liability is accepted for incorrect use of this product. Guarantee is 12 months from purchase date, proof of which is required for any claim.
Dellonda Limited, the Sole UK Distributor of Baridi
Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
- 01284 757575
- support@dellonda.co.uk
- www.dellonda.co.uk