Electric Dryer W10514172A/W10514174A-SP Installation Manual

June 8, 2024
Whirlpool

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

Electric Dryer W10514172A/W10514174A-SP Installation
ManualThis is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

Electric Dryer W10514172A/W10514174A-SP Installation
Manual A DANGER You can be killed or seriously injured if you don’t immediate! follow instructions.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual A DANGER You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

Electric Dryer W10514172A/W10514174A-SP Installation
ManualWARNING – “Risk of Fire”

– Clothes dryer installation must be performed by a qualified installer. – Install the clothes dryer according to the manufacturer’s instructions and local codes. – Do not install a clothes dryer with flexible plastic venting materials or flexible metal (foil type) duct. If flexible metal duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire. – To reduce the risk of severe injury or death, follow all installation instructions.
– Save these instructions.

State of California Proposition 65 Warnings: WARNING: This product contains one or more chemicals known to the State of California to cause cancer. WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following:

  • Read all instructions before using the dryer.
  • Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
  • Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
  • Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
  • Before the dryer is removed from service or discarded, remove the door to the drying compartment.
  • Do not reach into the dryer if the drum is moving.
  • Do not install or store the dryer where it will be exposed to the weather.
  • Do not tamper with controls.
  • Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
  • Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
  • Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
  • Clean lint screen before or after each load.
  • Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
  • The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
  • See “Electrical Requirements” located in the installation instructions for grounding instructions.
    SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE INSTRUCTIONS

INSTALLATION REQUIREMENTS

Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed:

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Flat-blade screwdriver

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

#2 Phillips screwdriverWire stripper
(direct wire installations)

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Wire stripper
(direct wire installations)

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Tin snips
(new vent installations)

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

1/4″ nut driver (recommended)

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Vent clamps

Adjustable wrench that opens to 1″ (25 mm) or hex-head socket wrench

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Utility knifeElectric Dryer W10514172A/W10514174A-SP Installation
Manual

Tape measure

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Pliers

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Level

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Caulking gun and compound (for installing new exhaust vent)

Parts supplied (all models):

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Leveling legs (4)

Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting, and read “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the “Assistance or Service” section of the “Use and Care Guide”.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

  • A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be
    at least 4 ft. (1.22 m) long. The wires that connect to the
    dryer must end in ring terminals or spade terminals with upturned ends.

  • A UL listed strain relief.

Location Requirements

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

You will need:

  • A location allowing for proper exhaust installation.
    See “Venting Requirements.”

  • A separate 30 amp circuit.

  • If you are using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer.
    See “Electrical Requirements.”

  • A sturdy floor to support the total weight (dryer and load) of 200 lbs. (90.7 kg). The combined weight of a companion appliance should also be considered.

  • Level floor with maximum slope of 1″ (25 mm) under entire dryer. (If slope is greater than 1″ [25 mm], install Extended
    Dryer Feet Kit, Part Number 279810.) If not level, clothes
    may not tumble properly and automatic sensor cycles may
    not operate correctly.
    Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
    The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
    Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
    Installation clearances:
    The location must be large enough to allow the dryer door to open fully.
    Dryer Dimensions

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

A. Wide opening side-swing door
B. Wide opening hamper door
*Most installations require a minimum 5½” (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”

Minimum spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.

  • Additional spacing should be considered for ease of installation and servicing.

  • Additional clearances might be required for wall, door, and floor moldings.

  • Additional spacing of 1″ (25 mm) on all sides of the dryer
    is recommended to reduce noise transfer.

  • For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required.
    Louvered doors with equivalent ventilation openings
    are acceptable.

  • Companion appliance spacing should also be considered.

Minimum Required Spacing

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Additional spacing recommended

Mobile home – Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).

  • Metal exhaust system hardware, which is available for purchase from your dealer.
  • Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such
    as a nearby window) should be at least twice as large
    as the dryer exhaust opening.

Electrical Requirements

It is your responsibility:

  • To contact a qualified electrical installer.

  • To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.
    The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
    A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

  • To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

  • Do not use an extension cord.

  • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
    Electrical Connection
    To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

  • If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.

  • This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground connector screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

  • A 4-wire power supply connection must be used when the dryer is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
    If using a power supply cord:
    Use a UL listed power supply cord kit marked for use with
    clothes dryers. The kit should contain:

  • A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be
    at least 4 ft. (1.22 m) long. The wires that connect to the
    dryer must end in ring terminals or spade terminals with upturned ends.

  • A UL listed strain relief.

If your outlet looks like this:

Electric Dryer W10514172A/W10514174A-SP Installation
Manual Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least
4 ft. (1.22 m) long, must have 4 10-gauge solid copper wires and match a 4-wire 4-wire receptacle
(14-30R)      receptacle of NEMA Type 14-30 R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

Electric Dryer W10514172A/W10514174A-SP Installation
Manual Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least
4 ft. (1.22 m) long, must have 3 10-gauge solid copper wires and match a 3-wire 3-wire receptacle     receptacle of NEMA Type 10-30R.
(10-30R)

If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:

  • Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.
  • 10-gauge solid copper wire (do not use aluminum).
  • At least 5 ft. (1.52 m) long.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer. WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Install Leveling Legs

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Examine leveling legs, find diamond marking. Screw legs into
leg holes by hand, use a wrench to finish turning legs until
diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its final location. Leave enough room for electrical
connection and to connect the exhaust vent.

Electrical Connection

Power Supply Cord

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Electrical Connection Options

1. Choose electrical connection type

Electric Dryer W10514172A/W10514174A-SP Installation
ManualPower supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to steps 1-2 on
page 9 for power supply cord strain relief:
then steps 3-6 for 4-wire Power Supply
Cord Connection section. Then, go to
Venting Requirements.

Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Go to steps 1-2 on
page 9 for power supply cord strain relief:
then steps 3-5 for 3-wire Power Supply
Cord Connection section.
Then go to Venting Requirements.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual4-wire direct connection: Go to steps
1-2 on page 10 for direct wire strain relief:
then steps 3-8 for 4-wire Direct Wire
Connection section. Then go to Venting
Requirements.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual3-wire direct connection: Go to steps
1-2 on page 11 for direct wire strain relief:
then steps 3-7 for 3-wire Direct Wire
Connection section. Then go to Venting
Requirements.

NOTE: If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-wire Connection” section. This connection may be
used with either a power supply cord or a direct wire
connection.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Before you start, disconnect power. Remove hold-down screw
(D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
F. Hole below terminal block cover

Power Supply Cord Connection

Power supply cord strain relief

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove the screws from a 3/4″ (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole (B) below the terminal block opening
so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
For 3-wire Power Supply Cord Connection, see page 9.
For 4 wire Power Supply Cord Connection, continue to
step 3.

4-wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. 3/4″ (19 mm) UL listed strain relief
G. Ring terminals

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to Venting Requirements.

3-wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
E. 3/4″ (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove center terminal block screw (B).

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect neutral wire (white or center) (C) of power supply cord
to center terminal block screw (B). Tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into
slot of dryer rear panel. Secure cover with hold-down screw.
Now, go to Venting Requirements.

Direct Wire Connection

Direct wire strain relief

Unscrew the removable conduit connector (A) and any screws
from a 3/4″ (19 mm) UL listed strain relief (UL marking on strain
relief). Put the threaded section of the strain relief through the
hole (B) below the terminal block opening. Reaching inside the
terminal block opening, screw the removable conduit connector
onto the strain relief threads (C).

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Put direct wire cable through the strain relief. The strain relief
should have a tight fit with the dryer cabinet and be in a
horizontal position. Tighten strain relief screws.
For 3-wire Direct Wire Connection, see page 11.
For 4 wire Direct Wire Connection, continue to step 3 below.

4-wire Direct Wire Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit 3-wire connections.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer
may be moved if needed.
Strip 5″ (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5″ (127 mm). Cut 11/2″ (38 mm) from
remaining 3 wires. Strip insulation back 1″ (25 mm). Shape ends
of wires into hooks.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

To connect wires to terminal block, place hooked end of wire
under terminal block screw, facing to the right, squeeze hooked
end together and tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).

Connect neutral ground wire (E) and place hooked end (hook
facing right) of neutral wire (white or center wire) (C) of direct
wire cable under center screw of terminal block (B). Squeeze
hooked ends together and tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with holddown
screw. Now, go to Venting Requirements.

3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 31/2″ (89 mm) of outer covering from end of cable. Strip
insulation back 1″ (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

To connect wires to terminal block, place hooked end of wire
under terminal block screw, facing to the right, squeeze hooked
end together and tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove center terminal block screw (B).

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Place hooked end of neutral wire (white or center) (C) of direct
wire cable under center terminal block screw (B). Squeeze
hooked end together. Tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with holddown
screw. Now, go to Venting Requirements.

Optional 3-wire Connection
You must verify with a qualified electrician that this
grounding method is acceptable before connecting.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).

Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to Venting
Requirements.

VENTING

Venting Requirements

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

4″ (102 mm) heavy metal exhaust vent

  • Only a 4″ (102 mm) heavy metal exhaust vent and clamps may be used.

  • Do not use plastic or metal foil vent.
    Rigid metal vent:

  • Recommended for best drying performance and to avoid crushing and kinking.
    Flexible metal vent: (Acceptable only if accessible to clean)

  • Must be fully extended and supported in final dryer location.

  • Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

  • Do not install in enclosed walls, ceilings, or floors.

  • The total length should not exceed 73/4 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review “Vent System Chart” and, if necessary, modify existing vent system to achieve best drying performance.

Exhaust hoods:

  • Must be at least 12″ (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

Recommended Styles:

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Elbows:

  • 45° elbows provide better airflow than 90° elbows.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Clamps:

  • Use clamps to seal all joints.
  • Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct
    and catch lint. Do not use duct tape.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

See “Venting Kits” for more information.

Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

A. Dryer                           E. Clamps
B. Elbow                          F. Rigid metal or flexible metal vent
C. Wall                             G. Vent length necessary to connect elbows
D. Exhaust hood             H. Exhaust outlet

Electric Dryer W10514172A/W10514174A-SP Installation
ManualElectric Dryer W10514172A
/W10514174A-SP Installation Manual Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.
Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Over-The-Top installation (also available with one offset elbow)

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase.

Venting Kits
For more information, call 1-800-901-2042, or visit us at
www.applianceaccessories.com. In Canada, call
1-800-807-6777 or visit us at www.whirlpoolparts.ca.

Part Number                             Descriptions
8171587RP                                0–5″ Metal vent periscope
4396037RP                                0″-18″ Metal vent periscope
4396011RP                               18″ – 29″ Metal vent periscope
4396014                                    29″ – 50″ Metal vent periscope
4392892                                     In-Wall metal DuraVent™ Periscope
4396028                                     Sure Connect™ venting kit  (over- the-top installation)
4396009RP                                5′ Universal connect vent, flexible dryer venting
4396010RP                                6′ SecureConnect™ vent, flexible dryer venting
4396013RB                                Dryer vent installer’s kit
4396033RP                                5′ flexible dryer venting with clamps
4396727RP                                8′ flexible dryer venting with clamps
4396004                                    Dryer offset elbow
4396005                                    Wall offset elbow
4396006RW                              DuraSafe™ close elbow
4396007RW                              Through-the-wall vent cap
4396008RP                              4″ steel dryer venting clamps – 2 pack
8212662                                    Flush mounting louvered vent hood 4″

Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path:

  • Select route that will provide straightest and most direct
    path outdoors.

  • Plan installation to use fewest number of elbows and turns.

  • When using elbows or making turns, allow as much room
    as possible.

  • Bend vent gradually to avoid kinking.

  • Use as few 90° turns as possible.
    Determine vent length and elbows needed for best
    drying performance:

  • Use following Vent system chart to determine type of vent
    material and hood combinations acceptable to use.
    NOTE: Do not use vent runs longer than those specified
    in Vent system chart. Exhaust systems longer than those
    specified will:

  • Shorten life of dryer.

  • Reduce performance, resulting in longer drying times
    and increased energy usage.

The Vent system chart provides venting requirements that will
help achieve best drying performance.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Install Vent System

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4″ (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.

Connect Vent

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Using a 4″ (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4″ (102 mm) clamp.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.

Level Dryer

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Check levelness of dryer from side to side. Repeat from
front to back.

NOTE: The dryer must be level for the moisture sensing system
to operate correctly.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

If dryer is not level, prop up using a wood block, use wrench
to adjust legs up or down, and check again for levelness.
Once legs are level, make sure all four legs are snug against
the ground before tightening them.

Complete Installation Checklist

  • Check that all parts are now installed. If there is an extra

  • part, go back through steps to see what was skipped.

  • Check that you have all of your tools.

  • Dispose of/recycle all packaging materials.

  • Check dryer’s final location. Be sure vent is not crushed
    or kinked.

  • For power supply cord installation, plug into an outlet.
    For direct wire installation, turn on power.

  • Check that dryer is level. See “Level Dryer”.

  • Remove film on console and any tape remaining on dryer.

  • Wipe dryer drum interior thoroughly with a damp cloth to
    remove any dust.

  • Read “Dryer Use” in your “Use and Care Guide”.

  • Set the dryer on a full heat cycle (not an air cycle) for

  • minutes and start the dryer.
    If the dryer will not start, check the following:
    ■ Controls are set in a running or “On” position.
    ■ Start button has been pushed firmly.
    ■ Dryer is plugged into an outlet and/or electrical supply
    is on.
    ■ Household fuse is intact and tight, or circuit breaker has
    not tripped.
    ■ Dryer door is closed.

  • When the dryer has been running for 5 minutes, open the
    dryer door and feel for heat. If you feel heat, cancel cycle and
    close the door.
    If you do not feel heat, turn off dryer, and check the
    following:
    ■ There may be 2 household fuses or circuit breakers for
    the dryer. Check that both fuses are intact and tight, or
    that both circuit breakers have not tripped. If there is still
    no heat, contact a qualified technician.

NOTE: You may notice an odor when the dryer is first heated.
This odor is common when the heating element is first used.
The odor will go away.

Reverse Door Swing (Optional)

29″ Super Wide Side-Swing Door

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Place towel on top of dryer to avoid damaging the surface.
NOTE: Magnetized screw driver is helpful.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove screws attaching hinges to door.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove screws at top, bottom, and side of door (4 screws)
that hold the inner and outer door together. Holding door over
towel on dryer, grasp sides of outer door and lift to separate it
from inner door. Set outer door aside.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove the door catch, bezel, and plug from the inside of
the inner door by squeezing and pulling/pushing them. Place
the door catch, bezel, and plug on the sides opposite from
where they were.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Rotate outer door 180º and set it back down on inner door.
Reattach outer door panel to inner door panel so handle is
on the side where hinges were just removed. Insert 4 door
screws.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Flip door over so handle side is down.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Remove door strike and door strike plug from dryer cabinet.
Insert the door strike into door strike plug hole and secure
with screw. Insert door strike plug into original door strike
hole and secure with screw.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Use a small, flat-blade screwdriver to gently remove 4 hinge
hole plugs on left side of dryer cabinet. Transfer plugs into
hinge holes on opposite side of dryer cabinet.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

NOTE: Two people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer
cabinet. Tighten screws halfway. Position door so large
end of door hinge slot is over screws. Slide door up so
screws are in bottom of slots. Tighten screws. Insert and
tighten top screws in hinges.

Electric Dryer W10514172A/W10514174A-SP Installation
Manual

Close door and check that door strike aligns with door
catch. If it is needed, slide door catch left or right within slot
to adjust alignment.

Troubleshooting
See the Use and Care Guide or visit our website and reference
Frequently Asked Questions to possibly avoid the cost of a
service call.

Read More About This Manual & Download PDF:

Electric Dryer W10514172A/W10514174A-SP Installation Manual – Optimized PDF
Electric Dryer W10514172A/W10514174A-SP Installation Manual – Original PDF

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Whirlpool User Manuals

Related Manuals