FORTINET 50G 5G Series Forti WiFi AVFire Walls User Guide
- June 13, 2024
- FORTINET
Table of Contents
FORTINET 50G 5G Series Forti WiFi AVFire Walls
The Essentials
Default Logins
- https://192.168.1.99 Username: admin Password: leave blank
- SSID: fortinet Password: fortinet
Fortinet Documents Library
For a detailed administration guide, up-to-date hardware manuals and reference
materials, visit https://docs.fortinet.com/
Support Resources
Register for FortiGuard updates, cloud management, firmware upgrades,
technical support and warranty coverage at https://support.fortinet.com
FortiExplorer App
Rapidly provision, deploy, and monitor Security Fabric components using a mobile device.
Download FortiExplorer for your OS: https://links.fortinet.com/fortiexplorer/downloads
Package Contents
FortiWiFi 50G-5G Series FWF-50G-5G, FWF-51G-5G
Setup
FortiExplorer App
Enable Bluetooth on your mobile device for BLE or connect a mobile USB
cable into the device.
GUI
Configure the management computer with dynamic IP https://192.168.1.99 or
static IP 192.168.1.x and subnet 255.255.255.0
CLI
FortiGate Cloud
Visit https://forticloud.com to leverage your FortiGate SD-WAN integrations
and unified cloud management services.
Dual 5G Nano SIM Slots
SIM1 is primary, SIM2 is secondary; SIM type is 4FF – Nano SIM. Refer to the Admin guide for wireless configuration at https://docs.fortinet.com
Antenna Installation
Attach the provided antennas to the SMA connections: 5G, GPS, and WiFi.
Front FWF-50G-5G Series
Rear FWF-50G-5G Series
- Antenna Connector (8x SMA)
- Power Input 12V DC, 100-240V AC 50/60Hz adapter
- USB 3.0 Server Port
- CONSOLE (RJ45) CLI management
- Signed Firmware Switch
- Ports (5x RJ45) WAN, A – FortiLink, 3, 2, 1
Cautions and Warnings
Environmental specifications
- Ambient operating temperature: 0°C to 40°C
- Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)
Safety
Battery – Risk of explosion if the battery is replaced by an incorrect
type. Do not dispose of batteries in a fire. They may explode. Dispose of used
batteries according to your local regulations.
IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.
This product is intended to be supplied by a Listed pluggable A via Class I external power supply adapter through a power cord connected to a socket outlet with an earthing connection.
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used by the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada
This Class B digital apparatus complies with Canadian ICES-003.
Innovation, Science and Economic Development (ISED) – Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
For products available in the USA/Canada market, only channels 1~11 can be operated. Selection of other channels is not possible. This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point- to-point operation as appropriate. The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit, and The worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement outlined in Section 6.2.2(3) shall be indicated.
- Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce the potential for harmful interference to co-channel mobile satellite systems.
- Caution: The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit, and the maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate.
This radio transmitter (IC: 7280B-3901M12) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
This device and its antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except by following IC multi-transmitter product procedures.
Antenna No.
|
Manufacturer
|
Model
|
Antenna Type
|
Connector
|
Antenna Peak Gain
---|---|---|---|---|---
1
|
Speed
|
F-0Q-FS-6156-001-00
|
Dipole
|
SMA
| 0.31 dBi for 2.4GHz(WLAN)
2.54 dBi for 5GHz
2
|
Speed
|
F-0Q-FS-6156-001-00
|
Dipole
|
SMA
| 0.31 dBi for 2.4GHz(WLAN)
2.54 dBi for 5GHz
3
|
Speed
|
F-0Q-FS-6156-001-00
|
Dipole
|
SMA
| 0.31 dBi for 2.4GHz(WLAN)
2.54 dBi for 5GHz
4
|
Joymax
|
IHF-2120MPX9-W018
|
monopole
|
iPex MHF1
|
1.53 dBi for 2.4GHz(BLE)
IMPORTANT: The device must be professionally installed and must use the supplied antenna.
Professional Installation Instruction
- Installation personnel This product is designed for specific applications and needs to be installed by qualified personnel who have RF and related rule knowledge. The general user shall not attempt to install or change the settings.
- Installation location The product shall be installed at a location where the radiating antenna can be kept 20cm from a nearby person in normal operation conditions to meet Regulatory RF exposure requirements. The installation applies to indoor locations.
- External antenna(s) Use only the antenna(s) that have been approved by the manufacturer. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power that may lead to the violation of FCC/ISED limit and is prohibited.
- Warning Please carefully select the installation position and ensure that the final output power does not exceed the limit outlined in relevant rules. The violation of the rule could lead to serious federal penalties.
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations
of software, firmware and hardware) provided by Fortinet or Fortinet’s
authorized partners to the end-customer directly for use within the EU or
countries that have implemented the EU Directives and/or spectrum regulation.
Any Fortinet products not obtained directly from Fortinet or Fortinet’s
authorized partners may not comply with EU Directives and Fortinet makes no
assurances for such products.
Note: The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/EU
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range in the following countries:
| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| FI| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK (NI)
Compliance with 2014/53/EU Radio Equipment Directive (RED)
Under Article 10.8(a) and 10.8(b) of the RED, the following table provides information on the frequency bands used and the maximum RF transmit power of the product for sale in the EU:
STANDARD | FREQUENCY RANGE | TRANSMIT POWER |
---|---|---|
Bluetooth | 2402-2480MHz | Less than 20dBm (EIRP) |
WLAN | 2412-2472MHz | Less than 20dBm (EIRP) |
5180-5240MHz | Less than 23dBm (EIRP) | |
5260-5320MHz | Less than 23dBm (EIRP) * | |
5500-5700MHz | Less than 30dBm (EIRP) * | |
5745-5825MHz | Less than 14dBm (EIRP) | |
WCDMA | Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 8: | |
880-915MHz(Uplink);925-960MHz(Downlink) | 24 dBm (Conducted) | |
LTE | Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 3: |
1710-1785MHz(Uplink); 1805-1880MHz(Downlink) Band 7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink) Band 8: 880-915MHz(Uplink);925-960MHz(Downlink) Band 20: 832-862MHz(Uplink); 791-821MHz(Downlink) Band 28: 703-748MHz(Uplink); 758-803MHz(Downlink) Band 34: 2010-2025MHz
Band 38: 2570-2620MHz
Band 40: 2300-2400MHz
Band 41: 2496-2690MHz
Band 42: 3400-3600MHz
Band 43: 3600-3800MHz
| 24 dBm (Conducted)
Band 41: 2496-2690MHz| 27 dBm (Conducted)
5G NR| n1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) n3:
1710-1785MHz(Uplink); 1805-1880MHz(Downlink) n7: 2500-2570MHz(Uplink);
2620-2690MHz(Downlink) n8: 880-915MHz(Uplink);925-960MHz(Downlink)
n20: 832-862MHz(Uplink); 791-821MHz(Downlink) n28: 703-748MHz(Uplink); 758-803MHz(Downlink) n38: 2570-2620MHz
n40: 2300-2400MHz n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz
| 24 dBm (Conducted)
n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz| 27 dBm (Conducted)
- Note: Only with DFS band certification
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to the power listed below:
STANDARD | FREQUENCY RANGE | TRANSMIT POWER |
---|---|---|
Bluetooth | 2402-2480MHz | Less than 20dBm (EIRP) |
WLAN | 2412-2472MHz | Less than 20dBm (EIRP) |
5180-5240MHz | Less than 23dBm (EIRP) | |
5260-5320MHz | Less than 23dBm (EIRP) * | |
5500-5700MHz | Less than 30dBm (EIRP) * | |
5745-5825MHz | Less than 14dBm (EIRP) | |
WCDMA | Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 8: | |
880-915MHz(Uplink);925-960MHz(Downlink) | 24 dBm (Conducted) | |
LTE | Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) Band 3: |
1710-1785MHz(Uplink); 1805-1880MHz(Downlink) Band 7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink) Band 8: 880-915MHz(Uplink);925-960MHz(Downlink) Band 20: 832-862MHz(Uplink); 791-821MHz(Downlink) Band 28: 703-748MHz(Uplink); 758-803MHz(Downlink) Band 34: 2010-2025MHz
Band 38: 2570-2620MHz
Band 40: 2300-2400MHz
Band 41: 2496-2690MHz
Band 42: 3400-3600MHz
Band 43: 3600-3800MHz
| 24 dBm (Conducted)
Band 41: 2496-2690MHz| 27 dBm (Conducted)
5G NR| n1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink) n3:
1710-1785MHz(Uplink); 1805-1880MHz(Downlink) n7: 2500-2570MHz(Uplink);
2620-2690MHz(Downlink) n8: 880-915MHz(Uplink);925-960MHz(Downlink)
n20: 832-862MHz(Uplink); 791-821MHz(Downlink) n28: 703-748MHz(Uplink); 758-803MHz(Downlink) n38: 2570-2620MHz
n40: 2300-2400MHz n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz
| 24 dBm (Conducted)
n41: 2496-2690MHz n77: 3300-4200MHz n78: 3300-3800MHz| 27 dBm (Conducted)
Note: * Only with DFS bands certification
- This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.
- This product complies with Statutory Instrument 1206 Radio Equipment Regulations 2017
- The full Declaration of Conformity for this product is available in the link below:
- https://site.fortinet.com/ProductRegulatory/UK
- The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range in the following countries:
- UK (NI)
December 14, 2023 Copyright© 2023 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s General Counsel, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward-looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable. For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf