Important safety information and warnings

  • This manual contains important safety information about instalation and operation of the alarm. Carefully read the manual and store it in a safe place for future reference.

Operation requirements

Warning

  • Do not ignore the detector alarm under any circumstances, doing so could result in serious injury or death.
  • Exposing the detector to high or low temperatures or high humidity can significantly reduce battery life

Caution

  • Before using the device, make sure the detector is properly installed in the mounting bracket and its power supply has been activated.
  • Use the device in accordance with the instructions given for the operating environment.
  • Transport, use and store the equipment under the humidity and temperature conditions permitted by the manufacturer.
  • Do not expose the product to water or moisture, dripping or splashing water
  • Do not insert any objects into the ventilation holes of the product, do not cover the product and prevent water or other liquids from entering the detector.
  • This fire detector is designed to indicate the presence of smoke only, it is not designed to detect carbon monoxide (CO), combustible gases or other hazards.

Installation requirements
Warning

  • Improper installation and operation of this device will prevent its proper operation and consequently its response to fire hazards.

Caution

  • When working at heights, follow all safety procedures and use the required protective equipment designed for this purpose.
  • Do not expose the product to direct sunlight, extreme cold and humidity or sudden temperature changes.
  • Before using the device, you must affix the information label (see Picture 4-3) „WARNING! – The battery is not replaceable see the user‘s manual“ in your language.
  • If you are carrying out construction work where dust is generated, you should remove the device from the mounting bracket to prevent dust particles from contaminating it or contaminating the detection chamber. If for some reason this is not possible, you should cover the detector (e.g. with a plastic bag) while the work is being carried out to prevent dust contamination. A covered fire detector cannot detect smoke, so uncover it every day after the work is finished.
  • Installation and handling of this device must always comply with local electrical safety requirements, requirements for protection against electric shock, and other relevant regulations.

Introducing the device

2.1 Information about the device

  • The smoke detector (hereinafter also referred to as „the device”) is designed for continuous monitoring, detection and signalling of smoke. The Device utilizes advanced split-spectrum photoelectric chamber technology, a built-in loud alarm buzzer, fast response to hazard detection combined with high sensitivity, stable performance and high false alarm immunity. When the smoke concentration in the vicinity of the sensor reaches an alarm level, the detector immediately triggers an audible and visual alarm signal to inform the user of the impending danger so that he can take adequate action.

2.2 Description of the device

SAFE 10Y30 BASIC Smoke Alarm - Description

No. Name Description
1 LED indicator •  Visually indicates the status of individual device modes
2 Buzzer •  Alarm volume: 85 dB (A) at 3m
3 Test/Mute button TEST •  Verifies device functionality

•  Temporary silencing of the audible alarm
4| Battery compartment| •  Built-in battery, not user repla- ceable

Technical information

Specification Description
Sensor type Photoelectric – dual spectral
Ordering code 10Y30 – BASIC
Power source 3V CR123A lithium battery (non-replecable)
Battery life 10 years
Alarm signalization Visual– double LED indicator

Audible – 85dB at the distance of 3 m
Pre-set alarm value| 0.2 dB/m-0.3 dB/m
Operating current| Monitoring mode: ≤15uA During alarm: ≤35mA
Operating temperature| -10°C to +55°C (+14°F to 131°F)
Operating humidity| 95% RH (non condensing )
Detection area| When the height of the space is less than 8 m, the protected area of the device is 20 m2 – 40 m2
Dimensions| Φ 81.5 mm × v 51.6 mm ( Φ 3.21“ × h 2.03“)
Weight (with battery)| 110 g (0.24 lb)
Certification| EN 14604:2005+AC: 2008
Type| DHI-HY-SA40A

Device installation

Check the contents of the package according to the following checklist. If you find any damage to the device or incomplete contents, contact your seller.
4.1 Package content
Checklist 4-1 Package content

Name|

Amount

---|---
Smoke alarm| 1
Self-tapping screw| 2
Dowel pins| 2
Mounting bracket| 1
User manual with set of information labels| 1

4.2 Installation position
Caution

  • Installation must be carried out by a competent person. The person carrying out the installation is responsible for installing the devices in accordance with the applicable regulations. If in doubt, consult qualified professionals or contact our technical support for installation. This device is intended for use in normal indoor areas of residential units. The design and layout of individual rooms will vary, so consider this location as a guide only. Smoke alarms should ideally be installed in all rooms of the house except kitchens, bathrooms and garages. There should be at least one smoke alarm on each floor of the house, including stairwells. Smoke alarms should be placed in places where you can hear it even when you are asleep, such as in the hallway outside the bedroom, etc. Install smoke alarms on the ceiling of each bedroom and in the hallway outside the bedroom.

  • If the hallway is longer than 9 m, install a detector at both ends.

  • If you have a two-storey house, install smoke detectors in the same way on each floor, so you are also protected from smoke rising up the stairwell from the lower floor. In the basement, install a fire detector on the ceiling at the bottom of the staircase.

  • Do not install smoke alarms in bathrooms or kitchens, as water and food steam can initiate a false alarm.

  • In the garage, the detector could react to exhaust fumes from your car.

  • Ventilation openings of the detector can not be covered or sealed.

  • Avoid using aerosol products near this device.

  • National regulations vary in relation to the number and location of smoke detectors.

  • If in doubt, contact, for example, the fire brigade.
    Picture 4-2-1
    Recommended placement of smoke detectorsSAFE 10Y30 BASIC Smoke Alarm -
Description 1

  • Ceiling or wall installation
    The manufacturer allows for both ceiling and side wall installation, with the preferred mounting location being a central ceiling installation. If the device is installed on the ceiling, install it at a minimum distance of 500 mm from the corners of the room. When mounting on a side wall, position the unit so that the top of the unit is a minimum of 100 mm and a maximum of 305 mm below the ceiling level See Picture 4-2-2.SAFE 10Y30 BASIC Smoke Alarm -
Picture

  • Installation on sloped ceiling
    If the inclination is less than 45°, the appropriate distance is at least 500 mm. When the inclination is greater than 45°, a wooden base (not included) must be installed, see Picture 4-2-3.SAFE 10Y30 BASIC Smoke Alarm - Picture
1

4.3 Installation steps
Follow the steps below for proper installation of the device Step 1 Select a suitable location for the installation of the smoke detector.
Step 2 Drill holes in the installation location using the mounting bracket (⌀ 6mm). Insert the dowels into the prepared holes.
Step 3 Attach the bracket using the self-tapping screws.

SAFE 10Y30 BASIC Smoke Alarm - Picture 2

Step 4 Installation of the device
Affix the information label (see Picture 4-3-1) „WARNING! – Battery is not replaceable see user manual” in your language to the device. Insert the detector into the mounting bracket and rotate it clockwise until it reaches the locking position (see Picture 4-3-1). If it is necessary to remove the detector from the mounting bracket rotate the device counterclockwise.
Caution
After the detector is fixed in the mounting bracket it automatically activates. This status is indicated by a short beep of the buzzer and a green flash of the LED indicator. The device then initializes for a few seconds and automatically enters monitoring/operational mode. Monitoring mode signalization

  • Green LED indicator flashes 1x every 60 seconds

Testing and Maintanance

5.1 Testing

  • After installation or during regular maintenance, the detector must be tested to prove its functionality. If you encounter a problem while testing the device, read the information in the „Frequently Asked Questions” and  Maintenance” sections for solutions to some situations and then retest the detector. If the testing is not completed successfully, send the device in for a claim.
    Device self-test

  • Press the button briefly ,TEST/ the buzzer tone sounds and the LED indicator flashes red, followed by a pause, followed by the buzzer beeping 3 times in succession accompanied by the flashing of the red LED indicator, pause again, and  then it repeats once more.
    Temporary alarm mute

  • When the smoke concentration reaches a predetermined value, the device will indicate the alarm visually by flashing the red LED indicator accompanied by a loud buzzer alarm (85 dB): 1x per second 1x flashing of the red LED indicator and simultaneously 1x beep of the buzzer.

  • In the event of a false alarm, the acoustic signalling can be tem- porarily muted by pressing the button TEST/ . The temporary mute mode is signalled by the device by flashing the red LED indicator once per second. If the concentration of cortical particles subsequently falls below predetermined values, the detector automatically switches to normal operating mode.
    Malfunction
    If a malfunction is diagnosed by the device, this condition will be indicated by the detector as follows:

  • The red LED indicator flashes twice every 60 seconds. In this state the device is not functional. Check the detector for damage, clean the ventilation holes of the detector e.g. with a vacuum cleaner. Test the device by pressing the button TEST/ and follow the information in the chapters „Frequently asked questions“ and „Maintenance“.

  • If this information has not helped you, please contact our technical support.

Caution

  • This fire detector in alarm mode can also be temporarily silenced via the infrared remote control (most remote controls for household appliances such as TVs). Pressing any button on the remote control activates the temporary silencing function, in which the device remains in for 9 minutes. At the end of this time interval, the detector will switch back to the alarm mode or, if the smoke particles have dropped, to the normal operating mode.
    Low battery voltage, end-of-life indication

  • If the capacity and voltage of the power supply battery drops below a certain threshold or the end of the life of the device is approaching, the detector will signal this condition by flashing the red LED indicator once accompanied by a buzzer beeping once at regular 60 second intervals for 30 days before the battery is completely discharged.

  • WARNING – The battery in this unit is built-in and not replaceable. If the detector battery is empty, replace it with a new one.

5.2 Care and maintenance
To keep your device in good working order, follow these instructions and recommendations.

  • Perform a simulated fire alarm test at least once a week by pressing the button TEST/ , to verify proper operation of the device. If a problem is detected, follow the information in the „Frequently Asked Questions“ and „Maintenance“ sections. If this information has not helped you, contact our technical support.

  • The detector should be cleaned at least once a month. If the de- tector needs to be cleaned, remove it from the mounting bracket by turning it counterclockwise. Remove any accumulated dust particles in the of the detector with a vacuum cleaner. The outside of the detector can then be wiped with a wet cloth. After cleaning, reinstall the detector back into the mounting bracket and test the device by using the test button TEST/ . Avoid cleaning the detector with cleaning solutions or solvents to prevent possible contamination of the sensor and loss of the warranty.

  • Do not paint the device. Paint can seal the air circulation holes and interfere with the sensor‘s ability to detect smoke.

  • Do not place the device in areas prone to vibrations and shocks – they can cause damage to the device.

  • Do not expose the detector to excessive pressure, shock, dust, high temperature or humidity – these may cause the device to malfunction, shorten its life or damage the battery or deform plastic parts.

  • Do not place any sources of open flame, such as a lit lighter, candle, etc., on or near the device.

  • Do not install the detector in places where there is insufficient airflow, near fans or other air handling equipment

  • Do not disassemble the detector or tamper with the internal electrical circuits of the device. Any such attempt will result in loss of the warranty. The product can only be serviced or repaired by a manufacturer‘s authorized service center.

  • If the detector is damaged or if there is any malfunction, do not carry out any repairs yourself. Contact your dealer or our service support.

  • This device is not intended for use by persons (including children) whose physical, sensory or mental incapacity or lack of experience or knowledge prevents them from using the equipment safely, unless they are supervised or have
    been instructed in the use of this equipment by a person responsible for their safety. Children must be supervised to ensure that they do not play with the device.

  • The detector will need to be replaced after 10 years from the date of installation, see the date of installation label on the back of the detector.

Frequently asked questions – FAQ

Problem Solution
Your fire alarm does not sound the buzzer during testing • If you are testing

the device immediately after it is first activated, you should wait a few seconds for the detector to initialize.
• Make sure you press the button correctly TEST/
The smoke alarm chirps intermittently| • Check the correct positioning of the device (see chapter: „Device installation”)
• Clean the smoke detector (see chapter: „Care and maintenance”)
The LED indicator flashes red and a single beep of the buzzer sounds every 60 seconds| • The detector battery is depleted, replace the device with a new one immediately.

Safety habits

7.1 Planning and practicing evacuation

  • Place fire extinguishers on every floor of the house, in the kitchen, basement and garage and keep them in working, serviceable condition. Learn to operate fire extinguishers before an emergency occurs.
  • Make an evacuation diagram of the building including each floor with all doors and windows and mark at least two main escape routes. When planning the use of windows on the second floor, you may need to consider the use of a rope or evacuation ladder.
  • Familiarise everyone with the fire evacuation plan (everyone should know what to do in the event of a fire).
  • Outside the building, designate an evacuation point where you will all meet in the event of a fire.
  • Familiarize everyone with the fire alarm signal and instruct them to evacuate the building immediately upon discovering the alarm.
  • Conduct fire drills with evacuation training at least once every six months, including during night hours. Ensure that even young children can hear the fire alarm signal and can be woken up when it sounds. Waking up all individuals early presents an opportunity for early evacuation along the escape route. These drills will allow everyone to test the evacuation plan before an actual emergency. It is possible that you may not be able to reach your children in the event of a fire, so it is important that they too know what to do in such a situation.

7.2 What to do in case of an alarm

  • Wake up the small children.
  • Immediately leave the threatened area along your proposed escape route. Time is precious, so don‘t waste it dressing or collecting valuables. During an evacuation, never open an interior door without first touching it. If the door is hot or smoke is coming in through the joints, do not open it under any circumstances! Instead, use an alternative escape route. If the door is not hot, brace yourself against it with your shoulder and open it carefully, but still be prepared to close the door immediately if heat or heavy smoke should penetrate to you.
  • If you are in an area with a concentration of smoke, move close to the ground. Breathe slowly and ideally through wetted textiles.
  • Once you get out of the building, go to your designated evacuation point and make sure everyone is present.
  • Always contact the relevant units of the integrated rescue system when you are safe!
  • Do not return to the building until the danger has passed.

Disposal

Do not dispose of electrical appliances as unsorted municipal waste, use sorted waste collection points.
Contact your local authority for up-to-date information on collection points. If electrical appliances are dumped in landfill sites, hazardous substances can seep into groundwater and enter the food chain, harming your health.
Warning
Do not burn or throw into fire.

Seven-year warranty

  • The manufacturer warrants that the enclosed fire detector will be free from defects in material and workmanship under normal use and service for a period of seven years from the date of sale. The manufacturer‘s obligation under this warranty is limited to repairing, replacing the detector or any of its parts found to be defective in material or workmanship, free of charge, after sending the detector together with proof of the date of purchase and postage paid to the service centre at SAFE HOME europe s.r.o., Čechova 1005/4, 750 02 Přerov, Czech Republic.
  • This warranty is invalidated if the product has been damaged, altered, misused, modified, or if it stops working due to poor maintenance or improper placement after purchase.
  • Any implied warranties arising out of this sale, including, but not limited to, implied warranties of description, merchantability and fitness for a particular purpose are limited to the duration of this warranty.
  • Under no circumstances shall the manufacturer or any of its parent companies, subsidiaries, or our agents or distributors be liable for any loss of functionality of this product or for any indirect, special, incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product, whether due to breach of contract, negligence, strict liability in tort or otherwise.
  • The manufacturer or any of its parent companies, subsidiaries or our agents or distributors shall not be liable for any personal injury, property damage or other special, incidental, consequential or incidental damages resulting from a gas leak, fire or explosion.
  • This guarantee does not affect your legal rights.

Documents

  • A declaration of conformity and a declaration of performance have been issued for the product.

  • Individual declarations as well as the user manual and other product documents can be found on the website: http://www.safe-home.eu

  • Service centre:
    SAFE HOME europe s r.o.
    Čechova 1005/4
    750 02 Přerov
    Czech Republic

  • Factory:
    Zhejiang Huaxiao Technology Co.,Ltd.
    1-3/F, Building A2 ,No. 28 Dongqiao Road, Dongzhou Street,
    Fuyang District, Hangzhou, Zhejiang, China

SAFE 10Y30 BASIC Smoke Alarm - Icon 1

SAFE 10Y30 BASIC Smoke Alarm - Qr Codehttps://www .safe-home.eu/

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SAFE User Manuals

Related Manuals