Intelligent Security System
HOME FORCE Wireless
Intelligent Security System USER MANUAL
2017- 11- 10
13:55
2
2
3
4
Disarm CMS fault Zone Normal
AKWK1
Please read the instruction manual thoroughly before installing and retain for
future reference.
P/N:20181113B02
User manual
Brief
Thank you for purchasing the HOME FORCE system,we hope our products can bring
convenience and protection.The HOME FORCE system uses the most advanced
digital sensing and control technology.The HOME FORCE products can connect to
mobile phone APP and platform through accurate and simple WiFi connection
mode, with remote control and wireless alarm mode to push notification.
User manual
Table Of Contents
Chapter I Product Introduction
1
Chapter II Installation and Connection
3
2.1 Installation
3
2.2 Phone card inserted and removed
4
Chapter III Key description and Basic operation
5
3.1 Key description
5
3.2 Basic operation
6
3.3 LCD icon
7
3.4 System Arm and Disarm
8
3.5 Alarm procedure
9
Chapter IV Voice Alarm Receiving And GSM Control
10
4.1 Remote phone control
10
4.2 Alarm receiving phone operation
10
4.3 GSM control via SMS
11
Chapter V User Settings
12
5.1 Set User Password
12
5.2 Set Voice Phone
12
5.3 WiFi config
12
Chapter VI System Setting
17
6.1 Set password
17
6.2 WiFi
18
6.3 Set Network
18
6.3.1 DHCP
19
6.3.2 Host IP
19
6.3.3 Network gateway
19
6.3.4 Subnet mask
20
6.3.5 Preferred DNS
20
6.3.6 Standby DNS
20
6.3.7 WEB port
21
User manual
6.4 Set CMS
21
6.4.1 Phone CMS Enable
21
6.4.2 CMS Phone No. 1
21
6.4.3 CMS Phone No. 2
22
6.4.4 CMS user Number
22
6.4.5 CMS Dialing Times
22
6.4.6 Internet CMS Enable
23
6.4.7 Sever IP
23
6.4.8 Sever Port
23
6.4.9 Sever Account
23
6.4.10 Sever Password
24
6.4.11 Sever Heartbeat
24
6.5 Set Voice Phone
25
6.5.1 Set voice phone number
25
6.5.2 Dialing times
25
6.5.3 APP Server IP
26
6.6 System options
26
6.6.1 Entry Delay
26
6.6.2 Exit Delay
27
6.6.3 Siren Time
27
6.6.4 Sensor loss
28
6.6.5 AC off Delay Time
28
6.6.6 Comm Test
29
6.6.7 Arm/Disarm Tone
29
6.6.8 Arm/Disarm Report
29
6.6.9 Force Arming
30
6.6.10 Door Open Check
30
6.6.11 Sensor Tamper Check
31
6.6.12 Alarm Times
31
6.6.13 Emergency Siren Type
31
6.7 Learning Wireless Devices
32
6.7.1 Wireless Remote
32
6.7.2 Wireless Sensor
33
6.7.3 Wireless Siren
34
User manual
6.8 Zone Management
35
6.9 Set Alarm Alert
36
6.10 Time
39
6.10.1 Auto time
39
6.10.2 Daylingt-saving time
39
6.10.3 Time 12h/24h
40
6.10.4 Time zone
40
6.10.5 Time
40
6.10.6 Timing Arm/Disarm
41
6.11 Restart
42
6.11.1 Restart
42
6.11.2 Delete logs
42
6.11.3 Factory default
43
6.12 Display
43
6.13 RFID
43
6.14 Others
44
6.14.1 Recording
44
6.14.2 Play
45
6.14.3 PGM
45
6.14.4 Chime Music
45
6.15 Double Knock Zones
46
6.16 About
46
Chapter VII Technical Specification
47
Chapter VIII Maintenance
48
Chapter IX Limitation of the Products
48
User manual
Chapter I Product Introduction
1. Alarm Mode: With Internet network and GSM network alarm,GSM network with
GPRS function,remote arm and disarm panel through CMS or SMS,CID protocol,SMS
notification,the priority of Internet Network and GSM Network is Optional. 2.
With a new color-screen, full-touch buttons, LCD graphic display steps,working
status,alarm process easy and intuitive. 3. The full english voice prompting
operation: all local or remote operation,alarm information,event log view. 4.
The screen brightness can be set: the operating brightness and standby
brightness can be set, and power saving can be used. 5.GSM-hook and voice
telephone with intercom function. 6. Sleep mode: in sleep mode status,all the
lights,LCD backlight,voice and prompt tone are disabled. 7. Alarm panel under
idle status is equivalent to a cellphone,you can call through the GSM network
for balance inquiries. 8. 8 groups associated zone,can effectively reduce
false alarm or for other functions. 9. Remote Phone operation: dialing by
telephone offsite,after password verification,you can arm,disarm,listen-in
premise,system status query and electrical switches controls and other
operations. 10. Voice Alarm: When panel alarm,it will automatically dial the
preset user phone numbers to report alarm information then you can remote
control the panel after enter user passwords. 11. 32 wireless zones,each
wireless zone can automatically learn the codes or be coded manually via the
keyboard and web operation. 12. Enable enroll total 8 wireless remotes,16
electronic switches,1 wireless doorbell and unlimited for quantity of one way
wireless siren,16 RFID tags. 13. 4 CMS phone No., 4 private voice phone No..
14. Status Inspection Functions: enable record and inquiry 512 alarm event
messages.Like the time when happens anti-tamper alarm,detector alarm,tel-line
off, arm,disarm,system setting,battery low voltage ect.And also can inquiry
the zone number and alarm type.
1
User manual
15. Timing Arm/Disarm: 4 sets of timing arm and disarm time. 16. Zone
Programmable: factory preset for each zone type. Users can modify all the zone
type according to the actual needs . 17. Clock: The built-in automatic
calendar clock can be set in accordance with local time and can be
automatically timed. There is a summer time setting, which turns on when set.
18. Password Access Management: the panel has one administrator password 16
user password, The administrator password primarily for system administrators
to set up the alarm system; The user passwords for users in the day-to-day use
such arm/ disarm, remote operation. The administrator password, user password
can be freely modified. 19. For CMS networking alarm, depending on the number
of users, the user can set four user codes(account number). 20. Zone type
identification:After an alarm is triggered, the alarm zone number displayed on
the Color screen of the panel, also can send the detailed report to CMS which
includes alarm locations and zone types. 21. Alarm mode: stand-alone single-
family use by the ordinary telephone alarm; it can also be connected to the
Internet with the alarm center by the computer alarm.Alarm center
automatically recognize and compatible with ordinary telephone alarm. 22. CMS
communications test: The panel will send a message to CMS at the pre-set time
interval to inspect the communication if normal. 23. Siren options:The built-
in siren can be used with the company’s wireless high-end siren. All tweeter
siren can be closed or opened when the alarm is selected according to the
user’s needs. 24. The voice speaker volume adjustment: total 7 level,adjust
the volume by a panel arrow keys. 25. Wireless repeater function: can extend
the distance between the detector and the panel by adding a wireless repeater
of our company. 26. The wireless detector low battery prompted:Detectors will
send status report to the panel every 1-3 hours, the corresponding zone number
and the battery voltage symbol will be displayed on the LCD screen and also
will report to CMS.
2
User manual
Chapter II Installation and Connection
2.1 Installation
2.1.1 AKWK1 installation
The AKWK1 kit is supplied with a wall mounting bracket (Fig 2-1). An optional
desk mount base is available AKWK1BK (Fig 2-2).
After the power supply is turned on the stand, the main power contact point
and the top of the stand should be placed for charging. (Figure 2-3)
Fig. 2-1
Fig. 2-2
Power contact point
Tamper switch
2.1.2 AKWK1 installation Installation steps:
Fig. 2-3
Thimble
A.Secure the bracket to the wall with screws.
3
B.Place the panel on the bracket. Screw holes
C. Screw in from bottom to top
User manual
2.2 Ensure the panel is not near any metal objects as this can affect the
wireless signal range. 2.3 Make sure to place the panel within the wireless
range of all wireless accessories and Devices.
2.2 Phone card inserted and removed
Mobile phone network providers tested are 02, Vodafone, EE. A SIM card adaptor
may be required. Insert: Pay attention to insert the mobile phone card ensure
the panel is turned off. As shown in the figure below, insert the side of the
magnetic disk toward the front of the main unit and the corner of the main
unit. Insert the mobile phone card completely into the main unit to
automatically lock it (It will not pop up automatically). When there is a
lock, there will be a “click” sound, and the phone card can be inserted and
then turned on to register the network. Take out: Align the phone card and
push it in and out again. The phone card will pop up automatically. When it
pops up, there will be a “beep” sound, and then it can be pulled out. Note: TF
card is used by the manufacturer for program upgrade. Users are not allowed to
insert it. If you need help, please consult your dealer.
Front
Temperature sensing probe
4
User manual Chapter III Key description and Basic operation
3.1 Key description
2017- 11-10
13:55
2
2
3
4
Disarm CMS fault Zone Normal
Arm(Full Arm) Home Arm(Part Arm) Disarm RFID Card Up key Down key,System
status/zone status/event log inquiry key Return key, volume reduction Confirm
key,volume plus
5
User manual
Press 3 seconds to trigger fire alarm
Press 3 seconds for medical help
Press 3 seconds for SOS Press 3 seconds and enter user code to enable or
disable delay zone door bell This machine does not support this function
Press 3 seconds to enter or exit sleep mode
Press 3 seconds then enter user code to enable or disable electrical power
switch Press 3 seconds then enter user code to bypass zones or activate zones
Press 3 seconds then enter user code to proceed normal testing,siren testing
and walk testing Press 0 for 3 seconds to make phone call through GSM, the
talk time up to approximately 240 seconds Set/Select down key
Confirm/Open options key
Sleep mode: all LED indicators,backlight,voice,remind tone will be disabled
under sleep mode,The panel will exit sleep mode automatically when users enter
system setting or when alarm occurs. Bypass zone: bypassed zones means zones
disabled.Bypass zones will be canceled when users disarm systems under home
armed or armed status. Communication test: To test the communication between
the panel and the CMS if normal. Siren test: To test if siren working normal.
Walk test: To test if the detectors are working normally with the panel and
alarm.
3.2 Basic operation
Factory default Administrator password: 012345 16 User passwords,No.01 factory
default is 1234.No.02-16 of the user password is blank and can not enter the
user setting until user set the password. Password No.01 is the Manager code,
02-16 are users, only password 01 can enter the user settings.
6
User manual
Disarm: User password [1234]+Disarm key Home Arm(Part Arm): Home arm key
Arm(Full Arm): Arm key Event Log: Press Down key to choose event log +
Shutdown: AC power off firstly, in disarm status, Press # key for 3s, enter
1234# command. Enter System Setting: Press key for 3s, enter admin password
012345# command. Enter User Setting: Press key for 3s, enter 1st user
password 1234# command. Forget Password:Shutdown firstly, within 60s of AC
power on, press * key for 3s, enter 000000# command to reset. Notice: Only
under disarm status of panel, enter system settings and user settings.
3.3 LCD icon
2 0 1 7 – 11 – 1 0
13:55
2
2
3
4
Disarm CMS fault Zone Normal
Icon
Meaning GSM signal strength
Icon
Meaning WiFi
Enable Internet CMS
APP control
Power supply Arm(Full Arm) Home arm(Part Arm)
Integral battery level System disarm Temperature
Fault prompt
Zone status
1.System fault display: Icon” “indicates that the function has failed. Eg.WiFi
disconnected,will display icon”
“, if WiFi connected, will display” “.
” “This is fault icon. if there are two faults, it will display” 2 “.
2.Zone fault display: When the zone fails, Zone status corner icon shows the
number of zone faults,the text below the icon shows the fault function.When the fault
is removed, the icon shows “zone normal”.
The details of the faults can be queried by entering the user settings.
When panel alarm and user disarm,the screen still shows zone alarm,please disarm
again ,and the screen shows the zone normal.
7
User manual
3.4 System Arm and Disarm
ARM(Full Arm)
2017 – 11- 10 13:55
2
2
3
4
Disarm CMS fault Zone Normal
~Di~Di~
DISARM
2017 -11-10 13:55
2
2
3
4
Disarm CMS fault Zone Normal
~Di~Di~
2 0 1 7 – 11 – 1 0
13:5Es5it
De
l
a
y3
2
4
10 2
Disarm CMS fault Zone Normal
Press the arm key on remote or the keypad, then you hear system armed, please exit the protected area there will be tone to confirm the system is armed successfully.
2017- 11-10
13:55
2
3
2
4
Disarm CMS fault Zone Normal
Press the disarm key on the remote or enter your user password on the keypad,then you will hear a tone and a voice command “system disarm”, then you have disarmed successfully.
HOME ARM(Part Arm)
2017 – 11- 10 13:55
2
2
3
4
Disarm CMS fault Zone Normal
~Di~Di~
SOS
2017 -11-10 13:55
2
2
3
4
Disarm CMS fault Zone Normal
~Di~Di~
2017- 11- 10
13:55
2
3
2
4
Home CMS fault Zone Normal
Press the key for home arm(Part Arm) on the remote or HOME key on the keypad,then you will hear ‘system home arm’ and it display home arm icon on the LCD screen.
2017- 11-10
13Z:o5n5e
ala
r
m3
2
4
Manuyal Emergency
2
Disarm CMS fault Zone Normal
Press the panic button on remote, or press 3 key on panel for 3 seconds,it will trigger to alarm.
The codes of arm/disarm via different ways: Arm/disarm via remote controllers: 1-8 remotes—–#40-47 Arm/disarm via user codes: 1-16 user codes—-#01-16 Arm/disarm via phone call: 1-4 user phone number —-#50-59 Arm/disarm via CMS:
60 Arm/disarm via auto timer or key zone: #80-81 Arm/disarm via RFID Card:
20-39 Arm/disarm via WEB Page: #70 Unknown control: #90
8
User manual
3.5 Alarm procedure
Telephone Mobile APP
Telephone Cell phone Cell phone
1st
2nd
3rd
4th
3.The panel will dial 1-4 telephone numbers as preset.If more than 4 numbers, the panel will start will second telephone number, then3,4…
Internet CMS
Wireless
SMS
Alarm situation found, start to send message
2 0 1 7 – 11- 1 0 13:55
2
2
3
4
Disarm CMS fault Zone Normal
1.The detector activated send alarm information to
alarming center.
Wireless
Phone CMS 2.The panel use Ademco Contact ID to send alarm information to
alarming center. If the panel got confirmation from center, then alarm
successfully.Otherwise,the panel will repeat alarm.The alarm information will
be display and resolve by the alarm center computer software.At the same time,
the panel can also send alarm information to the CMS through
Alarm software the Internet, managed and displayed by the management software
.
9
User manual
Chapter IV Voice Alarm Receiving And GSM Control
4.1 Remote phone control
User make phone call to the GSM No.of the alarm control panel.Directly connect
to the alarm control panel,according to the voice prompt to enter the user
password as below photo.
1
Dial the GSM No. Of the alarm control panel.
2 0 1 7 – 11- 1 0 13:55
2
2
3
4
Disarm CMS fault Zone Normal
2
The alarm control panel auto off-hook
3
Please enter password
4
11 12 13 14
Then enter user password according to voice prompt (the factory default user
password is 1234)
5 Press 1 to arm system Press 2 to disarm system Press 3 to stay arm Press 4 to check system status Press 5 to appliance switch control Press 8 to control PGM Press 9 to talk back Press 0 to disconnect
4.2 Alarm receiving phone operation
When alarm,the panel will dial the preset voice phone number,when the user
pick up the call,they will hear the voice prompting as below, if not press 1
to cancel the alarm or press 4 to disarm the system,after off-hook,the panel
will call other preset voice phone numbers.
2017 – 11- 10 13:55
2
2
3
4
Disarm CMS fault Zone Normal
1
The alarm control panel dial preset voice phone as soon as alarm occurs.
2
The user pick up the phone.
3
Play the recorded voice message first. Press 1 to cancel alarm Press 2 to
check alarm event Press 3 to arm system Press 4 to disarm system Press 5 to
stay arm Press 6 to enable siren Press 7 to listen in Press 9 to talk back
Press 0 to disconnect
10
User manual
4.3 GSM control via SMS
Arm Command Disarm Command Home Arm Command Status Checking command Enable
appliance switch command
Disable appliance switch command
PWD1234 # ARM #PWD1234 #DISARM #PWD1234 # HOME
PWD1234 # CHECK #PWD1234 # SWITCH OPEN XX(XX=01-16 on behalf of appliance
switch number) #PWD1234 # SWITCH CLOSE XX(XX=01-1 6 on behalf of appliance switch number)
PWD = the user Password
Note: 1, the factory default user code is 1234, when arm successfully, SMS
auto replyarm successfully’, if the password is correct, the command is not correct, SMS will reply
operation failure’, if the password is not correct,
no SMS reply. 2, ‘FOR Enable/disable the appliance switch #PWD1234 # SWITCH
OPEN XX(01-16) XX is for electric switch serial number from 01-16, there is
space between OPEN’ and
XX’
This panel does not support PGM.
11
User manual Chapter V User Settings
Press [*] for 3 seconds
+ 1 2 3 4+#
5.1 Set User Password
Password Phone WiFi config APP QR Code
For example: set No.2 use password as 5678
Press [*] for 3 seconds
1 2 3 4+ # +
Password
User1
++
Add New Password
User2 User2
5 6 7 8+
S e t t i n g s a v e d !
Note: Up to16 user passwords,corresponding password No. From 01 to 16,Only No.1 password is the Manager and this password can only enter the user settings.
5.2 Set Voice Phone( refer to 6.4)
5.3 WiFi config
The Challenger APP “HOME FORCE” can be downloaded from the Play or APP Store.
12
User manual
For new users, please click “user registration”.
Fig. 5-1
Fig. 5-2
Click the app to enter login interface .
User name: (EMAIL)
Password: (set as you like)
After setting, please enter the code and click “Register”.
After the registration is successful, the interface will automatically
There are two methods the alarm panel can be learnt to the APP, if you are having difficulty with method 1, please use method 2.
PLEASE NOTE: The panel can only be learnt and connected to a single user account. The APP can be installed on multiple devices but the same login account details must be used. If the panel has already been registered then the device will need to be deleted fromthe APP so it can be re-learnt.
Method 1:iPhone
Step 1.Press and hold the
for 3 seconds,
voice prompt: please enter password,
input 1 2 3 4 + # +
enter smart config interface to enable the smart phone
configuration mode.
SmartConfig
Connect the phone to the WiFi hotspot,enter the correct WiFi name and password, click the phone configuration button to start the configuration.
13
Left Right
Exit
Save
User manual
Step 2: iPhone
Select+
Select WiFi-GSM
Select WiFi Config
Select your WiFi network & password press Config
18088866@163.COM
When the alarm panel displays “WiFi Configuration successful”
On alarm panel, re-enter the code & select`AP QR code’and scan with phone
030648D6D
030648D6D
Select WiFiConfiguration successful
Method 1:Android
Step 1.Press and hold the
for 3 seconds,
voice prompt: please enter password,
input 1 2 3 4 + # +
enter smart config interface to enable the smart phone
configuration mode.
SmartConfig
Connect the phone to the WiFi hotspot,enter the correct WiFi name and password, click the phone configuration button to start the configuration.
When scanned and confirmed
Left Right
Exit
Save
14
User manual
SelectSettings
Select WiFi-settings
SelectSmart Settings WiFi
Select Colour Screen
18088866@163.COM
When the alarm panel displays “WiFi Configuration successful”
On alarm panel, re-enter the code &select `AP QR code’ and scan with phone
030648D6D
030648D6D
Enter password and press Start Configuration
When scanned and confirmed
Method 2:AP setting WiFi
Step 1: Log in to the registered account, enter the device add interface
WiFi/GSM alarm System, select “AP setting WiFi”.( Fig. 5-11) Step 2: Enter the
available WiFi name and password in the hotspot setting WiFi
interface(Fig.5-12), click to start configuration, and the pop-up window
prompts the operation steps.(Fig.5-13)
Meiantech
Fig. 5-11
15
Fig. 5-12
Fig. 5-13
User manual
Step 3: Press and hold the host For more than 3 seconds,
the voice prompts “Please enter the password”.
Input 1 2 3 4 + # +
Enter AP mode;
Enter AP mode
AP nameWIFI_PANEL AP passwordB996DAD0 APP accountadmin APP password012345 Server IP192.168.1.1 Server port18034
Step 4: Open the phone WiFi settings, select the hotspot name and enter the hotspot password to connect; switch to the phone configuration interface and click “Start Configuration”( Fig. 5-11,5-12,5-13).
Fig. 5-11
Fig. 5-12
Fig. 5-13
After the configuration is completed, the host color screen is displayed to indicate whether the WiFi is normal. Click “OK” to enter the scanning QR code to add the host interface. Please refer to Method 1 in step 4.
16
User manual Chapter VI System Parameters Settings
Press[*]for 3 secondsvoice prompt
Password
WiFi
“please enter Administrator password”
+0 1 2 3 4 5+#
CMS
Phone
Network Options
Wireless
Zone
Alert
SmartHome
Time
Restart
Display
RFID
Others
6.1 Set password
CrossZone
About
Press[*]for 3 secondsvoice prompt”please enter password”
+ 0 1 2 3 4 5 +#+
the following operations can be performed
Set admin password
Set user 1 password
Add new password
Set password
Set password
Set password
Administrator
User 1
User 2
Administrator
Administrator ** LCD display
+6 digit new password+
User 1 User 1 ****
LCD display
+6 digit new password+
User 2 User 2
LCD display 6 digit new password+
Settings saved!
Settings saved!
Settings saved!
LCD display
LCD display
LCD display
Note: Password setting is included user password and administrator password.
user password mainly to disarm the system, Administrator password is the sole
password to alter the parameters of the system.
17
User manual
2.Administrator password is 6 digit, user password is 4 digit, can set 16 user
password, corresponding password No. from 01 to 16, but No.02-16 password can
not enter user setting.
For example: Change admin password to 888888
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
+*
+ 8 8 8 8 8 8+
Settings saved!
After the setting is completed,
LCD display
the screen will automatically return to the upper interface
Note:1. If incorrect operation occurs,please press back key to back previous
menu.
2.The factory default of admin password is 012345, user password is 1234, if
you have modified the password, please refer to the new password.
6.2 WiFi
Press []for 3 seconds voice prompt”please enter password”
+ 0 1 2 3 4 5 +#+
WiFi connection method is described in “5.3 WiFi config”.
6.3 Set Network
Press []for 3 seconds voice prompt”please enter password”
+0 1 2 3 4 5+#+
Press 3 times
Note: Can alter the panel,gateway, subnet mask and DNS when DHCP is disabled.
SmartConfig Enter AP mode Exit AP mode
DHCP IP Gateway Subnet Mask Preferred DNS Alternate DNS Web Port
18
User manual
6.3.1 DHCP
Enabled DHCP means using DHCP server to assign IP address, subnet mask and default gateway automatically.(default is enabled) For example: Disabled DHCP
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 3 times
+ 0+
Settings saved!
LCD display
0 is disabled,1 is enabled After the setting is completed, the screen will
automatically return to the upper interface.
6.3.2 Panel IP The default DHCP function is enabledplease disabled DHCP when
you wish to manually set the panel IP Address. User need to set up the network
parameters according to the actual network environment . when there are more
panels in the same network, the IP address of panels must be different.
Setting the IP address, if it is not enough 3 digits, please fill in the 0
before the digits,for example “192.168.1.81”, need to enter “192168001081”
from keypad. after setting IP address, then exit system setting and auto
restart to make the setting in valid.Note: when DHCP is enabled, this setting
is invalid.
For example: Set IP as 192.168.3.82
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 3 times
+ 1 9 2 1 6 8 0 0 3 0 8 2+
After the setting is completed, the screen will automatically return to the
upper interface.
Settings saved!
LCD display
6.3.3 Network gateway User can set network gateway according to the local actual conditions, for example:set gateway as 192.168.3.1
19
User manual
Press[*]for 3 seconds
Enter password+ 0 1 2 3 4 5 + # +
Press 3 times
- Press 2 times
+ 1 9 2 1 6 8 0 0 3 0 0 1+
Settings saved!
After the setting is completed, the screen will automatically return to the upper interface.
LCD display
6.3.4 Subnet mask For example: set Subnetmaks as 255.255.255.240
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 3 times
- Press 3 times
+ 2 5 5 2 5 5 2 5 5 2 4 0+
Settings saved!
After the setting is completed, the screen will automatically return to the upper interface.
LCD display
6.3.5 Preferred DNS For example: set preferred DNS as 202.096.128.086
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 3 times
- Press 4 times
+ 2 0 2 0 9 6 1 2 8 0 8 6+
After the setting is completed, the screen will automatically return to the
upper interface
Settings saved!
LCD display
6.3.6 Standby DNS Please refer to the above operation method.
20
User manual
6.3.7 WEB port Please refer to the above operation method.
6.4 Set CMS
Press [*] for 3 seconds, voice prompt”Please enter password”
+0 1 2 3 4 5+#+
Press 4 times
Phone CMS Enable CMS Phone No. 1 CMS Phone No. 2 CMS user Number CMS Dialing Times Internet CMS Enable Sever IP Sever Port Sever Account Sever Password Sever Heartbeat
6.4.1 Phone CMS Enable(the default is enabled) For example: make phone alarm platform disabled
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+0+
Settings saved!
LCD display
0 is disabled,1 is enabled, after the setting is completed, the screen will
automatically return to the upper interface
6.4.2 CMS Phone No. 1
When alarm is triggered, the panel will dial CMS telephone number to inform
central monitor server, CMS telephone number max.17 digits. For example: Set
CMS telephone number as 80012345
21
User manual
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+ 8 0 0 1 2 3 4 5+
Settings saved!
LCD display
After the setting is completed, the screen will automatically return to the
upper interface
6.4.3 CMS Phone No. 2 Please refer to 6.3.2
6.4.4 CMS user Number The user No. is the identity code of the user at the
alarm center.
For example: set user No. as 1701
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+ 1 7 0 1+
Settings saved!
Press 3 times
LCD display
After the setting is completed, the screen will automatically return to the upper interface.
6.4.5 CMS Dialing Times When alarm happens, the device will dial the CMS telephone no.1 and no.2 the factory default is 5 times, if the call is still not answered after 5 times, it will stop to dial out . for example: set dial times as 8.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+ 0 8+
Settings saved!
Press 4 times
LCD display
Dial times can be set as 1-15, high perch fill 0 when less than 2 bits.
After the setting is completed, the screen
will automatically return to the upper interface.
22
User manual
6.4.6 Internet CMS Enable(the default is disabled) For example: Enable network platform.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
- Press 5 times
+ 1+
Settings saved!
LCD display
0 is disabled, 1 is enabled, after the setting is completed, the screen will automatically return to the upper interface.
6.4.7 Server IP For example: set server IP as 192.168.1.66
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
- Press 6 times
+ 1 9 2 1 6 8 0 0 1 0 6 6+
After the setting is completed, the screen will automatically return to the
upper interface.
Settings saved!
LCD display
6.4.8 Server Port For example: set server port as 5679default is 7974
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+ 0 5 6 7 9+
Settings saved!
Press 7 times
After the setting is completed, the screen
LCD display
will automatically return to the upper interface.
6.4.9 Server Account For example: set server register ID as 02001010.
23
User manual
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+0 2 0 0 1 0 1 0 +
Press 8 times
Register ID can be set up to 8 digits at most, After the setting is completed, the screen will automatically return to the upper interface.
Settings saved!
LCD display
6.4.10 Server Password For example: set server register password as 12345678
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
- Press 9 times
+1 2 3 4 5 6 7 8+
Register password can be set up to 8 digits at most,
After the setting is completed, the screen will automatically return to the
upper interface.
Settings saved!
LCD display
6.4.11 Server Heartbeat
Heartbeat time means the time interval that the device sending info to
platform.every interval heartbeat time, the device will send heartbeat info to
the platform. if the platform can not receive several heartbeat info, this
device will be considered as offline, and record this offline in the platform
data. For example: set heartbeat time as 40s(heartbeat time is 1-255s,default
is 25s)
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 4 times
+ 0 3 0+
Settings saved!
Press 10 times
LCD display
Heartbeat time can be set from 1-255, high perch fill 0 when less than 3 bits
After the setting is completed, the screen
will automatically return to the upper interface.
24
User manual
6.5 Set Voice Phone
Press[*]for 3 seconds, voice prompt”please enter password”
+0 1 2 3 4 5+#+
Press 5 times
Voice Phone 1 Voice Phone 2 Voice Phone 3 Voice Phone 4 Dialing times APP Server IP APP Server port APP Account APP Password APP QR code
6.5.1 Set voice phone number When alarm happens, the device will dial user’s phone no., it can set 4 voice phone no. each phone number can be set up to 17 digits at most. For example: set voice phone 3 as 12345678
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 5 times
+ 1 2 3 4 5 6 7 8+
Press 2 times
Press * can delete the last digit,
After the setting is completed, the screen
will automatically return to the upper interface.
Settings saved!
LCD display
6.5.2 Dialing times Default is 5 times. For example: set voice phone dial times as 6.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 5 times
+ 0 6+
Settings saved!
Press 4 times
LCD display
The dial times can be set as 1-15, high perch fill 0 when less than 2 bits.
After the setting is completed, the screen will automatically return to the upper interface.
25
User manual
6.5.3 APP Server IP Set App serverdefault is 119.147.144.090 For example: set App server IP as 114.184.162.081
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 5 times
- Press 5 times
+ 1 1 4 1 8 4 1 6 2 0 8 1+
Settings saved!
After the setting is completed, the screen will automatically return to the upper interface.
LCD display
APP Server Port: default is 18034 APP Accountsame as panel’s IDfor
example1AB7113E. APP PasswordNetwork forwarding platform APP login
password,default
is 12345678, user can change it, can enter 16 digits. APP QR codeScan QR code
to add login account.
6.6 System options
Press[*]for 3 seconds, voice prompt “please enter password”
+0 1 2 3 4 5+#+
Press 6 times
Entry Delay Exit Delay Siren Time Sensor loss AC off Delay Time Comm Test Arm/Disarm Tone Arm/Disarm Report Force Arming Door Open Check Sensor Tamper Check Alarm Times Emergency Siren Type
6.6.1 Entry Delay
When trigger delay zone, the panel will delay to alarm( default is 10s) For
example: set entry delay time as 20s
26
User manual
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
+ + 0 2 0+
Settings saved!
LCD display
The entry delay time can be set from 1-255, if an error has been made press or
if you wish to move back a digit then press the UP button to move back to the
previous digit.
Note: the entry delay is only valid for the delay zone, other types of zone
without delay.
6.6.2 Exit Delay After arming the system, the user has enough time to exit the protection area.( exit delay time is 1-255s, default is 10s) For example: set exit delay time as 20s.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
+ 0 2 0+
Settings saved!
LCD display
The entry delay time can be set from 1-255, if an error has been made press or if you
wish to move back a digit then press the UP button
to move back to the
previous digit.
6.6.3 Siren Time Siren time is 1-30 minutes, the default is 5 minutes.
For example: set siren time as 10 minutes.
NOTE: The maximum duration the Siren can be set to in the UK is 20 minutes as
not to exceed noise UK pollution.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
+1 0+
Settings saved!
- Press 2 times
LCD display
The siren time can be set from 1-30, if an error has been made press or if you wish
to move back a digit then press the UP button
to move back to the previous
digit.
27
User manual
6.6.4 Sensor loss In the set time period, the panel will detect if it has received the status report or alarm info from the detector, if not received, this detector will be regarded as loss, recommended loss inspection time no less than 6 hours.( default is 0, disabled) For example: set detector loss inspection time as 8 hours.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
+0 8+
Settings saved!
- Press 3 times
LCD display
The detector loss inspection time can be set from 0-99,
if an error has been made press or if you wish to move back a digit then press the
UP button
to move back to the previous digit.
6.6.5 AC off Delay time It means the time when AC off, the device will delay
to report to CMS.
0- 99 minutes, default is 30 minutes
For example: set AC off inspection time as 15 minutes.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
- Press 4 times
+1 5+
Settings saved!
LCD display
The AC off inspection time can be set from 0-99, high perch fill 0 when less
than 2 bits. after the setting is completed, the screen will automatically
return to the upper interface
Note: 1. this function mainly use for the area with unstable power 2. when AC recovery in delay time, it will not send report to CMS.
28
User manual
6.6.6 Comm Test Within this period, the alarm panel will send a test signal to the CMS to check if communication is working. (Factory default is 0, disable) E.g. Set communication test period as 3h.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
- Press 5 times
+0 0 3 +
Settings saved!
LCD display
The communication test interval time can be set from 0-999,
6.6.7 Arm/Disarm Tone When user arm/disarm through remote fob or remote access, the arm/disarm tone can be enabled or disabled. For example: set arm/disarm tone is enabled.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
- Press 6 times
+1+
Settings saved!
LCD display
0 is disabled,1 is enabled,after the setting is completed, the screen will
automatically return to the upper interface.
6.6.8 Arm/Disarm Report If enable to set force arm, when there is zone trouble, the system can be armed and report the trouble zone s bypass message to CMS. If disable the force arm, the system can not be armed(factory default is disable force arm) Example: enable force arm.
29
User manual
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
+1+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will
automatically return to the upper interface.
- Press 7 times
6.6.9 Force Arming if enabled to set force arm, when there is zone trouble, the system can be armed and omits the zone in trouble and the trouble zone bypass message to CMS. If disable the force arm, the system can not be armed(factory default is disable force arm) Example: enable force arm.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
- Press 8 times
+1+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will
automatically return to the upper interface.
6.6.10 Door Open Check If set the alarm panel show zone trouble on LCD screen or not when separate the magnetic strip from transmitter. (Factory default disable the inspection) Example: enable the magnetic contact inspection
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
- Press 9 times
+1+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will
automatically return to the upper interface.
30
User manual
6.6.11 Sensor Tamper Check If enabled this checks when the detector tamper has been operated and will cause an alarm. If disabled will not activate the alarm. (Factory default disabled)
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
- Press 10 times
+ 0+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will automatically return to the upper interface.
6.6.12 Alarm Times(Auto Re-Arm) After an alarm activation the panel will automatically re-arm itself when the external siren timer has expired. If this option is enabled the panel will only re-arm the zone 3 times.(Default Unlimited)
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
++
Press 11 times
Settings saved!
LCD display
switch selection,After the setting is completed,
the screen will automatically return to the upper interface.
6.6.13 Emergency Siren Type( the default setting is mute) This option allows if the emergency (SOS) alarm has been activated then the siren can be set to Mute, Pulse or Continuous
31
User manual
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 6 times
Settings saved!
Press 12 times
LCD display
switch selection,After the setting is completed,
the screen will automatically return to the upper interface.
6.7 Learning Wireless Devices
Press * for 3 seconds, voice prompting “enter password”.
Wireless Remote Wireless Sensor
+0 1 2 3 4 5+#+
Press 7 times
Wireless Switch Wireless Siren
Wireless doorbell
Note: Pressing the * will tab to the next option in each menu screen.
6.7.1 Wireless Remote Press[*]for 3 seconds
+ 0 1 2 3 4 5+# +
Press 7 times
Add manually
Enter 9 digits address code+
After that, the following
operations can be carried out:
Settings saved!
LCD display
Auto
please trigger wireless device
Cancel
LCD display
Delete remote
Select 9 digits address code to delete+
Note:”×××××××××”in LCD display is 9 digits address code of the remote.
Press arm key
XXXXXXXXX Save Continue
LCD display
- Confirm to delete? Confirm Cancel
LCD display -
32
Remote control interface
User manual
Support 8 remote control at max. E.g: Add address code 112005123 of the remote automatically.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 7 times
112005123
Setting is saved!
Save Continue
Press arm key
LCD display
LCD display
After the setting is completed, the screen will automatically return to the upper interface
Wireless Sensor Interface
6.7.2 Wireless Sensor
Press[*]for 3 seconds
+ 0 1 2 3 4 5+# +
Press 7 times
After that, the following operations can be carried out:
Add manually
Enter 9 digits address code+
Settings saved!
LCD display
Auto
please trigger wireless device
Cancel
LCD display
Trigger the device
XXXXXXXXX
Save Continue LCD display
Delete device
Select 9 digits address code to delete+
Note:”×××××××××”in LCD display is 9 digits address code of the detector.
Confirm to delete? Confirm Cancel
LCD display
Support 32 wireless detectors at max, the zone number will be the order of detectors added. E.g.: Delete the address code (118006123) of the detectors
33
User manual
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 7 times
Use
to select address +
code118006123
Confirm to delete? +
Settings saved!
Confirm Cancel
LCD display
After the setting is completed, the screen will automatically return to the upper interface
6.7.3 Wireless Siren Support one dual-way siren, countless one-way siren. Please Note: The AUW3 is a dual-way siren.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 7 times
Please make wireless siren
under coding status, then
press
key to start coding.
The alarm panel enter code status
- Press 3 times
One Way Siren
LCD display
Two Way Siren
LCD display
If it is a two-way wireless alarm, the screen will display its address code.
After the setting is completed, the screen will automatically return to the
upper interface NoteWhen tamper alarm from the dual-way siren, the alarm panel
will show zone 41 alarm.Only one dual-way wireless siren can be added, but no
limits for one way wireless siren.If need to add both dual way and one way
siren, please add dual way siren at last.
34
User manual
6.8 Zone Management
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
can set zone type
Press 8 times
Zone 1-32 is reserved wireless devices , Zone 32-40 is for wired device(This
panel does not support). User can set zone type, zone alarm siren type and
chime function.
Instruction: * is downward selection, # is open option from LCD screen operations.
Zone Type
The type of zone attributuion is as below
disable zone >delay zone
12h/Alarm zone
Part Arm zone >emergency zone
24 hours zone
fire zone
key zone(This panel does not support)
A.Zone attribution is the alarm type of the zone display on the alarm panel’s LCD screen when the zone is triggered. When set the zone attribution as 0 is to disable the zone. The alarm panel will not make alarm when this zone has been activated. B.Part Arm zone only trigger alarm when the panel is aremed in Home (Part Arm). C.Delay and perimeter zone trigger alarm when the zone is triggered in armed or Home (Part Arm) arm status. D.Emergency zone, 24 hours zone, fire zone will trigger alarm when system are in any status. E.This panel does not support PGM.
Set zone siren type User can set three type: Continuous, pulse, Mute (factory default is Continuous)
Chime Function
When the detector as delay zone, once it is triggered, the alarm panel will
sound “dingdong” or “welcome”, optional. Factory default is disabled. Factory
default:
Zone
Zone Type Siren type
Chime
1~2
Entry/Exit Continuous
Disabled
3~32
Burglar
Continuous
Disabled
33~40
Disabled
Continuous
Disabled
35
User manual
E.g.: set zone 31 as 12/h Alarm zone
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 8 times
-
Press 5 times
+#
Select key zone +
Settings saved!
LCD display
Press mobile, according to # open selection,After the setting
is completed, the screen will automatically return to the upper interface.
6.9 Set Alarm Alert
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
Press 9 times
Press # to select alarm type, press # again to enable/disable alert path.
:enable :disable Note: This machine does not support the email function.
Factory default:
Alarm Alert Type
Delay Perimeter Interior Emergency 24 Hour Fire Panic Tamper
CMS
Factory Default Voice Phone SMS
36
User manual
Alarm Alert Type
System Away System Disarm System Stay System low battery AC loss AC Restore
Alarm Cancel Sensor Low Battery Sensor bat Recovery RF lost Programming
Changed Arm Failed Periodic Test Report Zone Bypass System Bat Restore
Communication Trouble Zone Bypass Cancel Communication Restore Loop Open/Short
Loop Restore Bell Troubl Bell Restore Duress Entry/Exit Recovery Perimeter
Recovery
37
CMS
Factory Default Voice Phone SMS
User manual
Alarm Alert Type
Burglary Recovery Panic Recovery 24 Hour Recovery Fire Recovery Emergency
Recovery Tamper Recovery RF Loss Recovery
CMS
Factory Default Voice Phone SMS
Duress password: 1 + 1 2 3 4 +
user password
When you enter the duress password,you will trigger an duress alarm.If enter
duress password When the system is under arm status,keypad will display system
is disarmed,stop siren but send alarm info and alarm call. (pls set the CMS
phone # and follow me phone #)
Example,A arm the system,B enter the area and trigger alarm,B threaten A
disarm the system.A enter the duress password.The alarm panel will show disarm
status but will send alarm info can call. E.g:Set the 24 Hour Recovery to only
turn on voice phones.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 9 times
+#
Select 24 Hour +
Recovery
+
+#
Settings saved!
LCD display
Press to move the selection, press # to enable/disenable the selection,
After setting, the screen will automatically return to the previous interface.
38
User manual
6.10 Time
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
Press 11 times
6.10.1 Auto time(default is open) For example: Set automatic timing to close
Auto time Daylingt-saving time 24-hour system Time zone Time Timing Arm/Disarm 1 Timing Arm/Disarm 2 Timing Arm/Disarm 3 Timing Arm/Disarm 4
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 11 times
+ 0+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will
automatically return to the upper interface.
6.10.2 Daylingt-saving time(The default is to shut down) Summer Time is set aside by an hour at 2 Am on the first Sunday of middle April. Change 2Am to 3 Am. At 2 o’clock in the morning on the first Sunday in mid-September, The hour will be set aside for one hour, that is, changed from 2 Am to 1Am, and the summer time ends. For example: Set Summer Time active.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 11 times
+ 1+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will
automatically return to the upper interface.
39
User manual
6.10.3 Time 12h/24h(The default is to open) Example: Set time-zone as London time-zone GMT
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 11 times
- Press 2 times
+ 0+
Settings saved!
LCD display
0 is disable, 1 is enable.After the setting is completed, the screen will
automatically return to the upper interface.
6.10. 4 Time zone(default set is Beijing time GMT+8:00) Example: Set time-zone as London time-zone GMT
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 11 times
- Press 3 times
+#
Use
to select GMT in +
the time zone setting bar.
After the setting is completed, the screen will automatically return to the upper interface.
Settings saved!
LCD display
6.10. 5 Time Example Set the time to 15:30 05 on 1 Dec, 2018 .
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 11 times
- Press 4 times
+ 1 8 1 2 0 1 1 5 3 0 0 5+
Settings saved!
After the setting is completed, the screen will automatically return to the upper interface.
LCD display
Note: If you turn on automatic calibration, this setting is invalid
40
User manual
6.10. 6 Timing Arm/Disarm There are four options to automatically arm and disarm the alarm system per day if required (i.e. Arm at 7:58 disarm at 22.05)
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 11 times
- Press 5 times
+ 0 7 5 8 2 4 0 3+
Settings saved!
For downward selection,After the setting
LCD display
is completed, the screen will automatically return to the upper interface.
41
User manual
6.11 Restart
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
Restart Delete logs
Press 12 times
Factory default
6.11. 1 Restart
For example: restart the system.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 12 times
Confirm to restart +
Confirm
Cancel
LCD display
The alarm panel will restart after setting.
6.11. 2 Delete logs
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 12 times
Confirm?
Confirm
Cancel
LCD display
Settings saved!
LCD display
After the setting is completed, the screen will automatically return to the upper interface.
42
User manual
6.11. 3 Factory default
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 12 times
- Press 2 times
factory default +
Confirm Cancel
LCD display
After the setting is completed, the screen will automatically return to the
upper interface. Note:After Restore to factory default, the panel will clear
all the parameter settings, all detectors, remote control, etc. Please re-code
and re-learn accessories to the alarm panel and re-set other parameters ,
otherwise it will not work properly.
6.12 Display
+0 1 2 3 4 5+#+
Press 13 times
Press Press
to Increase the brightness to Reduce the brightness
Operating brightness Standby brightness
6.13 RFID
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
to enter RFID setting.
Press 14 times
43
User manual
Example: Add the RFID and set it with disarm function.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 14 times
Keep the RFID tag near + the sensor area
Options: Disarm Home Disarm SMS Home SMS Disarm-call phone 1
Settings saved!
LCD display
After the setting is completed, the screen will automatically return to the upper interface.
Note: 1. Pls preset the message text on WEB MENU for the two options [disarm and send sms ][ home arm and send sms] 2. You can choose to manual enter the RFID card # to add the RFID card.
6.14 Others
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
Press 15 times
Recording Play PGM Chime Music
6.14.1 Recording
20seconds time to record alarm message. This alarm message will be hear when
you take the alarm phone call from the alarm panel.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 15 times
+#
Start record after hear beep sound. The alarm message will play once after finish recording.
44
User manual
6.14.2 Play
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 15 times
+#
play the alarm message
6.14.3 PGM This panel does not support this function.
6.14.4 Chime Music
Two tones optional : “ringing tone” and “Welcome”. (Default welcome) For
example: set the door open tone as “ringing tone”
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 15 times
- Press 3 times
++
Settings saved!
LCD display
After the setting is completed, the screen will automatically return to the
upper interface.
45
User manual
6.15 Double Knock(Cross Zones)
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
enter related zone setting
Press 16 times
Trigger zone 1 or zone 2 only will not trigger alarm. If zone 1 and 2 are
triggered at the same time or with 120s of each other then a alarm
condition will occur.
Example: Set zone 5 and zone 9 as pair # 4 related zone, related time
is 120secs.
Press[*]for 3 seconds
Enter password + 0 1 2 3 4 5 + # +
Press 16 times
- Press 3 times
+ 0 5+ 0 9 + 1 2 0 +
zone1
zone2
related time , enter 1-255secs
After the setting is completed, the screen will automatically return to the upper interface.
NOTE: Can set 8 pairs related zone.
Settings saved!
LCD display
6.16 About
Press * for 3 seconds, voice prompting “enter password”.
+0 1 2 3 4 5+#+
check system version
Press 17 times
46
User manual
Chapter VII Technical Specification
General information
Power supply: 5V/2000mA Built in rechargeable battery:3.7V/1500mAh(Lithium ion
battery) (it will have low battery indication when battery voltage lower than
3.7V Disabled working voltage:3.5V System static current: <300mA System
alarming current: <500mA Frequency:868MHz Signal transmit distance: 50 meters
(open area) Dimensions:(AKWK1 with wall mount bracket LWH)208147.119.6mm
The method of alarming dial: Internet IP, GSM or GPRS Communication protocol
with CMS: Ademco Contact ID DTMF dial frequency variation:<1.5% Recording
time:20s
WiFi features
Standard: 802.11 b/g/n Built-in Tensilica L106 ultra-low-power 32-bit micro
MCU supporting RTOS Built-in TCP/IP protocol stack WiFi @ 2.4GHz, Supports
WPA/WPA2 Security Mode Supports Smart Config features (including Android and
iOS devices)
Physical performance.
Operation temperature range: 0-45(32-120) Storage temperature range:
-20-60(-4-140) Relative humidity: 85% at 30(86) Color: See real
47
User manual Chapter VIII Maintenance
10.1 Regular Test
Design of components of the system is to reduce maintenance cost, but still it
is suggested that periodical check must be carried out.
10.2 The Cleanliness of Control Main Machine
To clean the panel, this should be done with a soft damp cloth should be used,
do not use any chemicals or abrasives.
Chapter IX Limitation of the Products
Due to our policy of continuous improvement we reserve the right to change
specification without prior notice. Errors and omissions excepted. These
instructions have been carefully checked prior to publication. However, no
responsibility can be accepted by Challenger for any misinterpretation of
these instructions.