Homedics Total Clean UV-C Tower Air Cleaner Manual AR-35
- June 8, 2024
- Homedics
Table of Contents
- IMPORTANT SAFETY INSTRUCTIONS:
- Main Features of the HoMedics Tower Air Cleaner
- Technical Specifications
- Control Panel
- Operating Instructions
- Cleaning the True HEPA Filters
- Replacing True HEPA Filter
- Replace UV-C Bulb Indicator
- PP-AROTUV, visitwww.homedics.com.**
- Replacing the UV-C Bulb
- Cleaning and Maintenance
- Troubleshooting
- Limited TWO Year Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Homedics Total Clean UV-C Tower Air Cleaner AR-35
IMPORTANT SAFETY INSTRUCTIONS:
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC
SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:
- Always unplug the air cleaner from the electrical outlet immediately after using and before cleaning.
- Keep cord away from heated surfaces.
- Always place the air cleaner on a firm, level surface.
- Always place the air cleaner at least six (6) inches away from walls and three (3) feet from heat sources such as stoves, radiators, or heaters.
- DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered.
- DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
- DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
- DO NOT place in or drop into water or other liquid.
- Keep dry – DO NOT operate in a wet or moist conditions.
- Check your air cleaner cord and plug connections. Faulty wall outlet connections or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tightly in the outlet.
WARNING – TO REDUCE THE RISK OF BURNS, FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS:
- Extreme caution is necessary when any air cleaner is used by or near children or invalids and whenever the air cleaner is left operating and unattended.
- Always unplug the air cleaner when not in use.
- Do not operate the air cleaner with a damaged cord or plug, or after the air cleaner malfunctions, has been dropped or damaged in any manner. Return to HoMedics Consumer Relations for examination, electrical or mechanical adjustment, or repair.
- This air cleaner is not intended for use in bathroom, laundry areas and similar moist indoor locations. Never locate air cleaner where it may fall into a bathtub or other water container.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas where it can be tripped over.
- To disconnect the air cleaner, first turn controls to the OFF position, then remove plug from outlet.
- Do not tilt or move the air cleaner while it is in operation. Shut off and remove plug from outlet before moving.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the air cleaner.
- To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surface, like a bed, where openings may become blocked.
- Use this air cleaner only for its intended use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
- DO NOT use outdoors.
This product earned the ENERGY STAR by meeting strict energy efficiency
guidelines set by the US EPA. US EPA does not endorse any manufacturer claims
of healthier indoor air from the use of this product.
The energy efficiency of this ENERGY STAR qualified model is measured based on
a ratio between the model’s CADR for Dust and the electrical energy it
consumes, or CADR/Watt.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE
Input voltage: 120 V
Rated Frequency: 60 HZ
Power: 65 Watts
Weight: 12.5 lbs
Noise Level: <60 dB
Unit Height: 28″
Main Features of the HoMedics Tower Air Cleaner
Technical Specifications
NOTE: This appliance has a polarized plug (one blade is wider than the
other). To reduce the risk of shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in an
electric shock hazard.
Control Panel
Operating Instructions
Turning the Unit On
- Take the air cleaner out of the box and remove the clear protective plastic bag.
- Place the air cleaner on a firm level surface.
- Before turning the air cleaner ON, you need to confirm that the filters are firmly in place and did not become loose during shipping.
-
To check filters, open the rear cover by gently pushing down on therelease tab on the top of the rear grill cover. Fig. 1
Fig. 1 -
Open the grill cover outward until the tabs at the bottom of the grill cover easily slide away from the unit. Fig. 2
Fig. 2 -
The True HEPA filters will be resting inside the unit. Make sure that the filters are firmly seated inside of the unit. Fig. 3
Fig.3 -
Place the tabs at the bottom of the grill cover into the base of the unit.
Gently push the grill cover back into place until you hear a click sound indicating that the grill cover is firmly latched. Fig. 4
Fig.4
Connect the power cord into a standard AC outlet.
NOTE: Unit will not operate unless filters and grill are properly installed.
-
On/Off and Speed Settings
To turn the air cleaner on, press the ON/OFF button on the control panel.
When the air cleaner is on, the ON/OFF button on the control panel will be lit and the air cleaner will start to operate on LOW speed.
Once the air cleaner is ON, press the SPEED+ button to increase the fan speed to the MED setting. Press again to increase the fan speed to HIGH setting. To decrease the fan speed, press the SPEED– button until your desired settingis reached. The fan speed setting is indicated by the illuminated ring around the fan symbol.
***** To turn the air cleaner OFF, simply press the ON/OFF button on the control panel. -
Timer
There are four possible timer settings: 2 (two) hours, 4 (four) hours, 8 (eight) hours, and 12 (twelve) hours. To activate the timer press the TIMER+ button on the control panel. Each time the + button is pressed, it will display the successive settings. To return to a setting already passed, press the TIMER– button. Once a timer setting has been selected, it will remain displayed on the TIMER screen. To operate continuously, cycle down through all timer settings until no timer setting is displayed. -
Oscillation
To activate the oscillation feature, press the button. To stop oscillation, press the button a second time. Unit will not automatically realign with foot when oscillation is stopped. To achieve alignment, stop oscillation at the moment the body becomes aligned with the foot. -
Germicidal UV-C Bulb
The UV-C technology in this air cleaner kills germs, bacteria and viruses. To activate the UV-C bulb, press the UV-C button on the control panel. To turn the UV C bulb off, press the button again. -
Clean Filter Indicator
The air cleaner is equipped with a CLEAN FILTER indicator to let you know when it is time to clean the True HEPA filters, about every 480 hours of use. When the True HEPA filters are ready to be cleaned, the CLEAN FILTER indicator will light up on the control panel.
If the air cleaner is used daily, we recommend cleaning the True HEPA filters more frequently.
Once the True HEPA filters have been cleaned, press and hold the CLEAN FILTER button until it beeps to reset the Indicator.
Cleaning the True HEPA Filters
Make sure that the air cleaner is turned OFF and unplugged from the outlet before cleaning.
-
Open the rear grill cover by gently pushing down on the tab on the top of the grill cover. Fig. 5
Fig. 5 -
Open the grill cover outward until the tabs at the bottom of the grill cover easily slide away from the unit. Fig. 6
Fig. 6 -
Remove the True HEPA filters from the main unit. Fig. 7
Fig. 7
_ Note: There are two True HEPA filters in _this air cleaner. -
Use the brush attachment with your vacuum cleaner. Run the attachment along both sides of the True HEPA filters, cleaning thoroughly between the accordion folds of the filters. Fig. 8
Fig. 8 -
Place the clean True HEPA filters back in the main unit, making sure they are firmly seated inside the unit. Fig. 9
Fig. 9 -
Place the tabs at the bottom of the grillcover into the base of the unit. Gently push the grill cover back into place until you hear a click sound indicating that the grill cover is firmly latched. Fig. 10
Fig. 10
DO NOT USE WATER OR ANY HOUSEHOLD CLEANERS OR DETERGENTS TO CLEAN THE TRUE HEPA FILTERS.
Replacing True HEPA Filter
With regular cleaning the life of the True HEPA filter is approximately 12-18
months under typical household usage and conditions. We recommendreplacing
your filters every year. To purchase replacement True HEPA filters, model #
AT-OFL, go back to your retailer (where you purchased your air cleaner), or
visit www.homedics.com.
After cleaning or replacing the True HEPA filters, be sure to reset the filter
indicator by pressing the CLEAN/RESET FILTER INDICATOR BUTTON for several
seconds until an audible chime sounds and the light turns off.
Replace UV-C Bulb Indicator
The UV-C Bulb is equipped with a REPLACE UV-C BULB indicator to let the user know it is time to replace the bulb. When the bulb needs to be changed, the REPLACE UV-C BULB indicator will light up on the control panel. Once the UV-C bulb has been replaced, press and hold the REPLACE UV-C BULB button until it beeps to reset the indicator. To purchase a replacement UV-C bulb, **model
PP-AROTUV, visitwww.homedics.com.**
Replacing the UV-C Bulb
- Unplug unit and allow bulb to cool.
- Open and remove the rear grill cover.
- Remove the upper True HEPA filter.
- Use a screwdriver to remove two screws and detach the metal UV-C bulb cover.
- Grasp the UV-C bulb firmly and pull it from the bulb socket.
- Replace the new UV-C bulb and push it into the bulb socket.
- Replace the metal UV-C bulb cover.
- Replace the rear grill cover.
NOTE: UV-C bulb contains Mercury (Hg). Dispose of according to Local, State and Federal Law / www.lamprecycle.org
Cleaning and Maintenance
For best performance, we recommend:
- Vacuum the True HEPA filters using the brush attachment of your vacuum cleaner once a month
- NEVER use water or any household cleaners or detergents to clean the True HEPA filters
- Clean off the outside of the unit with a dry cloth once a month
- NEVER use water, wax, polish, or any chemical solution to clean the outside of the unit
- Clean off the grill cover using a damp cloth or the brush attachment of your vacuum once a month
- NEVER use wax, polish, or any chemical solution to clean the grill cover
- Replace the True HEPA filters every 12-18 months
- If you will not be using the air cleaner for an extended period of time, please store in the box, or a cool, dry place.
Troubleshooting
Problem: Possible Cause: Solution
Unit will not operate:
- Unit is not plugged in
- No power at unit:
- Plug unit in
- Press the POWER button to turn the power on
- Check circuits, fuses, try a different outlet
Reduced airflow or poor filtering:
- The front grill may be blocked
- True HEPA filters may be clogged
- Check to make sure nothing is blocking the back grill and air outlet
- Check and clean filters
- Replace the filters
Excessive noise”
- The unit is not level:
- Place the unit on a flat, even surface
Limited TWO Year Warranty
HoMedics sells its products with the intent that they are free of defects in
manufacture and workmanship for a period of two years from the date of
original purchase, except as noted below. HoMedics warrants that its products
will be free of defects in material and workmanship under normal use and
service. This warranty extends only to consumers and does not extend to
Retailers.
To obtain warranty service on your HoMedics product, contact a Consumer
Relations Representative by telephone at
1-800-466-3342 for assistance. Please
make sure to have the model number of the product available.
HoMedics does not authorize anyone, including, but not limited to, Retailers,
the subsequent consumer purchaser of the product from a Retailer or remote
purchasers, to obligate HoMedics in any way beyond the terms set forth herein.
This warranty does not cover damage caused by misuse or abuse; accident; the
attachment of any unauthorized accessory; alteration to the product; improper
installation; unauthorized repairs or modifications; improper use of
electrical/ power supply; loss of power; dropped product; malfunction or
damage of an operating part from failure to provide manufacturers recommended
maintenance; transportation damage; theft; neglect; vandalism; or
environmental conditions; loss of use during the period the product is at a
repair facility or otherwise awaiting parts or repair; or any other conditions
whatsoever that are beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in
the country in which the product is purchased. A product that requires
modifications or adoption to enable it to operate in any other country than
the country for which it was designed, manufactured, approved and/ or
authorized, or repair of products damaged by these modifications is not
covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE
SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE
COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE
NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT
SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR
PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHINTHE EFFECTIVE PERIOD OF THE
WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE
MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT
SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired,
repackaged and/or resealed products, including but not limited to sale of such
products on Internet auction sites and/ or sales of such products by surplus
or bulk resellers. Any and all warranties or guarantees shall immediately
cease and terminate as to any products or parts thereof which are repaired,
replaced, altered, or modified, without the prior express and written consent
of HoMedics.
This warranty provides you with specific legal rights. You may have additional
rights which may vary from state to state. Because of individual state
regulations, some of the above limitations and exclusions may not apply to
you.
For more information regarding our product line in the USA,
pleasevisit: www.homedics.com