tp-link Business Networking Solution Installation Guide
- June 7, 2024
- tp-link
Table of Contents
Business Networking Solution
Installation Guide
Unmanaged/Easy Smart Rackmountable Switch
TL-SG1008/TL-SG1008PE/TL-SF1016/TL-SF1016DS
TL-SG1016/TL-SG1016S/TL-SG1016D/TL-SG1016DE
TL-SG1016PE/TL-SF1024/TL-SF1024D/TL-SG1024
TL-SG1024S/TL-SG1024D/TL-SG1024DE/TL-SF1048/TL-SG1048
About this Installation Guide
This Installation Guide describes the hardware characteristics, installation
methods and the points that should be attended to during installation. This
Installation Guide is structured as follows:
Chapter 1 Introduction
This chapter describes the external components of the switch.
Chapter 2 Installation
This chapter illustrates how to install the switch.
Chapter 3 Connection
This chapter illustrates how to do the physical connection of the switch.
Appendix A Troubleshooting
Appendix B Hardware Specifications
Audience
This Installation Guide is for: Network Engineer Network Administrator
Conventions
- Some models featured in this guide may be unavailable in your country or region. For local sales information, visit https://www.tp-link.com.
- The figures in Chapter 2 to Chapter 3 are for demonstration purposes only. Your switch may differ in appearance from that depicted.
- This Guide uses specific formats to highlight special messages. The following table lists the notice icons that are used throughout this guide.
| Remind to be careful. Caution indicates a potential that may result in
device damage.
---|---
| Remind to take notice. The note contains helpful information for better use
of product.
Related Document
This Installation Guide is also available in PDF on our website. To obtain
the latest documentation and product information, please visit the official
website: https://www.tp-link.com
Chapter 1 Introduction
Product Overview
The Unmanaged/Easy Smart Switch provides you with a low-cost, easy-to-use,
high-performance, seamless and standard upgrade to improve your old network to
a 100Mbps/1000Mbps network.
TL-SG1008PE/TL-SG1016PE is also a Power Sourcing Equipment (PSE). Eight of
the RJ45 ports on the switch support Power over Ethernet (PoE) function,
which can automatically detect and supply power with those powered devices
(PDs*) complying with IEEE 802.3af and IEEE 802.3at.
Note:
- *PSE is a device (switch or hub for instance) that will provide power in a PoE setup.
- *PoE is a technology that describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet network.
- *PD is a device powered by a PSE and thus consumes energy. Examples include powering IP telephones, wireless LAN access points, network cameras, network hubs, embedded computers etc.
Appearance
- Front Panel
The front panel of TL-SF1016 is shown in the following figure.
Figure 1-1 Front Panel of TL-SF1016
The front panel of The TL-SF1024 is shown as the following figure.
Figure 1-2 Front Panel of TL-SF1024
Unmanaged/Easy Smart Rackmountable Switch
The front panel of The TL-SF1048 is shown as the following figure.
Figure 1-3 Front Panel of TL-SF1048
The front panel of The TL-SF1016DS is shown as the following figure.
Figure 1-4 Front Panel of TL-SF1016DS
The front panel of The TL-SF1024D is shown in the following figure.
Figure 1-5 Front Panel of TL-SF1024D
The front panel of TL-SG1008 is shown as the following figure.
Figure 1-6 Front Panel of TL-SG1008
The front panel of TL-SG1016 is shown as the following figure.
Figure 1-7 Front Panel of TL-SG1016
The front panel of TL-SG1024 is shown as the following figure.
Figure 1-8 Front Panel of TL-SG1024
The front panel of TL-SG1048 is shown as the following figure.
Figure 1-9 Front Panel of TL-SG1048
The front panel of TL-SG1016S is shown as the following figure.
Figure 1-10 Front Panel of TL-SG1016S
The front panel of TL-SG1024S is shown as the following figure.
Figure 1-11 Front Panel of TL-SG1024S
The front panel of TL-SG1016D is shown as the following figure.
Figure 1-12 Front Panel of TL-SG1016D
The front panel of TL-SG1024D is shown as the following figure.
Figure 1-13 Front Panel of TL-SG1024D
The front panel of TL-SG1016DE is shown as the following figure.
Figure 1-14 Front Panel of TL-SG1016DE
The front panel of TL-SG1024DE is shown as the following figure.
Figure 1-15 Front Panel of TL-SG1024DE
The front panel of TL-SG1008PE is shown as the following figure.
Figure 1-1 Front Panel of TL-SG1008PE
The front panel of TL-SG1016PE is shown as the following figure.
Figure 1-16 Front Panel of TL-SG1016PE
LED | Indication |
---|
Power
PWR| On: The switch is powered on.
Off: The switch is powered off or the power supply is abnormal.
Flashing: The power supply is abnormal.
Note: PWR for TL-SG1016PE and Power for other switches.
1000Mbps| On: Running at 1000Mbps.
Off: Running at 10/100Mbps or no device is linked to the corresponding
port.
Note: For TL-SG1016DE/TL-SG1024DE/TL-SG1024/TL-SG1016/TL-SG1024D/
TL-SG1016D/TL-SG1008/TL-SG1016S/TL-SG1024S.
Link/Act| On: A device is linked to the corresponding port and running
properly.
Flashing : Transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: For TL-SG1016DE/TL-SG1024DE/TL-SG1024/TL-SG1016/TL-SG1024D/
TL-SG1016D/TL-SG1008/TL-SF1016/TL-SF1016DS/TL-SF1024/TL-SF1024D/
TL-SF1048/TL-SG1016S/TL-SG1024S/TL-SG1008PE. Green On: Running at 1000Mbps
but no activity.
Green Flashing: Running at 1000Mbps and is transmitting or receiving
data.
Yellow on: Running at 100/10Mbps but no activity.
Yellow Flashing: Running at 100/10Mbps and is transmitting or receiving
data.
Off: No device is linked to the corresponding port.
Note: Only for TL-SG1048.
Speed| On: The port is connecting and supplying power to a PD.
Flashing: The PoE power circuit may be in short, the power current may be
overloaded or non-standard PD is connected.
Off: No PD is connected to the corresponding port, or no power is
supplied according to the power limits of the port.
Note: For TL-SG1016PE and TL-SG1008PE.
PoE Status| On: The port is connecting and supplying power to a PD.
Flashing: The PoE power circuit may be in short, the power current may be
overloaded or non-standard PD is connected.
Off: No PD is connected to the corresponding port, or no power is supplied
according to the power limits of the port.
Note: For TL-SG1016PE and TL-SG1008PE.
PoE Max| On: The power of all the connected PoE ports is between 103W and
110W. No power may be supplied if additional PDs are connected.
Flashing: The power of all the connected PoE ports is ≥110W.
Off: The power of all the connected PoE ports is <103W.
Note: Only for TL-SG1016PE.
On: The power of all the connected PoE ports is between 120W and 126W. No
power may be supplied if additional PDs are connected.
Flashing: The power of all the connected PoE ports is ≥126W.
Off: The power of all the connected PoE ports is <120W.
Note: Only for TL-SG1008PE.
FAN| Green: The fan works properly.
Yellow: The fan doesn’t work properly.
Note: Only for TL-SFG1016PE.
Reset
Press this button for five seconds or above to reset the software setting back
to factory default settings.
Note:
Only TL-SG1016DE/TL-SG1016PE/TL-SG1024DE has a Reset button.
10/100/1000Mbps RJ45 Port
Designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or 1000Mbps. For TL-SG1016PE and TL-SG1008PE, eight of the ports can also provide power for PDs.
10/100Mbps RJ45 Port
Designed to connect to the device with a bandwidth of 10Mbps or 100Mbps.
- Rear Panel
The rear panel is shown as the following figure. Here we take TL-SG1016PE as an example.
Figure 1-17 Rear Panel
Kensington Security Slot
Secure the lock (not provided) into the security slot to prevent the device
from being stolen.
Note:
Only TL-SG1016PE has a Kensington security slot.
Grounding Terminal
The switch already comes with a lightning protection mechanism. You can also
ground the switch through the PE (Protecting Earth) cable of the AC cord or
with Ground Cable. For detailed information, please refer to the Lightning
Protection Guide from the training center of our website:
https://www.tp-link.com/en/configuration-
guides/lightning_protection_guide/?configurationId=2962
Power Socket
Connect the female connector of the power cord here, and the male connector to
the AC power outlet.
Please make sure the voltage of the power supply meets the requirement of the
input voltage (100-240V~ 50/60Hz).
Note:
Please use the provided power cord.
Chapter 2 Installation
Package Contents
Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor.
Note:
The resource CD is only for TL-SG1016DE/TL-SG1024DE/TL-SG1016PE.
Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following rules.
Safety Precautions
- Keep the power off during the installation.
- Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well-grounded.
- Use only the power cord provided with the switch.
- Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch.
- Ensure the vent hole is well ventilated and unblocked.
- Do not open or remove the cover of the switch.
- Before cleaning the device, cut off the power supply. Do not clean it with a waterish cloth, and never use any other liquid cleaning method.
- Place the device with its bottom surface downward.
Site Requirements
Temperature/Humidity
Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate the aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.
Environment | Temperature | Humidity |
---|---|---|
Operating | 0℃ to 40℃ | 10% to 90%RH Non-condensing |
Storage | -40℃ to 70℃ | 5% to 90%RH Non-condensing |
Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity, but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board. To avoid the effect of static electricity on the operation of the switch, please attach much importance to the following items:
- Dust the device regularly, and keep the indoor air clean.
- Keep the device well-grounded and ensure static electricity has been transferred.
Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, and impedance coupling. To decrease the interferences, please make sure to take the following measures:
- Use the power supply that can effectively filter interference from the power grid.
- Keep the device far from high-frequency, strong-current devices, such as radio transmitting stations.
- Use electromagnetic shielding when necessary.
Lightning Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air I the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.
- Ensure the rack and device are well earthed.
- Make sure the power socket has good contact with the ground.
- Keep a reasonable cabling system and avoid induced lightning.
- Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note:
For detailed lightning protection measures, please refer to the Lightning
Protection Guide from the training center of our website:
https://www.tp-link.com/en/configuration-
guides/lightning_protection_guide/?configurationId=2962
Installation Site
When installing the device on a rack or a flat workbench, please note the following items:
- The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least
- The rack or workbench has a good ventilation system. The equipment room is well ventilated.
- The rack is well-grounded. Keep the power socket less than 1.5 meters away from the device.
Installation Tools
- Phillips screwdriver
- ESD-preventive wrist wrap
- Cables
Note:
These tools are not provided with our product. If needed, please self purchase
them.
Product Installation
Desktop Installation
To install the device on the desktop, please follow the steps:
-
Set the device on a flat surface strong enough to support the entire weight of the device with all
fittings. -
Remove the adhesive backing papers from the rubber feet.
-
Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device.
Figure 2-1 Desktop Installation
Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the
instructions described below:
-
Check the grounding and stability of the rack.
-
Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as illustrated in the following figure.
Figure 2-2 Bracket Installation
-
After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure.
Figure 2-3 Rack Installation
Caution:
- Please set 5 to 10cm gaps around the device for air circulation.
- Please avoid any heavy things placed on the device.
- Please mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation.
Chapter 3 Connection
Ethernet Port
Connect an Ethernet port of the switch to the computer by RJ45 cable as the
following figure shows.
Connect an Ethernet port of the switch to the computer by RJ45 cable as the
following figure shows.
Figure 3-1 Connecting the RJ45 Port
Verify Installation
After completing the installation, please verify the following items:
- There is 5 to 10cm of clearance around the sides of the device for ventilation and the airflow is adequate.
- The voltage of the power supply meets the requirement of the input voltage of the device.
- The power socket, device, and rack are well-grounded.
- The device is correctly connected to other network devices.
Power On
Plugin the negative connector of the provided power cord into the power socket
of the device, and the positive connector into a power outlet as the following
figure shows.
Figure 3-2 Connecting to Power Supply
Note:
The figure is to illustrate the application and principle. The power plug you
get from the package and the socket in your situation will comply with the
regulation in your country, so they may differ from the figure above.
Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly. During this time, the LED indicators will respond as follows:
- The PWR/Power LED indicator will light up.
- The LED indicators of all the ports will flash momentarily and then turn off again after the initialization.
Accessing the Switch
Note:
Only for TL-SG1016DE/TL-SG1024DE/TL-SG1016PE, you can access and manage the
switch.
After the initialization is finished, you can access and manage the switch
using the Web-based GUI (Graphical User Interface) or using the Configuration
Utility.
Using the Web-Based GUI
To access and manage the switch using the Web-Based GUI, take the following
steps:
Find the IP address of the switch.
- By default, the switch receives an IP address from a DHCP server (or a router that functions as a DHCP server) in your network. You can find this IP address on the DHCP server.
- If the switch cannot receive an IP address from a DHCP server, it uses the static IP address of 192.168.0.1, with a subnet mask of 255.255.255.0.
Configure IP address on your PC to make sure the switch and PC are in the same subnet.
- If the switch uses an IP address assigned by a DHCP server, set your PC to obtain an IP address automatically from the DHCP server.
- If the switch uses the static IP address of 192.168.0.1, configure your PC’s IP address as 192.168.0.x (”x” ranges from 2 to 254), and subnet mask as 255.255.255.0.
Launch a web browser on your PC. Enter the IP address of the switch in the address bar and press Enter. Log in with admin as both user name and password.
Now you can configure the switch using the Web-based GUI. For further
information, refer to the User Guide on the Resource CD. You can find the
latest version of this guide on the official website:
https://www.tp-link.com/en/download-center.html.
Using the Configuration Utility
You can find the configuration utility on the resource CD or download it from
the official website: https://www.tp-link.com/en/download-center.html.
For detailed information about using the configuration utility, refer to the
Easy Smart Configuration Utility User Guide on the Resource CD. You can find
the latest version of this guide on the official website: https://www.tp-
link.com/en/download-center.html.
Appendix A Troubleshooting
Q1. What could I do if I forgot the username and password of the Switch?
With the switch powered on, press the reset button for at least 5 seconds to
reset the system.
The system will be reset to the factory default settings, and the default
login user name and password are both admins.
Q2. What should I do if I cannot access the web management page?
Please try the following:
- Check every port LED on the switch and make sure the Ethernet cable is connected properly.
- Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
- Power off the switch and, after a while, power it on again.
- Make sure the IP address of your PC is set within the subnet of the switch.
- If you still cannot access the configuration page, please restore the switch to its factory defaults.
Then the IP address of your PC should be set as 192.168.0.x (“x” is any number from 2 to 254) and Subnet Mask as 255.255.255.0.
Q3. Why does the Power/PWR LED work abnormally?
The Power/PWR LED should be lit up when the power system works normally. If
the Power/PWR LED worked abnormally, please try the following:
- Make sure that the power cable is connected properly, and the power contact is normal.
- Make sure the voltage of the power supply meets the requirement of the input voltage of the switch.
Q4. Why is the Link/Act LED not lit while a device is connected to the
corresponding port?
Please try the following:
- Make sure that the cable connectors are firmly plugged into the switch and the device.
- Make sure the connected device is turned on and working normally.
- The cable must be less than 100 meters long (328 feet).
Item | Content |
---|---|
Standards | IEEE 802.3i, IEEE 802.3u, IEEE 802.3x |
IEEE 802.3ab (except TL-SF1016/TL-SF1016DS/TL-SF1024/TL-SF1024D/TL-SF1048)
IEEE 802.1p (for TL-SG1016DE/TL-SG1024DE/TL-SG1016PE/TL-SG1008PE/
TL-SG1008/TL-SG1016S/TL-SG1024S)
IEEE 802.1q (for TL-SG1016DE/TL-SG1024DE/TL-SG1016PE)
IEEE 802.3af (for TL-SG1008PE/TL-SG1016PE)
IEEE 802.3at (for TL-SG1008PE/TL-SG1016PE)
Transmission Medium| 10Base-T: 2-pair UTP/STP of Cat. 3 or above (maximum
100m)
100Base-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100m)
1000Base-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100m) (except TL-
SF1016/
TL-SF1016DS/TL-SF1024/TL-SF1024D/TL-SF1048)
Frame Forward Rate| 10Base-T: 14881pps/Port
100Base-X: 148810pps/Port
1000Base-T: 1488095pps/Port (except TL-SF1016/TL-SF1016DS/TL-SF1024/
TL-SF1024D/TL-SF1048)
LEDs| Power, Link/Act (for TL-SG1048/TL-SF1016/TL-SF1016DS/TL-SF1024/TL- SF1024D/
TL-SF1048)
Power, 1000Mbps, Link/Act, PoE Status, PoE MAX (for TL-SG1008PE)
PWR, Speed, PoE Status, PoE MAX, FAN (for TL-SG1016PE)
Power, 1000Mbps, Link/Act (for other switches)
Operating Temperature| 0℃ to 40℃ (32 to 104 ℉)
Storage Temperature| -40℃ to 70℃ (-40 to 158 ℉)
Operating Humidity| 10% to 90%RH Non-condensing
Storage Humidity| 5% to 90%RH Non-condensing
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of directives 2014/30/EU,
2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at https://www.tp-
link.com/en/ce
Safety Information
- Keep the device away from water, fire, humidity or hot environments.
- Do not attempt to disassemble, repair, or modify the device.
- Do not use a damaged charger or USB cable to charge the device.
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Symbol | Explanation |
---|---|
AC voltage | |
Indoor use only | |
RECYCLING |
This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
The user has the choice to give his product to a competent recycling organization or to the retailer when he buys new electrical or electronic equipment.
For technical support, User Guide and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
© 2018 TP-Link
7106508088
REV3.0.2
References
- TP-Link Australia - WiFi Networking Equipment for Home & Business
- lightning_protection_guide
- Download Center | TP-Link
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>