Miele PT 8303 SL Vented Dryer Installation Guide
- June 11, 2024
- Miele
Table of Contents
PT 8303 SL Vented Dryer
Installation Guide Installation
Plan
Tumble dryer
PT 8303 SL EL (Electrically Heated)
PT 8303 SL Vented Dryer
|
---|---
|
|
|
Technical datasheet
Tumble dryer: PT 8303 SL
Heating: Electric (EL)
Legend:
Abbreviations in bold type: Connection required
Abbreviations in circle with dashes: Connection optional or required depending
on model version
Machine connections:
EL| Electrical connection| Standard voltage
Frequency
Rated load
Fuse rating
Supply lead cross-section| 3 AC 220 – 240 V
60 Hz
15.4 kW
3 x 40 A
4 x 6 mm²| 4 × 10 AWG
---|---|---|---|---
Convertible to
Frequency
Rated load
Fuse rating
Supply lead cross-section| 3 AC 208 V
60 Hz
11.7 kW
3 x 35 A
4 x 6 mm²| 4 x 10 AWG
Convertible to
Frequency
Rated load
Fuse rating
Supply lead cross-section| 2 AC 208 V
60 Hz
8.1 kW
2 x 40 A
3 x 6 mm²| 3 x 10 AWG
Electrical connection must comply with national regulations. A wall socket or
main isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment or checks on the
protective conductor, including determination of correct fuse rating, should
only be performed by a trained electrician.| |
AL| Vented| Nominal air throughput in vented mode Max. permissible
pressure loss
Waste air/gas temperature, max. Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
As relative humidity inside the vent ducting can be as high as 100%, suitable
measures must be taken to prevent a back- flow of condensate into the
machine.| 821 m³/h
300 Pa
80 °C
150 mm
150 mm| 28993 cfh
0.0435 psi
176 °F
5 15/16“
5 15/16“
ZL| Air intake| Standard Connection:
~ð Air intake from installation site Min. air intake cross-section (to
prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace the air
extracted.|
531 cm²
|
82.305 in²
Alternative connection: Ducted air intake (from outside build-ing)
Connector on machine (int. diameter) Connection pipe provided on site (int.
diameter)
Lid removal exposes live components! For safety reasons, the pipe connected
for central air intake should be at least 900 mm long and secured using two
screws.| 161 mm
160 mm
| 6 5/16”
6 5/16”
B| Fittings
(supplied)| Without base
2 x clamps
4 × screws DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided on site.| 6 mm
x 40 mm
10 mm x 50 mm| 1/4” x 1 9/16”
3/8” x 2”
---|---|---|---|---
| Machine data| Width
Depth
Height
Casing width
Casing depth
Minimum width of delivery access to installation site
Minimum rear wall gap (measured to front of machine)
Wall gap (to front of machine)
Minimum gap ensures sufficient space for maintenance and servicing.
Net weight
Dynamic floor load, max.
Average heat dissipation
(dependent on ambient room temperature and programme selected)
Noise level
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)| 711 mm
1088 mm
1800 mm
708 mm
999 mm
725 mm
1500 mm
500 mm
139 kg
1584 N
473 W
68.9dB (A)
56 dB (A)| 28“
42 7/8“
70 7/8“
27 7/8“
39 5/16“
28 9/16“
59 1/16“
19 11/16“
306.4 lbs
1615 BTU/h
Installation should only be carried out by authorized installers in accordance
with national regulations! Follow installation instructions when installing
machine!
Please have the model and serial number of your machine available when contacting Technical Service.
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
www.mieleusa.com/professional
prosales@mieleusa.com
Technical Service & Support
Phone: 800-991-9380
proservice@mieleusa.com
Canada
Importer
Miele Limited
Professional Division
161 Four Valley Drive
Vaughan, ON L4K 4V8
Phone: 1-888-325-3957
www.mieleprofessional.ca
professional@miele.ca
Miele Professional
Technical Service
Phone: 1-888-325-3957
serviceprofessional@miele.ca
Manufacturer: Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gutersloh, Germany
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.