Blue-White F-2000 MD1 Multi Diaphragm Metering Pump Instruction Manual

June 13, 2024
Blue-White

Blue-White-LOGO

Blue-White F-2000 MD1 Multi Diaphragm Metering Pump

Specifications :

  • Maximum Working Pressure:
  • Maximum Fluid Temperature:
  • Maximum Viscosity:
  • Maximum Suction Lift:
  • Ambient Operating Temperature:
  • Ambient Storage Temperature:
  • Operating Voltage:
  • Power Cord Options:
  • Motor Duty Cycle:
  • Motor Speed Adjustment Range:
  • Enclosure Maximum Overall Dimensions:
  • Product Weight:
  • Approximate Shipping Weight:
  • Approximate Shipping Dimensions:

Product Usage Instructions

Installation

  1. Mounting Location: Choose a suitable location for mounting the pump where it is easily accessible and level.
  2. Pump Dimensions: Refer to the user manual for detailed pump dimensions to ensure proper installation space.
  3. Wall Mounting: Use the provided wall mounting bracket to securely mount the pump.
  4. Power Connections: Connect the power cord to a suitable power source following electrical safety guidelines.
  5. Input / Output Connections: Make sure to connect the input and output lines properly according to the user manual.
  6. M12 Connections: Use M12 connectors for input/output communications if required, ensuring IP67 protection.

Pump Operation

  1. Priming the Pump: Follow the priming instructions provided in the manual to ensure proper pump operation.
  2. Manual Speed/Flow Adjust: Adjust the speed or flow manually as needed based on your application requirements.
  3. 4-20ma Speed/Flow Control: Utilize the 4-20mA input for precise speed or flow control if necessary.

Outputs

  • Motor ON: Monitor the motor status to ensure it is functioning correctly.
  • Relay (FVS and TFD): Check the relay status for flow verification sensor and diaphragm failure detection.
  • 4-20mA Output: Use the 4-20mA output for external monitoring or control purposes as required.

Pump Maintenance

  1. Routine Inspection and Maintenance: Regularly inspect and maintain the pump according to the maintenance schedule outlined in the manual.
  2. Cleaning and Lubricating the Pump: Clean and lubricate the pump components following the specified guidelines to ensure longevity.

Frequently Asked Questions (FAQ):

  • Q: Does the pump come with suction or discharge tubing?
    A: No, the MD1 Pump does not ship with suction or discharge tubing due to NSF61 requirements. These need to be ordered separately.

  • Q: What certifications does the pump have?
    A: The pump is ETL listed and conforms to UL Standard 778 as a motor-operated water pump and CSA Standard C22.2 as process control equipment.

CHEM-FEED®
Multi-Diaphragm Metering Pump

Series MD1

READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE.

INTRODUCTION

Congratulations on purchasing the MD1 variable speed Multi-Diaphragm Metering Pump.
Please Note: Your new pump has been pressure tested at the factory with clean water before shipping.

Available Models

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(140\)

What’s In The Box

  • MD1 Multi-Diaphragm Pump with Cover
  • Instruction Manual
  • Wall Mounting Bracket

Parts Kit

  • Injection Fitting
  • Foot Valve
  • Screws
  • Ceramic Weight
  • Tube Nuts

Note : The MD1 Pump does not ship with suction or discharge tubing (per NSF61 requirements). Order these separately. See Accessories pages for details.

ENGINEERING SPECIFICATIONS

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(40\)Blue-White-F-2000-MD1-Multi-Diaphragm-
Metering-Pump- \(41\)Blue-White-F-2000-MD1
-Multi-Diaphragm-Metering-Pump- \(1\)Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(42\)CONSTRUCTION MATERIALS

Wetted Components

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(43\) Blue-White-F-2000-MD1-Multi-
Diaphragm-Metering-Pump- \(44\)

Non-wetted Components

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(45\)

FEATURES

  •  Smooth chemical dosing, no pulsation dampener needed.
  • Automatic Degassing Valve (ADV) System reduced the risk of vapor lock.
  • Diaphragm Failure Detection (DFD) system which senses diaphragm failure.
  • Rated for continuous duty.
  • Compatible with Blue-White Industries, Flow Verification Sensor (FVS) system.
  • Remote Start/Stop – One non-powered dry contact closure.
  • Speed Control: Manual Speed Adjust and Scalable 4-20ma Input
  • Outputs: 4-20mA, single 250V/3A (FVS, DFD), and a solid state “motor on” (0-60 VDC sinking)
  • Multi diaphragm metering with industry best turndown at 10,000:1 (Brushless DC Motor)
  • Built for long life at high pressures up to 150 PSI (10.3 bar)
  • Output rates up to 8.50 GPH (32.2 LPH) @ 0 PSI, 8.34 GPH (31.6 LPH) @ 30 PSI, 7.50 GPH (28.4 LPH) @ 150 PSI.
  • Convenient M12 Connectors (IP67) for Input/Output Communications. (M12 cables ordered separately)

Agency Listings

  • Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(3\) This pump is ETL listed to conforms to the following: UL Standard 778 as a motor operated water pump. CSA Standard C22.2 as process control equipment
  • This pump complies to the Machinery Directive 2006/42/EC, BS, EN 60204-1, Low Voltage Directive 2014/35/EU BS EN 61010-1, EMC Directive 2014/30/EU, BS EN 50081-1/BS EN 50082-1.
  • This pump is certified to NSF/ANSI Standard 61- Drinking Water System Components – Health Effects

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(46\)

  • NEMA
    • 4X Constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation of ice on enclosure.
  • IP66
    • No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure from any direction shall have no harmful effects.

INSTALLATION

  • CAUTION
  • The pump should be serviced by qualified persons only. If equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired.
  • CAUTION
  • Always wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on solution being pumped. Refer to MSDS precautions from your solution supplier.
  • CAUTION
  • All diagrams are strictly for guideline purposes only. Always consult an expert before installing metering pump on specialized systems. Metering pump should be serviced by qualified persons only.
  • CAUTION
  • Check system pressure and piping pressure limits before installation.
  • If using pump with chemicals that off-gas (i.e. sodium hypochlorite), do not leave chemicals in pump or between valves for excessive periods of non-use. Flush pump as necessary.
  • CAUTION
  • The pump should be supplied by an isolating transformer or RCD (operating current less or equal 30 mA).

Mounting Location

  1.  The pump must be sheltered from environment (rain, snow, direct sunlight, etc.) Do not place pump on floor or in location with excessive chemical spills or vapors.

  2.  Choose an area located near the chemical supply tank, chemical injection point, and electrical supply. Also, choose an area where the pump can be easily serviced.
    NOTE: Suction and Discharge manifolds can be removed and rotated so the suction and/or discharge connections are on opposite sides. Pump performance will not be affected by suction or discharge location. For best De-gassing and Priming efficiency, locate suction connection on same side as degassing cart.

  3. Finding a secure surface and using the provided mounting hardware, mount the pump close to the injection point. Keep the inlet (suction) and outlet (discharge) tubing as short as possible. Longer discharge tubing increases back pressure at pump head.

    • NOTE: Mounting the pump lower than the chemical container will gravity-feed chemical into it. This “flooded suction” installation will reduce output error due to increased suction lift. A shut-off valve, pinch-clamp, or other means to halt gravity-feed to the pump must be installed during servicing.
    • NOTE: Install a back flow prevention check valve at the discharge side of the pump to prevent the system fluid from flowing back through pump during maintenance.
    • NOTE: It is recommended to have a pressure relief valve at the discharge side of the of pump to prevent premature wear and damage to the pump, in the event that the discharge line becomes blocked.
    • NOTE: The pump does not require back pressure. Back-pressure valve may be desired to maintain consistent flow into inconsistent system pressure.

 Pump Dimensions

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(7\)

Wall Mounting

  1.  Using the provided #10 self-tapping screws, mount the bracket to a secure wall that is located where it can be easily serviced.Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(9\)
  2. Lower the pump so that the tab on the wall mount is inserted into the slot located on the back of the pump. The pump will now be secured to the wall mount bracket. To remove pump, pull tab and lift pump.Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(10\)
    • Wall Mount (Side View)
    • Mounted Pump

POWER CONNECTIONS

  • WARNING
    Risk of electric shock – cord connected models are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

  • WARNING
    Electrical connections and grounding (earthing) must conform to local wiring codes.

  • WARNING
    Risk of electric shock – Disconnect electricity before removing wiring compartment cover.

  • WARNING
    Ensure to connect the pump to the proper supply voltage. Using the incorrect voltage will damage the pump and may result in injury. The voltage requirements is printed on the pump serial label.

  • Use the voltage for which the power cord is rated.

  • To prevent electronic noise interference, electronic signal wires and AC power wires must be kept separate. Do not bundle these cables together or run within the same conduit.

  • When there is a power interruption, the pump will restart (resume) in the same state as prior to power interrup-tion.

  • POWER: 115V60Hz (0.6A max.), 220V50Hz (0.3A max.), 230V60Hz (0.3A max.), 230V50Hz (0.3A max.), 240V50Hz (0.3A max.)

  • COVERS FOR USB CONNECTION AND M12 CONNECTIONS MUST BE IN PLACE WHEN NOT CONNECTED TO CABLES

NOTE: When in doubt regarding your electrical installation, contact a licensed electrician.Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(8\)Pump (Right Side Panel)
IO Connection

  • WARNING
  • Risk of electric shock – All wiring must be insulated and rated 60V minimum.
  • COVERS FOR USB CONNECTION AND M12 CONNECTIONS MUST BE IN PLACE WHEN NOT CONNECTED TO CABLES (Failure to keep connectors in place may void warranty)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(47\)

  • M12 cables not included with product. See accessories for cable options. Blue-White requires any A-Type M12 connector with 5 position female sockets

M12 Connections

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(13\)

M12 Input Connector I/O 1

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(48\)

P2 4-20mA Input (-) 120 Ohm Impedance, Non powered (-) Negative
P3 4-20mA Output (+) 250 Ohm Max Load (+) Positive
P4 4-20mA Output (-) DC GND (0 VDC) (-) Negative
P5 Not Used

M12 Input Connector I/O 2

PIN| Function| Specifications| Reference
P1| Remote Start / Stop| Dry Contact Closure (Do Not add voltage)| Green Light = Normally Open Red Light = Normally Closed
P2| Ground| DC Ground| 0 VDC
P3| FVS (+)| 15 VDC @ 60 mA| To power FVS sensor
P4| FVS (-)| DC Ground (0 VDC)| FVS Ground Input
P5| FVS (Signal)| Input Signal| Input for FVS Signal

M12 Output Connector I/O 3

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(49\)

TOUCHPAD LAYOUT

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(14\)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(50\)

SET-UP AND PROGRAMMING

Remote Start/Stop

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(15\)

Item Number Directions for Normally Open Operation
1 Confirm that pump is in the OFF position
2 Press Remote Start/Stop button to activate
3 Light will turn Green for “Normally Open” Operation
4 To put pump is Ready state, press Start/Stop button
5 Display will show “SbY” when waiting for contact closure signal
6 Display will show pump speed (or RPM, 4-20ma) when signal is closed
Item Number Directions for Normally Closed Operation
--- ---
1 Confirm that pump is in the OFF position, and Remote Start/Stop light is

off
2| Press and hold Remote Start/Stop button for 5-7 seconds
3| Light will turn Red for “Normally Closed” Operation
4| To put pump is Ready state, press Start/Stop button
5| Display will show “SbY” when waiting for contact closure to Open
6| Display will show pump speed (or RPM, 4-20mA) when signal is Open

Programming FVS (Flow Verification Sensor)
Flow Verification System (FVS) uses a pulse signal from flow meter/sensor. When the FVS feature is activated, if running pump does not receive signal/pulse in the programmed delay time, the pump will stop and activate Alarm Output Relay. Display will read “FuS”. (Contact Blue-White for FVS sensor options. )

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(16\)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(51\)

Activate by pressing FVS button once. Light On indicates activation. Press again to de-activate.
NOTE: Alarm Delay Time range 1-20 seconds

Pump Lockout
Pump Lockout feature allows the user to “lock out” the ability to change pump controls, such as Pump Speed, Prime, FVS, Remote Start/Stop, Manual/4-20ma Modes. User will still be able to start and stop the pump .Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(17\)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(52\)

4-20MA INPUT

Selecting 4-20mA input mode

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(18\)

Programming 4-20mA input mode Blue-White-F-2000-MD1-Multi-Diaphragm-
Metering-Pump- \(19\)

PUMP OPERATION

  1. Priming The Pump

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(20\)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(55\)

Need help calibrating your pump? Click on … or scan the QR code.

Manual Speed/Flow Adjust
Pump speed can be adjusted manually using “Manual Adjust” Run Mode.

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(22\)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(56\)

4-20 Input Speed/Flow Control
Pump speed can be adjusted remotely using “4-20ma Input” Run Mode.

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(23\)

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(57\)

 OUTPUTS

  • MOTOR ON – Active when motor is running in Manual or 4-20ma Mode.
  • RELAY OUTPUT – Active when either DFD or FVS has triggered. Stop pump to reset. 4-2mA
  • OUTPUT – Non-scalable full scale output proportional to pump speed.

DFD (DIAPHRAGM FAILURE DETECTION)

  • The MD1 is equipped with a Diaphragm Failure Detection System which is designed to stop pump and provide an output alarm in event diaphragm should rupture and chemical enters pump head.
  • This system is capable of detecting presence of a large number of chemicals including Sodium Hypochlorite (Chlorine), Hydrochloric (muriatic) Acid, Sodium Hydroxide, and many others. System will not be triggered by water (rain, condensation, etc.) or lubricants.
  • If DFD alarm occurs, pump will stop, close an alarm output, and screen will flash DFD with an alarm icon.
  • If system has detected chemical, pump diaphragm must be replaced and pump head must be thoroughly cleaned. To clean the DFD pins, remove cover on bottom of drive chamber by removing two screws. You can now clean the pins in this area. (pump may need to be removed from mounting bracket for better access .Failure to clean pump head will void warranty.

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(24\)

 PUMP MAINTENANCE

  • CAUTION
    Prior to service, pump clean water through pump and suction / discharge line to remove chemical.

  • CAUTION
    Always wear protective clothing, face shield, safety glasses and gloves when working on or near your metering pump. Additional precautions should be taken depending on solution being pumped. Refer to MSDS precautions from your solution supplier.

Routine Inspection and Maintenance

  • Pump requires very little maintenance. However, pump and all accessories should be checked weekly. This is especially important when pumping chemicals. Inspect all components for signs of leaking, swelling, cracking, discoloration or corrosion. Replace worn or damaged components immediately.
  • Cracking, crazing, discoloration during first week of operation are signs of severe chemical attack. If this occurs, immediately remove chemical from pump. Determine which parts are being attacked and replace them with parts that have been manufactured using more suitable materials. Manufacturer does not assume responsibility for damage to pump that has been caused by chemical attack.

Cleaning Pump

Pump will require occasional cleaning, especially Injection fitting, Footvalve / Strainer, and pump head valves. Frequency will depend on type and severity of service.

  • Inspect and replace pump head valves as required.
  • Periodically clean injection / check valve assembly, especially when injecting fluids that calcify such as sodium hypochlorite. These lime deposits and other build ups can clog fitting, increase back pressure and interfere with check valve operation.
  • Periodically clean suction strainer.
  • Periodically inspect pump housing (enclosure) for chemical attack. Protect pump housing from continuous exposure to chemicals, such as drips or fumes from surrounding equipment and plumbing.

Replacing the Pump Diaphragm

  • When changing the diaphragm, the pump head chamber and pump head cover should be wiped free of any dirt and debris. The pump stroke must be FORWARD when installing the diaphragm (hand tighten), and BACK when installing and tightening the pump head. Tighten screws on pump head evenly and incrementally. Final tightening to be done with a torque wrench rating at 20 in-lbs. Once the pump has been fully reassembled, allow the pump to run for 24 hours then go back and re-torque the screws to 20 in-lbs.
  • When replacing the pump diaphragm, note the order of parts per the illustration below:Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(25\)

Updating The Firmware

REQUIREMENTS: Download & Install the MD1 Programmer file by visiting the Firmware Update section of the MD1 product page at www.blue- white.com as well as download the Firmware Update File.

  1. Connect the Pump to a computer via USB-A / USB-C cable (Pump must not be powered before starting.) (Be sure to replace USB cover after updating firmware)
  2. Power up the Pump
  3. Open the MD1 programmer
  4. Select “Enable” USB in the Communication settings window
  5. Click on ConnectBlue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(26\)

Watch this Video for further assistance.Blue-White-F-2000-MD1-Multi-
Diaphragm-Metering-Pump- \(27\)

Select “Load Hex File” Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(28\)

Select “.HEX” file (See Blue-White website for latest firmware version) Click on “Erase-Program-Verify” Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-
Pump- \(30\)

  • Once Hex file is loaded successfully
  • Click on “Disconnect”. Your firmware has now been updated.

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(31\)

REPLACEMENT PARTS LIST

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(58\)

 EXPLODED VIEW

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(10\)

ACCESSORIES

  • KIT-M12
    • Kit contains: Two M12 cables. 10 foot length. Other cable lengths:
    • KIT-M12-2-15 15 foot length.
    • KIT-M12-2-30 30 foot length.
  • KIT-M12-3
    • Kit contains: Three M12 cables. 10 foot length. Other cable lengths:
    • KIT-M12-3-15 15 foot length.
    • KIT-M12-3-30 30 foot length.

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(35\)

  • CABLE-UAC
    Kit contains: One 3’ USB-A to USB-C cable.

  • POWER CORDS – DETACHABLE

    • 90010-663 115V/60Hz NEMA 5/15
    • 90010-664 220V/50Hz CEE 7/V11
    • 90010-665 230V/50Hz BS 1363/A
    • 90010-666 240V/50Hz AS 3112
    • 90010-696 230V/60Hz NEMA 6/15
    • 90010-821 115V/60Hz NEMA 5/15 (Lockable)
  • KIT-CQA (Aflas O-rings) / KIT-CQE (EP O-rings)

    • Kit contains: One discharge fitting with o-rings installed (red),One suction fitting with o-rings installed (white), Two tube nuts, Two 1/2” hose barb quick connect adapters, Two 1/2” M/NPT quick connect adapters, Two quick disconnect adapters and Two #5 hose clamps. Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(33\)
  • KIT-C5M

    • Kit contains : Two 1/2” MNPT adapters with integral union nuts.
  • KIT-C5B

    • Kit contains : Two union nuts, Two 1/2” hose barb adapters, Two #5 hose clamps, One 2 1/2’ clear reinforced PVC tube and One 5’ 5/8” suction tube
  • ELBOW ADAPTER KITS (Kits include (2) adapters, (2) Union Nuts, (2) O-rings)

    • KIT-CA1SE Elbow Adapter Kit, 1/4” x 3/8” tubing connection, Aflas O-rings
    • KIT-CE1SE Elbow Adapter Kit, 1/4” x 3/8” tubing connection, EP O-rings
    • KIT-CA1ME Elbow Adapter Kit, 1/2” M/NPT connection, Aflas O-rings
    • KIT-CE1ME Elbow Adapter Kit, 1/2” M/NPT connection, EP O-rings
    • KIT-CA1BE Elbow Adapter Kit, 1/2” Hose Barb connection, Aflas O-rings
    • KIT-CE1BE Elbow Adapter Kit, 1/2” Hose Barb connection, EP O-rings
  • SUCTION AND DISCHARGE TUBING

    • C-334-6 Tubing, Suction, clear PVC 3/8” O.D. x 5’ length
    • C-334-6-10 Tubing, Suction, clear PVC 3/8” O.D. x 10’ length
    • C-334-6-100 Tubing, Suction, clear PVC 3/8” O.D. x 100’ length
    • C-335-6 Tubing, Discharge, opaque PE 3/8” O.D. x 5’ length
    • C-335-6-10 Tubing, Discharge, opaque PE 3/8” O.D. x 10’ length
    • C-335-6-100 Tubing, Discharge, opaque PE 3/8” O.D. x 100’ length
  • KIT-S07

    •  Kit contains: One 7 gallon tank, One foot valve and strainer and One mounting bracket with screws Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump- \(36\)
  • KIT-S15

    • Kit contains: One 15 gallon tank, One foot valve and strainer and One mounting bracket with screws
  • KIT-S30

    • Kit contains: One 30 gallon tank, One foot valve and strainer and One mounting bracket with screws
  • KIT-PSM

    • Kit contains: One HDPE Bracket, (4) 3/8” x 2-3/4” long dia anchor bolts.

 TROUBLESHOOTING

Error Code Explanation Troubleshooting
E01 Motor Over Current Ensure that diaphragm is installed properly
E02 Over Voltage Check power supply output voltage
E03 Under Voltage Check power supply output voltage
E04 Temperature exceeds 75°C at control Check ambient conditions,

restart pump once cooled to ambient temperature
E05| Inverter Error| Contact Blue-White 714-893-8529 customerservice@blue- white.com
E06| No Motor Connection| Contact Blue-White 714-893-8529 customerservice@blue- white.com
E08| Motor Stall| Ensure that diaphragm is installed properly
E10| Capacitor bank charging error| Contact Blue-White 714-893-8529 customerservice@blue- white.com
E17| Communication error at display| Contact Blue-White 714-893-8529 customerservice@blue- white.com

WARRANTY

  • Limited Warranty
  • Your Blue-White product is a quality product and is warranted for a specific time from date of purchase (proof of purchase is required). The product will be repaired or replaced at our discretion. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the product manual. Warranty status is determined by the product’s serial label and the sales invoice or receipt. The serial label must be on the product and legible. The warranty status of the product will be verified by Blue-White or a factory authorized service center.
  • CHEM-FEED® MD1 pumps are warranted for 5 years from date of purchase (proof of purchase is required). Pumps will be repaired or replaced at our discretion.

DIAFLEX® Warranty

  • DIAFLEX® diaphragms are warranted for the life of the pump. Blue-White will replace a damaged diaphragm at no cost to the customer provided the pump was at all times operated within the guidelines included in the pump’s operation manual. This warranty only applies to DIAFLEX® diaphragms, not the pumps themselves. Blue-White pumps are separately covered by warranties specific to them.
  • What is not Covered
    • Flex-A-Prene diaphragm and rubber components – They are perishable and require periodic replacement
    • Pump removal, or re-installation, and any related labor charge.
    • Freight to the factory, or service center
    • Pumps that have been tampered with, or in pieces.
    • Damage to the pump that results from misuse, carelessness (such as chemical spills on the enclosure), abuse, lack of maintenance, or alteration that is out of Blue-White control.
    • Pumps damaged by faulty wiring, power surges, or acts of nature.
  • Blue-White does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of the use of its products. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the pump operation manual.
  • The warranty status is determined by the pump’s serial label and the sales invoice or receipt. The serial label must be on the pump and be legible. The warranty status of the pump will be verified by Blue-White or a factory authorized service center.
  • Procedure for In-Warranty Repair
    Warranty service must be performed by the factory or an authorized service center. Contact the factory or local repair center to obtain a RMA (Return Material Authorization) number. It is recommended to include foot strainer and injection/check valve fitting since these devices may be clogged and part of the problem. Decontaminate, dry, and carefully pack the product to be repaired. Please enclose a brief description of the problem and proof of purchase. Prepay all shipping and insurance cost. COD shipments will not be accepted. Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair is completed, the factory pays for return shipping to the dealer or customer.

Product Use Warning

  • Blue-White products are manufactured to meet the highest quality standards in the industry. Each product instruction manual includes a description of the associated product warranty and provides the user with important safety information. Purchasers, installers, and operators of Blue-White products should take the time to inform themselves about the safe operation of these products. In addition, Customers are expected to do their own due diligence regarding which products and materials are best suited for their intended applications. Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific application as Blue-White does not have the same degree of familiarity with the application that the customer/end user has. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT
  • BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.

Chemical Resistance Warning

  • Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well informed and aware of the precautions to be taken when injecting or measuring various chemicals, especially those considered to be irritants, contaminants or hazardous. Customers are expected to do their own due diligence regarding which products and materials are best suited for their applications, particularly as it may relate to the potential effects of certain chemicals on Blue-White products and the potential for adverse chemical interactions.
  • Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was supplied to Blue-White by reputable sources, but Blue-
  • White is not able to vouch for the accuracy or completeness thereof. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties.
  • BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN CONNECTION WITH ANY BLUE-WHITE PRODUCTS.

ACRONYMS

°C Celsius mL Milliliters
°F Fahrenheit MSDS Material Safety Data Sheet
AC Alternating current N.C. Normally Close
bar Unit of pressure N.O. Normally Open
CIP Clean-in-place NPT National Pipe Thread
cm Centimeters NSF National Sanitation Foundation
COD Cash on Delivery OD Outside diameter
D Depth P.N. Part Number
DC Direct current PBT Polybutylene Terephthalate
DFD Diaphragm Failure Detection PE Polyethylene
EEE Electrical and electronic equipment PSI Pounds per Square Inch
EP Ethylene propylene PVC Polyvinyl chloride
ETL Electrical Testing Labs/Intertek PVDF Polyvinylidene fluoride
EU European Union RCD Residual-current device
FDA Food and Drug Administration Rev. Revision
FKM Fluor elastomer RMA Return Material Authorization
FVS Flow Verification Sensor RPM Revolutions per minute
GF Glass fiber SIP Steam-in-place
GPD Gallons per day SS Solid state
GPH Gallons per hour TFD Tube Failure Detection
H Height TFE/P Tetrafluoroethylene propylene
Hz Inside diameter UL Underwriters Laboratories
IO Input/Output US United States
Kg Kilogram V Volt
lb. Pound W Watt
LLDPE Linear low-density polyethylene W Width
LPH Liters per hour WEEE Waste Electrical and Electronic
mA Milliampere Equipment

Model Number Matrix

Blue-White-F-2000-MD1-Multi-Diaphragm-Metering-Pump-
\(59\)

NOTES

  • Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. Appliances are labeled in accordance with
  • European Directive 2002/96/EC.
  • Contact your local waste recovery agency for a Designated Collection Facility in your area.
  • 5300 Business Drive Huntington Beach, CA 92649 USA P.N. 80000-614
  • TEL: 714-893-8529
  • FAX: 714-894-9492
  • www.blue-white.com