Erba Hobby-compressor Instruction Manual

June 7, 2024
erba

Erba Hobby-compressor Instruction Manual

Erba compressor

SAFETY INSTRUCTIONS

Read this material before using this product. Failure to do so can result in serious injury. KEEP THIS MANUAL. When giving this machine to third parties, always include this manual. We do not accept any liabilities for accidents or damages that result from misuse. Removal/Alteration of any safety devices or of the machine in general will result in the loss of warranty. The buyer assumes all risk and liability arising out of his or her repairs/alterations to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.

  • Always keep your work area well lit, clean and free of obstacles.
  • Do not use the product in the vicinity of ignition sources.
  • Keep children away from your work area.
  • Avoid contact with grounded surfaces (eg. pipes, radiators, etc.) to avoid the risk of electric shock.
  • Do not use the product in moist or wet areas.
  • Never carry the product on its electric cord. Do not pull the cord to unplug the product. Check the cord for any damage on a regular basis.
  • When using the product outdoors, always use suitable outdoor-extension cords/outlets.
  • Always use propper personal protection equipment (eye-protection, gloves, etc.).
  • Make sure the product is turned off when plugging in the cable.
  • Do not wear loose clothing, jewellery or any other accessory that might get caught in the machine. If you have long hair, wear a hair-net.
  • Always disconnect the powercord when doing maintainance work. Never leave the product unattended when children are present.
  • Check the product for any sign of damage each time before you use it.
  • Do not attempt to repair the product when it is damaged! Repair work must only be done by authorized, qualified service technicians.
  • When unused, the compressor should be stored in a dry, locked room out of reach for children.
  • Keep the compressor clean.

PRODUCT DESCRIPTION

erba compressor
Erba Compressor

  1.  Air hose
  2. On/Off switch
  3.  Power connector
  4. Air gun + tire inflating hose
  5. Various adapters (rubber boats, air mattresses, etc.)
  6. Holder for (5)
  7. Dustgun nozzle
  8. Ballneedle
  9. Tire valve adapter
  10. Universal adapter

DESIGNATED USE

The hobby-compressor is designed to provide compressed air for air tools that can be operated with an air flow of up to 180l/min (tire inflator guns, air dust blow guns, etc.). Due to the limited air flow capacity it is not possible to operate air tools that require large amunts of air flow (air sanders, air saws, impact hammers, etc.). Any other use is prohbited. The buyer accepts all liabilities, legal and otherwise, for any damage or injury resulting from improper use of the product (i.e. any other use than the above stated designated use).

RESTRICTIONS

Please note, that this product is not designed for commercial or industrial use. We accept no liability or warranty claims should the product be used in industrial and/or commercial operations.

TECHNICAL DATA

Rated power:

|

230 V ~ 50 Hz

---|---

Engine power:

|

1,5 PS/1100 W, S3 15%

Engine rpm:

|

3750 U/min-1

Working pressure:

|

max. 8 bar

Air consumption:

|

180 l/min

Sound power level LwA:

|

97 dB (A) ± 3 dB

Sound pressure level LpA:

|

83 dB (A) ± 3 dB

IP Class:

|

IP 20

Weight:

|

5,5 kg

NOISE EMISSION VALUES

  • See technical data.

IMPORTANT INFORMATION FOR INITIAL OPERATION

  • Check the product for transport any damage. Notify the carrier if you find any transport damage.
  • Position the compressor as close to the working area as possible to avoid long air hoses and extension cords.
  • Intake air must be dry and clean.
  • After filling the air tank the compressor engine must cool down for 2-5 minutes to avoid overheating.

OPERATION INSTRUCTIONS

Quick coupling (1)
Connect:
Put the plug of your hose directly into the coupling untill you hear a clicking sound.
Disconnect :
Pull back the sleeve of the quick coupling and pull out the plug.

Use the on/off switch (2) to operate the compressor. The maximum continous operation is ,,S3 15%” (1.5 min on and then 8.5 min off for cooldown). After the engine is switched off, the remaining air from the hose will vent with an audible hissing noise. This is normal and no sign of damage.

Troubleshooting

Compressor engine does not work
Cause: No power present.
Solution: Check cables, plugs, fuses and outlets.
Cause: Power level too low.
Solution: Avoid using long extension cords. If you have to use extension cords, make sure they are sufficently thick (at least 2.5 mm2).
Cause: Ambient temperature too low.
Solution: Do not operate below 5 °C.
Cause: Engine overheating.
Solution: Let the engine cool down. Do not operate above 40°C ambient temperature.

Compressor engine working, but no pressure
Cause:        Seals leaky.
Solution:    Check seals and let a certified technician replace them.

SERVICE AND REPLACEMENT PARTS

  • Use original spare parts only.

WARRANTY

  • Legal warranty regulations apply.

DISPOSAL

Our products are packed in order to prevent damage during transport. Packing materials are valuable resurces and therefore can and should be recycled. The product itself consists of various materials (metals, oils, plastic, etc.) and should be disposed with care and in accordance with your federal and local disposal regulations.

 LEGAL INFORMATION

All rights reserved. This manual is copyrighted. Reproduction in and form (digital, print, etc.) is strictly prohibited without the written permission of ERBA GmbH.

DECLARATION OF CONFORMITY

Models:
17001 Hobby Air Compressor oilfree

ERBA GmbH, Talpagasse 6, 1230 Wien, hereby states, that the mentioned model meet the following CE/RoHS quality standards, approvals and relevant safety requirements:

Machinery Directive: 2006/42/EC
EMC Directive: 2014/30/EC
ROHS: 2002/95/EC

  • EN 60335-1:2012/A11:2014 ­
  • EN 1012-1:2010 ­
  • AfPS GS 2014:01 PAK ­
  • EN 55014-1:2006/A2:2011 ­
  • EN 55014-2:2015 ­
  • EN 61000-3-2:2014 ­
  • EN 61000-3-3:2013

signature

For and on behalf of ERBA GmbH (authorized signature)
Dominik Schilling
Technical coordinator
ERBA GmbH, Talpagasse 6, 1230 Wien, Austria