NUGSMASHER PRO NS020624 Extractor Choice Master Bundle Owner’s Manual

May 15, 2024
NUGSMASHER PRO

NUGSMASHER-LOGO

NUGSMASHER PRO NS020624 Extractor Choice Master Bundle

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-product-
image

Product Specifications

  • Model : NugSmasher Pro
  • Version : 2.1
  • Temperature Settings : Fahrenheit for US models, Celsius for international orders
  • Bag Loading Capacities:
    • 3.5g bag: 1.1g-3.5g, Diameter 1.5-1.6
    • 7g bag : 3.6g-7g, Diameter 2-2.2
    • 14g bag : 7.1g-14g, Diameter 2.4-2.7

Product Usage Instructions

Quick Start Guide
KEEP RELEASE VALVE IN CLOSED CLOCKWISE POSITION WHEN NOT IN USE

  • Adjusting Temperature:
    Press the up or down arrows (green circles) to select desired temperature setting. Once you have changed to your desired temperature, press the enter button (red circles) once to lock in temperature. Avoid going into other programming modes as the unit is factory preset for optimum settings.

  • PID Controller
    The PID controller helps maintain precise temperature control and extraction efficiency.

Unit Operation

  • Ideal Temperature: Maintain the recommended temperature for optimal extraction results.
  • Pressure: Adjust plate pressure and gauge pressure based on the material’s surface area and quantity for the best extraction outcomes.
  • Loading Micron Bags: Follow the guidelines for loading different sizes of bags to achieve consistent extractions.

Pressure System

  • Plate Pressure vs. Gauge Pressure: Understand the relationship between plate pressure and gauge pressure to apply the correct pressure for efficient extraction.
  • Surface Area Key: Use the provided surface area measurements to ensure proper pressure (PSI) on your product for consistent results.

Frequently Asked Questions (FAQ)

  1. Q: What should I do if my item is damaged during shipping?
    A: If your item does not deliver safely due to shipping issues, please contact us directly for immediate resolution.

  2. Q: How do I adjust the temperature settings?
    A: Use the up or down arrows to select the desired temperature setting and press the enter button to lock it in.

  3. Q: What are the recommended loading capacities for different bag sizes?
    A: Refer to the user manual for loading capacities based on bag sizes to ensure proper extraction.

rosin made simple
owners manual

  • Version 2.1
  • NS020624
  • Copyright © 2019 NugSmasher. All Rights Reserved.

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(1\)

  • Thank you for the purchase of your NugSmasher® Pro. We have designed this unit for the purpose of effortless rosin extraction for up to 1/4 pound of flower. When setting up your unit, please ensure your stand is suitable for the weight of the machine. Also note, that the unit gets hot and the high temperature hydraulic heat plates are capable of bodily injury if not used in a safe manner. (Please do not attempt to open your unit casing as this will void your factory warranty.)
  • While our products are sturdy and built to last, they are also heavy and shippers can be rough during handling. If there are any problems from shipping and your item does not deliver safely please contact us direct so we can resolve the matter immediately.
  • As always, please feel free to call us at any point with any questions or concerns at 951-272-9800 or NugSmasher®.com/contact.
  • Your release knob is packaged in foam near the heat plates and will be installed on the right side of unit towards bottom of press.
  • Notice the keyed end of the release valve as it slides through side of unit and can be installed easily by looking at rear of machine under manual handle sticker.
  • Rotating release knob clockwise till it is tight will allow press plates to be raised via manual handle or pneumatically with 90-100 psi air compressor (3-5) gallon small compressor is ideal. Using a water separator is recommended to minimize any water from entering the unit.
  • Rotating release knob counter clockwise will allow plates to separate and open – never open beyond one-half turn to release plates as damage and loss of fluid may occur.

KEEP RELEASE VALVE IN CLOSED “CLOCKWISE POSITION” WHEN NOT IN USE

Please note that under any circumstances do not turn release valve more then ½ a turn in the open (counter clockwise) direction as this will void your warranty and may result in hydraulic fluid loss. Also make sure when not in use or stored, the release valve must be in closed tight (clockwise) position.

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(4\)

  • WARNING!
    Never turn your release knob more than ½ full turn counter clock wise from tight.

  • Please Note:
    Your release knob is factory designed to be a slight upward.

Before your unit is turned on, (If using as manual operated pump) insert handle into rear inset opening on left side of unit. Notice there is a round tube that your shaft handle will be inserted into for plate compression operation and a ¼-20 set screw to hold in place.

  • Set power switch to the “on” position (red circle). You will notice on your control screen there are two rows of digits.
  • The top is the current temperature of the heat plates. The bottom is the set temperature. The Pro comes preset at 200 degrees Fahrenheit and will take approximately 10-12 minutes to reach set temperature depending on your location. The NugSmasher® Pro has 3 heating elements in each plate and top and bottom plates are individually controlled by your PID controllers, it is recommended you keep top and bottom plates at same temperature for best results.

Adjusting Temperature

Press the up or down arrows (green circles) to select desired temperature setting. Once you have changed to your desired temperature press the enter button (red circles) once to lock in temperature. It is not advised to go into any other programming modes as your unit has been factory preset for optimum settings.
Note: US models are set for Fahrenheit and all international orders are set in Celsius unless specified otherwise.

LCD display economical intelligent temperature controller

Main features

  • New generation of high-end controller, large window, high contrast LCD and easy to read white PV display, which improves the visibility of all angles and achieve long-distance visibility.
  • Built-in waterproof sealing ring and externally mounted waterproof sealing ring make the front panel have good waterproof performance.
  • Plastic handle waterproof button, the button operating surface strong, scratch-resistant and wear- resistant, operation feel clear and smooth.
  • Economic type, simple operation ,practical function, specially designed for temperature control.
  • Common thermocouple and RTD input type can be selected through software parameter settings.
  • The measurement accuracy reaches 025% level. The measurement error caused by temperature drift and time drift is eliminated by using digital correction and self-calibration technology.
  • Advanced “FUZZY+PID” ai intelligent control mode, no overshoot and with the function of auto tuning (AT) and self-adaptation.
  • Can provide most two way alarm output, and can implement a variety of alarm methods.
  • The °C or °F temperature unit can be selected via software parameter settings.
  • High-efficiency and high-reliability switching power supply, global universal voltage range AC100~240V or AC/DC12~24V.
  • The anti-jamming performance meets the requirements of electromagnetic compatibility (EMC) under harsh industrial conditions.

Technical Specification

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(23\) NUGSMASHER-PRO-NS020624
-Extractor-Choice-Master-Bundle- \(24\)

Ordering Code Definition

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(7\)

Wiring diagram.

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(8\) NUGSMASHER-PRO-NS020624-Extractor-
Choice-Master-Bundle- \(9\)

Front Panel Description

  1. 1 Display window (displays measurements, parameter names, and so on)

  2. SV display window (displays given values, parameter values, and so on)

  3. MV third display display temperature unit, program remaining time / program segment number

  4. Output indicators: OUT ,AL1, AL2, AUX indicators

  5. Parameter key: Entry / exit parameter settings )
    Return key : confirm and switch to the next parameter ) Data shift key (Also as manual/automatic switching and program setup key).

  6. Data decrease key(Also as run key) 9 Data increase key(Also as stop key)

Display the status and basic operation

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(11\) NUGSMASHER-PRO-NS020624
-Extractor-Choice-Master-Bundle- \(12\)

  • System parameter setting In the basic display state, press and hold key 2 seconds, Enter the field parameters, set the LOC = 800, Then press the # button to confirm and enter the system parameter setting state. ‹ , V , ^ Key can directly modify the parameter values. Press the key to reducing the data, press the ^ key to increase the data, Waiting to modify the value of the decimal point will flash (like a cursor).press key and hold, you can quickly increase / decrease in value, And the speed will be automatically accelerated. also press the < key to move to modify the data location (cursor), the operation is more efficient. Key can be stored to modify parameter values and display the next parameter, press and hold < key 2 seconds, and can return to the previous parameter; press and hold * key 2 seconds can immediately exit the parameter setting state.

  • Set Value Setting
    In the basic display state, press , , key can directly modify the given value.

  • “At” PID Parameter auto-tuning The optimal PID control parameters can be determined by the auto-tuning controller, thereby obtaining precise control: Press < and hold for 2 seconds, the At parameter appears, “At” parameter “OFF” is set to “ON” and then press the + Key to confirm instrument can start the implementation of the auto- tuning Given function, the instrument in the basic display state display will flash the word “At”, the instrument after 2 oscillation cycle ON-OFF control can automatically calculate the PID parameters. If you want to advance to give up auto-tuning, “At” parameter “ON” is set to “OFF” and then press key to confirm. Given tuning parameter values obtained are not identical, to perform auto-tuning function, should be first given value set in The most commonly used value or middle value, if the system is good insulation properties of the furnace, the given value should be set in the system uses the maximum, and then Execute the start of the operation of auto-tuning function. Reasons to learn, auto-tuning after the initial use, the effect may not be the best, you need a period of time (usually the same time auto-tuning control) before they can get the best results. *Do not operate the controller or interrupt the power supply during the auto-tuning process.

7.2 system parameter Set Loc = 800, then press the f key to enter the
following system parameters

system parameter
Set Loc = 800, then press the key to enter the following system parameters

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(30\) NUGSMASHER-PRO-NS020624
-Extractor-Choice-Master-Bundle- \(31\) NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(32\)NUGSMASHER-PRO-NS020624
-Extractor-Choice-Master-Bundle- \(33\)

Partial application wiring method

The wiring method of the input signal

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(15\)

If the input wiring error, sensor damage, over-range or Int settings and input sensor types are inconsistent, there will be “orAL” warning flicker, After these faults need to be eliminated, the PV can measure the display normally.

Main control output wiring method

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(15\)NUGSMASHER-PRO-NS020624
-Extractor-Choice-Master-Bundle- \(16\)

The NugSmasher® Pro can be used with a manual pump handle or pneumatic operation with push button actuation of plates. The NugSmasher® Pro requires a compressor (not included) with a minimum psi of 100 psi and 3-5 gallon air capacity. Note the larger the supply tank the less you will have your compressor cycling on and off. Attach compressor and airline to input line which comes rolled up and recessed on rear inset panel on right side of machine.

Ideal Temperature:
The ideal pressure and temperature will vary depending on strain and growing techniques so don’t be discouraged on your results when you press new material. We recommend when pressing a new strain to start at approx. 220 degrees for flower and notate your yield results (weight of material in vs. rosin out). Perform additional test presses and drop 5-7 degrees per press until you notice your yield percentage starting to drop. Adjust back to the previous temp and that will be your ideal temp for that strain. It is advised to have a thermal temp gun to verify and check temperatures from time to time. Use our temperature test strips included with your unit (also available for purchase at NugSmasher®.com), unless in a pinch use a small piece of electrical tape as the high gloss on heat plates will affect accurate temp readings if using a thermal temp gun. (As shown in Illustration)

Pressure:
Once your unit reaches set temperature you’re ready to start pressing. Once you have your material between parchment paper -do not use wax paper!-, slowly start raising plates. It is key to do this slowly to properly build heat into your material. The entire pressing process should be between 90- 120 seconds depending on your strain. Your NugSmasher® Pro is most capable of over pressing your material as the mistake made most with new extractors. See, NugSmasher®.com/tools/calculator tool for pressure calculations for your NugSmasher® Pro. There are several videos available online on the NugSmasher® social Instagram account as well as the NugSmasher® YouTube channel that are very beneficial for techniques and tips of your rosin extraction. Note: Do not use other leverage device or foot to push manual handle down as you will cause damage not covered by warranty.

Loading Micron Bags:
NugSmasher® extraction bags, are recommended for optimal yield and clean quality rosin. Our bags are hand-made and packaged in the USA! NugSmasher® extraction bags are specifically designed to work with the weight of fresh cured flower and are labeled accordingly at: 3.5 g (1.1g-3.5g), 7 g (3.6g-7g) and 14 g (7.1g-14g). This assumes the bags are loaded (BTS) or bottle/barrel- tech style (upright so that you end up with the round coin like puck once fully pressed). This perfected method allows you the ability to put the proper weight of flower into the bag and get a consistent extraction every time. This method also applies the proper pounds per square inch of pressure (PSI) on your product and eliminates the guess work.

  • 3.5g bag (1.1g-3.5g) = 1.5”-1.6”
  • Diameter 7g bag (3.6g-7g) = 2”-2.2”
  • Diameter 14g bag (7.1g-14g) =2.4”-2.7”
  • Diameter
  • Remember
  • “Fire in fire out!”

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(20\)

As the micron gets smaller the diameter gets larger, this is the reason for the variance in the diameter numbers above. We prefer to use 160 micron for fresh flower, as flower dries we go down in micron screen size (for dry flower use 90 micron). Micron size determines the diameter (surface area) of the smashed bag. For nugs 1g and smaller no bag is necessary. For more details about loading Bottle-Tech and/or Barrel-Tech style (BTS) please visit NugSmasher® on YouTube: https://www.youtube.com/watch?v=0osvcD7CLK0

Plate Pressure:

Plate Pressure:
The applied plate pressure is determined by the extracted material’s surface area (bag, size and quantity) and the applied pressure to the extraction (Gauge PSI Reading)
NugSmasher® Pro Consistency Chart PSI to Surface Area Bag Selection

PSI ON Material 500 750 1000 1250 1500 One 3.5G Bag (BTS)
Gauge Reading 258 387 516 645 774
PSI ON Material 500 750 1000 1250 1500 Two 3.5G

Bags (BTS)

Gauge Reading| 515| 774| 1031| 1289| 1547
PSI ON Material| 500| 750| 1000| 1250| 1500| Three 3.5G Bags (BTS)
Gauge Reading| 773| 1160| 1547| 1934| 2321
PSI ON Material| 500| 750| 1000| 1250| 1500| One 7G Bag (BTS)
Gauge Reading| 459| 687| 917| 1146| 1375
PSI ON Material| 500| 750| 1000| 1250| 1500| Two 7G Bags (BTS)
Gauge Reading| 917| 1375| 1834| 2292| 2751
PSI ON Material| 500| 750| 1000| 1250| 1500| Three 7G Bags (BTS)
Gauge Reading| 2751| 4126| 5502| 6877| 8253
PSI ON Material| 500| 750| 1000| 1250| 1500| One 14G Bag (BTS)
Gauge Reading| 716| 1075| 1432| 1791| 2149
PSI ON Material| 500| 750| 1000| 1250| 1500| Two 14G Bags (BTS)
Gauge Reading| 1433| 2149| 2865| 3582| 4298
PSI ON Material| 500| 750| 1000| 1250| 1500| Four 14G Bags (BTS)
Gauge Reading| 2865| 4298.65| 5731.54| 7164| 8598

-VS-

Gauge Pressure

Gauge Pressure:
Gauge pressure (psi) is measured from the hydraulic rams fluid pressure. This is the applied pressure and should be adjusted to the surface area to achieve optimum results.

Surface Area Key

  • NugSmasher® extraction bags, our bags are recommended or optimal yield and clean quality rosin. NugSmasher® extraction bags are specifically designed to work with the weight of fresh cured flower together with our extraction machines and are labeled accordingly at: 3.5g, 7g and 14g this assumes the bags are loaded (BTS) or bottle/barrel-tech style (upright so that you end up with the round coin like puck once fully pressed).
  • This perfected method allows you the ability to put the proper eight of flower into the bag and get a consistent extraction very time. The reason for this is that it allows for the proper pounds per square inch, pressure (PSI) on your product and eliminates the guess work.
    • 3.5g = 1.5” Diameter = 1.77” in surface area
    • 7g = 2”-2.2”Diameter= 3.14” in surface area
    • 14g=2.4”-2.7”Diameter= 4.91” in surface area.
  • We prefer to use 160 micron for fresh flower, as flower dries we go down in micron screen size (for dry flower use 90 micron).
  • NOTE: As the micron gets smaller the diameter get slightly larger.
  • Example: 90 micron is about 5% larger at the end of your extraction.
  • For the Pro Calculator tool, please visit, NugSmasher.com/tools

EXTRACTION EXAMPLE:

One 14g Bag

  • Plate Pressure
  • 750 PSI
  • There is only one 3.5g bag that has the total surface area of around 1.77in2.
  • Gauge Pressure
  • 1074 PSI
  • To extract your material at 750 PSI with a surface area of 1.77in (one 14g bag) it would equal 1074 PSI on your gauge.

Four 14g Bags

  • Plate Pressure
  • 750 PSI
  • There are two 3.5g bags
  • that has a total combined surface area of around 3.54in2.
  • Gauge Pressure
  • 4298 PSI
  • To extract your material at 750 PSI with a surface area of 3.54in2 (1.77in2 for each 14g bag) you would need 4298 PSI on your gauge.

top plate view:

NUGSMASHER-PRO-NS020624-Extractor-Choice-Master-Bundle-
\(34\)

  • Copyright © 2019 All rights reserved. No part of this manual may be reproduced or used in any manner without written permission of the copyright owner.
  • The contents of this document may be subject to change without notice.
  • Due to improvement or change of this device, the description of this document could be partially different in specification, for which your understanding is requested.
  • With the exception of what is provided for in the warranty provisions of NugSmasher®, we do not assume any liability against the damages (including but not limited to the loss of profit, indirect damage, special damage or other monetary damages) arisen out of the use or failure to use this product properly. The same shall also apply to the case even if NugSmasher® had been notified of the  possibility of arising damages in advance. As an example, we shall not be liable for any loss of material made using this product or indirect damages caused by the product.
  • Use of your NugSmasher® press should be done in accordance with all local, state and federal regulations. It is owner/users responsibility to know and understand laws and regulations regarding concentrates. NugSmasher® has no responsibility of how product is used and products produced with it.
  • Keep away from children, pets and clothing.
  • Never leave the extractor on when you go to sleep or leave the area.
  • Never use or store flammable liquids (such as gasoline) around the extractor. The flammable vapors can flow from one part of the room to another and be ignited by an electrical spark.
  • Place at least three feet away from objects such as bedding, furniture and drapes. Do not place where towels or other objects could fall on the extractor and start a fire.
  • Use extractor on the floor or bench top. Never place on furniture, since unit may fall , which could result in a fire or shock hazard. Do not use in wet or moist places, such as bathrooms; corrosion or other damage to parts in the unit may lead to a fire or shock hazard.
  • Do not hide cords under rugs or carpets. Placing anything on top of the cord or unit as it could cause the cord or machine to overheat, and can cause a fire.
  • Do not use an extension cord unless absolutely necessary. Using a light-duty, household extension cord with high-wattage appliances can start a fire. If you must use an extension cord, it must be marked #14 or #12 AWG; this tells the thickness or gauge of the wire in the cord. Do not use a cord marked #16 or #18 AWG. Only use extension cords bearing the label of an independent testing laboratory such a U.L. or E.T.L.
  • Be sure the plug fits snugly in the outlet. Since a loose plug can overheat, have a qualified repairman replace the worn-out plug or outlet. Since extractor draw lots of power, the cord and plug may feel warm. If the plug feels hot, unplug the heater and have a qualified repairman check for problems. Using an extractor with a hot cord or plug could start a fire.
  • If a extractor is used on an outlet protected by a ground fault circuit interrupter (GFCI) and the GFCI trips, do not assume the GFCI is broken. Because GFCls protect the location where leakage currents can cause a severe shock, stop using the extractor and have it checked, even it if seems to be working properly.
  • Broken extractor should be checked and repaired by a qualified service center. Do not attempt to repair, adjust or replace parts yourself as this will void warranty.

rosin made simple

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals