Honeywell T6R-HW Wireless Smart Thermostat Installation Guide
- June 7, 2024
- Honeywell
Table of Contents
Honeywell T6R-HW Wireless Smart Thermostat
T6R-HW SMART THERMOSTAT
Compatible with Sundial Y- and S-plan stored hot water systems with zone
valves. Also compatible with 24-230V on/off appliances such as gas boilers,
combi-boilers an heat pump.
Need help? For assistance please visit: getconnected.honeywellhome.com
Resideo, 200 Berkshire Place, Winnersh Triangle, Berkshire RG41 5R
Phone: 0300 130 1299
Approvals
Hereby, Pittway Sarl declares that the radio equipment type T6R-HW is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
https://hwllhome.co/DoC
RF (868MHz): Receiver Category 2, Max RF Power 25mW, 868–868.6MHz
(868.3MHz)
Wi-Fi (2.4GHz): Max Power 100mW, 2.4–2.458GHz
ErP: Class V (+3%), (EU) 811/2013
Must be installed by a competent person!
Read these instructions carefully. Failure to follow these instructions can
damage the product or cause a hazardous condition.
Turn OFF the power and remove the old thermostat
To ensure your safety, always make sure mains power is switched OFF before
accessing wiring.
In case of removing the old thermostat be aware that the existing wiring will
no longer be used
The T6R-HW thermostat should not be placed near draughts, in direct sunlight or near heat sources.
WEEE Directive 2012/19/EC
Waste Electrical and Electronic Equipment directive
At the end of the product life dispose of the packaging and product in a
corresponding recycling centre. Do not dispose of the unit with the usual
domestic refuse. Do not burn the product.
Prepare Receiver Box for installation
Before installation of the Receiver Box
Find a suitable location near to the boiler. Leave at least 30cm distance from
any metal objects including wallboxes and boiler housing.
Loosen the front screw to remove cover or tighten it when the cover is back in place.
Needed during installation:
- Cable with 2 wires from the boiler to Receiver Box.
- The Receiver Box requires 230V power
Install the Receiver Box
Wall box or Rear Wiring
Hinge open the terminal block flap to access the cables and wall box screw
holes.
Surface wiring
Use the cable clamps to secure the surface wiring.
Replace the cover
Locate the hinges at the top of the cover and wall plate, close the cover and
secure with the screw.
Install the T6 thermostat
Choose the appropriate plug.
Place the thermostat on an even, horizontal surface and plug it in.
Complete installation
Turn ON mains power to the Heating Appliance and Receiver Box.
No binding needed, Receiver Box and Thermostat are pre-bound.
To rebind the units, reset the Receiver box, then press the button for 3
seconds.
The LED on the receiver box will blink yellow to indicate the box is in
binding mode. On the thermostat press for 5 seconds to enter the advanced
menu.
Navigate to Binding, clear the current binding then bind the device again.
Set Up and configuratio
Once setup is completed, if you need to change more settings go to the advanced menu. To access the advanced menu press for 5 seconds.
In the advanced menu the following settings can be adjusted:
Wiring Diagrams
For other wiring diagrams visit:
https://hwllhome.co/uk-wiring
Pittway Sarl, Z.A. La Pièce 4, 1180 Rolle, Switzerland
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell
International Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
References
- Software & Apps for Smart Home | Resideo UK
- hwllhome.co/DoC
- Wiring Diagrams - Honeywell Home Heating Controls