Yale Tubular Lockset Lever Installation Guide

June 7, 2024
Yale

Yale Tubular Lockset Lever Installation Guide
Yale Tubular Lockset Lever

Select Proper Backset

For use on doors 1-3/8″ to 1-3/4″ (35mm – 45mm)
Backset is distance from door edge to center of hole on door face.

  • Backset 2-3/8″ or 2-3/4″ (60mm – 70mm)
    Backset

  •  Latch Tail

To adjust backset from 2-3/8″ to 2-3/4″
Pull latch tail.
Pull latch tail

To adjust backset from 2-3/4″ to 2-3/8″
Push latch tail.
Push latch tail

Template

Template

CAUTION: If printed from website print 1:1 scale. Measure dimensions for accuracy before use.

Mark Door

  1. Fold and apply template to high edge of door bevel and mark center of door edge as indicated on template at desired height from floor; approximately 38″ (965mm).
    Mark Door Inductions

  2. Mark center hole on door face through guide on template for either 2-3/8″ (60mm) or 2-3/4″ (70mm) backset.
    Mark Door Inductions

Drill Holes

  1. Drill Drill 2-1/8″ (54mm) hole through door face as marked for lockset.

Note: Drill holes from both sides to prevent splitting.

  1. Drill 1″ (25mm) hole in center of door edge through to 2-1/8″ (54mm) hole for latch.
    Drill Holes Inductions

Install Latch

  • Insert latch in hole keeping it parallel to face of door.
    Mark outline and remove latch.
    Installing Latch

  • Screw Driver Chisel 1/8″ (3.2mm) deep or until latch face is flush with door edge.

  • Drill Insert latch in hole keeping it parallel to face of door.
    Mark two (2) fastener holes, remove latch and drill pilot holes with 1/16″ (1.6mm) drill bit.
    Using provided screws, install latch.
    Installing Latch

Install Strike

  • Mark template for strike opening from edge of jamb. Move 1/4″ (6mm) toward door stop to locate centerline for screws and 1″ (25mm) hole. Make certain strike is at same height as latch.

  • Screw Driver Bore 1″ (25mm) hole 1/2″ (13mm) minimum deep into door jamb on centerline of screws.
    Installing Strike Inductions

  • Drill Match screw holes on strike with centerline on jamb. Outline outside edges of strike. Mortise 1/16″ (1.6mm) deep.
    Using provided screws, install strike. If strike box is required, mount under strike as shown.
    Installing Strike Inductions

Install Exterior Lever

Insert lever with spindle into latch. Make certain that stems are positioned correctly though latch holes.
Press flush against door.

Installing Exterior Lever

Install Interior Lever

Screw Driver Turn interior lever so that assembly and rose can be placed on spindle. The interior lever must engage exterior lever connect bar.
Plush flush against door.
Insert screws through holes and tighten.

Installing Interior Lever

Yale Locks and Hardware

Product Support Tel 1-855-213-5841www.yalehome.com

Yale® and Yale Edge Series® are registered trademarks of Assa Abloy Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only.
© Copyright 2018. All rights reserved. Reproduction in whole or in part without the express written permission of Assa Abloy Residential Group is prohibited.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals