PEREL Wifi Weather Station Outdoor User Manual

June 7, 2024
PEREL

PEREL Wifi Weather Station Outdoor User Manual

Introduction


To all residents of the European Union Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its life cycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.

Safety Instructions

Read and understand this manual and all safety signs before using this appliance.

  • This device can be used by children aged from 8 years and above, and persons with
    reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and user maintenance shall not be made by children without supervision.

  • This product is exclusively intended for the field of application described in this
    manual. This product should only be used as described within these instructions.

  • Do not expose the appliance to extreme temperatures, vibration or shock. · The indoor main unit is not watertight and should only be used indoors. Choose a dry and shady installation spot for the main unit. The outdoor sensor may be used and installed outdoors.

General Guidelines

  • Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.

  • All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.

  • Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.

  • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.

  • Nor Velleman nv nor its dealers can be held responsible for any damage
    (extraordinary, incidental or indirect) ­ of any nature (financial, physical…) arising from the possession, use or failure of this product.

  • Keep this manual for future reference.

Overview

Refer to the illustrations on page 2 of this manual.

diagram, engineering drawing

Sensor

1

| wind vane
---|---

2

| wind speed sensor

3

| UV sensor

4

| thermo-hygro sensor

5

| rain collector

6

| bubble level

7

| solar panel

8

| U-bolt

9

| battery compartment

10

| reset button

11

| LED indicator

Display

1

| Time
---|---

2

| Moon phase

3

| Barometric pressure

4

| Weather forecast

5

| UV index

6

| Light

7

| Wind speed

8

| Wind direction

9

| Max/min daily

10

| Rain fall

11

| Outdoor temperature

12

| Outdoor humidity

13

| RF icon

14

| Indoor humidity

15

| Indoor temperature

16

| Date

17

| Wifi icon

18

| DST

Installation

Sensor

Assembling the Wind Vane and Anemometer
Slide the wind vane onto the shaft and tighten the screw, making sure the vane will spin freely.
diagram, engineering drawing
Do the same with the anemometer.
diagram, engineering drawing
Powering the Outdoor Sensor
The outdoor sensor requires two AA/R6 batteries. Open the battery compartment of the weather station. Insert the battery observing the correct polarity and re-insert the battery door.

We recommend using lithium or alkaline batteries. Rechargeable batteries are not recommended as they have lower voltages, do not operate well at wide temperature ranges and do not last long, resulting in poorer reception.
Synchronizing the Sensor and Weather Station
Before mounting the outdoor sensor, please refer to the chapter 5.2 Synchronizing the Sensor and Weather Station below.
Mounting the Outdoor Sensor
The mounting assembly includes two U-bolts and a bracket that tightens around a 1 to 2″ diameter pole (not included) using the four nuts.
diagram

Mount the sensor so that the wind directions (N, E, S and W) on the sensor are matching with the real cardinal directions. Permanent wind direction errors will occur when the sensor is not mounted correctly. Also, use the bubble level next to the rain sensor as a guide to verify that the sensor is level.
Resetting/Transmission LED
Reset the outdoor sensor in the unlikely event it is not transmitting.

  1. With an open-ended paperclip, press and hold the reset button on the sensor for three seconds to completely discharge its circuit.
  2. Remove the batteries from the batter compartment and cover the solar panel. Leave the sensor to rest for 5 minutes as this will drain the voltage.
  3. Re-insert the batteries and re-synchronize with the console (see below).
Weather Station

Powering the Weather Station
The weather station requires three AAA/R03 batteries as back-up power in case of power interruption. Open the battery compartment of the weather station. Insert the batteries observing the correct polarity and re-insert the battery door.
Connect the weather station to the mains using the included power adapter or an exact equivalent.
Installing the Weather Station
Install the weather station indoors in a dry and shady spot, away from direct sunlight or rain.

Synchronizing the Sensor and Weather Station

Synchronizing the Sensor and Weather Station
Keep the outdoor sensor close to the weather station for 30 minutes. Spin the wind cups to simulate wind, and hold the rain collector under a dripping tap to simulate rain.
Once the weather station is receiving data, follow the mounting instructions for the outdoor sensor.
To Obtain the Best Wireless Communication
To ensure proper communication, mount the outdoor sensor in a vertical position.
Also, wireless communication is susceptible to interference, distance, walls and metal barriers. Mind following points:

  • Electromagnetic Interference (EMI). Keep the weather station away from EMI, e.g. computer monitors and TV sets.

  • Radio-Frequency Interference (RFI). Devices operating at a 433 MHz frequency will
    affect the wireless communication between the outdoor sensor and the weather station. You may need to relocate those devices to avoid interference.

  • Line of Sight Rating. This weather station is rated at 100 m line of sight. However, you will typically get 30 m due to environmental barriers.

  • Metal Barriers. Keep in mind that radio waves will not pass through metal barriers such as armoured concrete.

Following is a table of barrier vs. reception factor as a guide.

Barrier Signal Reduction
glass 5-15 %
plastics 10-15 %
wood 10-40 %
brick 10-40 %
concrete 40-80 %
metal 90-100 %

Settings

Key Function
Key Description
SET
  • Hold this key to enter the setting mode.

TEMP.|

  • Press this key to view wind chill, heat index and dew point temperature.

RAIN

|

  • Press this key to view rain rate, event, rain day, rain week, rain month and rain total.
  • Hold this key pressed for 2 seconds to reset the current displayed rain value.

WIND +|

  • Press this key to view wind/gust and wind direction.

PRESSURE –

|

  • Press this key to view the absolute pressure average of 12 h, 24 h, 48 h and 72 h.
  • Hold this key pressed for 2 seconds to view the absolute and relative pressure.

ALARM|

  • Press this key to view the alarm value of temperature/humidity/ rain rate/rain day/wind.

MAX/MIN|

  • Press this key to view the max/min value of temperature/ humidity/rain rate/rain day/wind/UVI/light/absolute pressure.

LIGHT/SNOOZE|

  • Press this key to adjust the LCD brightness.
  • Hold this key pressed to register a new transmitter.

Notes:

  • Press WIND + and PRESSURE ­ simultaneously to reset the weather station and clear all records. All user settings will return to default.
  • Press TEMP. to skip the RF signal reception.
  • In setting mode, press WIND + or PRESSURE ­ to set the value.
  • Press LIGHT/SNOOZE or wait 30 seconds to exit the setting mode.
Setting Mode

Hold SET pressed for 2 seconds to enter the setting mode. The basic settings can now be performed in following order.
**Beep

** Press WIND + or PRESSURE ­ to select on (beep at every key press) or off (beep off).

**Max/Min Daily

Press SET again. Press WIND + or PRESSURE ­ to activate/deactivate the max/min daily function (default: on + clear at 00:00 every day).
Time/Date

Press SET again to set the time. Press WIND + or PRESSURE ­ to set the values. The setting sequence is: 12/24 h hour minute DD-MM/MM-DD year month day
Pressure


**

  • Absolute vs. Relative Pressure
    Hold PRESSURE ­ pressed to select the absolute or relative pressure.

  • Pressure Graph Rate of Change
    This graphic is shown on the left of the barometric pressure and signifies the difference between the daily average pressure and the 30-day average in hPa.

  • Pressure History
    Press PRESSURE ­ to select the 12 h/24 h/48 h/72 h pressure average.·

  • Relative Pressure Calibration
    Pressure conditions should be compared only at sea-level conditions. To determine the relative pressure for your location, locate an official reporting station near you (the internet is the best source for real-time barometer conditions, such as weather.com or wunderground.com), and set your weather station to match the official reporting station.

**Light

Press SET again to select the light unit (lux, fc, w/m², default: w/m²).
Temperature

Press SET again to select the outdoor temperature unit (°C or °F, default: °C). In normal mode, press TEMP. to view wind chill, heat index and dew point temperature. Hold TEMP. pressed to register a new transmitter.
Note that an out-of-range temperature will be displayed as –.-.
Wind Speed

Press SET again to select the wind speed unit (km/h, mph, knots, m/s, bft, default: km/h). In normal mode, press WIND + to view the wind/gust and wind direction.
Rain

**

Press SET again to select the rainfall unit (in/mm, default: mm). In normal mode, press RAIN to view the rain rate, event, rain day, rain week, rain month and rain total. Hold RAIN pressed to reset the current displayed rain value.
**Moon Phase


**

Press SET again to select the Northern or Southern hemisphere.

Alarm Mode
  1. Alarm Value 1. Press ALARM to display the high alarm.
    graphical user interface, application

  2. Press ALARM again to display the low alarm.
    a clock mounted to the monitor
    Press RAIN to select the display rate or day rain alarm data.
    Press WIND + to display the wind or gust alarm data.
    Press ALARM or LIGHT/SNOOZE to return to normal mode.

Alarm Mode Setting

  1. Hold ALARM pressed to enter the alarm setting mode.

  2. Press WIND + or PRESSURE ­ to activate/deactivate the alerts and adjust the alert values.

  3. Press SET to confirm and move to the next item.

  4. Press ALARM to switch the alarm on or off.
    When the alarm is triggered, the triggering source icon, the icon for the high value and the icon for the low value will be flashing.

  5. Press ALARM or LIGHT/SNOOZE to return to normal mode.

Alarm Setting Sequence
time alarm indoor high temperature indoor low temperature indoor high humidity
indoor low humidity outdoor high temperature outdoor low temperature outdoor high humidity  outdoor low humidity high wind  rain rate high   rain day high

Max/Min Mode
  1. Press MAX/MIN to display the maximum data.

    Press TEMP. to view wind chill, heat index and dew point temperature. Press RAIN to view rain rate, rain day, rain week and rain month maximum.
    Press WIND + to view wind and gust maximum. Hold PRESSURE ­ pressed to view the absolute and relative maximum pressure.

  2. Press MAX/MIN again to display the minimum data.
    a clock mounted to the side
    Press TEMP. to view wind chill and dew point temperature.
    Hold PRESSURE ­ pressed to view the absolute and relative minimum pressure.
    Hold MAX/MIN pressed to reset all maximum or minimum values.

  3. Press MAX/MIN or LIGHT/SNOOZE to return to normal mode.

Calibration
  1. Hold TEMP. and MAX/MIN pressed to enter the calibration mode.
    text
    Press WIND + or PRESSURE ­to set the values.
    Press SET to confirm and move to the next item.
    Press ALARM to reset any adjusted value.

  2. Press LIGHT/SNOOZE to exit the calibration mode.
    The setting sequence is:
    Indoor temperature offset    indoor humidity offset  outdoor temperature offset  outdoor humidity offset    absolute pressure offset wind direction offset    wind speed factor   rain factor

Other Functions

Factory Reset/Memory Clearance

  1. Remove the power by removing the batteries and disconnecting from the mains.
  2. Re-apply the power by connecting the appliance to the mains.
  3. Wait for the appliance to Initialize.
  4. Hold WIND + and PRESSURE ­ pressed simultaneously to reset the weather station and clear all records. All user settings will return to default.
  5. Re-insert the batteries into the appliance.

Registering a New Transmitter
Hold LIGHT/SNOOZE pressed to register a new transmitter.
Backlight
The display will only be permanently backlit when the appliance is powered through the mains. Adjust the backlight intensity with LIGHT/SNOOZE.
When the appliance is powered through batteries, the display backlight will switch off after 15 seconds to reduce power consumption.
Tendency Arrows
These arrows allow you to quickly determine temperature or pressure tendency.

Arrow| | Humidity| Temperature|

Pressure

---|---|---|---|---
| rising| > 3 %| ≥ 1 °C/2 °C| > 1 hPa
| steady| ≤ 3 %| < 1 °C/2 °C| ≤ 1 hPa
| falling| > 3 %| ≥ 1 °C/2 °C| > 1 hPa

Wireless Signal Indicator
This indicator displays reception quality. If no signal is lost, the indicator will display 5 bars; if the signal is lost once, four bars will be displayed.
Weather Forecast
Weather forecast is indicated by weather symbols. Note that the appliance needs at least one month of atmospheric pressure registration to learn the barometric pressure over time.


Note that weather forecasts are just predictions and that errors in predictions are normal.
Snooze
When time alarm has been triggered, the alarm will sound and the alarm icon will flash for 120 seconds. Press LIGHT/SNOOZE to silence the alarm for 10 minutes. The alarm will sound again when that time is up. Press any key except LIGHT/SNOOZE to stop the alarm.

Internet Connection

Please visit the product page on www.velleman.eu and refer to the online manual.

Care and Maintenance

Cleaning

  • Before starting any cleaning or maintenance activities, unplug the appliance from its power source.

  • Wipe all exterior surfaces of the appliance clean with a soft cloth dampened with a soap and water solution. Do not immerse or submerge any part of the appliance in water or any other liquid. Never use solvents or cleaning agents containing petroleum (petrol, kerosene, oil), paint thinner, turpentine, alcohol, or ammonia.
    Maintenance

  • This appliance does not need any maintenance. Do not open exterior casing of the appliance. There are no user-serviceable parts inside. Opening or visible attempts to open or repair the appliance may void any guarantee and/or cause damage to the product or personal injury. Storage

  • Store the appliance and its accessories in its original package in a clean and dry area.

Technical Specifications

Temperature

Indoor range| -10 °C to 60 °C
Outdoor range| -40 °C to 60 °C
Indoor accuracy| –
Outdoor accuracy| +/- 1 °C
Humidity
Indoor range| 10-99 %
Outdoor range| 10-99%
Indoor accuracy| +/-5%
Outdoor accuracy| +/-5%
Wind
Speed range| 0-50 m/s
Speed accuracy| .+/- 1 m/s (v < 5 m/s), +/- 10 % (v > 5 m/s)
Air pressure range| 700-1100 hPa
Measuring interval
Indoor| 60 s
Outdoor| 16 s
Transmission distance| ± 100 (open area)
Dimensions|
Main unit| 188 x 118 x 21 mm
Sensor| 338 x 296 x 214 mm
Weight
Main unit| 240 g
Sensor| 580 g
Power supply main unit
Power adapter (incl)| 5 VDC, 1 A
Battery (not incl.)| 3 x LR03
Power supply sensor
Battery (not incl.)| 2 x LR6
built-in solar panel
Frequency
Weather Station| 868.3 MHz
Wi-Fi| 2412-2472 MHz
FM radio| –
DCF| –
Max. RF power transmission| < 20 mW

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our websitewww.velleman.eu. The information in this manual is subject to change without prior notice.
RED Declaration of Conformity Hereby, Velleman NV declares that the radio equipment type WC224 is in compliance with Directive 2014/53/EU.

Velleman® Service and Quality Warranty
Since its foundation in 1972, Velleman® acquired extensive experience in the electronics world and currently distributes its products in over 85 countries. All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).
General Warranty Conditions Concerning Consumer Products (for
EU):

  • All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
  • Velleman® can decide to replace an article with an equivalent article, or
    to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion.
    You will be delivered a replacing article or a refund at the value of 100%
    of the purchase price in case of a flaw occurred in the first year after the
    date of purchase and delivery, or a replacing article at 50% of the
    purchase price or a refund at the value of 50% of the retail value in case
    of a flaw occurred in the second year after the date of purchase and
    delivery.

Not covered by warranty:

– All direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity…), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits;
– Consumable goods, parts or accessories that are subject to an aging process during normal use, such as batteries (rechargeable, non- rechargeable, built- in or replaceable), lamps, rubber parts, drive belts… (unlimited list);
– Flaws resulting from fire, water damage, lightning, accident, natural disaster, etc.…;
– Flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer’s instructions;
– Damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally);
– Damage resulting from an inappropriate packing and shipping of the article;
– All damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®.

  • Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.
  • Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs.
  • Repairs occurring after warranty expiration are subject to shipping costs.
  • The above conditions are without prejudice to all commercial warranties. The above enumeration is subject to modification according to the article (see article’s manual).

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals