REV. 8/25/23
Warranty
he suppliers of these tools have been designed to give you years of superior
performance. The manufacturer warrants its tools to be free from defects in
material or workmanship for one year from the original date of purchase.
During the one year warranty period, The manufacturer will, at its discretion,
repair or replace components which prove to be defective. The replacement of
complete units due to defective components is not covered under this warranty.
Costs for transportation or related service labor are not covered by this
warranty. Parts and components which have been replaced are warranted only for
the remainder of the original warranty period.
Defects resulting from misuse, abuse, lack of maintenance, unauthorized
modification, chemical incompatibility, or exposure to freezing temperature
conditions are not covered under this warranty. This warranty does not apply
to wear parts and components which require replacement as a result of ordinary
usage.
If you are in need of warranty service, contact your local distributor or the
manufacturer. If the tool must be returned to the manufacturer or an
authorized service center, the purchaser will be responsible for all shipping
charges for the products returned for warranty service. No returned items will
be accepted by the manufacturer without prior authorization by the
manufacturer.
The manufacturer makes no other warranty, either expressed or implied, with
respect to this product. The manufacturer is not liable for any direct,
indirect, special, incidental or consequential damages.
Safety Information
Do not operate the Cordless Sprayer if:
- You are not properly trained and authorized.
- If this unit is not in its proper operating condition.
- If you and the unit are in standing water.
- If you and the unit are in flammable or explosive areas.
- If the user’s manual has not been read.
Before you operate the Cordless Sprayer, check to see that all safety devices
are in place and functioning properly.
While using the Cordless Sprayer:
- Avoid handling the electrical plug with wet hands as stray electrocution may occur.
- Keep the electrical cord away from heated surfaces.
- Report machine damage or faulty operation immediately to your distributor.
- Follow mixing and handling instructions on chemical containers.
- Do not use flammable materials in this tank.
- Do not use solvent based chemicals in this tank.
Servicing of this machine should be performed by your local Distributor.
Please do not remove any of the labels on the back of the sprayer.
Overview
Cordless Sprayer Features
- Spray Gun
- Handle
- Switching
- QD/ Dip Tube/ Cap
- 2.5 Gallon Jug
- Base
- DC- Input
- SOL. Hose
This Package Includes:
|
Cordless Sprayer
---|---
| Car Charger
| Wall Charger
|
Wall Charger
Charging the Battery
First time use – it is important to charge the Cordless Sprayer prior to
operating the unit.
The battery charger is a “SMART” charger. It will charge/recharge the battery
without overcharging.
Plug in the electrical cord to a standard 120-VAC grounded outlet. Plug the
other end of the cord to the charging cord resectable at the side of the unit.
Red light means battery is charging
Green light means battery is fully charged
- For faster charging, make sure the power switch is in the OFF position.
- Charging may take up to several hours.
- It is OK to operate the unit while charging. Battery will charge while unit is in use.
- Please recharge the unit at the end of each day
Before Operation
Fill The Bottle
Disconnect the bottle via the quick disconnect fitting. Lift the bottle up off
of the base. Fill with water and/or cleaning/disinfecting solution.Once
filled, replace the cap with the quick disconnect fitting and return the bottle
to the base.
Re-connect the quick disconnect fitting.
Turn the power switch to the ON position. You will hear the pump begin to run,
as the pump pressure builds up and fills the hose, it will stop.
The pump will run when the trigger on the gun is pulled and stops when the
trigger is released.
Turn the unit OFF when not in use to save the battery’s charge for the next
use.
Storage
Empty the unit at the end of each job, and make sure the bottle is cleaned out
thoroughly. It is important that the bottle and pump are clear of any chemical
solution for any period of time that the Cordless Sprayer is idle. This is
necessary, since some solutions contain d’Limonene or a caustic material,
which tends to deteriorate the pump.
In other cases, some diluted solutions tend to thicken when sitting for a
period of time and may cause an obstruction.
If storing in freezing conditions, please make sure that the unit contains no
water, including in the pump, internal lines, and re-coil hose. Using solvents
and degreaser will void warranty. However, if using, rinse with fresh water
after each use.
Charge the battery daily.
Frequently Asked Questions
PUMP:
Can the pump pressure be adjusted?
The pump pressure is pre-set and not adjustable, however changing the jet size on the lance can accomplish a lower output of fluid. It takes only a few minutes to do this.
The pump turns on and then immediately stops, is this normal?
The pump has a built in pressure switch that senses a stoppage of flow and will shut the pump down. As soon as the trigger of the gun is engaged, the pump will sense pressure release and instantly turn back on.
The pump is still not on.
A – The easiest thing to check is the jet. Take off the jet and make sure it
is clear of debris.
B – The other most likely scenario is the spring on the jet check valve is
tight, not allowing fluid to push past. Using an Allen wrench, turn the check
valve counter clockwise 1/2 turn. Repeat this step until desired result of
flowing when trigger is engaged and non dripping after trigger is disengaged.
Is there an easy way to diagnose if the check valve spring is too tight?
This only works if you have the gun connected through a quick disconnect
fitting.
Disconnect gun, hold open end of hose over bucket/ pail and turn pump on. If
fluid is flowing then refer to previous FAQ (The pump is still not on. A/B)
QUICK DISCONNECTS:
My quick disconnects seem tight.
A – Relieve any pressure in line first. This can be accomplished by squeezing
the trigger. If no fluid comes out refer to FAQ (The pump is still not on. A)
B – Examine quick disconnects for loose or missing ball bearings on the female
QD.
Replace quick disconnect.
C – Bearings look good. Clean fittings and light use of lubricant. Too much
grease or lubricant will attract dirt making them more difficult to use.