PEREL E305EM6-G Energy Meter User Manual

June 4, 2024
PEREL

PEREL E305EM6-G Energy Meter

PEREL E305EM6-G Energy Meter product-img

Introduction

PEREL E305EM6-G Energy Meter fig 1

To all residents of the European Union
Important environmental information about this product

Disposal

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local  recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities.
Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.

Symbols

  • CE marking
  • Read and undersQtand this manual and all safety signs before using this
  • appliance. Indoor use only.

Safety Instructions

  • This device can be used by children aged from 8 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and user maintenance shall not be made by children without supervision.
  • There are no user-serviceable parts inside the device. Refer to an authorized dealer for service and/or spare parts.
  • Do not immerse the device in any liquid. Keep the main unit away from high heat and fire.
  • Do not disassemble or open the cover under any circumstances. Touching live wires can cause life-threatening electroshocks.
  • Keep this device away from extreme heat.
  • Protect this device from shocks and abuse. Avoid brute force when operating the device.
  • Do not use the device when damage to housing is noticed. Do not attempt to service the device yourself but contact an authorised dealer.
  • Connect this meter to a 230 V~, 50 Hz mains only.
  • Disconnect the device from the mains to clean it or when not in use.
  • Never insert objects into the meter.
  • Do not use a damaged or deformed meter.
  • Do not use with loads exceeding 16 A. Do not connect multiple meters in series.

General Guidelines

  • Refer to the Velleman® Service and Quality Warranty on www.velleman.eu.
  • Protect this device from shocks and abuse. Avoid brute force when operating the device.
  • Familiarise yourself with the functions of the device before actually using it.
  • All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.
  • Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.
  • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
  • Keep this manual for future reference.

Use

  • Plug the meter into a suitable mains outlet, it will switch on automatically.

  • Plug a suitable device (<16A!) into the meter and switch it on.

  • The meter starts to display the line power (W).

  • Press the MODE button multiple times to change the display:PEREL E305EM6-G Energy Meter fig 2
    (line power (W) – consumption (kWh) – total cost – cost/KWh)

  • To set the cost/kWh, press the mode button until COST/KWH is displayed. Press the SET button and use the UP button to change the value of the first digit. Press SET again to move to the next digit.

  • When all 4 digits are set, set the radix point using the UP button. Press SET again to store the value.

  • To clear all data (except line power), press and hold the MODE button for 3 s in KWH or PRICE mode. Note: Line power is measured real-time, hence it will not clear.

Specifications

  • operating voltage …………………………….. 230 V~, 50 Hz
  • max. load ……………………………………….. 16 A, 3600 W
  • min. power display ……………………………………… 0.1 W
  • power measuring accuracy …. ± 1 % or ± 1 W (0-100 W)
  • min. consumption display …………………………. 0.01 kWh
  • consumption accuracy …………………………………..± 1 %
  • consumption range ……………………… 0.00-9999.99 kWh
  • own consumption @ 220 V …………………………. < 0.5 W
  • cost range …………………………………………… 0.00-9999
  • IP rating …….. IP20 (protection against objects > 12 mm)
  • dimensions ………………………………… 55 x 115 x 75 mm
  • weight …………………………………………………… ± 120 g

Use this device with original accessories only. Velleman Group nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman Group nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PEREL User Manuals

Related Manuals