healthsmart 40-685-00 Mist XP Humidifier Instruction Manual
- June 7, 2024
- healthsmart
Table of Contents
healthsmart 40-685-00 Mist XP Humidifier Instruction Manual
**KEY TO SYMBOLS
**
**
**
**
**
- Mist Output Opening
- Water Tank
- Tank Cap
- Base
- Reservoir
- Nightlight
- Power Knob / Adjustable Mist Knob
- Ultrasonic Transducer
- Air Outlet
- Water Valve
IMPORTANT SAFETY INSTRUCTIONS
-
After removing all packaging materials, ensure that the humidifier has not been damaged during transportation.
-
To avoid injury, do not leave any packaging materials (plastic bags, cardboard
boxes, etc.) within the reach of children. -
Before connecting the equipment, ensure that the rated voltage (120 V)
corresponds to the main voltage supply of the electrical outlet. -
To avoid risk of fire, shock, or injury, do not use additional power strip adapters
and/or extension cords. -
Only place the humidifier on flat, stable surfaces.
-
Only use clean, cool, tap, filtered or distilled water to fill water tank.
Do not use hot water. Do not add salt, fragrance/essential oils, medication, or descaling tablets to water. -
Do not operate on wood or other water-sensitive surfaces, as condensation may occur.
-
Do not leave humidifier unattended in a closed room during use, as the air could become too saturated and leave condensation on furniture or walls.
-
Always disconnect the equipment from the power outlet when left unattended or not in use.
-
Before performing any cleaning or maintenance, disconnect the equipment from the power outlet.
-
This product is not a toy. Keep out of reach of children.
-
This equipment is a household humidifier, for indoor use only. Do not operate outdoors.
-
Do not use accessories, spare parts, or any component not supplied or approved by the manufacturer.
-
Never touch the equipment with wet or damp hands.
-
Do not move, tilt, or tip humidifier during use; doing so may cause water leakage.
-
If equipment is damaged and/or not working properly, turn the unit off by disconnecting the plug from the power outlet.
-
Never submerge the equipment in water or any other liquid.
-
Do not touch the equipment if it accidentally falls into the water.
-
Do not direct vapor flow towards furniture or electrical appliances.
-
Do not touch the ultrasonic transducer with your hands or tools while the unit is plugged in.
-
Do not operate the humidifier without water.
-
Do not attempt to empty or fill the tank while the unit is plugged in.
-
Clean and dry the humidifier at the end of every operating cycle.
-
Dispose of any worn accessories and/or the equipment at an appropriate collection point, as required by state regulations.
HOW TO PREPARE AND USE THE EQUIPMENT
- Check that the equipment is completely clean, the power knob is in the OFF position, and that the power cord is not connected to the power outlet.
- Gently remove the water tank from the base.
- Unscrew the cap on the underside of the tank. Fill the water tank leaving approximately ¼” of space from the rim when the tank is upside down.
- Do not fill water all the way to the rim.
- Screw the cap back on and fit the water tank, right side up, back into the base of the unit, making sure it is properly secured in place.
- Connect the equipment to a power outlet.
- Use the mist regulation knob to turn the unit ON by moving the knob clockwise.
- The night light illuminates when the unit is ON and vapor will start to exit.
- Use the mist regulation knob to control the amount of vapor flow desired.
- To turn the unit OFF, turn the knob counterclockwise. The night light will turn off when the unit is OFF.
- When the water tank is empty, the humidifier stops automatically.
CLEANING AND MAINTENANCE
- Before cleaning the equipment, always turn the humidifier OFF and disconnect the plug from the power outlet.
- Do not place the humidifier directly under running water.
- Do not wet the power cable or air outlet.
- Do not scrape the ultrasonic transducer with metallic materials, tools or objects.
- Do not leave water in the water tank when the equipment is not in use.
Daily Cleaning:
- Remove water tank from the base, unscrew the cap, and pour out all remaining water.
- Clean the tank, reservoir, and transducer of the humidifier with a soft, clean cloth and dry thoroughly.
- Dry all parts thoroughly before storage.
Weekly Cleaning:
- Remove water tank from the base, unscrew the cap, and pour out all remaining water.
- Pour a water solution prepared with 50% white vinegar into the water tank.
- Screw the cap back on and fit the water tank, right side up, back into the base of the unit, making sure it is properly secured in place.
- Leave to soak for at least 4 hours (overnight is ideal). Do not turn the humidifier on or run the unit with the water/white vinegar cleaning solution.
- Remove the water tank and cap to pour out all of the water/white vinegar solution, and rinse the tank with cool, clean water.
- Wipe the tank, reservoir, and transducer of the humidifier with a soft, clean cloth and dry thoroughly.
- Clean the outer surfaces of the humidifier with a soft, damp cloth.
- Do not use abrasive products, alcohol, solvents, or similar products which may cause permanent damage to the outer surface.
TROUBLESHOOTING
Problem
| Solution
---|---
If the humidifier does not work
|
- Check that the plug is connected correctly.
- Check that the switch is in the ON position.
- Check that there is sufficient water in the water tank.
- Check that the water tank is properly in place and secured
If the power button is in the ON position but there is no vapor flow|
- Check whether there are hard water deposits on the ultrasonic transducer.
- Check whether there is sufficient water in the water tank.
Strange odor|
- Clean the water tank and the reservoir with water/white vinegar solution, then rinse with clean water.
- Aerate the water tank in a cool place for 12 hours.
TECHNICAL SPECIFICATIONS
Run Time: Min. setting run time up to 24 hours / Max. setting run time up
to 10 hours
Tank Capacity: 0.66 gal.
Ideal Room Size: Medium to Large
*Average Humidity Output: 7.1 fl. oz./hr
Power Consumption: 120V, 60Hz, 22W
Sound Level:** <35 dBA
*Humidity output may vary based on indoor room temperature, humidity, and mist output setting.
LIMITED THREE-YEAR WARRANTY
This warranty covers only normal use, and does not apply for use in any
clinical or commercial applications. This warranty does not cover batteries or
other power sources that may be provided with or used with the humidifier. The
warranty is voided if the humidifier product is misused or abused in any
manner.
If the humidifier fails to operate during the first 3 years from the time
originally purchased, please call our Customer Care Help Line at
800-622-4714 and we will try to resolve
the issue as soon as possible. If the warrantor determines the unit failed to
operate due to a manufacturing defect, the unit will be replaced at the option
of the warrantor. The purchaser will be responsible for the prepaid postage
along with $9.99 to cover return shipping and insurance. The purchaser must
return the original humidifier prior to a replacement product being provided.
Replacement of the product is the only remedy covered by the Limited 3-Year
Warranty.
This warranty gives you specific legal rights, which vary from state to state.
To be eligible for the warranty, please register your product online within 10
days of purchase date at
www.LiveHealthSmart.com.
We make no other express or implied warranties, arising by operation of law or otherwise, or any warranty of merchantability or fitness for a particular use or purpose whether or not the use or purpose has been disclosed to the warrantor in specifications, drawings, or otherwise, and whether or not the warrantor’s products are specifically designed and/or manufactured by the warrantor for the buyer’s use or purposes, except for the limited warranty stated above. The warrantor will not be responsible for any indirect, incidental, special, consequential, or punitive damages or other loss, including, but not limited to, damage to or loss of other property or equipment and personal injuries, whether to purchaser or others. The warrantor shall in no event be liable to the purchaser for any amount in excess of the cost to replace the product.
CONFORMS TO UL STD 998 CERTIFIED TO CSA STD. C22.2 NO. 104
This product has been tested and complies with the requirements for Federal Communications Commission, Part 18 for Radio/TV/Communication interference. Although tested, it may affect these devices. If the humidifier is found to interfere, separate the device and/or the humidifier. Conduct only the user maintenance found in this manual. Other maintenance and servicing can cause harmful interference and can void the required FCC compliance.