AIJIA LA-RP4W9 LED Recessed Lighting Slim 4Inch-4Pack Instruction Manual

June 5, 2024
AIJIA

[

aijia-logo](https://manuals.plus/wp-content/uploads/2022/06/aijia-logo.webp)

AIJIA LA-RP4W9 LED Recessed Lighting Slim 4Inch-4Pack

AIJIA-LA-RP4W9-LED-Recessed-Lighting-Slim-4Inch-4Pack-
PRODUCT

INSTALLATION

ALL FIXTURES MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE ELECTRICAL CODES. CONSULT A QUALIFIED ELECTRICIAN TO ENSURE THE CORRECT BRANCH CIRCUIT CONDUCTOR. &. BEFORE STARTING INSTALLATION, SHUT THE LINE FEED POWER OFF USING THE CIRCUIT BREAKER.

Drill holes in the ceiling and prepare supply wires. Install and unshield the line feed wire 12″(25cm} and strip wires 5/8″ (1.6cm}. Bring supply power to junction box through knockout.AIJIA-LA-RP4W9-LED-Recessed-Lighting-Slim-
4Inch-4Pack-FIG-1

MODEL AND HOLE SIZE

  • LA-RP4W9 4-1/8″ (CD 105mm)
  • LA-RP6W12 6-1/8″ (cp 155mm)

Open the lid of the junction box. The white wire is naught wire (AC-N}, the black wire is live wire (AC-L}, and the green wire is earth wire (E}. Though the wiring terminal, connect them to the corresponding wire.

AIJIA-LA-RP4W9-LED-Recessed-Lighting-Slim-4Inch-4Pack-
FIG-2Route junction box through cut- out and connect recessed LED panel to the junction box with the quick connector.

Compress the springs and push the fixture in the opening. It is easier to do one spring at a time.

WARNING & CAUTION

  • THIS RECESSED LED LIGHT IS FOR DAMP LOCATION USE. DO NOT CONNECT MULTIPLE FIXTURES TO ONE DRIVER. CAUTION – RISK OF FIRE. RISK OF SHOCK. DISCONNECT POWER BEFORE SERVICING.
  • TYPE IC
  • INHERENTLY PROTECTED
  • ACCESS ABOVE CEILING REQUIRED
  • THE BLINKING LIGHT OF THIS THERMALLY PROTECTED LUMINAIRE MAY INDICATE

OVERHEATING

  • MIN 90 ° C SUPPLY CONDUCTORS
  • CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR NEC CLASS 1 WIRING ONLY