LUCCI Array DC Ceiling Fan Instruction Manual

June 3, 2024
Lucci

DC Ceiling Fan
Instruction Manual
LUCCI Array DC Ceiling Fan LUCCI ARRAY DC CEILING FAN

CAUTION
READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION.

THANK YOU FOR PURCHASING

Thank you for purchasing the latest in energy saving ceiling fans. This fan runs on DC (direct current) power which gives it the benefit of being super energy efficient whilst  still maintaining high volume air-movement and silent operation.
Energy saving – The DC motor is the latest technology in fan design. Its highly efficient motor saves up to 65% more energy than ceiling fans with traditional AC motors.
Silent operation – This DC fan motor is programmed with a stabilised current which efficiently reduces motor noise.
Low operating temperature – The DC power is managed effectively which brings down the motor operating temperature to less than 50℃. This results in a much cooler  motor than a standard AC fan and increases the longevity of the motor.
6 speed remote control – Regular AC ceiling fans usually come with only 3 speeds, this DC fan comes complete with a 6 speed remote, which gives a greater choice of comfort levels.

SAFETY PRECAUTIONS

  1. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless  they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  2. Children should be supervised to ensure that they do not play with the appliance.

  3. An all-pole disconnection switch must be incorporated into the fixed wiring, in accordance with local wiring rules.
    WARNING:
    FOR SAFE USE OF THIS FAN AN ALL-POLE DISCONNECTION MUST BE INCORPORATED INTO THE FIXED WIRING IN ACCORDANCE WITH THE  WIRING RULES.
    As outline in clause 7.12.2 of AS/NZS 60335-1 for meeting the minimum electrical safety of this standard.
    Please note warranty will be void if installation is without a means for an all-pole disconnection incorporated in the fixed wiring in accordance with the wiring rules.
    Example: If a fan is connected to a circuit that can be isolated via an allpole safety switch at the switchboard, then this is considered to be an all-pole disconnection to the ceiling fan electrical circuit, meeting the requirements of clause 7.12.2 of AS/NZS 60335.1. A single-pole switch on the active of the receiver input of remote control must also be included in the wiring, and located the same room as the ceiling fan.

  4. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
    Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous  substances can leak into the ground water and get into the food chain, damaging your health and well-being.

  5. The structure to which the fan is to be mounted must be  capable of supporting a weight of 17kg.

  6. The fan should be mounted so that the blades are at least 2.1 m above the floor.

  7. This fan is suitable for indoor, alfresco and coastal areas where the fan is fully undercover with a minimum of 1 wall. This fan is not waterproof. When installed in an  alfresco or coastal area, the ceiling fan must be positioned in a location protected from water, wind and dust. Exposure to these elements will void the warranty.  Mounting the fan in a situation where it is subject to water or moisture is dangerous and may increase the risk of damage, injury or electrical shock and will void the  arranty.

  8. Must be assembled and installed by a licensed electrician.

  9. WARNING: If unusual wobbling or oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably  qualified persons.

  10. The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.

  11. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan; that the mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.

PARTS LIST

  • Unpack your ceiling fan carefully. Remove all parts and hardware.
  • Lay out all the components on a smooth non-scratch surface and make sure there are no components missing before assembling. If parts are missing, return the  complete product to the place of purchase for inspection or replacement.
  • Check whether the ceiling fan has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product  to the place of purchase for inspection, repair or replacement.
  • Examine all parts, you should have the following:

LUCCI Array DC Ceiling Fan - fig

1 Mounting bracket x1 set 6 Bottom cover x1
2 Fan assembly x1 set 7 Motor housing x 1 set
3 Blades x 3 pcs 8 Mounting bracket screws x4
4 Light kit plate x1 pcs 9 Blade Support Plates x3
5 GX53 lamp x 1 set 10 Spare screw for fan blade x 1
11 Remote receiver and Remote controller, screw, battery, holder x 1 set

INSTALLING THE FAN

TOOLS REQUIRED:
– Phillips / flat head screwdriver
– Pair of pliers
– Adjustable spanner
– Step ladder
– Wire cutter
– Wiring, supply cable as required by local provincial and national wiring codes and regulations

INSTALLING THE MOUNTING BRACKET

  • The ceiling fan must be installed in a location so that the blades are spaced 300mm from the tip of the blade to the nearest objects or walls.
  • Install the hanging bracket to the ceiling joist or structure that is capable of carrying a load of at least 17kg, with 4 long screws provided. Ensure at least 30mm of the screw is threaded into the support. (Fig. 2)

LUCCI Array DC Ceiling Fan - fig 1

NOTE: The bracket screws provided are for use with wooden structures only. For structures other than wood, the appropriate screw type MUST be used. Ensure the screws  used are suitable for the Zmounting surface and the surrounding environment.

ANGLED CEILING INSTALLATION
The hanging system of this fan is ONLY suitable for flat ceiling installation.
DO NOT install the fan on an angled ceiling.

HANGING THE FAN TO MOTOR ASSEMBLY

  • Install the motor housing (1) onto the motor assembly. (Fig.3)
  • Lift the fan assembly up to the mounting bracket. Hang the fan assembly onto the J-hook (2) of the mounting bracket. (Fig.4)

LUCCI Array DC Ceiling Fan - fig 2

Complete the electrical wiring according to the ‘ELECTRICAL WIRING DIAGRAM’ section below.

ELECTRICAL WIRING DIAGRAM THE FAN

PREPARE AND COMPLETE THE ELECTRICAL WIRING — WIRING DIAGRAM (FIG. 5)
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.
NOTE: IF THERE ARE TWO OR MORE DC CEILING FANS INSTALLED IN THE ONE LOCATION, AN ISOLATION SWITCH IS REQUIRED FOR EACH  CEILING FAN. THIS IS REQUIRED WHEN PROGRAMMING THE REMOTE AND RECEIVER TO PAIR TOGETHER.
Ensure the motor earth wire is connected to the single earthing terminal block “1” in the diagram below. (Fig. 5)LUCCI Array DC Ceiling Fan - fig
3

From mains supply to mounting bracket terminal block: (Fig. 5)

  1. Connect the live supply wire to the “L” terminal of the terminal block on the mounting bracket.

  2. Connect the neutral supply wire to “N” terminal of the terminal block on the mounting bracket.

  3. Connect earth wire to the earth terminal of the terminal block on the mounting bracket.
    From mounting bracket to receiver and motor: (Fig. 5)

  4. Click together the supply wires from the mounting bracket to the input of the DC motor receiver.

  5. Click together the output wires of DC motor receiver to the input wires of the fan motor and the light kit via the quick connector plugs.

  6. Connect the earth wires from the fan motor to the single earthing terminal block “1” in the diagram.

INSTALL THE FAN ASSEMBLY TO THE MOUNTING BRACKET

  • After completing the electrical connection at the mounting bracket terminal block, connect the ceiling fan wiring via the quick connector plugs.

NOTE: Ensure the earth wiring is secure and correct, by performing an earthing continuity test from the fan’s accessible metal body back to the earth terminal at the terminal block on the mounting bracket.

Install the fan assembly to the mounting bracket
There are 4 screws pre-installed on the mounting bracket: (Fig.6)
– Loosen two canopy screws with star washer (2) by half thread from the mounting bracket. (For L-shape lot on canopy to be mounted).
– Loosen two canopy screws (1) and remove from the mounting bracket.LUCCI
Array DC Ceiling Fan - fig 4

  • Lift the hanging canopy (3) of the fan assembly up to the mounting bracket and let the L-shape slot on the hanging canopy go through the two canopy screws with star  washer (2). (Fig.7)
  • Turn the hanging canopy until it locks in place at the end section of the L-shape slot, ensure the star washer are between the hanging canopy (3) and screw head. Secure it  by tightening the two canopy screws with star washer (2). (Fig.7)
  • Secure and tighten the canopy screws (1) to the mounting bracket. The hanging canopy (3) shall have 4 screws (1) & (2) in total. Avoid damaging the electrical wiring  prepared previously when hanging the canopy. (Fig.8)

LUCCI Array DC Ceiling Fan - fig 5

  • Align the arrow mark (4) on the hook surface of the motor housing (5) up to the screws (2) of hanging canopy (3). (Fig.9)
  • Finally attach the motor housing (5) to the mounting bracket, secure it by pushing the hooks of the motor housing into the slot holes of the hanging canopy and turn it anti clockwise.

LUCCI Array DC Ceiling Fan - fig 6

INSTALLING THE FAN BLADE AND LIGHT KIT

BLADE ATTACHMENT (Fig.10)

  1. Before installing the blades, remove the blade screws with lockwashers from the bottom of fan motor.

  2. Orientate the blade Support plate and fan blade onto the fan assembly (Fig.10)
    Mount the fan blade onto the fan assembly using three blade screws with lockwashers in step 1, (Fig.10).
    Ensure all screws are tightened evenly to reduce the chance of warping or unbalancing.
    Take care not to over tighten the screws, as this can damage the blades Take note the correct side of the blades with the marking “THIS SIDE UP” faces the ceiling.

  3. Repeat for the remaining Two fan blades and support plates.
    To secure the three blade support plates and the fan blades to the fan assembly, tighten all screws with lockwashers.

LUCCI Array DC Ceiling Fan - fig 7

INSTALLATION OF LIGHT KIT (Fig. 11)
NOTE: The light kit must be installed by a licensed electrician.

  1. Loosen the screw (1) from the fan bracket. (Fig. 11)
  2. Align the two slot screws with the keyhole slots (2) of the light kit plate. (Fig. 11)
  3. Turn the light kit plate counterclockwise until the slot screws are firmly at the end of the slots (2).
  4.  Secure screw (1) to the lamp shade bracket. Tighten all three screws. Do not over-tighten.

LUCCI Array DC Ceiling Fan - fig 8

INSTALLATION OF LAMP (Fig. 12)

  • Install the lamp on the fan assembly then secure it by turning clockwise. (Fig. 12)

LUCCI Array DC Ceiling Fan - fig 9

INSTALLATION OF BOTTOM COVER (Fig. 13)

  • If no lamp is required, Install the bottom cover to the fan assembly then secure it by turning clockwise. (Fig.13)

LUCCI Array DC Ceiling Fan - fig 10

INSTALLATION OF THE REMOTE CONTROL HOLDER (Fig. 14)

  1. Locate a suitable wall to fix the remote control holder with the 2 screws. (Fig.14a).
  2. Slide the remote into the holder to rest the remote. (Fig. 14b)

LUCCI Array DC Ceiling Fan - fig 11

USING YOUR CEILING FAN

NOTE: The remote and receiver will need to be paired after the installation of the ceiling fan.
NOTE: When two or more ceiling fans are installed in one location, please refer to the instruction on the next page.
PAIRING REMOTE & RECEIVER – WHEN 1 DC CEILING FAN IS INSTALLED IN ONE LOCATION
NOTE: Ensure that you have installed a single pole disconnection switch in the fixed wiring for the fan.
NOTE: Ensure power to the receiver is ON prior to pairing the remote with the receiver.

  • Turn OFF the mains supply to the fan by on/off wall switch.
  • Install the batteries into the remote. Please make sure the polarity of the battery is correct.
  • Turn ON the power to the receiver.
  • Press and hold the button on the remote for 3-5 seconds within 30 seconds of switching the power ON to the receiver of the ceiling fan.
  • There will be a notification ‘beep’ sound from the receiver to indicate that the paring process is successful.
  • Turn ON the fan and change the speed of the ceiling fan via the remote to check the operation and successful paring.
  • If pairing has been unsuccessful, repeat these set of steps again

PAIRING REMOTE AND RECEIVER – WHEN 2 OR MORE DC CEILING FANS ARE INSTALLED IN ONE LOCATION
When two or more ceiling fans are located near each other, you may desire to have the remote/receiver for each fan paired so that the operation of one fan does not affect  the operation of the other fans.
NOTE: Ensure that you have installed a single pole disconnection switch in the fixed wiring for each fan.
NOTE: Ensure power to the Receiver is ON prior to pairing the remote with the receiver.

Remote / Receiver pairing for ceiling fan 1:

  • Turn OFF the mains supply to the receivers of both ceiling fans 1 and 2.
  • Install the batteries into the remote. Please make sure the polarity of the battery is correct.
  • Turn ON the power to receiver 1. Keep the power OFF to receiver 2. (Each ceiling fan must have its own isolation switch, so that only the ceiling fan that needs to be paired with the remote will be ON).
  • Press and hold the “ ” button of remote 1 for 3-5 seconds within 30 seconds of switching the power ON to the receiver of ceiling fan 1.
  • There will be a notification ‘beep’ sound from the receiver to indicate that the paring process is successful.
  • Turn ON the fan and change the speed of the ceiling fan 1 by the remote to check the operation and successful paring.
  • If pairing has been unsuccessful, repeat these set of steps again

Remote / Receiver paring for Ceiling fan 2:

  • Turn OFF the mains supply to the receivers of both ceiling fans 1 and 2.
  • Install the batteries into the remote. Please make sure the polarity of the battery is correct.
  • Turn ON the power to receiver 2. Keep the power OFF to receiver 1. (Each ceiling fan must have its own isolation switch, so that only the ceiling fan that needs to be  paired with the transmitter will be ON).
  • Press and hold the “ ” button of remote 2 for 3-5 seconds within 30 seconds of switching the power ON to the receiver of ceiling fan 2.
  • There will be a notification ‘beep’ sound from the receiver to indicate that the paring process is successful.
  • Turn ON the fan and change the speed of ceiling fan 2 by the remote to check the operation and successful pairing.
  • If pairing has been unsuccessful, repeat these set of steps again

REMOTE CONTROL (Fig. 15)LUCCI Array DC Ceiling Fan - fig
12

  1. Reverse control
  2.  Natural wind (The fan speed automatic cycle between 1 to 6 speed)
  3. Speed control
  4. Light On/Off
  5. Fan On/Off
  6. 1.5V AAA battery x 2 pcs (Included)

The LED globe has a 3-step dimmable function which is controlled by an ON/OFF switch.
When the LED light is ON and at 100% brightness, press the light button “ON and then OFF within 3 seconds”, to dim the LED light. Repeat pressing ON and then OFF  within 3 seconds to dim further in the following sequence: 100% brightness → 50% brightness → 15% brightness → 100% brightness.
The remote has memory function. If the fan or light is turned off by the isolating switch over 7 seconds, the next time to turn on the fan or light will be on last setting

REPAIRING THE REMOTE & RECEIVER PAIRING – WHEN 1 CEILING FAN IS INSTALLED

  • If the remote and receiver lose control after installation or during use, the pairing of the remote and the receiver must be repaired.
  • Below are the operating symptoms and the steps to repair the pairing of the remote and receiver.

Symptoms:

  • Loss of control – Fan is only running at high speed after installation
  • Loss of control – No reverse function after installation
  • Loss of control – Remote cannot communicate with the receiver

Repairing Steps:

  • Switch OFF the main power to the ceiling fan for 30 seconds.
  • Switch ON the main power of the ceiling fan. Follow the same process as described in the ‘Paring remote & receiver’ section to repair the pairing.
  • Turn on and select the different speed of the ceiling fan to check the operation of the fan.

AFTER INSTALLATION

NOTE: Ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet.
If the fan was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres is quite acceptable and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting bracket and down rod are secure.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and frequency signals superimposed in the electricity for off-peak hot  water control, may cause a change in fan motor noise. This is normal. Please allow a 24-hour “settling-in” period, most noises associated with a new fan disappear during this  time.
The manufacturer’s warranty covers actual faults that may develop and NOT minor complaints such as hearing the motor run – All electric motors are audible to some extent.

CARE & CLEANING

NOTE: Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan.

  • Every 6 months periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to avoid scratching the paint finish. Please turn  off electricity power when you do so.
  • Do not soak or immerse your ceiling fan in the water or other liquids. It could damage the motor or the blades and create the possibility of an electrical shock.
  • Ensure that the fan does not come in contact with any organic solvents or cleaners.
  • To clean the fan blade, wipe with only a damp clean cloth with NO organic solvents or cleaners.
  • The motor has a permanently lubricated ball bearing so there is no need to oil.

SAFETY PRECAUTIONS FOR BATTERY

– WARNING – Keep new and used batteries away from children.
– CAUTION – Do not ingest battery—Chemical burn hazard.
– Always use 2 x AAA battery type with this ceiling fan remote controller.
– Ensure the batteries are inserted with the correct polarity.
– To prevent false operation during battery insertion or replacement, this ceiling fan must be disconnected from the supply mains.
– Remove batteries from the product when not in use for long periods of time.
– Batteries must be removed from the remote transmitter before it is discarded.
– Dispose of exhausted batteries immediately and safely (so they cannot be retrieved by children). Batteries can still be dangerous. Contact your local council to safely dispose  of the battery.
– Regularly check the product and make sure the battery box lid is correctly secured. If the battery compartment does not close securely, stop using the product and keep it  away from children.
– If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. If you suspect your child has swallowed or inserted  a button battery, immediately call the 24-hour Poisons Information Centre on 13 11 26 for fast, expert advice.
– Battery Leaks: Battery contains chemicals and should be treated as any chemical would. Take precautions when handling leaked battery chemicals. Battery chemicals should  not be placed near the eyes or ingested. Contact Poisons Information Centre on 13 11 26 for fast, expert advice.

TECHNICAL INFORMATION

Fan 54’’ ARRAY DC Fan
Fan Models SKU# 216106

Rated Voltage
Rated Wattage (Motor)
Rated wattage (Lamp)| 220-240V~ 50Hz
35W
SKU# 121363: GX53,12W, 1100lm, 3000K, 3 step-dim (Included)
Also compatible with
SKU# 121364: GX53,12W, 1100lm, 4000K, 3 step-dim (not included)
Battery for remote| 2 x AAA (Included)
Weight| 4.2kg
Canopy Dimensions| H:95mm  Dia:130mm

LUCCI CEILING FAN WARRANTY DETAIL
LUCCI FAN WARRANTY CONTACT INFORMATION:
Online Warranty Form: https://www.beaconlighting.com.au/warranty- claims
Email: [email protected]
Lucci Fan Warranty Hotline: (Free Call) 1800 602 243

THIS WARRANTY IS VALID IN AUSTRALIA ONLY
In the event of service being required, please call the Lucci Fan Warranty Hotline on 1800 602 243 between 9am & 5pm (EST) Monday to Friday. Please make sure you have  all the ceiling fan details filled out at the end of the manual before making the call.
Every Lucci ceiling fan is thoroughly inspected and tested before being released for sale. In addition to any warranty rights or conditions under statutory regulations, Lucci  warrants all its ceiling fans against defective workmanship and faulty materials for two (2) years from the date of purchase. Following this, an additional seven (7) years motor replacement warranty applies. Lucci undertakes, at its option, to repair or replace, free of charge, each product or part thereof on condition that;

  1. The fan or relevant part has not been subjected to misuse, neglect, or been involved in an accident.
  2. The repairs are not required as a result of normal wear and tear.
  3. The product was installed by a licensed electrical contractor.
  4. A copy of the original receipt of purchase is presented.
  5. 12 month warranty applies when used in any non-domestic applications.
  6. This warranty does not cover stains, scratch and scuff marks, or dents if the product is purchased through a factory outlet or to refurbished items.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and  compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality  and the failure does not amount to a major failure.
Lucci Design cannot be held responsible for any repair other than those carried out by it or one of its Authorised Service Agents. Please keep this warranty information in a  safe place. This information must be produced in the event of service being required.

Distributed by:
Beacon Lighting
140 Fulton Drive
Derrimut, Victoria, 3026, Australia
Ph +613 9368 1000
Email: [email protected]

CEILING FAN WARRANTY INFORMATION
LUCCI FAN WARRANTY CONTACT INFORMATION:
Online Warranty Form: https://www.beaconlighting.com.au/warranty-claims
Email: [email protected]
Lucci Fan Warranty Hotline: (Free Call) 1800 602 243
Complete and retain this form for your personal records and warranty purposes.

NAME…………………………………………
ADDRESS………………………………POSTCODE…………
MODEL NUMBER………………………………………………
(PO# + DATECODE Sticker here)
PO NUMBER or DATECODE ……………………………
DATE OF PURCHASE………………………………………
INSTALLING LICENSED ELECTRICIAN……………………
LICENCE No………………………………………………

ATTACH PROOF OF PURCHASE HERE
THIS COMPLETED DETAIL PAGE SHOULD BE PRODUCED AND SENT TO THE WHOLESALER OR THEIR AUTHORISED AGENTS BEFORE OBTAINING WARRANTY SERVICE LUCCI Array DC
Ceiling Fan - fig 13

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lucci User Manuals

Related Manuals