SYRIS 2.45 GHz RFID Reader User Manual
- June 7, 2024
- SYRIS
Table of Contents
SYRD245-1W
2.45 GHz RFID Reader
User Manual
Version 1.50
2019/01/22
Product Specification
Communication | 2.45 GHz Support read and write |
---|---|
Frequency | 2.40-2.48 GHz |
Channel | 316 |
RSSI | 0-255 |
LQI | 0-255 |
Programmable | Set Parameter |
LED | Multi-LED visual indication |
RS232 | RX, TX |
RS485 | +, – |
Wiegand formats | 26 bits, 34 bits, 42 bits |
Baud Rate | 2,400 bps – 115,200 bps |
Power Input | 7 VDC – 15 VDC |
Action Current | MAX 500 mA @ 12 VDC |
Operating Temperature | -20 °C to 65°C, 5 to 95%RH |
Storage Temperature | -30 °C to 85°C, 5 to 95%RH |
Dimension | 107W x 138H x 30D (mm) |
The Diagram of the System Connection
SYRD245-1W Reader can connect with 3 different interfaces:RS-485 or Wiegand or RS-232.
Use SYRD245-1W Reader Config software
Execute SYRD245_1W_Tools_V0196.exe in “SYRIS Xtive DVD-ROM\SYRD245-1\Utility\”
1. Scan Reader to get reader’s serial number and firmware version.
2. Adjust the ID number and then click “Set Reader ID” to change Reader’s ID.
3. Select communication Baud rate and then click “Set Baud rate” to change Reader’s Baud rate.
4. Adjust the number of Sec to set same card interval.
Ex. Set Same card interval to 10 sec. Reader will not receive same tag between
10 sec.
5. Set DI NO/NC to change RELAY ON/OFF mode.
6. Set reader mode to Wiegand or RS485
7. Click “Read TAG” to receive TAG information.
8. Adjust RSSI level (0~250) to filter TAG which have low RSSI signal in reader. (This function was available in version 1.30 or above.)
Ex. Set RSSI Level to 120, Reader will receive tag which RSSI are stronger
than 120.
9. Set Gain (1~13) to control reader’s read range. Level 13 is the max range
(default setting), Level 1 is the shortest read range.
10. Set Exciter ID (This function was available in version 2.03 or above.) :
This parameter should use with SYRIS exciter, default values are “0000” means
disable. If this function enable, reader will only receive tag’s signal which
include set exciter ID.
11. Reader Reset: Reset online reader. Reader will warm restart. Factory Default: All setting will set factory default.
FCC Statement
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by SYRIS Technology Corp.
Could void the user’s authority to operate this equipment.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>