greenlite 82321 Advanced 5 Layer 15W Air Purifier Filter User Manual

June 13, 2024
greenlite

greenlite 82321 Advanced 5 Layer 15W Air Purifier Filter

greenlite 82321 Advanced 5 Layer 15W Air Purifier
Filter

IMPORTANT SAFETY INSTRUCTIONS

IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS, OR PROPERTY, PLEASE FOLLOW THE FOLLOWING SAFETY PRECAUTIONS:

If the power cord or unit does not work, contact Green lite customer service immediately.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURYTO PERSONS:

  • Unplug or disconnect the air purifier from the power supply if the plug is not working.
  • DO NOT touch the power plug with wet hands.
  • Turn off the power before cleaning the unit.
  • DO NOT take apart or modify the unit without authorization.
  • BEFORE USING THIS PRODUCT, PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM THE FILTER.
  • Indoor and household use only.
  • DO NOT place other items on top of the appliance. Sitting or standing on this appliance is forbidden.
  • DO NOT insert the fingers or objects into the air inlets or air outlets to prevent the product from physical damages or malfunction.
  • This appliance cannot replace natural ventilation and other appliances like the vacuum cleaner, kitchen ventilator, etc.
  • When the appliance is working, it must be placed on a dry, flat and stable floor, with at least 50cm space reserved around it.
  • DO NOT put it in a place with direct sunlight.
  • To prevent electromagnetic disturbance, the appliance must keep a certain distance from the TV, radio, microwave oven and others.
  • WARNING : To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid any type of hazard. Children shall not play with the appliance. Cleaning and maintenance of the unit shall not be made by children without supervision. Prior to cleaning or doing any type of maintenance, the appliance must be disconnected from the supply.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.

TECHNICAL DATA

  • Input : 100-240VAC, 50/60Hz, 0.5A
  • Output : 24Vdc, 0.75A
  • Rating Power : 15.6W
  • Noise level : 50 dBA
  • Room size : up to 158 sq. ft.
  • Unit dimensions : 8.09″W x 8.09″0 x12.2″H
  • Unit weight : 4.41 lbs.

PRODUCT INFORMATION

NO. Description
1 Display Screen
2 Air Outlet Grill
3 Adapter Cable
4 HEPA Filter
5 Base Plate

Product Information

INSTALLATION STEPS

  1. Place the unit in a dry location and on a flat surface.
    To ensure enough ventilation, make sure that there is a 20″ (50 cm) distance between the unit and the wall or nearby furniture. This will promote enough ventilation and high efficiency.

  2. Rotate the base counter-clockwise.

  3. Take out the preinstalled HEPA filter.

  4. Remove the plastic covering from the filter.

  5. Install the new HEPA filter back in the unit.

  6. Reattach the base at the bottom of the unit (with the filter inside). Rotate the base clockwise to secure it.

  7. Insert the adapter cable into the air purifier.

  8. Insert the plug into a power source. Unit lights will flash for 1 second. Unit lights will turn off and the air purifier will be on standby mode.

  9. Press the On / Standby Button
    The air purifier will enter into the Auto Mode when it is powered for the first time.

ATTENTION

Remove all plastic packaging from the filter before installing it.
DO NOT run the air purifier if there is no filter installed.
Please be careful when installing the back cover. Watch your hands.

CONTROL PANEL

Control Panel

IconTIMER

When the air purifier is turned on, the timer is off by default.
Press the timer button once to set the timer for 2 hours.
The 2-hour indicator light will turn on.
Press twice to set the timer for 4 hours. The 4-hour indicator light will turn on.
Press three times to set the timer for 8 hours. The 8-hour indicator light will turn on.
Press 4 times to turn off the timer.

IconFAN SPEED

When the air purifier is turned on, the fan speed is set to low speed by default.
Press the fan speed button once to set it to MEDIUM speed. The medium speed indicator light will turn on.
Press twice to set it to HIGH speed. The high speed indicator light will turn on.
Press once again to set to LOW speed. The low speed indicator light will turn on.

CHILD LOCK

To activate the child lock, press and hold the fan button for 4 seconds.
To deactivate the child lock, press and hold the fan button again for 4 seconds.

FILTER RESET

When the filter expires, the filter reset indicator light will turn red.
After replacing the old filter, press and hold the timer button to reset the filter.

CLEANING AND MAINTENANCE

Disconnect the power plug before cleaning the unit. Do not put the unit in water or in any other liquid. Do not use abrasive, corrosive or flammable products to clean any parts of the unit. Filters cannot be washed.

CLEANING THE AIR PURIFIER

Cleaning the housing and inlet of the air purifier

Use a soft and dry cloth to remove the dust from the air purifier.
Cleaning The Air Purifier

Cleaning the inside of the air purifier

Cleaning The Air Purifier

Turn off the power and unplug the air purifier. Rotate the base counter- clockwise and take out the HEPA filter. Use a soft and dry cloth to clean the inside of the air purifier.

Cleaning the outlet of the air purifier

Use a soft and dry cloth to clean the outlet of the air purifier.
Cleaning The Air Purifier

CLEANING THE FILTER

  1. Turn off the power and unplug the air purifier. Take out the HEPA filter.

  2. Use a soft and dry cloth to clean the filter.
    Cleaning The Filter

  3. Reattach the base at the bottom of the unit with the filter inside. Rotate the base clockwise to secure it.
    Cleaning The Filter

  4. Insert the plug into a power source.

FILTER REPLACEMENT

LIGHT INDICATOR TO REPLACE THE FILTER

The unit will remind the user when the filter is due to be replaced. Filters should be replaced every 3-6 months depending on usage. The filter change indicator light will let you know when you have reached that time.

The filter change indicator light will turn red to alert the user when the filter is due to be replaced.

Remove old filter and replace with only a Greenlite G-Pure-15W HEPA filter.
To purchase replacement filters, visit www.greenliteusa.com

Filter Replacement

Press and hold the filter reset button for 3 seconds to reset the HEPA filter.

WARRANTY

This product is warranted to be free from defects in workmanship and material for 1 year. If it fails to do so, Greenlite™ will, at its election, provide a replacement or equivalent upon receipt of the register receipt and proof of purchase. Please visit www.greenliteusa.com to find out how to initiate a warranty claim. This limited warranty does not cover bulbs subject to accident, neglect, abuse, misuse or acts of God. Replacement or refund is your sole remedy.
For all inquiries, please contact our customer service team at: [email protected] or 1-844-695-9090 from 9:00 AM to 5:00 PM EST.

Symbols

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

greenlite User Manuals

Related Manuals