Product Description
Introduction
Environmental sensors offer 4 functions; remote temperature measuring, motion detection, error reporting and an external remote or boost switch connection. All functions are fully programmable and can be associated with any heaters in the system. Up to two environmental sensors can be connected to the heaters when used together with a CHMC controller. Each system can have a maximum of 8 heaters. Please see page 6 of CHMC instructions for further details.
Installing the CHES
The CHES is supplied with a small power supply (CHPWR). This power supply must be powered directly by the internal wiring of the heater. On the CH06CPiRX and the CH09iRX models, the power supply can be connected directly to the spare tags on the main heater PCB. On the CH06CSiRX and CH12iRX models, these tags are not available, so the power supply must be connected to the internal wiring using WAGOs or similar connection blocks. Detailed installation instructions can be found on the next page.
The RJ45 cable must be connected from the heater, into the CHPWR, then into the CHES. The CHES WILL NOT OPERATE without connecting the power supply.
Microwave Occupancy Sensor
There are two knobs within the CHES that allow you to change the Sensitivity
and Response settings. When setting this it is advisable to use the walk test
feature.
This is enabled by switching DIP switch 1 to the On position. The blue LED
will now light up when movement is detected. When no movement is detected for
5 seconds, the LED will switch off.
Remote or Boost Switch
The CHES can be connected to any remote switch via the volt free external input. This can be configured as either a boost function or an Off control switch. The boost function simply boosts the temperature for a set duration. If using this feature a push button style switch must be used.
The Off control will deactivate the heating completely. A common use for this would be to enable a key switch to lock off the heating. The connection is volt free and is normally open. This can be seen in the picture above. This switch can be tested by switching the DIP switch 1 to the On position. An orange light on the RJ45 port will then illuminate when the switch is active and then go off once it is de-activated.
BMS error reporting
The CHES can provide error reporting to a BMS system.
When no error is detected, there will be 5V between GND and BMS ERR 5V ports. When an error in any of the connected heaters is detected, there will be 0V.
MCBMS
If only fault reporting for BMS or remote switching is required a MCBMS can be used.
The MCBMS offers 2 functions; BMS error reporting and an external remote or boost switch connection. When used as a switch, the MCBMS must be used in conjunction with a CHMC controller and CH heaters.
Detailed installation diagram for CHPWR
CH06CPIRX & CH09IRX
CH06CSIRX
CH12IRX
Typical Installation Diagram
Declaration Of Conformity
In accordance with UK Government Guidance.
WE HEREBY CERTIFY THAT THE APPLIANCES DETAILED HEREON HAVE BEEN INSPECTED AND TESTED, AND CONFORM TO THE REQUIREMENTS OF THE FOLLOWING UK STATUTORY INSTRUMENTS WHERE APPLICABLE: Electrical Equipment (Safety) Regulations 2016 SI. 2016 1101
Electromagnetic Compatibility Regulations 2016 SI. 2016 No. 1091
Radio Equipment Regulations 2017 SI. 2017 No. 1206
The Ecodesign for Energy Related Products and Energy Information
(Amendment) (EU Exit)
Regulations 2019. SI. 2010 2617
The Restriction of use of Certain Hazardous Substances. SI. 2012 No. 3032
Transposed standards used:
-
BSEN55014 (2006)
-
BSEN301 489.1 & .3
-
BSEN300 220.1 & .2
-
BSEN60 730.2.9
-
BSEN 60335.1 (2012 )
-
BS EN 60335.2.30 (2009)
PART NUMBER OF APPLIANCE CHES
NAME OF RESPONSIBLE PERSON: LEE GRIFFITHS
POSITION: PRODUCTION AND QUALITY MANAGER
DATE: 01/11/22
Customers Support
CONSORT EQUIPMENT PRODUCTS LTD.
THORNTON INDUSTRIAL ESTATE, MILFORD HAVEN, PEMBROKESHIRE, SA73 2RT. UK
TEL: +44 1646 692172 FAX: +44 1646 695195. E-MAIL:
ENQUIRIES@CONSORTEPL.COM
WWW.CONSORTEPL.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>