MASTECH Infrared Thermometer User Manual

June 7, 2024
MASTECH

MASTECH Infrared Thermometer

Description

This product uses infrared induction principle can be fast, accurate temperature measurement of the amount that can quickly selected from a large population the higher temperature.

  • Automatic temperature compensation.
  • Range:32°C~42°C (special object)
  • °C/°F Selectable

Warning

  • Please read the following information carefully before using the meter.
  • the temperature measurement for reference only,
  • Measurement distance: 5~1I5cm.

Panel

  1. Screen
  2. Mode key
  3. Backlight key
  4. measuring type swap
  5. °C/°F key
  6. Sensor
  7. Trigger
  8. Battery cover

Display

  1. Scan status
  2. Emissivity
  3. Low battery
  4. °F unit
  5. °C unit
  6. Secondary display
  7. Primary display
  8. Surface scan
  9. Hold status

Operagoing thermometer

  • To measure temperature, the measuring distance 5 ~ 15cm; press the trigger start measuring, approx 1s, the meter display measuring temperature to measurement complete.
  • The meter turns off when no activity is detected for ten seconds.
  • A longer press key to light on or off the backlight.
  • Press key to enter alarm or temperature adjust function .
  • A longer press fil key to switch between °C or °F.
  • Press key to swap measuring type.

D:S ratio

Make sure that the target is larger than the meter’s visual spot size. The smaller the target, the closer you should be to it. The relationship between distance and spot size is 10:1

Alarm function

  1. Unit
  2. Alarm value
  3. Alarm indicator
  • Press key switch to alarm function status.
  • Press key to switch between different types of object.
  • Press ▲ key to increase the alarm value.
  • Press ▼ key to decrease the alarm value.
  • Press key to save and exit alarm function status .

Temperature adjust

  1. Unit
  2. Temperature adjust value
  3. Temperature adjust status
  • Press key switch to alarm function status.
  • Press ▲ key to increase the alarm value.
  • Press ▼ key to decrease the alarm value.
  • Press key to save and exit temperature adjust status.

Note 1:
When ambient temperature changes quickly, must wait 30 minutes to balance the temperature of the instrument before use.

Note 2:
When the battery voltage is lower, the battery symbol appears, it indicates that we must change the battery.

WARNING


Do not mix old and new batteries. Do not mix alkaline , standard (carbon -zinc),or rechargeable (ni -cad ,ni -mh ,etc ) batteries .

Specifications

Temperature range| 0°C~100°C (32°F~212°F)- surface
32°C~42°C(89°F~108°F)- special object
---|---
Accuracy: Assumes ambient Operating temperature (23°C + 2°c or 73°F+3°F)| 0°C~100°C +( 1 .5%, rdg+2°C) – surface
32°F~212°F ±(1.5%, rdg+3°F)- surface
32°C~42°C (±0.4°C) – special object
Optical resolution| 10:1| Spectral response| 8-14 um
Repeatability| 0.2°c| Response time| Approx.1s
Resolution| 0.1°C/0.2°F| Emissivity| 0.95
Ambient Operating Range| 0°C~40°C- surface
15 °C~35 °C- special object| Relative humidity| 10%~90°/o
CE| Conforms to EN61326| Dimensions| 148x95x50mm
Power| 2×1.5V AAA| Weight| 150g

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals