PCE INSTRUMENTS PCE-RAM 5 Radiation Detector User Manual
- June 10, 2024
- PCE Instruments
Table of Contents
PCE INSTRUMENTS PCE-RAM 5 Radiation Detector
Product Information
First Product Profile
Model PCE-RD M 5 product is one small size high sensitivity radiation dose
alarm instrument, mainly used to monitor X, β, and γ rays. It configured white
light OLED screen, visual in night. It has both sound and flashing alarm
method, and the alarm threshold able to be key setting. The main of this
instrument is compliance with national and international standard line.
Second Main characteristics
- Smaller measure error range and able pass through national metering standards.
- Dose rate alarm threshold and metering alarm threshold all can be key setting.
- It has overdose alarm function, sound and optical alarm.
- Start machine and test automatically, simply and easily operation.
- It has exquisite volume and light weight, pen clamps design convenient to wear.
- Internal configured chargeable lithium battery, able to continue test 50 hours after fully charged.
- Display screen able to continuously measure after automatic dormancy.
- White light OLED display screen design, displayed more clearly, also able to normally display in night.
- It has sensor fault reminding function (the display screen display “Device Fault”).
Third Technical Parameters
- Sensor: 48mm Geiger counter tube
- Measure range: 0.05uSv-50mSv
- Measure precision: -17%…+25% based on 137Cs γ
- Working environment: temperature -20°C…50°C; humidity <85% RH without dew
- Size: diameter 15.3mm, length 108mm, weight: 19g
- Durable time: 50h or (continue measure, screen dormant)
- Charging time: 2-3 hours
- Charging joggle: TYPE-C joggle (green light normally lighting when charging, extincted when fully charged)
- Alarm responding time td: <10s
Fourth Menu Instruction
DOSE RATE:
means moment dose rate
00:00: 05
means start measure time, the max 100 hours
DOSE:
means accumulated dose
AVR:
means the average dose rate
MAX:
means the max dose rate
DOSE RATE Alarm:
set the alarm threshold of moment dose rate
DOSE Alarm:
set the accumulate dose alarm threshold
Fifth Keys Instruction
- Power supply key (at right side): 3s long time press for power on/off, short time press for function keys
- Menu key (at the left side): used in menu page turning and alarm threshold adjustment
Sixth Alarm Setting
Power on and default the lock status, indicate the “?” on the display screen, need press the power supply key for unlock at the same time of press the menu key, only can set the alarm parameters after unlocked.
- Set the moment dose rate alarm threshold (DOSE RATE Alarm):
- Short time press menu key shift the menu to DOSE RATE Alarm page.
- Short time press power supply key DOSE RATE Alarm then alarm value flashing, now circling shift to alarm value within 0.6-300uSv range through menu key.
- Short time press power supply key to save the alarm value.
- Set the accumulate dose alarm threshold (DOSE Alarm):
- Short time press menu key shift the menu to DOSE Alarm page.
- Short time press power supply key DOSE Alarm then alarm value flashing, now circling shift to alarm value within 1-3000uSv range through menu key.
- Short time press power supply key to save the alarm value.
Seventh Safety Notices
Instrument unexpected fallen| Please confirm whether radiation dose indicate
value are normal, whether it will update. Please don’t apply the instrument in
the high strength radiation field.
---|---
Instrument reminding “Equipment damaged”| Please don’t apply the instrument in
high strength radiation field.
Contain explode and inflammable gas or powder dust in the operate environment|
Please don’t apply the instrument in explode and inflammable gas and powder
dust environment.
Waterproof| Please attention the waterproof degree of instrument only IP40,
can’t be raining or water splashing. For the X-ray, it only can used as
reference of test strong or weak radiation, unable to meet energy responding
requirements.
Specifications
- Model: PCE-RAM 5
- Type: X, Y radiation personal dosc equivalent Hp (10) monitor instrument
Sensor Type | 48mm Geiger counter tube |
---|---|
Measure Range | 0.05uSv-50mSv |
Measure Precision | -17%…+25% based on 137Cs γ |
Battery Life | 50 hours on a full charge, with continuous measurement |
capability
Charging Port| TYPE-C joggle
Product Usage Instructions
Safety Precautions:
Before using the PCE-RAM 5, ensure you read and understand all safety
precautions mentioned in the user manual.
Powering On:
Press the power button to turn on the instrument. Wait for the device to
initialize.
Calibration:
It is recommended to calibrate the instrument before initial use or
periodically as per the calibration guidelines provided in the manual.
Taking Measurements
To measure X, Y radiation doses, place the instrument in the desired location and press the measurement button. Ensure the device is properly positioned for accurate readings.
Data Analysis:
Once measurements are taken, you can analyze the data displayed on the
screen or transfer it to a computer for further analysis using the provided
software.
FAQ
How often should I calibrate the PCE-RAM 5?
It is recommended to calibrate the instrument annually or as per specific
regulatory requirements.
What is the purpose of the PCE-RAM 5?
The PCE-RAM 5 is a high sensitivity radiation dose alarm instrument used to
monitor X, β, and γ rays.
How can the alarm thresholds be set on the PCE-RAM 5?
The alarm thresholds for the dose rate and accumulated dose can be set using
the keys after unlocking the device.
Is the PCE-RAM 5 waterproof?
The device is waterproof with a degree of IP40, which means it cannot be
exposed to rain or water splashing.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>