Lenovo ThinkSystem DB630S 32Gb FC SAN Switch User Guide
- June 3, 2024
- Lenovo
Table of Contents
- Lenovo Think System DB630S 32Gb FC SAN Switch Product Guide
- Did you know?
- Key features
- Components and connectors
- System specifications
- Port activation licenses
- Transceivers and cables
- Enterprise Bundles and Integrated Routing features
- Management software
- Fibre Channel standards
- Rack installation
- Physical specifications
- Operating environment
- Warranty and support
- Services
- Regulatory compliance
- Rack cabinets
- Power distribution units
- Uninterruptible power supply units
- Related publications and links
- Notices
- Trademarks
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Lenovo ThinkSystem DB630S 32Gb FC SAN Switch
Lenovo Think System DB630S 32Gb FC SAN Switch Product Guide
The Lenovo Think System DB630S FC SAN Switch delivers 32 Gb Gen 6 Fiber
Channel technology with industry-leading port density and combines
scalability, reliability, flexibility, simplicity, and enterprise-class
functionality to meet the demands of hyper-scale, private cloud storage, and
growing flash-based and NVMe storage environments.
The DB630S FC SAN Switch is a dense, 2U rack-mount storage networking switch
that offers 96x SFP+ ports that support 4/8/10/16/32 Gbps speeds and 8x QSFP+
ports that support 128 Gbps (4x 32 Gbps) or 4x 4/8/16/32 Gbps speeds. The
DB630S FC SAN switch offers a rich set of standard features with the options
to expand its capabilities as needed, providing “pay-as-you-grow” scalability
to meet the needs of an evolving storage environment.
The DB630S FC SAN Switch features easy integration into the existing SAN
environments while realizing the benefits of Gen 6 Fiber Channel connectivity.
The switch provides full non-blocking performance with Ports On Demand
scalability to support SAN expansion and enable long-term investment
protection.
The following figure shows the Lenovo Think System DB630S 32Gb FC SAN Switch.
Did you know?
The DB630S FC SAN Switch leverages storage connectivity technologies from
Brocade, a leader in Fiber Channel networking.
Fabric Vision technology, an extension of Gen 6 Fiber Channel, provides
unprecedented insight and visibility across the SAN with powerful built-in
monitoring, management, and diagnostic tools.
With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that
offers “one stop shop” and single point of contact for delivery of leading
edge technologies and innovations from Lenovo and other leading IT vendors.
These offerings can satisfy the wide range of your end-to-end IT
infrastructure needs, including end-user devices, servers, storage,
networking, services, management software, and financing.
Key features
The Think System DB630S FC SAN Switch offers the following features and benefits:
- Provides high scalability in a dense, 2U switch with 96 SFP+ ports and 8 QSFP+ ports (each QSFP+ port has 4x 32 Gb FC links for 128 Gb FC connectivity between the DB630S or DB620S FC SAN switches, or it can be broken out to four links to 4/8/16/32 Gbps SWL optics in a server HBA, storage device, or another FC switch, for a total of up to 128 connections) to support high-density server virtualization, cloud architectures, and flash-based storage environments.
- Enables cost-effective “pay-as-you-grow” scalability from 48 to 128 ports with Ports On Demand (POD).
- Increases performance for demanding workloads with support for 128 Gbps (4x 32 Gbps) and 32 Gbps FC links.
- Simplifies end-to-end management of large-scale environments by automating repetitive daily management tasks.
- Optimizes fabric behavior and ensure sufficient bandwidth for mission-critical applications with advanced traffic management capabilities and adaptive networking.
- Provides proactive, non-intrusive, real-time monitoring and alerting of VM and storage I/O health and performance with VM Insight and IO Insight through integrated network sensors.
- Leverages predefined MAPS policies to automatically identify and isolate devices that cause network performance issues.
- Protects existing device investments with auto-sensing 4, 8, 16, and 32 Gbit/sec capabilities and native operation with Brocade fabrics.
- Runs Fabric OS, which delivers distributed intelligence throughout the network and enables a wide range of value-added features.
- Leverages Fabric Vision technology’s powerful monitoring, management, and diagnostic tools to simplify administration, increase uptime, and reduce costs.
- Supplies a rich set of standard features at no extra cost, including fabric services, advanced zoning, adaptive networking, full fabric operations, integrated 10 Gb FC, and diagnostic tools.
- Expands fabric capabilities with optional licensed functions, including trucking, advanced monitoring and alerting, long-distance fabrics, and FC-FC routing.
- Compresses and encrypts in-flight data on up to 12 ports for more efficient link utilization and higher security.
- Virtualizes physical FC SAN switches and fabrics into logical entities for better flexibility, utilization, management, and efficiency.
- Allows organizations to seamlessly integrate Gen 6 Fiber Channel networks with the next generation of flash storage – NVMe over Fiber Channel – by being NVMe-ready, without a disruptive rip and replace, to achieve faster application response times and harness the performance of solid state drives for better scalability across virtual data centers with flash storage.
- Optimizes performance and ensures reliability with enhanced monitoring for NVMe.
- Maximizes resiliency with redundant hot-swap fan assembly units and power supplies.
- Accelerates troubleshooting with built-in advanced diagnostics tools featuring Clear Link Diagnostics with D Ports and select adapters from Q Logic and Emulex, which helps ensure optical and signal integrity for 16 Gb and 32 Gb Fiber Channel optics and cables.
Components and connectors
The following figure shows the port-side view of the DB630S FC SAN Switch.
The port-side panel of the DB630S FC SAN Switch includes the following components:
- 96x SFP+ ports to attach SFP+ transceivers for 4/8/10/16/32 Gb FC connections.
- 8x QSFP+ ports to attach QSFP+ transceivers for 128 Gb or 4x 32 Gb FC connections.
- One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.
- One RJ-45 RS-232 console port for configuring the switch.
- One USB port for mass storage devices.
- LEDs that display the status of the switch and the network.
The following figure shows the non-port side view of the DB630S FC SAN Switch.
The non-port-side panel of the DB630S FC SAN Switch includes the following components:
- Two redundant hot-swap 1500 W AC power supplies (each with the IEC 320-C14 power connector).
- Three N+1 redundant hot-swap system fan assembly units (each with two fans).
System specifications
The following table lists the Think System DB630S system specifications.
Table 1. System specifications
Component
|
Specification
---|---
Machine type| 7D1S
Form factor| Standalone or 2U rack mount
Ports|
- 96x SFP+ ports:
- Model CTO5: 48 ports activated and 48x 32 Gb FC SWL SFP+ transceivers included; up to two optional 24-port activation licenses or bundles (24-port licenses and 24x 32 Gb FC SWL SFP+ transceivers)
- Model CTO6: 96 ports activated and 96x 32 Gb FC SWL SFP+ transceivers included
- 8x QSFP+ ports (require an optional activation license or bundle [32-port license pack and 8x 128 Gb FC SWL SFP+ V2 transceivers])
Media types|
- 128 Gb (4x 32 Gb) FC QSFP+: short wavelength (SWL), long wavelength (LWL)
- 4x 16 Gb FC QSFP+: SWL
- 32 Gb FC SFP+: SWL, LWL, extended long wavelength (ELWL)
- 16 Gb FC SFP+: SWL, LWL, extended long wavelength (ELWL)
- 10 Gb FC SFP+: SWL, LWL
Port speeds|
- 128 Gb (4x 32 Gb) FC SWL QSFP+:
- 128 Gbps, 4x 32 Gbps, or 4x 16 Gbps 128 Gb (4x 32 Gb) FC LWL QSFP+: 128 Gbps or 4x 32 Gbps fixed
- 4x 16 Gb FC QSFP+: 4x 16/8/4 Gbps auto-sensing
- 32 Gb FC SFP+: 32/16/8 Gbps auto-sensing 16 Gb FC SFP+:
- 16/8/4 Gbps auto-sensing
- 10 Gb FC SFP+: 10 Gbps fixed
Note: With Fabric OS 9.0 and later, the 4 Gbps port speed is supported only on the F_Port and N_Port port types.
FC port types| F_Port, E_Port, EX_Port (Requires an optional Integrated
Routing License), M_Port (Mirror Port), D_Port (Diagnostic Port)
Data traffic types| Unicast (Class 2 and Class 3), multicast (Class 3 only),
broadcast (Class 3 only)
Classes of service| Class 2, Class 3, Class F (inter-switch frames)
Standard features| Full Fabric mode, Advanced Zoning, Fabric Services, 10 Gb
FC, Adaptive Networking, Advanced Diagnostic Tools, Virtual Fabrics, In-flight
Compression, In-flight Encryption
Optional features| Enterprise Bundle (Inter-Switch Link (ISL) Trunking, Fabric
Vision, Extended Fabric) and Integrated Routing
Note: Model CTO6 comes with the Enterprise Bundle license included
Performance| Non-blocking architecture with wire-speed forwarding of traffic:
- 4GFC: 4.25 Gbit/sec line speed, full duplex 8GFC:
- 8.5 Gbit/sec line speed, full duplex
- 10GFC: 10.51875 Gbit/sec line speed, full duplex
- 16GFC: 14.025 Gbit/sec line speed, full duplex
- 32GFC: 28.05 Gbit/sec line speed, full duplex
- 128GFCp: 4x 28.05 Gbit/sec line speed, full duplex
- Aggregated throughput: 4 Tbps
- Latency for locally switched ports is <780 ns; latency between port groups is 2.6 µs, cut-through routing at 32 Gb/s between locally switched groups. Encryption/compression is 1 µs per node.
Scalability|
- Maximum number of switches in the fabric: 239
- Maximum frame size: 2112-byte payload
- Maximum number of frame buffers per switch: 15,360
- Maximum number of ports per ISL trunk: 8x SFP+ or 2x QSFP+ (Up to 256 Gbps; ISL Trucking license is included in the Enterprise Bundle)
Cooling| Three hot-swap system fan assembly units (two fans in each unit) with
N+1 cooling redundancy. Non-port to port side airflow.
Power supply| Two redundant hot-swap 1500 W AC (100 – 240 V) power supplies
(IEC 320-C14 connector)
Hot-swap parts| SFP+/QSFP+ transceivers, fan assembly units, and power
supplies
Fabric services| Monitoring and Alerting Policy Suite (MAPS); Flow Vision;
Brocade Adaptive Networking (Ingress Rate Limiting, Traffic Isolation, QoS);
Fabric Performance Impact (FPI) Monitoring; Slow Drain Device Quarantine
(SDDQ); Brocade Advanced Zoning (default zoning, port/WWN zoning, broadcast
zoning, peer zoning, target-driven zoning); Dynamic Path Selection (DPS);
Brocade Extended Fabrics; Enhanced BB Credit Recovery; FDMI; Frame
Redirection; Frame- based Trucking; FSPF; Integrated Routing; Brocade ISL
Trunking; Management Server; NPIV; Time Server; Registered State Change
Notification (RSCN); Reliable Commit Service (RCS); Simple Name Server (SNS);
Virtual Fabrics (Logical Switch, Logical Fabric); Read Diagnostics Parameter
(RDP)
Management ports| One 10/100/1000 Mb Ethernet port (UTP, RJ-45); one RS-232
port (RJ-45); one USB port (for additional firmware/log/configuration files
storage)
Supported management software| HTTP, SNMP v1/v3 (FE MIB, FC Management MIB),
SSH; Auditing, Syslog; Brocade Advanced Web Tools; Brocade Network Advisor SAN
Enterprise or Brocade Network Advisor SAN Professional/Professional Plus;
Brocade SANnav Management Portal and SANnav Global View; Command Line
Interface (CLI); SMI-S compliant; trial licenses for add-on capabilities.
Security features| DH-CHAP (between switches and end devices), FCAP switch
authentication; HTTPS, IPsec, IP filtering, LDAP with IPv6, OpenLDAP, Port
Binding, RADIUS, TACACS+, user-defined Role- Based Access Control (RBAC),
Secure Boot, Secure Copy (SCP), Secure RPC, Secure Syslog, SFTP, SSH v2,
SSL, Switch Binding, Trusted Switch. The Brocade G630 Switch provides up to 12
in-flight encryption and compression ports.
Diagnostics| Clear Link optics and cable diagnostics, including
electrical/optical loopback, link traffic/latency/distance; flow mirroring;
built-in flow generator; POST and embedded online/offline diagnostics,
including environmental monitoring, FCping and Pathinfo (FC traceroute), frame
viewer, non-disruptive daemon restart, optics health monitoring, power
monitoring, RAStrace logging, and Rolling Reboot Detection (RRD).
Warranty and support| One-year customer-replaceable unit limited warranty with
9×5 next business day parts delivered. Optional warranty upgrades are
available through Lenovo Services: 9×5 next business day onsite response, 24×7
2-hour or 4-hour onsite response, 24×7 6-hour or 24-hour committed service
repair (available in select countries), up to 5 years of warranty coverage, 1-
year or 2-year post-warranty extensions.
Firmware entitlement| One-year firmware entitlement and support license is
included. Firmware entitlement extension licenses are included in the warranty
upgrades.
Dimensions| Height: 87 mm (3.4 in.); width: 440 mm (17.3 in.); depth: 610 mm
(24.0 in.)
Weight| Empty: 19.05 kg (42.0 lb.); Fully configured: 21.3 kg (47.0 lb.)
Models
The following table lists the Think System DB630S FC SAN Switch models.
Table 2. Lenovo Think System DB630S FC SAN Switch models
Description
| Part number| Machine Type/Model|
Feature code
---|---|---|---
Think System DB630S, 48 ports licensed, 48x 32Gb SWL SFPs, 2 PS, Rail Kit
(1yr)| 7D1SA004WW| 7D1SCTO5WW| BCH6
Think System DB630S, ENT Bundle, 96 ports licensed, 96x 32Gb SWL SFPs, 2 PS,
Rail Kit (1yr)| 7D1SA005WW| 7D1SCTO6WW| BCH7
The DB630S FC SAN Switch models ship with the following items:
- One FC SAN Switch with 1-year firmware entitlement
- Model CTO5: With 48 ports activated and 48x 32 Gb FC SWL SFP+ transceivers included
- Model CTO6: With 96 ports activated and 96x 32 Gb FC SWL SFP+ transceivers included
- Serial cable (DB-9/RJ-45 to RJ-45)
- Rubber feet for setting up the switch as a standalone unit
- Fixed rack mount kit
- Online Documentation web pointer card
- SANnav web pointer card
Note : The switch comes standard without power cords; two power cables must be purchased together with the switch (see Power supplies and cables for details).
Port activation licenses
DB630S Model CTO5 ships with 48 licensed ports and 48x 32 Gb FC SWL SFP+
Transceivers. The remaining 48 SFP+ unlicensed ports can be activated by
purchasing and installing the SFP+ Ports on Demand (POD) licenses that are
available in 24-port increments. DB630S Model CTO6 ships with 96 licensed
ports and 96x 32 Gb FC SWL SFP+ Transceivers.
Eight QSFP+ unlicensed ports on the DB630S FC SAN Switch can be activated by
purchasing and installing the QSFP+ POD license that is available with or
without QSFP+ transceivers.
The following table lists additional POD options for the DB630S FC SAN Switch.
Table 3. POD options
Description
| Part number| Feature code|
Maximum quantity
---|---|---|---
POD bundles with electronic authorization licenses
DB630 24-Port SW License with 24x 32 Gbps SWL SFP+ Transceivers| 4M27A37147|
B6DG| 2
DB630 QSFP+ 32-Port SW License with 8x 128 Gbps (4x 32 Gbps) SWL v2
Transceivers| 4M27A37148| B6DH| 1
Transceivers and cables
With the flexibility of the DB630S FC SAN Switch, customers can choose the following connectivity technologies:
- QSFP+ ports
- For 128 Gb (4x 32 Gb) FC links for connectivity between the DB630S or DB620S FC SAN Switches, customers can use 128 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 128 Gb (4x 32 Gb) FC 2KM LWL QSFP+ optical transceivers can support up to 2 kilometers on single-mode fiber (SMF) cables. The 4x 32 Gb FC links per QSFP+ port can be configured as 128 Gbps parallel FC [round robin 66-bit block distribution across four lanes] or in a 128 Gbps ISL trunk group.
- For 32 Gb FC links, customers can use the 128 Gb (4x 32 Gbps) SWL QSFP+ Transceiver v2 with OM4 MMF MPO-4xLC breakout cables for distances up to 100 meters or OM3 MMF MPO-4xLC breakout cables for distances up to 70 meters.
- For 16 Gb FC links, customers can use 50 µ MMF MPO-4xLC breakout cables for connectivity to other FC SAN switches or routers (E_Port or EX_Port) by using four independent 16 Gb FC links per QSFP+ port (no ISL trunking) with the following transceivers:
- 128 Gb (4x 32 Gb) QSFP+ SWL v2 optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 MMF cables.
- 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 MMF cables.
- SFP+ ports
- For 32 Gb FC links, customers can use 32 Gb FC SFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. For longer distances, the 32 Gb FC LWL SFP+ optical transceivers can support up to 10 km on SMF cables. For extended distances, the 32 Gb FC ELWL SFP+ optical transceivers can support up to 25 kilometers on SMF cables. These transceivers can operate at 32 Gbps, 16 Gbps, or 8 Gbps speeds. (Except ELWL part number 4M27A65431 which can only operate at 32Gbps and 16 Gbps).
- For 16 Gb FC links, customers can use 16 Gb FC SFP+ SWL optical transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables. For longer distances, the 16 Gb FC LWL SFP+ optical transceivers can support up to 10 kilometers on SMF cables. For extended distances, the 16 Gb FC ELWL SFP+ optical transceivers can support up to 25 kilometers on SMF cables. These transceivers can operate at 16 Gbps, 8 Gbps, or 4 Gbps speeds.
- For 10 Gb FC links, customers can use 10 Gb FC SFP+ SWL transceivers for distances up to 550 meters on OM4 or up to 300 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LWL transceivers for distances up to 10 km on SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology (the Extended Fabric feature is NOT required for long distance 10 Gb FC connectivity).
- 1 GbE RJ-45 management port: Customers can use UTP Category 5, 5e, or 6 cables for distances up to 100 meters.
The DB630S FC SAN Switch comes with 48x (Model CTO5) or 96x (Model CTO6) 32 Gb
FC SWL SFP+ transceivers. Additional SWL, LWL, and ELWL SFP+ and SWL and LWL
QSFP+ transceivers can be ordered for the switch, if needed.
The following table lists the supported transceiver and cable options.
Brocade Secure transceivers: These new Secure transceivers have features to ensure that you are using genuine Brocade components to maximize performance and reliability and to help avoid issues related to counterfeit products.
Table 4. Transceivers and cables
Part number
| Feature code| Description|
Maximum quantity
---|---|---|---
QSFP+ transceivers
4M27A65422| BF6G| Brocade Secure 128Gb (4x 32Gb) SWL QSFP+| 8
01KN805| AVGH| Brocade 4x16Gb FC-Compliant SWL QSFP+ Transceiver| 8
32 Gb FC SFP+ transceivers
4M27A65416| BF69| Brocade Secure 32Gb SWL SFP+ Transceiver| 96
4M27A65417| BF6A| Brocade Secure 32Gb SWL SFP+ Transceiver (8-pack)| 12
4M27A65418| BF6B| Brocade Secure 32Gb LWL SFP+ Transceiver| 96
4M27A65419| BF6C| Brocade Secure 32Gb LWL SFP+ Transceiver (8-pack)| 12
4M27A65424| BF6D| Brocade Secure 32Gb ELWL SFP+ (25 km)*| 96
4M27A65431| BQQE| Brocade Secure 32Gb ELWL SFP+ V2 Transceiver (25 km)| 8*
01KN793| AVGD| Brocade 32Gb SWL SFP+ Transceiver (8-pack)| 12
01KN799| AVGF| Brocade 32Gb LWL SFP+ Transceiver (8-pack)| 12
16 Gb FC SFP+ transceivers
4M27A65411| BF64| Brocade Secure 16Gb SWL SFP+| 96
4M27A65412| BF65| Brocade Secure 16Gb SWL SFP+ 8-pack| 12
4M27A65413| BF66| Brocade Secure 16Gb LWL SFP+ (10 km)| 96
4M27A65414| BF67| Brocade Secure 16Gb LWL SFP+ (10 km) 8pk| 12
4M27A65415| BF68| Brocade Secure 16Gb ELWL SFP+ (25 km)| 96
88Y6393| A22R| Brocade 16Gb SWL SFP+ Optical Transceiver| 96
10 Gb FC SFP+ transceivers
4M27A65420| BF6E| Brocade Secure 10Gb FC LWL SFP+| 96
4M27A65421| BF6F| Brocade Secure 10Gb FC SWL SFP+| 96
Optical cables for 128 Gb v2 and 4×16/32 Gb FC SW QSFP+ transceivers
00VX003| AT2U| Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable| 8
00VX005| AT2V| Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable| 8
Optical breakout cables for 128 Gb v2 and 4×16/32 Gb FC SW QSFP+ transceivers
00FM412| A5UA| Lenovo 1m MPO-4xLC OM3 MMF Breakout Cable| 8
00FM413| A5UB| Lenovo 3m MPO-4xLC OM3 MMF Breakout Cable| 8
00FM414| A5UC| Lenovo 5m MPO-4xLC OM3 MMF Breakout Cable| 8
OM3 optical cables for 16 Gb and 32 Gb FC SW SFP+ transceivers
00MN499| ASR5| Lenovo 0.5m LC-LC OM3 MMF Cable| 96
00MN502| ASR6| Lenovo 1m LC-LC OM3 MMF Cable| 96
00MN505| ASR7| Lenovo 3m LC-LC OM3 MMF Cable| 96
00MN508| ASR8| Lenovo 5m LC-LC OM3 MMF Cable| 96
00MN511| ASR9| Lenovo 10m LC-LC OM3 MMF Cable| 96
00MN514| ASRA| Lenovo 15m LC-LC OM3 MMF Cable| 96
00MN517| ASRB| Lenovo 25m LC-LC OM3 MMF Cable| 96
00MN520| ASRC| Lenovo 30m LC-LC OM3 MMF Cable| 96
OM4 optical cables for 16 Gb and 32 Gb FC SW SFP+ transceivers
4Z57A10845| B2P9| Lenovo 0.5m LC-LC OM4 MMF Cable| 96
4Z57A10846| B2PA| Lenovo 1m LC-LC OM4 MMF Cable| 96
4Z57A10847| B2PB| Lenovo 3m LC-LC OM4 MMF Cable| 96
4Z57A10848| B2PC| Lenovo 5m LC-LC OM4 MMF Cable| 96
4Z57A10849| B2PD| Lenovo 10m LC-LC OM4 MMF Cable| 96
4Z57A10850| B2PE| Lenovo 15m LC-LC OM4 MMF Cable| 96
4Z57A10851| B2PF| Lenovo 25m LC-LC OM4 MMF Cable| 96
4Z57A10852| B2PG| Lenovo 30m LC-LC OM4 MMF Cable| 96
UTP Category 6 cables (Green) for the 1 GbE RJ-45 management port
00WE123| AVFW| 0.75m CAT6 Green Cable| 1
00WE127| AVFX| 1.0m CAT6 Green Cable| 1
00WE131| AVFY| 1.25m CAT6 Green Cable| 1
00WE135| AVFZ| 1.5m CAT6 Green Cable| 1
00WE139| AVG0| 3m CAT6 Green Cable| 1
90Y3718| A1MT| 10m CAT6 Green Cable| 1
90Y3727| A1MW| 25m CAT6 Green Cable| 1
UTP Category 5e cables (Blue) for the 1 GbE RJ-45 management port
40K8785| 3802| 1.5m Blue Cat5e Cable| 1
40K5581| 3803| 3m Blue Cat5e Cable| 1
40K8927| 3804| 10m Blue Cat5e Cable| 1
40K8930| 3805| 25m Blue Cat5e Cable| 1
* When using ELW SFP+ transceivers over distances over 10 km, the
Extended Fabric feature that is available in the Enterprise Bundle is required
on a SAN switch to drive the maximum bandwidth over the extended links.
** The specific ELWL only operates at 32 Gbps and 16Gbps. Plus the ELWL
is only supported in 6415- HC7/HC8/HC9 models. The Extended Fabric feature
that is available in the Enterprise or Mainframe Enterprise Bundle is required
on a SAN switch to drive the maximum bandwidth over the extended links.
*** ELWL Requires same optic type/part number on both ends (no-mixing) to
assure interoperability.
The following table lists the cabling requirements for the switch.
Table 5. DB630S FC SAN Switch cabling requirements
Transceiver| Standard| Cable|
Connector
---|---|---|---
32 Gb Fiber Channel
32 Gb FC SWL SFP+ (01KN793, 4M27A65416, 4M27A65417)| FC-PI-6| Up to 30 m with
LC-LC MMF cables supplied by Lenovo (see Table 4).
850 nm 50 µ MMF cable:
- 32GFC: Up to 100 m (OM4) or up to 70 m (OM3).
- 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
- 8GFC: Up to 190 m (OM4) or up to 150 m (OM3).
| LC
32 Gb FC LWL SFP+ (01KN799, 4M27A65418, 4M27A65419)| FC-PI-6| 1310 nm 9 µ SMF
cable:
- 32GFC, 16GFC, 8GFC: Up to 10 km.
| LC
32 Gb FC ELWL SFP+ (4M27A65424, 4M27A65431)| FC-PI-5| 1310 nm 9 µ SMF cable:
- 32GFC: Up to 25 km
| LC
16 Gb Fiber Channel
16 Gb FC SWL SFP+ (88Y6393, 4M27A65411, 4M27A65412)| FC-PI-5| Up to 30 m with
LC-LC MMF cables supplied by Lenovo (see Table 4).
850 nm 50 µ MMF cable:
- 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
- 8GFC: Up to 190 m (OM4) or up to 150 m (OM3).
- 4GFC: Up to 400 m (OM4) or up to 380 m (OM3).
| LC
4x 16 Gb FC SWL QSFP+ (01KN805, 4M27A65413 4M27A65414)| FC-PI-5| Up to 30 m
with MPO-MPO MMF optical cables or up to 5 m with MPO-4xLC optical breakout
cables supplied by Lenovo (see Table 4).
850 nm 50 µ MMF cable:
- 16GFC: Up to 100 m (OM4) or up to 66 m (OM3).
| MPO
16 Gb FC ELWL SFP+ (4M27A65415)| FC-PI-5| 1310 nm 9 µ SMF cable:
- 16GFC: Up to 25 km.
| LC
10 Gb Fiber Channel
10 Gb FC SWL SFP+ (00YH933, 4M27A65421)| FC-10GFC| 850 nm 50 µ MMF cable:
- 10GFC: Up to 550 m (OM4) or up to 300 m (OM3).
| LC
10 Gb FC LWL SFP+ (00YH929, 4M27A65420)| FC-10GFC| 1310 nm 9 µ SMF cable:
- 10GFC: Up to 10 km.
| LC
Management ports
10/100/1000 Mb Ethernet port| 1000BASE-T| Up to 25 m with UTP cables supplied
by Lenovo (see Table 4).
UTP Category 5, 5E, and 6 up to 100 meters.| RJ-45
Enterprise Bundles and Integrated Routing features
For details on the latest features supported with the FC SAN Switch see the
Administration Guide for the latest available Fabric OS version 9.0 and above,
available from:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-
operating-system
The following optional features are available for the DB630S FC SAN Switch:
- Enterprise Bundle
- ISL Trucking (TRK): Allows frame-based consolidation of up to 8 inter-switch links (ISLs) into fault-tolerant and load-balanced trunks with bandwidth of up to 256 Gbps.
- Fabric Vision (FV)
- Monitoring and Alerting Policy Suite (MAPS): Simplifies fabric-wide threshold configuration, monitoring, and alerting with pre-built, rule-based or policy-based templates. Administrators can configure the entire fabric (or multiple fabrics) at one time using common rules and policies, or customize policies for specific ports or switch elements. In addition, administrators can use IO Insight metrics to set thresholds in MAPS policies in order to be notified of application, VM, and storage IOI/O performance degradation.
- Flow Vision: Enables administrators to identify, monitor, and analyze specific application flows in order to simplify troubleshooting, maximize performance, avoid congestion, and optimize resources. Flow Vision includes:
- Flow Monitor: Provides comprehensive visibility, automatic learning, and nondisruptive monitoring of a flow’s performance. Administrators can monitor all flows from a specific host to multiple targets or volumes, from multiple hosts to a specific target/volume, or across a specific ISL. Additionally, they can perform volume-level monitoring of specific frame types to identify resource contention or congestion that is impacting application performance. With the IO Insight capability, administrators can monitor first I/O response time, I/O completion time, the number of pending I/Os, and IOPS metrics for a flow from a specific host to a target or volume running SCSI or NVMe over Fibre Channel traffic. With VM Insight, administrators can monitor network throughput and I/O statistics for each VM.
- Flow Learning: Enables administrators to non-disruptively discover all flows that go to or come from a specific host port or a storage port, or traverse ISLs/IFLs (Inter-Fabric Links) or Fibre Channel over Internet Protocol (FCIP) tunnels, to monitor fabric-wide application performance. In addition, administrators can discover top and bottom bandwidth-consuming devices and manage capacity planning.
- Flow Generator: Provides a built-in traffic generator for pretesting and validating the data center infrastructure for robustness—including route verification and integrity of optics, cables, ports, back-end connections, and ISLs—before deploying applications.
- Flow Mirroring: Enables administrators to non-disruptively create copies of specific application and data flows or frame types that can be captured for indepth analysis.
- VM Insight: Seamlessly monitors health and performance of individual Virtual Machines (VMs) to quickly identify abnormal VM behavior and enable administrators to proactively facilitate troubleshooting and fault isolation, helping to ensure performance and operational stability.
- IO Insight: Proactively monitors I/O performance and behavior to gain deep insight into issues and ensure service levels by non-disruptively and non-intrusively gathering I/O statistics for storage traffic and applying this information within a policy-based monitoring and alerting suite to configure thresholds and alarms.
- Fabric Performance Impact (FPI) Monitoring: Leverages predefined MAPS policies to automatically detect and alert administrators to different latency severity levels, and to identify slow drain devices that could impact network performance. This feature identifies various latency severity levels, pinpointing exactly which devices are causing or are impacted by a bottlenecked port, and quarantines slow drain devices automatically to prevent buffer credit starvation.
- Extended Fabric (EF): Extends Fibre Channel SANs beyond 10 km distance limitations for replication and backup at full bandwidth.
- Integrated Routing: The FC-FC routing service provides Fibre Channel routing between two or more fabrics without merging those fabrics.
The following table lists ordering information for the optional licensed features for the DB630S FC SAN Switch.
Table 6. Optional licensed features (electronic authorization)
Description
| Part number| Feature code|
Maximum quantity
---|---|---|---
Lenovo DB630S Enterprise Bundle (TRK, FV, EF)| 7S0C0019WW| S1PA| 1
Lenovo DB630S Integrated Routing| 7S0C0018WW| S1P9| 1
Configuration note: The DB630S FC SAN Switch Model CTO6 come with the Enterprise Bundle license included.
Firmware entitlement is included with the DB630S FC SAN Switch and provides
1-year firmware support.
The entitlement extensions for additional years of firmware support are
included in the warranty service upgrades and post-warranty extensions.
The Integrated Routing feature (7S0C0018WW) comes with its own 1-year firmware
support entitlement.
The options to extend entitlement for additional years of firmware support for
the Integrated Routing feature are listed in the following table.
Table 7. Firmware support extension options for Integrated Routing
Description
| Part number|
Feature code
---|---|---
Lenovo DB630S Integrated Routing Support Extension, 2-Years| 7S0C001AWW| S1PB
Lenovo DB630S Integrated Routing Support Extension, 4-Years| 7S0C001BWW| S1PC
Management software
Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global
View software license subscriptions that provide comprehensive visibility into
the SAN environment, allow administrators to quickly identify, isolate, and
correct problems, and accelerate administrative tasks by simplifying and
automating workflows.
SANnav Management Portal is a next-generation SAN management application with
a simple browser based user interface (UI) and with a focus on streamlining
common workflows, such as configuration, zoning, deployment, monitoring,
troubleshooting, reporting, and analytics.
Lenovo offers the following SANnav Management Portal subscriptions:
- SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
- SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.
SANnav Management Portal supports all Brocade SAN switches and platforms that
run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510,
DB610S, DB620S, DB400D, DB720S, DB800D, Brocade Directors, and FC5022.
With SANnav Global View, administrators can quickly visualize the health,
performance, and inventory of multiple SANnav Management Portal instances
using a simple, intelligent dashboard and can easily navigate from a global
view down to local environments to investigate points of interest. SANnav
Global View is designed to manage up to 20 SANnav Management Portal instances.
For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-
managementportal#documentation
The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools.
Table 8. SANnav Management Portal and SANnav Global View subscription licenses
Part number
| Feature code|
Description
---|---|---
SANnav Management Portal electronic authorization licenses
7S0C0010WW| S1K6| Brocade SANnav Mgmt Portal Base Edition – 1YR License 600
ports
7S0C0013WW| S1K8| Brocade SANnav Mgmt Portal Base Edition – 3YR License 600
ports
7S0C001KWW| S4MB| Brocade SANnav Mgmt Portal Base Edition – 5YR License 600
ports
7S0C0011WW| S1K7| Brocade SANnav Mgmt Portal Enterprise Edition – 1YR License
15K ports
7S0C0014WW| S1K9| Brocade SANnav Mgmt Portal Enterprise Edition – 3YR License
15K ports
7S0C001LWW| S4MC| Brocade SANnav Mgmt Portal Enterprise Edition – 5YR License
15K ports
SANnav Global View electronic authorization licenses
7S0C0012WW| S1D8| Brocade SANnav Global View – 1YR License
7S0C0015WW| S1D9| Brocade SANnav Global View – 3YR License
7S0C001JWW| S4MA| Brocade SANnav Global View – 5YR License
The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.
Fibre Channel standards
The FC SAN Switch supports the standards listed at the following web page:
https://www.broadcom.com/support/fibre-channel-networking/san-standards
/standards-compliance
Power supplies and cables
The DB630S FC SAN Switch ships with two redundant hot-swap 1500 W AC power
supplies. Each power supply has an IEC 309-C14 connector.
The switch comes standard without a power cord; two rack power cables or line
cords must be ordered together with the switch (see the following table).
Table 9. Power cord options
Description
| Part number|
Feature code
---|---|---
Rack power cables
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 39Y7937| 6201
1.8m, 10A/100-250V, 2xC13PM to IEC 320-C14 Rack Power Cable| None*| 6568
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 4L67A08366| 6311
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable| 39Y7938| 6204
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable| 39Y7932| 6263
Line cords
10A/125V C13 to NEMA 5-15P 4.3m line cord| 39Y7931| 6207
10A/250V C13 to NEMA 6-15P 2.8m line cord| 46M2592| A1RF
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord| 39Y7930| 6222
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord| 39Y7924| 6211
Brazil 10A/125V C13 to NBR 6147 2.8m line cord| 39Y7929| 6223
China 10A/250V C13 to GB 2099.1 2.8m line cord| 39Y7928| 6210
Denmark 10A/250V C13 to DK2-5a 2.8m line cord| 39Y7918| 6213
European 10A/230V C13 to CEE7-VII 2.8m line cord| 39Y7917| 6212
India 10A/250V C13 to IS 6538 2.8m line cord| 39Y7927| 6269
Israel 10A/250V C13 to SI 32 2.8m line cord| 39Y7920| 6218
Italy 10A/250V C13 to CEI 23-16 2.8m line cord| 39Y7921| 6217
Japan 12A/125V C13 to JIS C-8303 2.8m line cord| 46M2593| A1RE
Korea 12A/250V C13 to KETI 2.8m line cord| 39Y7925| 6219
South Africa 10A/250V C13 to SABS 164 2.8m line cord| 39Y7922| 6214
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord| 39Y7919| 6216
Taiwan 10A/250V C13 to CNS 10917-3 2.8m line cord| 00CG265| A53E
Taiwan 15A/125V C13 to CNS 10917-3 2.8m line cord| 00CG267| A53F
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord| 39Y7923| 6215
***** Available for factory-built custom configurations and solutions only.
Rack installation
The DB630S FC SAN Switch comes standard with the fixed rack mount kit that can be used for 4-post rack installations. If needed, the DB630S FC SAN Switch can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kit that is listed in the following table.
Table 10. Rack-mount options
Description
| Part number| Feature code|
Maximum quantity
---|---|---|---
Lenovo Mid-mount Rack Kit| 01KN770| AVG7| 1
The optional mid-mount rack kit for the DB630S FC SAN Switch is shown in the following figure.
Physical specifications
The DB630S FC SAN Switch has the following dimensions and weight (approximate):
- Height: 87 mm (3.4 in.)
- Width: 440 mm (17.3 in.)
- Depth: 610 mm (24.0 in.)
- Weight: 21.31 kg (47.0 lb) with two power supply FRUs, and three fan FRUs without transceivers
Operating environment
The DB630S FC SAN Switch is supported in the following environment:
- Air temperature:
- Operating: 0°C to 40°C (32°F to 104°F)
- Non-operating: -25°C to +70°C (-13°F to 158°F)
- Maximum altitude:
- Operating: 3 000 m (9,842 ft)
- Non-operating: 12 000 m (39,370 ft)
- Humidity:
- Operating: 10% to 85% non-condensing
- Non-operating: 10% to 90% non-condensing
- Electrical power:
- Voltage range: 100 V AC – 240 V AC (nominal)
- Frequency: 50 Hz / 60 Hz (nominal)
- Power consumption:
- Idle: 495 watts
- Typical: 536 watts
- Maximum: 942 watts
- Heat dissipation:
- Idle: 1689 BTU per hour
- Typical: 1829 BTU per hour
- Maximum: 3215 BTU per hour
- Acoustical noise emission: 74.2 dB
Warranty and support
The DB630S FC SAN Switch has a one-year customer-replaceable unit (CRU)
limited warranty with standard call center support during normal business
hours and 9×5 Next Business Day Parts Delivered.
Lenovo’s additional support services provide a sophisticated, unified support
structure for a customer’s data center, with an experience consistently ranked
number one in customer satisfaction worldwide.
The following Lenovo support services are available:
-
Warranty Upgrades (Preconfigured Support) are available to meet the on-site response time targets that match the criticality of customer’s systems:
- 1, 3, or 5 years of warranty service coverage.
- 1-year or 2-year post-warranty extensions.
- Foundation Service: 9×5 service coverage with next business day onsite response.
- Essential Service: 24×7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select regions).
- Advanced Service: 24×7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select regions).
-
Managed Services
Lenovo Managed Services provide continuous 24×7 remote monitoring (plus 24×7 call center availability) and proactive management of a customer’s data center using state of the art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals. Quarterly reviews check error logs, verify firmware and operating system device driver levels, and software as needed. Lenovo will also maintain records of latest patches, critical updates, and firmware levels, to ensure customer’s systems are providing business value through optimized performance. -
Technical Account Management (TAM)
A Lenovo Technical Account Manager helps customers optimize operations of their data centers based on a deep understanding of customer’s business. Customers gain direct access to a Lenovo TAM, who serves as their single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. Also, a TAM helps proactively make service recommendations and manage service relationship with Lenovo to make certain that customer’s needs are met. -
Health Check
Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that customer systems and business are always running at their best. Health Check supports Lenovo- branded server, storage, and networking devices, as well as select Lenovosupported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.
Some regions might have different warranty terms and conditions than the
standard warranty. This is due to local business practices or laws in the
specific region. Local service teams can assist in explaining regions pecific
terms when needed. Examples of region-specific warranty terms are second or
longer business day parts delivery or parts-only base warranty.
If warranty terms and conditions include onsite labor for repair or
replacement of parts, Lenovo will dispatch a service technician to the
customer site to perform the replacement. Onsite labor under base warranty is
limited to labor for replacement of parts that have been determined to be
field-replaceable units (FRUs). Parts that are determined to be customer-
replaceable units (CRUs) do not include onsite labor under base warranty.
If warranty terms include parts-only base warranty, Lenovo is responsible for
delivering only replacement parts that are under base warranty (including
FRUs) that will be sent to a requested location for self-service. Parts-only
service does not include a service technician being dispatched onsite. Parts
must be changed at customer’s own cost and labor and defective parts must be
returned following the instructions supplied with the spare parts.
Lenovo support services are region-specific. Not all support services are
available in every region. For information about Lenovo support services that
are available in a specific region, refer to the following resources:
-
Service part numbers in Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com/#/services -
Lenovo Services Availability Locator
https://lenovolocator.com/
Services
Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Here’s a more in-depth look at what we can do for you:
-
Asset Recovery Services
Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-ewaste-and-grow-your bottom-line- with-lenovo-ars. -
Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company’s environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape -
Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan. -
Basic Hardware Installation
Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. -
Deployment Services
When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks. -
Integration, Migration, and Expansion Services
Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.
Regulatory compliance
The DB630S FC SAN Switch conforms to the following regulations:
- United States: FCC Part 15, Subpart B, Class A; UL 60950-1
- Canada: ICES-003
- European Union:
- CE Mark (EN55032 Class A, IEC/EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
- EN 300 386
- EN 60825
- China: GB4943.1, GB9254
- Japan: VCCI
- Taiwan: BSMI CNS13438, CNS14336-1
- Korea: KN32, KN35
- Australia/New Zealand: AS/NZS CISPR 32, Class A
- Restriction of Hazardous Substances (RoHS)
Interoperability
For end-to-end storage configuration support, refer to the Lenovo Storage
Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get
a list all other supported combinations, with details about supported
hardware, firmware, operating systems, and drivers, plus any additional
configuration notes. View results on screen or export them to Excel.
External storage systems
Lenovo offers the Think System DE Series and Think System DM Series external storage systems for high performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
-
Think System DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide -
Think System DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by
Lenovo that can be used in Lenovo FC SAN solutions.
Note: Information provided in this section is for ordering reference purposes
only. End-to-end LTO Ultrium configuration support for a particular tape
backup unit must be verified through the System Storage Interoperation Center
(SSIC):
http://www.ibm.com/systems/support/storage/ssic
Table 11. External Fiber Channel backup options
Part number
|
Description
---|---
External tape backup libraries
6741A1F| IBM TS4300 3U Tape Library-Base Unit
Fiber Channel backup drives for TS4300 Tape Library – Full Height
01KP938| LTO 7 FH Fiber Channel Drive
01KP954| LTO 8 FH Fiber Channel Drive
02JH837| LTO 9 FH Fiber Channel Drive
Fibre Channel backup drives for TS4300 Tape Library – Full Height
01KP936| LTO 7 HH Fiber Channel Drive
01KP952| LTO 8 HH Fiber Channel Drive
02JH835| LTO 9 HH Fiber Channel Drive
For more information, see the list of Product Guides in the Tape Autoloaders
and Libraries category:
https://lenovopress.com/storage/tape/library
Rack cabinets
The following table lists the supported rack cabinets.
Table 12. Rack cabinets
Part number
|
Description
---|---
93072RX| 25U Standard Rack (1000mm)
93072PX| 25U Static S2 Standard Rack (1000mm)
7D6DA007WW| ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WW| ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
93604PX| 42U 1200mm Deep Dynamic Rack
93614PX| 42U 1200mm Deep Static Rack
93634PX| 42U 1100mm Dynamic Rack
93634EX| 42U 1100mm Dynamic Expansion Rack
93074RX| 42U Standard Rack (1000mm)
7D6EA009WW| Think System 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWW| Think System 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
For specifications about these racks, see the Lenovo Rack Cabinet Reference,
available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets
category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Table 13. Power distribution units
Part number
| Feature code| Description| ANZ| ASEAN| Brazil| EET| MEA| RUCIS| WE| HTK| INDIA| JAPAN| LA| NA|
PRC
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
0U Basic PDUs
00YJ776| ATZY| 0U 36 C13/6 C19 24A 1 Phase PDU| N| Y| Y| N| N| N| N| N| N| Y|
Y| Y| N
00YJ777| ATZZ| 0U 36 C13/6 C19 32A 1 Phase PDU| Y| Y| N| Y| Y| Y| Y| Y| Y| N|
N| Y| Y
00YJ778| AU00| 0U 21 C13/12 C19 32A 3 Phase PDU| Y| Y| N| Y| Y| Y| Y| Y| Y| N|
N| Y| Y
0U Switched and Monitored PDUs
00YJ783| AU04| 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU| N| N|
Y| N| N| N| Y| N| N| Y| Y| Y| N
00YJ781| AU03| 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU| N| N|
Y| N| Y| N| Y| N| N| Y| Y| Y| N
00YJ782| AU02| 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU| Y| Y|
Y| Y| Y| Y| Y| Y| Y| N| Y| N| Y
00YJ780| AU01| 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU| Y| Y|
Y| Y| Y| Y| Y| Y| Y| N| Y| N| Y
1U Switched and Monitored PDUs
4PU7A81117| BNDV| 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU – ETL|
N| N| N| N| N| N| N| N| N| N| N| Y| N
4PU7A77467| BLC4| 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU| N| N|
N| N| N| N| N| N| N| Y| N| Y| N
4PU7A77469| BLC6| 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU| N| N|
N| N| N| N| N| N| N| N| N| Y| N
4PU7A77468| BLC5| 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU| Y| Y|
Y| Y| Y| Y| Y| Y| Y| N| Y| Y| Y
4PU7A81118| BNDW| 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU – CE| Y|
Y| Y| Y| Y| Y| Y| Y| Y| N| Y| N| Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19
outlets)
71763NU| 6051| Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH| N| N| Y| N|
N| N| N| N| N| Y| Y| Y| N
71762NX| 6091| Ultra Density Enterprise C19/C13 PDU Module| Y| Y| Y| Y| Y| Y|
Y| Y| Y| Y| Y| Y| Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816| 6030| DPI C13 Enterprise PDU Plus Module (WW)| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y| Y| Y| Y
39Y8941| 6010| DPI C13 Enterprise PDU Module (WW)| Y| Y| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y| Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948| 6060| DPI C19 Enterprise PDU Module (WW)| Y| Y| Y| Y| Y| Y| Y| Y| Y|
Y| Y| Y| Y
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938| 6002| DPI Single-phase 30A/120V Front-end PDU (US)| Y| Y| Y| Y| Y| Y|
Y| Y| Y| Y| Y| Y| Y
39Y8939| 6003| DPI Single-phase 30A/208V Front-end PDU (US)| Y| Y| Y| Y| Y| Y|
Y| Y| Y| Y| Y| Y| Y
39Y8934| 6005| DPI Single-phase 32A/230V Front-end PDU (International)| Y| Y|
Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
39Y8940| 6004| DPI Single-phase 60A/208V Front-end PDU (US)| Y| N| Y| Y| Y| Y|
Y| N| N| Y| Y| Y| N
39Y8935| 6006| DPI Single-phase 63A/230V Front-end PDU (International)| Y| Y|
Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905| 5900| DPI 100-127V NEMA PDU| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
Line cords for 1U PDUs that ship without a line cord
40K9611| 6504| 4.3m, 32A/380-415V, EPDU/IEC 309
3P+N+G 3ph wye (non-US) Line Cord
| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
40K9612| 6502| 4.3m, 32A/230V, EPDU to IEC 309 P+N+G
(non-US) Line Cord
| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
40K9613| 6503| 4.3m, 63A/230V, EPDU to IEC 309 P+N+G
(non-US) Line Cord
| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
40K9614| 6500| 4.3m, 30A/208V, EPDU to NEMA L6-30P
(US) Line Cord
| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
40K9615| 6501| 4.3m, 60A/208V, EPDU to IEC 309 2P+G
(US) Line Cord
| N| N| Y| N| N| N| Y| N| N| Y| Y| Y| N
40K9617| 6505| 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line
Cord| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
40K9618| 6506| 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line
Cord| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y| Y
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Table 14. Uninterruptible power supply units
Part number|
Description
---|---
55941AX| RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX| RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX| RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX| RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX| RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX| RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX| RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX| RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX| RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX| RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX| RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX| RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT†| Think System RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB
10A, 1x C19 16A outlets)
55943LT†| Think System RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x
GB 10A, 1x C19 16A outlets)
55946KT†| Think System RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x
Terminal Block output)
5594XKT†| Think System RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x
Terminal Block output)
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Related publications and links
For more information, see the following resources:
-
Interactive 3D Tour for the DB630S:
https://lenovopress.com/LP1186 -
Lenovo ThinkSystem DB630S FC SAN Switch product publications
http://datacentersupport.lenovo.com- Hardware Installation Guide
- Fabric OS Administration Guide
- Fabric OS Extension Configuration Guide
- Fabric OS Troubleshooting and Diagnostics Guide
- Fabric OS Command Reference
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Web Tools Administration Guide
- Flow Vision Configuration Guide
- Monitoring and Alerting Policy Suite Configuration Guide
-
Lenovo Data Center Support for the ThinkSystem DB630S FC SAN Switch:
http://datacentersupport.lenovo.com -
Benefits of an End-to-End NVMe over FC Solution with Lenovo ThinkSystem
http://lenovopress.com/lp0955
Related product families
Product families related to this document are the following:
- Rack SAN Switches
- DB Series SAN Switches
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, LP1090, was created or updated on October 13, 2022.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/LP1090 -
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/LP1090.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
Lenovo Services
ThinkSystem
The following terms are trademarks of other companies:
Excel® is a trademark of Microsoft Corporation in the United States, other
countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
References
- Home - Data Center Support - Lenovo Support US
- DCSC - Data Center Solution Configurator
- Benefits of an End-to-End NVMe over FC Solution with Lenovo ThinkSystem > Lenovo Press
- Lenovo Statement of Limited Warranty for Data Center Group (DCG) Servers, System Storage and Networking - Lenovo Support US
- Lenovo Infrastructure Solutions Group Services Agreement - Lenovo Support US
- SANnav Management Portal
- IBM System Storage Interoperation Center (SSIC)
- Lenovo Storage Interoperation Center (LSIC) - Lenovo Support US
- Services Availability Locator
- 3D Tour: ThinkSystem DB630S 32Gb FC SAN Switch Interactive 3D Tour > Lenovo Press
- Tape Autoloaders and Libraries > Lenovo Press
- DE Series Storage > Lenovo Press
- DM Series Storage > Lenovo Press
- Lenovo ThinkSystem DB630S 32Gb FC SAN Switch Product Guide > Lenovo Press
- Rack SAN Switches > Lenovo Press
- DB Series SAN Switches > Lenovo Press
- Fabric Operating System (FOS)
- Standards Compliance
- Lenovo Official US Site | Laptops, PCs, Tablets & Servers | Lenovo US
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>