FEIT UCL18FP Flat Panel Under Cabinet Light Installation Guide
- June 7, 2024
- Feit
Table of Contents
FEIT UCL18FP Flat Panel Under Cabinet Light
IMPORTANT SAFEGUARDS
ALWAYS FOLLOW BASIC SAFETY PRECAUTIONS WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT.
|
CAUTION : Do not attempt to install while plugged in. This .. fixture is
for indoor use only. Not for use with plastic cabinets.
Do not install this fixture inside a totally enclosed cabinet.
Do not mount over stoves.
---|---
| WARNING : To avoid risk of electrical shock, always make l,ll sure the
product is unplugged from the electrical outlet before assembling,
disassembling, relocating, servicing or cleaning it.
|
CAUTION : Do not install this product in a wet location.
|
CAUTION : Do not install this product in an outdoor location.
|
CAUTION : Do not use chemical solvents or harsh abrasives to clean the
fixture.
Supplier’s Declaration of Conformity:
47 CFR § 2.1077 Compliance Information
Responsible Party: Feit Electric Company 4901 Gregg Road, Pico Rivera, CA
90660, USA562-463-2852
Unique Identifier: UCL 18FP/5CCTCAG2
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Note: This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver. Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. Consult the dealer or an experienced radionv technician
for help. Any changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate the equipment. CAN
ICES-00S(B)
Limited Warranty
This product is warrantied to be free from defects in workmanship and materials for up to 5 years from date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact-us or call 1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
Pre-Assembly
TOOLS REQUIRED
PHILLIPS SCREWDRIVER
|
FLAT HEAD SCREWDRIVER
|
PENCIL
|
PLIERS WRENCH
|
18 AWG WIRE STRIPPER
---|---|---|---|---
HARDWARE INCLUDED
| NOTE: Hardware not shown to actual size.
---|---
|
|
---|---|---
|
|
|
|
Part| Description|
Quantity
---|---|---
AA
| 18 in. LED Flat Panel Fixture|
1
BB
| 18 in. Linking Cable|
1
CC
| Mounting Screws|
2
DD
| Fixture Mounting Template|
1
EE
| Hardwire Bracket|
1
FF
| Hardwire Bracket Screw|
1
GG
| Wire Nut|
3
HH
| Clamp Connector|
1
II
| 18 AWG Wire (Green Ground Wire)|
1
Item No.
| Description| Volts (V)| Wattage Per Fixture (W)| Input Current (mA)| Maximum Linkable Units at 120V|
Maximum Linkable Units with In-Wall Dimmer
---|---|---|---|---|---|---
UCL18FP/5CCTCAG2
| 18 Inch Flat Panel Under Cabinet LED Fixture| 120| 15| 180| 55|
7
LIGHTING DISTRIBUTION
Distance
| Center Beam (Foot Candles)|
Beam Diameter
3 ft
5 ft
8 ft
15 ft
| 54
19
7.6
2.2
|
7.2 ft
12 ft
19 ft
36 ft
Beam Spread:
|
100º
---|---
CD @ CB:
|
486
Single LED Fixture Hardwire Installation
-
Turn Off the Power
Turn the power OFF from the breaker panel before starting installation.
-
Position the Fixture
Find the desired place for the LED light fixture and mark clearly using the provided mounting bracket template (DD).
-
Installing the Mounting Screws
Screw in the Mounting Screws (CC) on the marked locations, leaving a gap of 0.08-0.1 O inches between the screw head J and the instillation surface.
-
Removing the Hardwire Bracket
Remove the screw on the hardwire bracket, then slide and lift the bracket off of the fixture.
-
Removing the Knock-out
Carefully remove the knock-out with a flathead screwdriver.
-
Installing the Clamp Connector to the Knockout Hole
Install the Clamp Connector (HH) to the knock-out hole by inserting it through the hole and securing it with the nut. The Clamp Connector (HH) should be on the outer side of the bracket.
-
Cutting and Stripping Wires
Take out of the black and white 18 AWG wires in the fixture and the green 18 AWG wire (II) in the plastic bag. Cut and strip the wires to the correct length. -
Wire Power Supply to the Fixture
Feed the supply wire through the Clamp Connector (HH) and knockout hole and make all connections using the wire nuts provided. Connect the 120V line (black) wire to the black wire. Connect the neutral (white) wire to the white wire. Connect the ground (green) wire to the green wire. -
Replace the Wiring Bracket
After connecting the wires correctly, place the wires inside the fixture and reinsert the bracket, sliding it over and screwing it secure
-
Secure Supply Wires with the Clamp Connector
Secure the supply wire by firmly screwing the clamp connectors down on the wire.
-
Installing LED Fixture
Align holes on the back of the fixture to the heads of the Mounting Screws. Slide fixture towards the mounting slot. If the fixture is not snug, remove the fixture and readjust the screws.
-
Linking LED Fixtures
Connect the LED Fixtures (AA) using the provided Linking Cable (BB).
| NOTE: To install 2 or more LED fixtures, repeat the single fixture installation instructions with two or more units.
---|---
Alternative Plug-In Installation (Electrical Plug not Included)
-
Position the Fixtures
Find the desired place for the LED light fixture and mark clearly using the provided mounting bracket template (DD).
-
Installing the Mounting Screws
Screw in the Mounting Screws (CC) on the marked locations, leaving a gap of 0.08-0.1 0 inches between the screw head and the installation surface.
-
Installing LED Fixture
Align holes on the back of the fixture to the heads of the Mounting Screws. Slide fixture forwards to secure into place. If the fixture is not snug, remove the fixture and readjust the screws.
-
Connecting the Power Supply
Plug In Electrical Plug to the LED Fixture (AA).
| NOTE: The electrical plug can be connected to either side of the LED Fixture (AA).
---|--- -
Connecting to a Power Outlet
Connect the Electrical Plug to the power outlet on the wall.
Operating Instructions
Use the ON/OFF and Dim Button for ON/OFF Operation and to Change the Dimming Levels
- To select the desired dimming level, cycle through the dimming levels (High, Medium, Low, Dim, Off) by pressing the Dim Button. This setting will be fixed each time the ON/OFF switch is turned ON.
Changing the Color Temperature Setting
- To select the desired color temperature, cycle through 27OOK – 3OOOK – 35OOK – 4OOOK – 5OOOK by pressing the CCT Button. This setting will be fixed each time the ON/OFF switch is turned ON.
This LED Fixture has the feature to operate and control multiple units, even if they are not linked.
- To control multiple fixtures, Hold the CCT button for 3 seconds on all the fixtures to be controlled in a group.
- To remove the individual fixture from the group, Hold the CCT button on the fixture that you want to control individually for 3 seconds.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>