ValuFlo 750 Pump User Guide
- June 7, 2024
- ValuFlo
Table of Contents
INSTALLATION AND SERVICE MANUAL
FILL IN FOR FUTURE REFERENCE:
MODEL: __
SERIAL NUMBER: ___
DATE PURCHASED: __
COMPLETE AND MAIL YOUR WARRANTY REGISTRATION
CARD INCLUDED WITH THIS PRODUCT OR FILE ONLINE AT:
WWW.MDMINC.COM/PUMP-REGISTRATION
TYPE: STRAIGHT CENTRIFUGAL
MOTOR: INDUSTRIAL DUTY 1/8 HP, 1 PHASE, TEFC
1725 RPM (@60HZ), 115 VAC MOTOR
8 FT 3-PRONGED CORD
INLET: 2” FNPT
DISCHARGE: 1-1/2” FNPT
MATERIAL: 40% GLASS-FILLED POLYPROPYLENE WITH NORYL® IMPELLER
HARDWARE: STAINLESS STEEL
OPTIONS: SALTWATER SERVICE
ACCESSORIES: 90 CUBIC INCH STRAINER BASKETS (1.5” & 2”) 500 CUBIC INCH
STRAINER BASKET (2”) SWING CHECK VALVES (1.5”, 2”, 3”)
*MOTORS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY OR SPECIFICATION REQUIREMENTS.
Model | 4200VAF12 |
---|---|
INLET | |
DISCHARGE | |
MAX FLOW (GPH) | 4200 |
MAX HEAD (FEET) | 12′ |
MAX POWER (WATTS) | 166 |
MAX CURRENT (AMPS) | 1.5 |
@(VOLTS) | 115 |
MOTOR HP | 1/8 |
MOTOR ENCLOSURE | TEFC |
IMPELLER | 9 |
Read this manual completely before you install or operate your new pump. This
is an external “out-of-pond” pump.
It is not submersible. Do not allow this pump to become submerged. Never run
dry. Maximum case pressure – 25 PSI.
We congratulate you on your choice of the ValuFlo® 750 centrifugal pump. Its leading-edge design provides you with high output at a minimal operating cost. It is carefully constructed to give you long-term, reliable service. To ensure proper performance, we urge you to carefully follow the instructions in this manual. If you have any questions, please call your supplier for assistance or visit www.mdminc.com/support.
INSTALLATION
Please read carefully. When properly installed, the ValuFlo® 750 will provide dependable, trouble-free service.
-
Do not submerge the unit in water – it is not a submersible pump. Do not allow the pump to become submerged during transient periods, such as heavy rain, run-off, etc.
-
Locate the pump as near the water source as possible. Flooded suction is preferred.
-
The pump is not self-priming. Therefore, if the fluid level is below the pump, a swing check valve must be installed below the water level. The pump and inlet line
must be primed prior to starting up. A strainer basket is recommended for non- flooded installations. -
Mount the motor base to a secure, immobile foundation.
-
Use only plastic fittings on both the inlet and discharge ports. Seal the inlet & discharge fittings with Teflon® pipe dope. These fittings should be self-supported and in neutral alignment with each port (i.e., Fittings must not be forced into port alignment which may cause premature line failure or damage to the pump volute).
-
Never restrict the inlet. Keep both inlet and discharge lines as free of elbows and valves as possible. Always use a pipe of adequate diameter. This will reduce friction losses and maximize output. Never use an inlet line of smaller diameter than the discharge line. Minimize the suction lift.
WARNING: ALWAYS SHUT OFF ELECTRICAL POWER BEFORE INSTALLATION AND / OR
SERVICING THIS PUMP.
ALL ELECTRICAL WIRING SHOULD MEET STATE AND LOCAL ORDINANCES. THE VALUFLO® 750
PUMP MOTOR IS DESIGNED FOR
115 VAC 60HZ POWER ONLY. 230V 50HZ MOTORS ARE AVAILABLE. CONTACT YOUR SUPPLIER
FOR INFORMATION.
ELECTRICAL HOOK-UP
Carefully examine the power cord before use. Do not use this power cord if
there is any visible damage. Do not use this power cord in water or if the
motor or electrical receptacle is in contact with any standing water. This
power cord should only be plugged into a properly installed 115 VAC GFI
receptacle. Always test
cycle a GFI receptacle to determine its condition before use.
PUMP END ASSEMBLY
-
Inspect all pump parts (O-ring, O-ring groove, impeller hub ID, motor shaft, etc.) and clean if necessary.
-
Apply sealant to the bracket bore ID wall and around the seal case – follow sealant manufacturer’s instructions. We recommend using Gasgacinch®. Silicone sealant can also be used.
-
Press the carbon graphite seal into the bracket while taking care not to touch or damage the carbon-graphite face. Never touch or apply pressure to the carbon graphite seal face.
-
Screw the (4) M-Bolts five complete turns into the threaded holes located on the motor face.
-
Mount the bracket to the motor by aligning the keyholes over each bolt head, then rotate clockwise which will position the small keyhole slot under each bolt head. Tighten each bolt with a wrench to secure the bracket to the motor (8-25 inch-pounds force)
-
Carefully, lubricate the seal seat elastomer OD and impeller hub ID with water. Press the seal seat into the impeller hub making certain that the ceramic is in evenly – the sealing surface should be parallel with the impeller hub.
-
Apply clean water to the carbon-graphite and seal seat sealing surfaces. Do not use silicone lubricants or grease.
-
Lock the shaft by placing a screwdriver blade into the shaft slot at the far end of the motor. Thread the impeller onto the motor shaft. Thread until the impeller
securely contacts the shaft shoulder. -
Seat the large O-ring into the bracket O-ring groove.
-
Assemble the volute onto the bracket with (6) P-Bolts (10-24 x 2 ¾” carriage bolts) and (6) flanged locknuts. Tighten in a cross pattern (30 lb. in.).
-
Install the drain plug and O-ring, into the volute drain hole.
-
Before operating the ValuFLo 750, allow a proper cure time for the sealant used in step 2.
NO. | DESCRIPTION | VALUFLO ® P/N |
---|---|---|
1 | DRAIN PLUG | 1000.110 LG |
2 | 0-RING (DRAIN PLUG) | E014B70 |
3 | VOLUTE | 750.070 LG |
4 | LARGE 0-RING | 750.061 |
5 | IMPELLER | 750.059 |
6 | SS SEAL | 750.0414 |
7 | BRACKET | 750.030 LG |
8 | SLINGER | 750.010 |
9 | HARDWARE KIT: (6) P-BOLT, (6) FLANGED LOCK NUT WASHER, (4) M-BOLT | 750.502 |
Note: These part numbers are only for standard models within the ValuFlo® 750 series.
DISASSEMBLY
-
Shut off power to the motor before servicing any pump.
-
Unplug the power cord.
-
Disassemble the volute from the bracket (6) P-Bolts and (6) flanged locknuts. The volute may remain attached to the plumbing to help simplify reinstallation.
-
Lock the shaft by placing a screwdriver blade into the shaft slot at the far end of the motor. Unthread the impeller from the motor shaft.
-
Remove the ceramic seal seat, with a rubber boot, from the impeller hub (if you are replacing the seal).
-
Loosen the (4) M-Bolts attaching the bracket to the motor. Rotate the bracket counterclockwise until the screw heads are located in the large keyhole slots.
Liftoff the bracket from the motor. -
Remove the carbon-graphite seal assembly from the bracket by pressing it out from the motor side of the bracket. Do not pry it out with a screwdriver from the pump cavity side of the bracket (if you are replacing the seal).
MAINTENANCE
Lubrication
Motor – Permanently Lubricated ball bearings – no service required.
Rotary Seal – Requires no lubrication after assembly.
WARNING: EYE PROTECTION IS STRONGLY RECOMMENDED
*The pump must be drained before servicing or if stored below freezing temperatures. Periodic replacement of seals may be required due to normal carbon wear.
SYMPTOM | PROBLEM RESOLUTION |
---|---|
No Flow | InsufficientPrime |
suction piping.
Install check valve.
Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Flow Restriction| Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.
Clean out leaves or other debris from basket strainer (if applicable).
Air leak| Fix air leaks at fittings, connections, strainer basket etc. This
typically occurs on the intake side.
System Incompatibility| Verify hydraulic compatibility: i.e. pump 8. pipe are
sized for the system.
Low Flow| Air leak| Fix air leaks at fittings, connections, strainer basket
etc. This typically occurs on the intake side.
System Incompatibility| Verify hydraulic compatibility: i.e. pump 8. pipe are
sized for the system.
Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Flow Restriction| Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Clean out leaves or other debris from basket strainer (if applicable).
Insufficient Prime| Prime system with water and purge all air from suction
piping.
Cavitation| Verify airtight plumbing on the suction plumbing especially
fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.
Sporadic Operation| Insufficient Power| Verify power supply and connection
from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Poor Ventilation
Ensure adequate airflow over motor to prevent overheating.
Excessive Noise| Cavitation| Verify airtight plumbing on the suction plumbing
especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.
Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage. Some models are dual voltage (115/230).
Flow Restriction| Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.
MDM INCORPORATED
3345 N. Cascade Ave • Colorado Springs, CO • 80907
Phone 719-634-8202 • Fax
866-425-1346
www.mdminc.com •
sales@mdminc.com
Gasgacinch® is a registered trademark of Porter Manufacturing.
Noryl® is a registered trademark of the General Electric Company.
Teflon® is a registered trademark of the Chemours Corporation.
ValuFlo® is a registered trademark of MDM Incorporated.
ValuFlo 750 Installation Manual 2020.indd. Adobe Indesign CC. Updated 3/10/20.
Economy with efficiency.
© MDM INCORPORATED
WWW.MDMINC.COM
References
- Centrifugal Pump Supply & Manufacturer - MDM, Inc.
- Pump Warranty Registration - MDM, Inc.
- Support and FAQ's - MDM, Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>