VIKING VoIP Phone Auto Dialer, Keypad Entry System Instruction Manual
- June 7, 2024
- VIKING
Table of Contents
- VIKING
- Features
- Applications
- Specifications
- VoIP SIP System Compatibility
- Definitions
- Features Overview
- Installation and Mounting
- PC Requirements
- PC Programming
- Programming Features
- Operation
- Troubleshooting
- Related Products
- Control Relay Contacts Across a Local Area Network
- Related Products
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIKING
VoIP Phone with Auto Dialer, Keypad, and Entry System
Instruction Manual
K-1900-8-IP Series
The K-1900-8-IP Series panel phone can either auto-dial a phone number each time the handset is lifted, be used as a multi-number auto-dialer, or be used as a standard manual dial phone. The K-1900-8-IP Series phones are designed to provide quick and reliable communication for SIP VoIP phone systems with PoE. The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address. The K-1900-8-IP Series phone can dial up to 250 programmable numbers and another 250 rollover numbers.
When a call initiated by the K-1900-8-IP Series phone is answered by an apartment or business tenant, a built-in contact closure may be activated to control an electric gate or door strike. Up to 1,000 keyless entry codes may be programmed, providing tenants with keyless entry. A 26 Bit Wiegand input is provided for adding an optional proximity card reader with capacity to program up to 1,000 card numbers. Keyless entry codes and card numbers can be programmed to only allow access at specific times and/or day of the week. A request for exit (REX) input is included for easy exiting. The K-1900-8-IP Series phone also has automatic event logging allowing you to review the time and date of the call, which door was open/closed, what keyless entry code or proximity card was used, request for exit usage and whether it was an inbound or outbound call.
The K-1900-812L-IP and K-1900812LIPEWP have a 12” long armored cable with internal stainless steel lanyard for additional cable strength.
The K-1900-8-IP-EWP and K-1900812LIPEWP shares all of the features of the K-1900-8-IP and K-1900-812L-IP in addition to Enhanced Weather Protection (EWP) for outdoor installations where the unit is exposed to precipitation or condensation. EWP products are designed to meet IP66 standards and may feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy on-site programming. For more information on EWP, see DOD 859.
Features
- Vandal Resistant Features: 12 gauge 316 stainless steel faceplate with permanent laser etched graphics. Heavy duty metal keypad, hook switch, armored cable and T-10 security Torx drive mounting screws.
- Weather Resistant Features: Marine grade 316 stainless steel faceplate and Torx security screws. Internally sealed keypad. Faceplate gaskets (on EWP models).
- Ring with adjustable volume and cadence
- Hearing aid compatible amplified handset with sealed push button volume control
- Two sets of SPDT 2 Amp relay contacts for door/gate or camera control
- Optional RC-4A for Secure Remote Relay Control, see DOD 582
- SIP compliant (see page 2 for list of compatible IP-PBX phone systems)
- PoE powered (class 2, <6.5 Watts)
- Outbound Proxy, Authentication ID, Peer to Peer, VLAN Tagging
- Network downloadable firmware
- K-1900-812L-IP and K-1900812LIPEWP: 12” armored handset cable
- K-1900-8-IP: 36” armored handset cable
- K-1900-8-IP-EWP: 54” armored handset cable
- Programmable to speed dial up to 250 numbers
- 26 Bit Wiegand input for optional proximity card readers, see DOD 221 and 228
- 26 Bit Wiegand output connect to card reader input of an Access Control System
- Cycles to rollover phone number on busy or no-answer
- Program up to 1,000 keyless entry codes and/or proximity card numbers
- Keyless entry codes and proximity card numbers can be programmed to only allow access at specific times and day of week
- Event logging with time and date stamp
- Optional Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating, see DOD 859
- Remotely programmable
- Extended temperature range (-40°F to 140°F)
- Flush mount with included steel rough-in box, or use an optional VE-5×10 surface mount box (not included, see DOD 424)
- Optional VE-LIGHT kit to illuminate the front panel at night, see DOD 428
- Diagnostics (for testing relays)
Applications
- Apartment Entry Phone
- Commercial Gate Entrance
- Courtesy Assistance Phone
- Customer Service Phone
- Hot-Line Phone
- Door Entry Phone
- Kiosk Phone with up to 250 number speed dialing
- Use with Viking PRX-1 (DOD 221) or PRX-3 (DOD 228) Proximity Card Readers
- Use with Viking LRT-4 Long Range Transmitter (DOD 226)
Specifications
- Power: PoE class 2 (<6.5 Watts)
- Dimensions for K-1900-8-IP and K-1900-812L-IP Models
- Phone only: 5.0” x 10.0” x 4.68” (127mm x 254mm x 119mm)
- Including rough-in box: 5.0” x 10.0” x 5.53” (127mm x 254mm x 141mm)
- Dimensions for K-1900-8-IP-EWP and K-1900812LIPEWP Models
- Phone only: 5.0” x 10.0” x 4.75” (127mm x 254mm x 121mm)
- Including rough-in box: 5.0” x 10.0” x 5.61” (127mm x 254mm x 143mm)
- Shipping Weight for K-1900-8-IP and K-1900-8-IP-EWP: 5.3 lbs (2.4 kg)
- Shipping Weight for K-1900-812L-IP and K-190012L8IPEWP: 5.3 lbs (2.4 kg)
- Operating Temperature: -40°F to 140°F (-40° C to 60° C)
- Humidity – Standard Models: 5% to 95% non-condensing
- Humidity – EWP Models: Up to 100%
- Handset Cable Length on K-1900-812L-IP and K-1900812LIPEWP Models: 12” to 12.7” (31 cm to 33 cm)
- Handset Cable Length on K-1900-8-IP Model: 34” to 37” (86 cm to 94 cm)
- Handset Cable Length on K-1900-8-IP-EWP Model: 52” to 57” (132 cm to 145 cm)
- Audio Codecs: G711u, G711a, G722
- Network Compliance: IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX with auto cross over
- Regulatory Compliance: CE, FCC Part 15 and Canada ICES-003 Class A
- Connections: (1) RJ45 10/100 Base-T, (14) gel-filled butt connectors
VoIP SIP System Compatibility
For compatibility and vendor specific detailed configuration instructions, see the Viking VoIP SIP System Compatibility List, DOD 944. To open and download this PDF file:
Scan the QR code below to open and download the Viking VoIP SIP System Compatibility List
– OR –
- Go to www.vikingelectronics.com and enter 944 in the search box
- Click Application Note (DOD 944) to open and download the PDF
Important: Exclusion from this list means only that compatibility has not been verified, it does not mean incompatibility. If you have questions, please call Viking Electronics at 715-386-8861.
Definitions
Client: A computer or device that makes use of a server. As an example, the client might request a particular file from the server.
DHCP: Dynamic Host Configuration Protocol. In this procedure the network server or router takes note of a client’s MAC address and assigns an IP address to allow the client to communicate with other devices on the network.
DNS Server: A DNS (Domain Name System) server translates domain names (ie: www.vikingelectronics.com) into an IP address.
Ethernet: Ethernet is the most commonly used LAN technology. An Ethernet Local Area Network typically uses twisted pair wires to achieve transmission speeds up to 1Gbps.
Host: A computer or device connected to a network.
Host Name: A host name is a label assigned to a device connected to a computer network that is used to identify the device in various forms of network communication.
Hosts File: A file stored in a computer that lists host names and their corresponding IP addresses with the purpose of mapping addresses to hosts or vice versa.
Internet: A worldwide system of computer networks running on IP protocol which can be accessed by individual computers or networks.
IP: Internet Protocol is the set of communications conventions that govern the way computers communicate on networks and on the Internet.
IP Address: This is the address that uniquely identifies a host on a network.
LAN: Local Area Network. A LAN is a network connecting computers and other devices within an office or building.
Lease: The amount of time a DHCP server reserves an address it has assigned. If the address isn’t used by the host for a period of time, the lease can expire and the address can be assigned to another host.
MAC Address: MAC stands for Media Access Control. A MAC address, also called a hardware address or physical address, is a unique address assigned to a device at the factory. It resides in the device’s memory and is used by routers to send network traffic to the correct IP address. You can find the MAC address of your K-1900-8-IP phone printed on a white label on the top surface of the PoE LAN port.
Router: A device that forwards data from one network to another. In order to send information to the right location, routers look at IP Address, MAC Address and Subnet Mask.
RTP: Real-Time Transport Protocol is an Internet protocol standard that specifies a way for programs to manage the real-time transmission of multimedia data over either unicast or multicast network services.
Server: A computer or device that fulfills requests from a client. This could involve the server sending a particular file requested by the client.
Session Initiation Protocol (SIP): Is a signaling communications protocol, widely used for controlling multimedia communication sessions such as voice and video calls over Internet Protocol (IP) networks. The protocol defines the messages that are sent between endpoints, which govern establishment, termination and other essential elements of a call.
Static IP Address: A static IP Address has been assigned manually and is permanent until it is manually removed. It is not subject to the Lease limitations of a Dynamic IP Address assigned by the DHCP Server. The default static IP Address is: 192.168.154.1
Subnet: A portion of a network that shares a common address component. On TCP/IP networks, subnets are defined as all devices whose IP addresses have the same prefix. For example, all devices with IP addresses that start with 100.100.100. would be part of the same subnet. Dividing a network into subnets is useful for both security and performance reasons. IP networks are divided using a subnet mask.
TCP/IP: Transmission Control Protocol/Internet Protocol is the suite of communications protocols used to connect hosts on the Internet. TCP/IP uses several protocols, the two main ones being TCP and IP. TCP/IP is built into the UNIX operating system and is used by the Internet, making it the de facto standard for transmitting data over networks.
TISP: Telephone Internet Service Provider
WAN: Wide Area Network. A WAN is a network comprising a large geographical area like a state or country. The largest WAN is the Internet.
Wireless Access Point (AP): A device that allows wireless devices to connect to a wired network using Wi-Fi, or related standards. The AP usually connects to a router (via a wired network) as a standalone device, but it can also be an integral component of the router itself.
Wireless Repeater (Wireless Range Extender): takes an existing signal from a wireless router or access point and rebroadcasts it to create a second network. When two or more hosts have to be connected with one another over the IEEE 802.11 protocol and the distance is too long for a direct connection to be established, a wireless repeater is used to bridge the gap.
Features Overview
Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches
Installation and Mounting
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
To install the K-1900-8-IP Series panel phone, attach the phone panel using the provided screws or surface mount using any of Viking’s VE-5×10 Series surface mount boxes (DOD 424). Note: Four extra screws and nuts are provided to fill the unused mounting holes.
Viking’s optional Surface Mount Boxes (model VE-5×10 shown below) are designed to be surface mounted to a wall, post, single gang box or a Viking gooseneck pedestal (model VE-GNP shown below). The K-1900-8-IP Series phone can also be mounted in an optional VE-9×20 Weatherproof Enclosure, not shown (DOD 413).
Note: When mounting a K-1900-8-IP-EWP in an optional VE-9×20 Weatherproof
Enclosure (not shown), the length of the handset cable must be reduced. Use a
3/32” hex key or bit to loosen the set screw in the brass handset cable
retainer. Pull approximately 18 inches of the cable through the panel and
retighten the set screw.
Important: Write down the MAC Address (on the RJ-45 jack) as this may be
needed to identify the unit after installation.
Typical Installation on SIP Based VoIP Phone System
Note: A PoE extender can be used for an additional 100 meters per extender. For longer runs (up to 2 km / 1.2 miles) a ethernet to fiber media converter can be used.
PC Requirements
- IBM compatible personal computer with: Windows 7, 8 or 10
- Adobe Acrobat Reader 8 or higher
- K-1900-8-IP hardware
- Available LAN with PoE (class 2, <6.5 watts)
- Ethernet cable ( CAT5 min.)
- 1 MB minimum free hard drive space for installation
- 16MB of free physical RAM
PC Programming
Download and install the programming software
- Go to www.vikingelectronics.com and enter K-1900-8-IP or K-1900-812L-IP in the search box
- Click K-1900-8-IP or K-1900-812L-IP in the search results
- Scroll down the page to Downloads, click IP Programming Software
- Install the programming software by saving or opening the file and then clicking on setup Viking IP Programming.exe
- Follow the prompts on your screen to complete software installation.
- To start the Viking IP Programming application, click on the Viking IP Programming icon on your desk top. The Main screen will appear, allowing the user to program any K-1900-8-IP Series connected to that LAN.
Note: PC must be connected to the same LAN as the K-1900-8-IP Series.
A. Manually Muting SIP/Network Failure Alarm Beeps (3 beeps repeated
every 30 seconds)
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30 seconds in the handset of the K-1900-8-IP Series indicating a SIP registration failure, failure to receive an echo reply from a pinged gateway or Ethernet connection failure. You can manually disable the beeps by pressing and holding the “ ***** ” button for 5 seconds (2 beeps will then be heard) or by clicking the “Mute Alarm Until Next Failure” tab in the Viking VoIP programming software. The LED will continue to flash allowing you to trouble shoot the failure.
B. Connect / Disconnect
Open the “Viking IP Programming” software on the PC and the start screen shown
below will appear. Any Viking IP phones that are connected to the network will
appear on the list. Simply select the K-1900-8-IP Series on the list and click
on the “Connect” button at the bottom or double click the selected phone. If
the security code of the selected phone is still set to default (845464), the
PC software will not require entering a security code to connect to the phone.
K-1900-8-IP Series have a default name of “VIKING_MK64_Vik02”, so if many
phones are connected to the same network that all have the default name, MAC
addresses must be used to identify each phone.
When finished programming, click on the “Disconnect” button at the bottom.
Closing the program will also automatically disconnect the unit.
C. Configuring the K-1900-8-IP Network Settings
Example 1: On-Premise SIP Phone System (Panasonic TDE 100/200)
Example 2: Cloud Based Service Provider (Voip.ms)
Example 3: Cloud Based Service Provider requiring Outbound Proxy and Authentication ID (Ring Central)
D. Configuring K-1900-8-IP VLAN Settings
E. Manually Resetting the Security Code to Enter Programming
F. Manually Resetting All Network Parameters to Factory Default
*Note: if you do not go back on-hook within 6 seconds, the handset will continue to beep until back on-hook. This indicates an error and network parameters will remain unchanged.
Programming Features
1. Unit Name
Up to a 31 character unit name can be assigned to the K-1900-8-IP Series Phone
being programmed.
2. SIP Server
Enter the IP address or URL of your SIP server or service provider in this
field. The SIP server IP address is limited to 74 characters. Note: If an
alternate SIP server IP address is programmed, the IP address for the SIP
server and alternate SIP server will be limited to 31 characters. Note: If
outbound proxy is not required, enter the SIP server IP address into the
Outbnd Proxy field.
3. Peer to Peer Settings
When set to Peer to Peer mode, a SIP server is not used. The unit should be
programmed with a Static IP Address and Username, a password is not used.
Caller ID can be programmed if needed. Simply call the unit by entering the
programmed “username@192.168…(Static IP address for the unit)”. The static IP
address is normally programmed into a page button on the VoIP telephones.
4. Outbound Proxy
If your SIP provider requires an outbound proxy IP address enter it in the
Outbnd Proxy field. If outbound proxy is not required enter the SIP sever IP
address into the Outbnd Proxy field. Note: If not required, this field must
match your SIP server IP address.
5. Authentication ID
If your SIP provider requires Authentication ID, enter it in the Authentic. ID
field. If Authentication ID is not required, leave this field blank.
6. Register Fails (Re-Resolve or Alternate Server)
When registered to a SIP server in the event that registration is lost you can
program the unit to re-resolve using the current SIP server IP address or
route pages through an alternate SIP server. With Alternate Server selected
enter the IP address of the alternate SIP server in the field next to the
Register Fails drop down box. Note: With an alternate SIP server IP address
programmed, the IP address for the SIP server and alternate SIP server will be
limited to 31 characters.
7. Phone Number Database
Clicking on the “Phone Number Database” button will open a screen allowing you
to program all the Tenants Name’s, Speed Dial Numbers, and Primary and Roll
Over phone numbers. Tenant names are stored locally on the PC and are not
uploaded.
The Speed Dial Number is the 1 to 3 digit (0 – 999) number visitors enter on the K-1900-8-IP Series’s keypad for the unit to call the tenant. 3 seconds after the 1 to 3 digit number is entered, the unit will then dial the Primary Phone Number associated with that Speed Dial Number. If there is no answer or a busy signal is detected, the K-1900-8-IP Series phone will then dial the Roll Over Phone Number.
The Primary Phone Number programmed in Index 0 is the number that is dialed when the handset is lifted and the visitor does not dial any digits on the keypad before the “off hook dial delay” timer has expired ( if “Off Hook AutoDial” is enabled). A second Roll Over Number will be dialed when there is no answer or a busy signal is detected. The K-1900-8-IP Series phone is factory set with no Primary or Roll Over numbers programmed.
Note: Typical Apartment Applications use the tenant’s 1 to 3 digit apartment number as the Speed Dial Number. After the apartment number is entered the unit will then dial the tenant’s phone number.
8. Event Log
The Event Log button is used to open the Event Log screen. The Event Log
screen shows you the time and date of each event, the event type, relay action
(which door/gate was opened or closed), entry code index and phone number
index with tenant name. The Event Log can store up to 4,095 events. Events are
stored in a first in first out format.
When the memory is full, new events will over write the oldest events. The Event log can be saved in one of two file formats: Tab Delimited Text or Comma Separated Variable.
9. Entry Code Database
Clicking on the “Entry Code Database” button will open the Entry Code Database
screen.
The Entry Code Database will then download. The Entry Code Database will allow
you to program the Relay Function, Relay 1 and/or 2, once only (one time use
only), Entry Type (Card, Keyless or both), Keyless Code, Proximity Card #,
Facility Code, Day of week, Time of Day and Tenant Name. Tenant names are
stored locally on the PC and are not uploaded. Note that the same keyless
entry code or card number can be programmed multiple times, as shown in the
example below with the “2222” keyless entry code.
10. Keyless/Card Logging
Keyless Entry Code and Proximity Card logging can be set to Log Errors. With
Log Errors selected, the K-1900-8-IP Series phone will not only log all valid
Keyless Entry Code and Proximity Card entries, but also log any errors,
incorrect codes, or non-valid card reads.
Keyless Entry Code and Proximity Card logging can also be set to Live Logging. With Live logging selected and the K-1900-8-IP Series programming software open and connected to a unit, each Keyless Entry Code entered or Proximity Card read will immediately open the Event Log screen.
11. Security Code
The security code allows the user/installer to program the K-1900-8-IP Series
phone. It is recommended that the factory set security code be changed.
Factory Setting: 845464
Note: The security code must be 6 digits and cannot include a or a #.
12. Access Code
The access code comes into play when a tenant calls the K-1900-8-IP Series
phone and a visitor lifts the handset to answer the call or the K-1900-8-IP
Series phone automatically answers the call (see Inbound Call Mode). It is a 1
to 6 digit code (can not contain “ * ” or “#”) that the tenant must dial
before they are allowed to operate the door strike relays, as extra security
on inbound calls. Once a tenant has entered the correct access code, 2 beeps
are heard and the user can now enter any “Remote Access Operation Commands”
(see page 21). The access code can be disabled if this basic security is not
required. Factory Setting: 123456
13. Wiegand Direction
Wiegand Direction allows you to decide if the 26 bit Wiegand connection will
be used as an input or an output. The default setting for direction is
“Inbound” and this is the correct setting if you intend to connect a card
reader or Wiegand keypad device to the wieght and connections.
When the direction is set to “outbound”, the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system. Unprogrammed keyless entry codes dialed by the user on the keypad are then sent over the Wiegand output. When the user dials “#” plus a entry code that is not programmed in the Entry Code Database, the code dialed by the user is sent over the Weigand output along with the facility code selected. Since Wiegand data limits the entry code to 65535 maximum, “#” plus entry codes higher than 65535 are not sent over the Wiegand output. When the user dials “#” plus a valid keyless entry code that is programmed in the Entry Code Database, the code dialed by the user is not sent over the Wiegand output and the Local / External relay is activated.
14. Select Time Zone
When using date and time logged events or setting the access date and times of
keyless codes or proximity cards in
the Entry Code Database, you must program the unit to your time zone. Example:
You are installing the K-1900-8-IP Series phone in the Central standard time
zone: Select (UTC – 06:00) CST, which is 6 hours behind Coordinated Universal
Time (UTC). Factory Setting: CST
15. Daylight Savings
The Daylight Savings Time programming can be enabled or disabled and can be
programmed to start on any Sunday in March and stopped on any Sunday in
November. Currently, daylight saving time starts on the second Sunday in March
and ends on the first Sunday in November, with the time changes taking place
at 2:00AM local time. Factory Setting: Enabled
16. Relay 1 or 2 Internal / External
With relay 1 and/or 2 set to “Internal” the K-1900-8-IP Series phone will
activate its on board relays for door strike / gate control. Relay 1 and/or 2
should be set to “External” for higher security installations when using a
Viking remote model RC-4A relay controller to activate the door strike / gate
controller (see page 22). Note: With relays set to external the internal on
board relays will also activate at the same time as the external relays.
Factory Setting: Internal
17. Relay Mode
Doorstrike Mode (Factory Setting): When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control. The relay can also be touch tone activated by dialing a “#” plus a valid keyless entry code or by scanning a valid proximity card that has been assigned to that relay.
Outbound Call Mode: When programmed for Outbound Call Mode the relay will activate continuously for the duration of any outbound call from the Entry phone.
Inbound/Outbound Call Mode: When programmed for Inbound/Outbound Call
Mode the relay will activate
continuously for the duration of any inbound or outbound call to or from the
Entry phone. This mode is useful for turning on IR flood lights, for VoIP
phones with cameras, etc.
Doorbell Mode: When programmed for Doorbell Mode the relay will
momentarily activate the relay for the
preprogrammed relay activation time on any outbound call from the Entry phone.
This mode is useful for activating a door chime, etc. When activating door
chimes, a 0.5 – 1 second relay activation time is recommended.
Alarm Mode: When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which can be used to signal an alarm device. This can only be used for internal relay control.
Ring Mode: When programmed for Ring Mode the relay will continuously activate while the ringing extension is called. This mode is useful for activating a Viking model SL-2 strobe light, etc.
Ring Flash Mode: When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off cadence while the ringing extension is called. This mode is useful for activating a Viking LPL-1 Remote Visual Indicator, etc.
18. Relay 1 or 2 Act (Activation) Command
The one or two digit code stored in the Relay Activation Command is the touch
tone command that the person being called must enter on their phone in order
to momentarily activate relay 1 or 2 to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain the characters 0 – 9, 00 –
99, ## or . The code cannot match a relay latching or toggle command (11,
10, 1#, 21, 20, or 2#). The code must be entered while the remote phone is
communicating with the Entry phone. The Entry phone determines which direction
the touch tone is coming from and only responds to touch tones from the called
phone. Factory Setting: Relay 1 – , Relay 2 – *2
19. Relay 1 or 2 Activation Time
The value stored in the Relay 1 or 2 Activation Time is the amount of time
relay 1 or 2 will be energized after a correct momentary touch tone command is
entered, “#” plus a valid keyless entry code or a proximity card was scanned
that is programmed to momentarily activate the relay. This number can range
from 0.5 to 99 seconds. Note: This also affects timing in Doorbell Mode.
Factory Setting: 5 seconds
20. Relay Activation Delay
A relay activation delay of 0.5 – 99 seconds can be programmed in the
K-1900-8-IP Series phone. A relay activation delay is useful in two door
vestibule entrance applications. This allows you to program a delay time from
when relay 1 (outside door) is activated to when relay 2 (inside door) is
activated. The programmed delay time should be set to the average time it
takes a person to walk from the outside door to the inside door.
When a request for exit (REX) is activated, relay 2 will activate first, then
after the programmed delay relay 1 will
activate. Factory Setting: Disabled
21. Relay Latch Commands
When set to “Enabled” the Remote Access Operation Commands to Un-Latch, Latch
or Toggle the relay are enabled. When set to “Disable” the Remote Access
Operation Commands to Un-Latch, Latch or Toggle the relay are disabled.
Disabling the Latch commands can be useful in applications where you want to
eliminate the possibility of in advertently entering a latch command leaving a
gate open/closed, etc. The relays can still be activated with the “Relay
Activation Command” for momentary closures. Factory Setting: Enabled
22. In-Band Audio Call Progress
The In-Band Audio Call Progress Detection can be set to enabled or disabled.
In-Band Audio Call Progress detection should be enabled in applications where
you are making an outbound call through your VoIP phone system and are relying
on In-Band analog audio for ringback or busy detection. Factory Setting :
Enabled.
23. In-Band Audio Detect Sensitivity
The In-Band Audio Detect level (Sensitivity) can be set from 1 – 9, 1 =
minimum setting, 9 = highest setting. Increasing or decreasing the sensitivity
may be required in applications where you are making an outbound call through
your VoIP phone system and are relying on In-Band analog audio detection.
Power cycle unit after changing this setting. Factory Setting : 5
24. Handset Default Volume
The Handset Default Volume can be set from 1 to 4, 1 = lowest volume setting,
4 = highest volume setting. This will be the default volume setting from off
hook but then can be increased or decreased with the handset volume control
button. Setting it to “1, 2, 3, or 4 only” will lock the volume at that
setting for all calls (handset volume control button disabled). Setting it to
“last used” will leave the handset volume set to the last user adjusted volume
setting. Factory Setting: 1
25. Phone Mode
The Phone Mode can be programmed to one of two settings: Auto Dialer or Manual
Dial Phone. When set to Auto Dialer the K-1900-8-IP will auto dial any
preprogrammed phone numbers stored in the Phone Number Database when the
corresponding Speed Dial Number (example: apartment number) is entered on the
unit’s keypad. When set to Manual Dial Phone the unit’s auto dialing features
are disabled and the unit functions as a standard VoIP phone. When the handset
of the K-1900-8-IP is lifted, dial tone is provided and the user can manually
dial the desired number on the keypad. Keyless entry codes can be used in
either mode. Factory Setting: Auto Dialer
26. Call Length Time Out
This feature selects the maximum length of time that calls can be connected.
Programmable in increments of 1 minute up to a maximum of 9 minutes or
disabled. With the call length disabled, the K-1900-8-IP Series phone must
rely on a call ended signal, busy signal, or a touch tone # command to hang-
up. Factory Setting: 3 minutes
Note: Timer starts after call is connected. If call is not answered (and ring
no answer disabled) there is a default 7 minute timer.
27. Inbound Call Mode
The Inbound Call Mode determines how the K-1900-8-IP handles incoming SIP
calls. One option is to generate a ring sound through the handset receiver,
allowing someone to lift the handset to answer the inbound SIP call. The
K-1900-8-IP Series phone can also auto answer the call, to allow remote
control of the doorstrike relays and the ability to listen to transmit audio
from the handset of the phone. The last option is the silent monitor mode,
which allows callers to listen to the transmit audio from the handset of t he
phone at a much higher volume than normal. The “secure” options for auto
answer and silent monitor require the callers to dial the access code in order
to remain connected and listen to the audio from the handset. Factory Setting:
Auto Answer
Disabled – Inbound calls are not allowed.
Auto Answer – Inbound calls are auto answered and the caller hears
transmit audio from the handset at a normal
volume level.
Auto Answer Secure – Inbound calls are auto answered and the caller must
dial the access code in order to listen to transmit audio from the handset
(volume level is still normal).
Ring Low – In the “low” mode the phone will output a ring signal out of
the earpiece in the ring pattern selected in Ring Cadence. The call can then
be answered by taking the handset off hook.
Ring High – In the “High” mode the phone will output a slightly louder,
higher pitched ring signal out of the earpiece in the ring pattern selected in
Ring Cadence. The call can then be answered by taking the handset off hook.
Silent Monitor – Inbound calls are auto answered and the caller hears
transmit audio from the handset at a much
higher volume level.
Silent Monitor Secure – Inbound calls are auto answered and the caller
must dial the access code in order to listen to transmit audio from the
handset (volume level is still at a much higher volume level).
28. Ring Cadence
When “Inbound Call Mode” on the K-1900-8-IP Series phone is set to “Ring Low”
or “Ring High” the Ring cadence can be programmed to one of 4 different
cadences: Factory Setting: Normal Ring
Normal Ring (single ring, 2 seconds on 4 seconds off) factory setting
Double Ring (double ring, 1 second on 0.5 seconds off 1 second on 3.5
seconds off)
Short-Short-Long (triple ring, 0.5 seconds on 0.5 seconds off 0.5 seconds
on 0.5 seconds off 1 second on 3 seconds off)
Short-Long-Short (triple ring, 0.5 seconds on 0.5 seconds off 1 second on
0.5 seconds off 0.5 seconds on 3 seconds off)
29. Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the K-1900-8-IP Series phone will
dial the “Roll Over” speed dial number after the programmed amount of rings.
This can be set from 1 – 9 rings. Factory Setting: 7 (will redial after 7
rings)
30. Dial Next Number on Busy
If enabled and a busy is detected, the K-1900-8-IP Series phone will dial the
“Roll Over” speed dial number.
Factory Setting: Enabled
Notes: If the busy signal is interrupted with a promotional message,
contact your central office to have it removed
31. In Call Dialing Format
The In Call Dialing Format can be set to In-Band DTMF (Touch Tones) or RFC
2833 (Out of Band DTMF Touch Tones). In Call dialing refers to the numbers
dialed after an outbound call has been answered by the distant party. This
would typically be the numbers dialed to steer through automated attendants,
voice mail, etc. If your VoIP phone system does not automatically convert out
of band DTMF to In-Band after the call is answered, set In Call Dialing Format
to “Inband DTMF”. Factory Setting: RFC 2833
32. Off Hook Dialing Delay
The Off Hook Dialing Delay is the length of time a user hears simulated dial
tone after picking up the handset before they are routed to the Primary phone
number in the Phone Number Database Index 0 or hear 3 beeps, depending on the
Off Hook Auto Dial program option.The time is programmable from 0 to 20
seconds. Off Hook Dialing Delay time is needed to allow visitors time after
they come off-hook to then enter the tenant’s apartment number (Speed Dial
Number) or their Keyless Entry Code. Factory Setting: 3 seconds.
34. Mute Current / Next Alarm
A network failure alarm will be indicated by providing 3 beeps every 30
seconds in the handset of the K-1900-8-IP
Series phone. A network failure indicates the unit is not registered to the
SIP server or there is a communication failure with the gateway. The three
beeps can be muted by clicking on “Mute Current / Next Alarm”. The Status LED
will continue to flash to assist troubleshooting. The alarm beeps can also be
permanently disabled. See Permanent Alarm Mute.
35. Permanent Alarm Mute
Selecting “Alarm Tones Disabled” will mute all alarm tones indefinitely. To
re-enable alarm tones select “Alarm Tones Enabled”. Factory Setting: Alarm
Tones Enabled
36. IP Firmware
If new K-1900-8-IP firmware is available, after opening the programming
software a pop window will come up asking you if you would like to update
firmware. An alternative method of updating can be done by clicking the IP
firmware “Update IP” button. You can then browse to the folder that contains
the PIP file for updating the unit’s IP firmware. This method is typically
only used when Viking Technical Support has sent you updated IP firmware.
37. Unit Firmware
If new K-1900-8-IP firmware is available, after opening the programming
software a pop window will come up asking you if you would like to update
firmware. An alternative method of updating can be done by clicking the Unit
firmware “Update Unit” button. You can then browse to the folder that contains
the HEX file for updating the unit’s firmware. This method is typically only
used when Viking Technical Support has sent you updated firmware.
Note: Export your phone settings before updating firmware.
38. Import/Export
The Import/Export feature is useful for backing up all the K-1900-8-IP Series
phone’s programming or for importing programming when installing multiple
units with a majority of the same programming.
39. Clear Phone Settings
Clicking on the “Clear Phone Settings” button in programming will reset all of
the Programming Features back to their factory default settings. Note: This
command will not change or reset your IP settings.
40. Clear IP Settings
Clicking on the “Clear IP Settings” will reset all of the IP settings back to
their factory default settings. This also clears paging Group settings and
Addresses. Note: This will not effect any speaker or paging settings.
41. Diagnostics
The Diagnostics section in the Viking IP Programming can be used to test the
functionality of the two relays, read current relay status, or to display
information on the last card or fob detected by the card reader.
42. REX Input
The K-1900-8-IP has one Request for Exit (REX) trigger input. The REX switch
must have a momentary, normally open contact. When the K-1900-8-IP Series
phone detects a contact closure on the REX trigger input it performs one of
the following actions, based on the Relay Mode settings for each relay (see
section 22):
NOTE: For security reasons the REX input is only enabled when the relay is set to “Internal”.
Relay 1 “Door Strike”, relay 2 other: Relay 1 will be activated for the
programmed Relay 1 Activation Time.
Relay 1 other, relay 2 “Door Strike”: Relay 2 will be activated for the
programmed Relay 2 Activation Time.
Relay 1 “Door Strike”, relay 2 “Door Strike”: If the Relay Activation
Delay is disabled, Relay 2 will be activated for the programmed Relay 2
Activation Time. If Relay Activation Delay is not disabled, Relay 2 will be
activated for the programmed Relay 2 Activation Time, then after the Relay
Activation Delay time has passed, Relay 1 will be activated for the programmed
Relay 1 Activation Time. This is useful in two door vestibule applications
where Relay 1 is used to unlock the outside door, and Relay 2 is used to
unlock the inside door.
Operation
A. Making a Call
The K-1900-8-IP Series phone can be programmed to function as a single number auto dialer, a multi-number dialer or a manual dial phone. The operation for the user depends on which mode it is running.
Single Number Auto Dialer (Phone Mode set to “AutoDialer” and the Off Hook
AutoDial set to “enabled”)
With the Off Hook Dialing Delay set to “No Delay”, when the handset is taken
off-hook, the K-1900-8-IP Series phone will immediately dial the primary phone
number programmed in the Phone Number Database Index 0. If there is no number
programmed in the Phone Number Database Index 0 position, the user will get a
simulated busy signal when the handset is lifted. “#” plus a keyless entry
code can be dialed while the handset is hung up. Proximity cards can be
scanned at any time, even while a call is in progress. The Off Hook Dialing
Delay can be set to a delay of 1 – 20 seconds in this mode, if you wish to
allow users to pick up the handset and dial “#” plus a valid keyless entry
code, instead of being sent to the phone number in the Phone Number Database
Index 0.
Multi-Number Auto Dialer (Phone Mode set to “AutoDialer” and a delay time
selected for Off Hook Dialing Delay)
With the Off Hook Dialing Delay set from 1 – 20 seconds, when the handset is
taken off-hook, the user will hear 1 – 20 seconds of dial tone, allowing them
time to enter the 1-3 digit Speed Dial number (0-999). The unit will then dial
the Primary Phone Number associated with the selected 1-3 digit Speed Dial
Number (0-999). In the event the line is busy or ring-no-answer, the unit can
be programmed to call a second roll over number. If Off Hook AutoDial is
enabled, users that don’t dial digits on the keypad during the provided dial
tone will be automatically sent to the phone number programmed into Phone
Number Database Index 0. If Off Hook AutoDial is disabled, users that don’t
dial digits on the keypad will hear 3 beeps after the provided dial tone. “#”
plus a keyless entry code can be entered while the handset is hung up, or as
the first digits dialed after lifting the handset. Proximity cards can be
scanned at any time, even while a call is in progress. A user that dials “*”
on the keypad will automatically be sent to the phone number programmed into
Phone Number Database Index 0.
Manual Dial Phone (Phone Mode set to ”Manual Dial Phone”)
When the handset is lifted in the Manual Dial Phone mode, the user hears dial tone. Any keypad entries dialed by the user are gathered and sent to the SIP phone system, just like a standard VoIP phone. Proximity cards can be scanned at any time, even while a call is in progress.
In any of the above modes, relay activation commands can be entered or “#” can be dialed (from the remote phone only) to force the phone to hang-up.
After communication is established, enter the 1 or 2 digit relay activation command (factory set to “ * ” for Relay 1 and ”2” for Relay 2) to momentarily activate the entry phone (door strike) relay. Two beeps will be heard confirming that the relay has been activated. If you require the relay to remain on continuously (ie: a truck delivery), enter Touch Tones “11” or “21” to continuously activate relay 1 or relay 2 respectively. A double beep will indicate that the relay is latched on. When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones “10” or “20” to deactivate relay 1 or relay 2 respectively. A single beep will indicate the relay is latched off.
*Note: Relay latch Commands can be disabled in programming.
B. Inbound Calls
How inbound calls are handled is determined by the Inbound Call Mode and these are the available options (see Inbound Call Mode on page 17 for more details):
Disabled – Inbound calls are blocked. Users will get busy or reorder tone
if they attempt to call.
Ring Low or Ring High – Inbound calls generate a ring through the
receiver of the handset using either a low or high pitched ring sound. Someone
must lift the handset to answer the call.
Auto Answer or Auto Answer Secure – The K-1900-8-IP Series phone auto
answers the inbound call and the caller can listen to transmit audio from the
handset at a normal volume level or remotely control the door strike relays if
desired. In the “Secure” mode, the caller must dial the access code in order
to listen to handset audio or control relays.
Silent Monitor or Silent Monitor Secure – The K-1900-8-IP Series phone
auto answers the inbound call and the caller can listen to transmit audio from
the handset at a much louder volume than normal or remotely control the door
strike relays if desired. The louder volume allows the caller to listen to
sounds or conversations occurring around the phone. In the “Secure” mode, the
caller must dial the access code in order to listen to handset audio or
control relays.
C. Remote Access Operation Commands
The following commands can be entered after answering a call from the entry
phone. The commands can also be entered on an inbound call to the entry phone.
After calling into the entry phone and the unit auto answers or someone
answers the call by lifting the handset, one or two beeps will be heard. If
the access code has been disabled (two beeps heard), you can now enter the
Remote Access Operation Commands below. If an Access code has been programmed
(one beep heard), enter the Access code digits. With the correct code entered,
two beeps will be heard and you can now enter the Remote Access Operation
Commands below. The Relay Mode must be set to “Door Strike” to be controlled
by these commands.
* Note: Latching commands must be enabled in programming.
D. Keyless Entry Codes and One Time Use Keyless Entry Codes
Keyless entry codes may be used by the tenants to provide keyless entry. The K-1900-8-IP Series phone can be programmed with a combination of up to 1000* keyless entry codes or one time use keyless entry codes. The keyless entry codes can be programmed to be from 1 to 6 digits in length. Each keyless entry code can be programmed to activate relay 1 and/or 2 in four different relay modes:
Momentary, Latch, Un-Latch and Toggle. To use a keyless entry code the tenant
simply dials “#” followed by the entry code on the K- 1900-8-IP’s keypad.
After the one time use keyless entry code has been used, it is instantly
cleared from the unit’s memory. This is ideal for issuing keyless entry codes
to service personnel, etc.
In the Single and Multi-Number Auto Dialer modes, keyless entry codes can be
dialed while the handset is hung up or when the handset is first lifted, when
some delay has been programmed for Off Hook Dialing Delay.
E. Proximity Cards
Proximity cards can also be used by the tenants to provide keyless entry. The K-1900-8-IP Series phone can be programmed with up to 1000* proximity card numbers. Each proximity card number can be programmed to activate relay 1 and/or 2 in four different relay modes: Momentary, Latch, Un-Latch and Toggle. To use a proximity card, the tenant simply presents a preprogrammed proximity card within range** of the proximity card reader attached to the K-1900-8-IP Series phone. A short beep will be heard from the card reader indicating a card scan. If the card matches a valid preprogrammed card number the relay will be activated and the visitor can now open the door or gate. Proximity cards can be scanned at anytime, even while a call is in progress.
*Note: 1000 is the total number of Keyless Entry Codes and/or Proximity
Card numbers that can be programmed in the Entry Code Database.
**Note: Read range depends on the type of card and card reader being
used.
F. 911 Calls
The K-1900-8-IP Series phone is not intended to be an emergency phone and does not try to automatically handle users that dial “911” after picking up the handset. In the Manual Dial Phone mode, the “911” dialed by the user is passed on to the phone system, so it is up to the SIP phone system or provider to route the call properly. In the Single and Multi-Number Auto Dialer modes, a speed dial of “911” can be programmed with primary and rollover phone numbers, to route the calls appropriately. Some delay must be programmed for Off Hook Dialing Delay, to give the user time to dial the “911” before they are automatically routed to another number or hear 3 beeps.
Troubleshooting
If the unit cannot register with the programmed SIP server, three error beeps will be heard in the handset every 30 seconds until communication is restored. This alerts a potential user of a problem with the device that will prevent a phone call from being made. You may silence the error beeps, per instance, by clicking the “Mute Current / Next Alarm” button in the Viking IP Programming Software (see section B on page 8). The error beeps automatically re-enable once the unit is registered, to alert of any new problems that arise.
Using a Viking Model RC-4A for Secure Remote Relay Control
The front panel of the K-1900-8-IP Series phone is mounted using security Torx screws to help prevent intruders from removing the panel and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to the same LAN as the K-1900-8-IP Series phone. The on board door strike relays would not be used in this case as the KK-1900-8-IP Series phone will send an encrypted message to the RC-4A to activate its relays which control the door strikes/gates.
Up to 4 K-1900-8-IP Series phone’s can communicate with one RC-4A allowing you to securely control four entrances.
When using a RC-4A for remote relay control, the K-1900-8-IP Series phone’s relays should be set to “External” in the PC programming. For more information, see DOD 582 at www.VikingElectronics.com.
Related Products
Surface or Pedestal Mount Viking Products While Maintaining Weather and Vandal Resistance
Control Relay Contacts Across a Local Area Network
The RC-4A Network Enabled Relay Controller provides networked control of four relays via an easy-to-use web interface. The same interface can be used to check the status of four contact closure inputs. Relays can be toggled on or off, or user-programmed timed closures can be activated.
The RC-4A can be configured to work as a remote relay for Viking VoIP series entry phones, controlling door strikes and gates when a remote relay is required for security reasons. It can also be programmed to send an email or text message in response to a change in one or more of the sensor inputs. Two RC-4A’s can be set up so that activity on a sensor input of one unit will automatically send a message across the network to activate one of the relays on the other unit. Two levels of user access permit selected users to have full operational and programming rights while others have operational control but not programming capability.
Related Products
125KHz Proximity Card Reader
The model PRX-1 is a 125KHz proximity card reader and is designed to be mounted directly to a metal door or window frame (mullions), making it ideal for applications requiring an access credential. The proximity card reader transmits data in 26-Bit Wiegand format, making it compatible with any of the Wiegand equipped Viking entry controllers.
The PRX-1 delivers non-contact read ranges up to 6 inches (152 mm), and
operates from 5 to 14 VDC. Physical size is a compact 3.2 x 1.7 x 0.70 inches
(80 x 43 x 17 mm).
Mounting is simplified with horizontal and vertical mounting slots, which
allow the reader to be conveniently adjusted and leveled. To allow both indoor
and outdoor operation the electronics are sealed in tamper resistant epoxy
potting.
Concealing the mounting hardware, the PRX-1 ships with both Black and Ash (Off-White) covers standard. See DOD 221 for more information.
Medium Range 125KHz Proximity Card Reader
The model PRX-3 is a high performance medium range 125KHz proximity card reader. The PRX-3’s compact size yet long read range of up to 16 inches* make it ideal for parking control, gate access, turnstiles, etc. It is designed to be mounted directly to a wall, post, single gang electrical box or use an optional mounting kit for attaching it to a gooseneck pedestal.
Mounting is simplified with horizontal and vertical mounting slots, which allow the reader to be conveniently adjusted and leveled. To increase vandal resistance the chassis is a single piece design with the mounting screws concealed behind a UV stable label.
The proximity card reader transmits data in 26-Bit Wiegand format, making it compatible with any of the Wiegand equipped Viking entry controllers. The PRX-3 is equipped with Enhanced Weather Protection (EWP) for outdoor installations where the unit is exposed to precipitation or condensation. With its sealed connections and fully potted electronics the PRX-3 is designed to meet an IP66 Ingress Protection Rating. For more information see DOD# 228.
125KHz Proximity Cards
The PRX-C and PRX-C-ISO are non-contact security cards that can be presented to the front of a K-1770/75-IP proximity card reader to allow entrance into a secured area. The PRX-C is a clam shell card made made from 0.070” thick plastic to resist bending and folding. A slot is provided at one end to allow a lanyard to be added for creating a “dog tag” style neck strap. The PRX-C-ISO is a thin 0.032” thick flexible “ISO” style proximity card. Much like a credit card,the PRX-C-ISO is perfect for storing in your wallet.
The PRX-FOB is a proximity key ring fob with brass eyelet designed to attach to a key chain or necklace. The PRX-FOB’s compact size is only 1.5” x 1.2” x 0.15” making it one of the smallest available. The cards and fobs are custom pre-programmed. For more information see DOD 198.
Long Range 4 Channel Transmitters and Receivers
Viking’s model LTR-4 Long Range Wireless 4 Channel Radio Transmitters and LRR-4 Long Range 4 Channel Receivers with integrated receive antenna comprise Vikings high frequency, long-range (RFID) identification solution. Intended for security access control applications, the LRT-4’s wireless communication is based upon a secure, digital, antiplayback routine. The LRT-4
Transmitters have four buttons, each corresponding to its own Wiegand output on the LRR-4 Receiver. Each Transmitter includes an integrated red LED, used to indicate both positive button press and battery strength. They are also equipped standard with a 125KHz HID** compatible potted proximity module allowing the Transmitter to also be used as a close range access credential.
The transmitters and receivers operate at 433-MHz allowing a transmission range of up to 400 ft (line of sight). The LRR-4 receiver has an adjustable read range, optional external antenna connector, terminal block with 4 channel Wiegand data output and a transducer and LED to confirm transmitter button press. The LRR-4 has a conformal coated circuit board mounted in a NEMA 4, 4x rated box for use in outdoor applications. See DOD 226 for more information.
Warranty
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT 715-386-8666
Our Technical Support Department is available for assistance Monday through Friday 8:00am to 5:00pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you
have (see serial label).
2. Have your Product Manual in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
- Customer must contact Viking’s Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
- Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
- Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
- RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10
days of purchase):
- Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
- If the Technical Support Product Specialist determines that the equipment is defective based on the customer’s input and troubleshooting, a Return Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
- After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the Viking product using the same R.A. number.
- The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven’t followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.
TWO YEAR LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or
materials, under normal use and service, for a period of two years from the
date of purchase from any authorized Viking distributor. If at any time during
the warranty period, the product is deemed defective or malfunctions, return
the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI.,
54016. Customer must contact Viking’s Technical Support Department at
715-386-8666 to obtain a Return
Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over
voltage, under voltage, accident, misuse, abuse, negligence or any damage
caused by use of the product by the purchaser or others. This warranty does
not cover non-EWP products that have been exposed to wet or corrosive
environments. This warranty
does not cover stainless steel surfaces that have not been properly
maintained.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER
THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES,
BE LIABLE TO PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL,
SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF
THE PRODUCT SOLD HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING’S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.
If trouble is experienced with the K-1900-8-IP phone, for repair or warranty
information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016
715-386-8666
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO
EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the
call. Perform such tests in off-peak hours, such as early morning or late
evenings.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
CANADA
This class A digital apparatus complies with Canadian ICES-003. Cet appareil
numerique de la classe A est conforme a la norme NMB-003 du Canada Product
Support: 715-386-8666
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>