Specifications:

  • Gas Detected: Carbon Monoxide
  • Operating Voltage: N/A
  • Recommended Batteries: N/A
  • Battery Life: N/A
  • Standby Power Consumption: N/A
  • Alarm Power Consumption: N/A
  • Sensor Type : Electrochemical
  • Certification: EN 50291-1-2018
  • Alarm Method: Audible and Visual
  • Alarm Threshold: 20 PPM
  • Low Battery Warning: Audible and Visual
  • Battery Hush Warning: Audible and Visual
  • Operating Environment: N/A
  • Storage and Transport Environment: N/A
  • Measurement Range: N/A
  • Dimensions: N/A
  • Weight: N/A
  • Service Life: N/A
  • Warranty: N/A

Product Usage Instructions

Placement of the Carbon Monoxide Detector:
To ensure proper functionality, place the CO detector within 1 to 3 meters of potential carbon monoxide sources such as gas appliances like water heaters, boilers, and fireplaces.

In a Room with Combustion Appliances:
Mount the CO detector on the ceiling, at least 30 cm away from walls, or on the wall, 15 cm below the ceiling.

In a Room without Combustion Appliances:
Install the carbon monoxide detector at breathing height.

Installation:
Follow the manufacturer’s instructions provided in the user manual to correctly install the CO detector.

Function and Meaning of Light and Sound Signals:

  • CO Alarm: The CO detector will sound an alarm based on the concentration of carbon monoxide in the room. Different levels of PPM trigger alarms at specific intervals with corresponding audible and visual signals.
  • Low Battery Voltage: A distinct sound and visual indication will alert you when the batteries need replacement. It is crucial to replace the batteries promptly to ensure continued protection.

FAQ (Frequently Asked Questions)

What should I do if the CO alarm goes off?
In case of an alarm, follow these steps:

  1. Open all doors and windows.
  2. Turn off all possible sources of carbon monoxide.
  3. If the alarm persists, evacuate the area and keep doors and windows open until the alarm stops.
  4. If anyone shows symptoms of carbon monoxide poisoning, seek medical help immediately.
  5. After the alarm stops, have a certified professional inspect all potential sources of carbon monoxide before reactivating them.

INTRODUCTION

  • Carbon monoxide is a very dangerous and poisonous gas produced by incomplete combustion. You cannot see or smell carbon monoxide and it is absorbed by the blood. With prolonged exposure to small concentrations, people experience symptoms such as headache, nausea and dizziness. Exposure to high concentrations for a short period of time can be fatal.
  • This FITO carbon monoxide detector features an advanced electrochemical sensor and an LCD display. The carbon monoxide alarm alerts you with sound signals and shows the concentration of carbon monoxide from 20 PPM.

Ideally suited for:
Complies with: EN 50291-1-2018
The CE mark affixed to this product confirms that it complies with the European Directives applicable to this product.

What to do in case of alarm:

  1. Open all doors and windows
  2. Turn off all possible sources of carbon monoxide.
  3. If the alarm persists after these actions, evacuate the room. Leave doors and windows open and do not re-enter the room until the alarm has stopped
  4. Have anyone showing symptoms of carbon monoxide poisoning such as headache and nausea checked by a medical professional.
  5. When the alarm has stopped sounding, you can enter the room in question. Do have all possible sources of carbon monoxide checked by a certified installer before turning it on again.

Specifications

  • Detected gas: Carbon monoxide
  • Voltage: 3V, 2 pieces AA alkaline batteries
  • Recommended batteries: GP GN15A or Energizer E91
  • Battery life: ± 3 years
  • Standby consumption: ≤ 20 μA (average)
  • Alarm consumption: ≤ 50 mA (average)
  • Sensor type: Electrochemical
  • Certification: EN50291-1:2018
  • Alarm:
    • 30PPM: after 120 minutes
    • 50PPM: 60-90 minutes
    • 100PPM 10-40 minutes
    • 300PPM within 3 minutes
  • Alarm value: 85dB at 3 meters
  • Low battery warning: 30 days
  • Battery warning hush : 9 hours
  • Working environment: -10⁰ ~ 45⁰ C 25% ~ 95%RH
  • Storage and transport environment: -20⁰ ~ 50⁰ C 10% ~ 95%RH
  • Measuring range: maximum 40 m² within 1 room
  • Dimensions: 120 x 80 x 37 mm
  • Weight: 102 grams
  • Lifespan: ± 10 years after production
  • Warranty: 3 years after purchase

Installation of the carbon monoxide detector:

Where to place a CO detector:
It is recommended to place at least a carbon monoxide detector at least 1 and no more than 3 meters from any appliance that could potentially generate carbon monoxide. For example geysers, boilers and fireplaces.

In rooms with a combustion appliance:
Place this CO detector on the ceiling, at least 30 cm from walls or on the wall, 15 cm below the ceiling.

In room without a combustion appliance:
Place the carbon monoxide detector at breathing height

Never place a carbon monoxide detector:

  • Behind a cupboard or curtains
  • Near a ventilation grill, next to a window above a sink or cooking appliance.
  • Next to a window or door
  • In enclosed spaces
  • In dusty and dirty rooms
  • In rooms where the temperature can fall below -10⁰ C and above 45⁰C

Installation

  • Choose the right place to install your carbon monoxide detector
  • Insert the supplied batteries into the detector.
  • Pay attention to the plus and minus!
  • The carbon monoxide detector gives a signal and the green LED flashes continuously for 60 seconds to indicate that the carbon monoxide detector is starting up. The display shows the number of seconds remaining.
  • When the start-up procedure is complete, the CO Alarm goes into wake-up mode:
  • The green LED flashes 1 time every 40 seconds
  • When placing the CO Alarm on a desk or nightstand, slide it onto the mounting bracket until you hear a click.
  • If you place the carbon monoxide detector on the wall or ceiling, attach the base plate with the supplied plugs and screws, then slide the detector onto the base plate until you hear a click.
  • Test your carbon monoxide detector by pressing the test button
    • The green “power” LED light flashes 1 time
    • The orange “fault” LED light flashes 1 time
    • The red “alarm” LED light flashes 1 time
    • The detector sounds the alarm signal ( 4 beeps) twice while the red LED light blinks.
  • Your carbon monoxide detector is now installed.

Function and meaning of light and sound signals

Normal situation:

  • The green LED light flashes once every 40 seconds
  • The LCD screen alternately displays the ambient temperature in degrees Celsius and the concentration of carbon monoxide in PPM from 20 PPM every 40 seconds

CO alarm:

  • When the CO concentration (PPM) in the room is too high, the carbon monoxide will alarm as follows:
    • 30 PPM: Alarm after 120 minutes
    • 50 PPM: Alarm between 60 and 90 minutes
    • 100 PPM: Alarm between 10 and 40 minutes
    • 300 PPM : Alarm within 3 minutes
  • In alarm, the carbon monoxide detector emits 4 loud beeps, 2 seconds of silence , followed by 4 loud beeps. The red LED light flashes continuously.

Hush mode:

  • When the carbon monoxide detector alarms, you can silence the alarm once for 10 minutes by pressing the test/silence button.
  • The red LED light will continue to flash continuously to indicate that the carbon monoxide detector is in a hush mode.
  • During those 10 minutes, open all windows and doors to reduce the carbon monoxide concentration.
  • After the 10 minutes, the alarm will sound again if the concentration of carbon monoxide has not dropped below 50PPM.
  • If the concentration of carbon monoxide is higher than 200PPM, the hush mode cannot be activated.

Low battery voltage:

  • 1 beep every 40 seconds is an indication from your carbon monoxide detector that the batteries need to be replaced.
  • The orange “fault” LED light will flash continuously.
  • The battery voltage at the time this signal starts is sufficient to sound the low battery signal for 30 days and to alarm for 4 minutes.
  • Note: The carbon monoxide detector will not protect you when the batteries are low, therefore replace the batteries as soon as possible.

Low battery voltage hush:
You can silence the low battery voltage signal for 9 hours by pressing the Test – Silence button.

Error warning:

  • 2 short beeps every 40 seconds
  • The orange “fault” LED light flashes continuously
  • The LCD display shows the text “Err”
  • Your carbon monoxide detector is not functioning properly and should be replaced as soon as possible.

End of life warning:

  • 3 short beeps every 40 seconds
  • The orange “fault” LED light flashes continuously
  • The LCD display shows the text “End”
  • Your carbon monoxide detector has reached the end of its service life and should be replaced with a new one as soon as possible.

Alarm memory:

  • The red “alarm” LED light blinks once every 40 seconds
  • The text “AL” appears on the LCD display
  • Your carbon monoxide detector has measured high concentrations of carbon monoxide in the past 48 hours.
  • You can turn off this notification by pressing the ” test / silence” button. The notification disappears automatically 48 hours after alarming.

Maintenance

  • Test your carbon monoxide detector monthly by pressing the test button.

    • The green “power” LED blinks 1 time
    • The orange “fault” LED light blinks 1 time
    • The red “alarm” LED light blinks 1 time
    • The detector sounds the alarm signal ( 4 beeps) twice while the red LED light blinks.
      To test the 85 dB at 3 meters, hold down the test button, after 8 alarms, the carbon monoxide detector will sound the sound of the real carbon monoxide alarm.
  • Vacuum the carbon monoxide monthly with the soft brush of the hoover.

  • Never use detergents or other solvents to clean the carbon monoxide detector.

  • Do not use air fresheners, hair spray and other aerosols near the carbon monoxide detector.

  • Never paint your carbon monoxide detector!

Limitations of a carbon monoxide detector

  • This carbon monoxide alarm is designed to alert persons when the concentration of carbon monoxide may lead to acute health problems.

  • For persons with specific medical conditions, this carbon monoxide alarm may not provide sufficient protection.

  • If in doubt, consult a doctor.

  • In the following situations, the CO Alarm will not alarm:

    • When the battery had been removed or was not functioning.
      Therefore, test regularly.

    • If the carbon monoxide cannot reach the detector, for example if the carbon monoxide is released into another room or the carbon monoxide detector is attached in an improper location. See paragraph “Where to place a CO detector”.

    • If people do not hear the alarm. A person could possibly not be woken up by the alarm in case of excessive consumption of alcohol and/or drugs.

    • The service life of this carbon monoxide detector is 10 years.

Product Warranty

  • With normal use and maintenance, the manufacturer guarantees this product against material and/or production defects for the period of 3 years from the original date of purchase by the consumer, with a maximum of 5 years from the date of production.
  • Excluded are damages caused by accidents or abuse.
  • If the product is defective within the specified period, it will be replaced or repaired free of charge. Do not attempt to open, repair or tamper with the product yourself as this will invalidate the warranty.
  • Complaints can be reported to your point of purchase or at www.fito.eu, CONTACT tab

Disposal instruction

The carbon monoxide detector including the batteries must not be disposed of in household waste. Please dispose of it at a small household waste collection point in your area.

ABOUT COMPANY

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals