Elitech RC-51H Multi-use Temperature and Humidity User Manual
- June 7, 2024
- Elitech
Table of Contents
Elitech RC-51H Multi-use Temperature
**and Humidity User Manual**
Product Overview
This temperature and humidity data logger is mainly used in the fields or places of medicine, food, life science, flowers , breeding industry, ice chest, container, shady cabinet, medical cabinet, refrigerator, laboratory and greenhouse, etc. RC-51 H is plug and play and It can directly generate the data report, with no need to install data management software. The data can still be read in case battery runs out.
Structure Description
- Transparent cap
- USB port
- LCD screen
- Seal ring
- Button & Bi-color indicator (red and green)
- Sensor
- Product label
LCD screen
- A Battery indicator
- B Mean kinetic temperature
- C Start recording indicator
- D Stop recording indicator
- E Cyclic recording indicator
- F Computer connection indicator
- G Temperature unit(°CRF)
- H Humidity unit or Progress percentage
- I Timing indicator
- J Average value indicator
- K Number of records
- L Combined indicator
Product label
- a Model
- b Firmware version
- C Certification information
- d Barcode
- e Serial number
Picture is for reference only, please take real object as standard.
Technical Specifications
-
Recording Options: Multi-Use
-
Temperature Range: -30 to 70
-
humidity Range: 10%95%
-
Temperature & humidity Accuracy: ±0.5(-20/+40);±1.0(other range) ±3%RH (2520%90%RH)±5%RH(other range)
-
Data Storage Capacity 32,000 readings:
-
Software: PDF /Elitech Log Win or Mac (latest version)
-
Connection Interface: USB 2.0, A-Type
-
Shelf Life/Battery: 2 years1/ER14250 button cell
-
Recording Interval: 15 minutes(standard)
-
Startup Mode: Button or software
-
Stop Mode: Button, software or stop when full
-
Weight: 60g
-
Certifications: EN12830, CE, RoHS
-
Validation Certificate: Hardcopy
-
Report Generation: Automatic PDF report
-
Temperature & 0.1(Temperature)
humidity Resolution 0.1%RHcHimidity -
Password Protection: Optional on request
-
Reprogrammable: With free Elitech Win or MAC software
-
Alarm Configuration: Optional, up to 5 points, Humidity only supports upper and lower limit alarm
-
Dimensions: 131mmx24mmx7mm(LXD)
1.Depending on optimal storage conditions (±15 to +23/45% to 75% RH)
Parameter Instruction
Users can reconfigure the parameters by data management software per actual needs. The the original parameters and
Operating Instructions
This data logger can be stopped by software. Users can stop the logger by clicking the stop button in the data management software.
View data
When the data logger is inserted into the USB port of the computer, the
data report will be created automatically. The red and green indicators flash
in turn when the document is being created, and the LCD screen shows the
progress of PDF Report creation. The red and green indicators light at the
same time immediately after the document is created, then users can view the
data report . The document creation will last for no more than 4 minutes.
(1) Rotate the transparent cap in the direction of the arrow and remove it.
(2) Insert the data logger into the computer and view the data report.
Menu and Status Indicator
Description of the indicator flashing status
Description of the menus
Description of the combined indicators and other status
Note:
- Menu 1 appears only when the corresponding function is selected.
- ” ►” should be in a slate of blinking .•
- The display in the combined indicator area. The same as below.
Replace battery
Report
The First Page
Other Page
- Basic information
- Description of the usage
- Configuration information
- Alarm threshold and related statistics
- Statistical information
- Temperature and humidity graph
- Temperature and humidity data details
- A Document creation time (record stop lime)
- B Alarm (Alarm status as shown in the figure above)
- C Stop mode that has been set.
- D Alarm status of the temperature alarm zone
- E Total times of exceeding the temperature alarm threshold
- F Total time of exceeding the temperature alarm threshold
- G Alarm delay and alarm type
- H Alarm threshold and temperature alarm zones
- I Actual stop mode (different from the item C)
- J Vertical coordinate unit of the data graph
- K Alarm threshold line (corresponding to the item L)
- L Alarm threshold
- M Record data curve (black indicates temperature, deep green indicates humidity)
- N Document name (serial number & description of usage ID)
- O Record time range in the current page
- P Records when date changes (date & temperature and humidity)
- Q Records when the date is not changed (time & temperature and humidity)
Attention: The data above is only used as explanation of the report. Please refer to the actual document for specific configuration and information
What’s included
1 temperature and humidity data logger
1 Er14250 battery
1 user manual
The product should avoid contact with chemicals like unstable chemical solvents or other organic compounds. Particularly, it should not be stored in or exposed to environments that contain high concentration of ketene, acetone, ethanol, isopropanol, toluene and etc. Please do not use the product in the soil for a long time.
Elitech Technology, Inc.
1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035 USA Tel:
(+1)408-844-4070 Sales:
sales@elitechus.com Support:
support@elitechus.com Website:
www.elitechus.com Software Download:
elitechus.com/download/software
Elitech (UK) Limited
2 Chandlers Mews, London, E14 8LA UK Tel:
(+44)203-645-1002 Sales:
sales@elitech.uk.com Support:
service@elitech.uk.com Website:
www.elitech.uk.com Software Download:
elitechonline.co.uk/software
References
- Software – Elitech UK user ico-collapse ic-cross-line-top ic-expand ic-cross-line-top ic-close-circle
- Index of /download/software
- UK.COM
- Elitech UK temperature logger,temperature controller panl - Leader cold chain industry suppliers
- Digital Data Logger & HVAC Tools for Cold Chain – Elitech Technology, Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>