Tip : A wrong operation can cause a inaccurate measurement result, the correct measured distance is 1-5 cm to forehead (between the eyebrows). July 2020 VER.1.0
Introduction
Your new non-contact forehead thermometer uses advanced infrared (IR)
technology to measure temperature instantly and accurately on the forehead or
object.
Easy to use and less measurement time. This thermometer does not need to
contact body or object to ensure the safety and hygiene. Its ergonomic design
makes this thermometer be simple and very easy to check the temperature. It
only takes 1 second to take measurement and reading.
Body and object modes
This thermometer supports to measure temperature of body and object. Measuring
range of object mode is 0.0 to 100.0 °C(32.0 °F~212.0 °F).That mean s except
to take body temperature, it also supports to take the surface temperature of
object as below, .Surface temperature of milk in the bottle .Surface
temperature of baby bath .Environment temperature
Alarm sounds when body temperature is over 38.5 °C, an alarm sounds for 3
times.
Memory function
It stores up to 1 sets recent measurement data.
Auto power off
Automatically power off if left idle for 30 seconds .
Measurement
Measurement time interval in 15s and the measurement distance is within 1-5
cm.
Please read the manual carefully before you use the unit, and keep for future reference
Safety Information
This thermometer is not intended to substitute for a consultation with your
physician. The forehead scan temperature serves as a reference only. It cannot
be a judgment on fever.
Basic safety precautions should always be observed,especially when the
thermometer is used on or near children and disabled persons.
Please place the device unreachable by young.
Avoid direct sunlight.
Do not touch the lens.
No modification of this device is allowed.
The swallowing of small parks like packing bag, battery, battery cover and so
on may cause the suffocation.
Please do not use a dilution agent, alcohol or petrol to clean the unit.
Please treat is gently and prevent the falling from a high place.
Please do not immersed it in liquid.
Never leave battery in the battery compartment fora long time without use, as
they may leak and cause damage to the unit.
Please take off the battery if you do not intend to use within 3 months.
Replace with new batteries if the unit display a low battery symbol.
Do not mix the old and new batteries together.
This article is not for professional usage.
To ensure the correct use of the product, basic safety measures should always be followed including the warning and the caution symbols listed in the instruction manual :
Symbol descriptions
The following symbols may appear in this manual, on the label, on the device,
or on its accessories. Some of the symbols represent standards and compliance
associated with the device and its use.
| WARNING :This alert identifies hazards that may cause serious personal
injury or death .
| CAUT ION :This alert identifies hazards that may cause minor personal
injury, product damage, or property damage.
| Type BF applied part
| Manufacturer
| Specifies serial numbe
| DISPOSAL : Do not dispose this product as unsorted municipal waste.
Collection of such wast e separately for special treatment is necessary.
| Direct current
| Operating instructions
| Consult accompanying documents
WARNING
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact you local government for information
regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
Classification
- Internally powered equipment;
- Type BF applied part;
- Protection against ingress of water: IPX0;
- Not category AP/APG equipment ;
- Mode of operation : Continuous operation ;
Note : the user must check that the equipment functions safely and ensure that it is in proper working condition before it being used.
Product structure
Body
- Display screen
- Mode switch
- Sensor probe 1
- Down (-) button
- Up (+) button
- Setting button
- START/STOP button
- Battery cover
Display
- Object temperature indicator
- Body temperature indicator
- Temperature unit
- Memory mode
- Low battery indicator
- Sound indicator
- Temperature reading
Battery Installation
-
Remove the battery cover from the battery compartment as the arrow direction accordingly.
-
Insert 2 pcs 1.5 V AAA size alkaline batteries, and ensure each battery is in the proper direction.Close the battery cover.
Low battery and replacement
During power on, the low battery symbol will display once the unit starts to
work, and you should replace with new batteries, otherwise the unit can not
work.
Battery type and replacement
Please use 2 pcs of AAA identical 1.5V alkaline batteries. Do not use the
batteries beyond their expiry date . Please remove the batteries if you do not
need to use for long time .
WARNING
Dispose the battery in accordance with all federal, state and local laws .To
avoid fire and explosion hazard, do not burn or incinerate the battery.
Setting
How to set
Display | Function | Description |
---|
F-1
| Unit selection| Toggle between Unit °C and °F
F-2
| Turn On/Off the alarm sound| With “OPEN” on the screen means the sound is on With “CLOS” on the screen means the sound is off
Use of the unit
Pre-measurement
About normal body temperature & fever the temperature in the forehead and
temple area differs from the internal temperature, which is taken orally or
rectally. Vasoconstriction, an effect which constricts the blood vessels and
cools the skin, can occur during the early stages of a fever. In this case,
the temperature measured by the non-contact thermometer may be unusually low.
If the measurement therefore does not match the patients own perception or is
unusually low, repeat the measurement every 15 minutes. As a reference, you
can also measure the internal body temperature using a conventional oral or
rectal thermometer.
Body temperature can vary from one individual/person to next. It also varies by location on the body and time of day. Below shows the statistical normal ranges from different sites.
Please keep in mind that temperatures measured from different
sites, even at the same time, should not be directly compared. Fever indicates
that the body temperature is higher than normal. This
symptom may be caused by infection, overdressing or immunization. Some people
may not experience fever even when they are ill.
These include, but are not limited to, infants younger than 3 months old, persons with compromised immune systems, persons taking antibiotics, steroids or antipyretics (aspirin, ibuprofen, acetaminophen), or persons with certain chronic illnesses. Please consult your physician when you feel ill even if you do not have fever.
*Table 1 Body Site Normal Temperature Range**
Body site | Normal temperature range |
---|---|
Oral | 0.6°C (1°F) or more |
Rectal/ear | 0.3°C to 0.6 °C (0.5 °F to 1°F) higher than oral temperature |
Axillary (armpit) | 0.3°C to 0.6°C(0.5°F to 1°F) lower than oral temperature |
Measuring procedure
As a body thermometer
-
Select body mode , the temperature unit will appear. (Picture at right)
-
Move the probe close to the forehead, make sure the probe is flat and take measurement with a distance within 1-5 cm.Press Start/Stop button.
-
The measurement will be finished in 1 seconds, when it has been completed, you can hear 3 short beeps, at the same time, the reading will appear on the display.
Note:
-
If the reading is <37.5°C(99.5°F) and 32°C(89.6°F) the display
will show with green backlight. -
If the reading is between value 37.5-38.5°C(99.5-101.3°F), the display will show together with 1 short beeps, the orange backlight lasts for alarm.
-
If the reading is above value 38.5°C(109.4°F), the display will show together with 3 short beeps, the red backlight lasts for alarm.
-
As the forehead measurement temperature is likely to be affected by sweat, oil and the surroundings, the reading shall be taken as a reference only.
-
If the probe is placed at an angle close to the forehead measurement, the reading will be affected by surrounding temperature.
-
Babies’ skin reacts very quickly in the ambient temperature. Therefore, do not take their temperature with the non-contact thermometer during/after breastfeeding, because the skin temperature maybe lower than the internal body temperature.
-
The thermometer will automatically turn off if left idle for 30 seconds.
Measuring procedure
As a object thermometer
-
Select Object Mode, the temperature unit will appear. (Picture at right)
-
Move the probe close to the object, make sure the probe is flat and take measurement with a distance within 1-5cm. Press the Start/Stop button to take measurement
-
The measurement will be finished in 1 seconds, when it has been completed, you can hear 3 short beeps, at the same time, the reading will appear on the display
Note :
- As the object scan temperature is likely to be affected by the surroundings, the reading shall be taken as a reference only.
- If the probe is placed at an angle close the object scan, the reading will be affected by surrounding temperature.
- The thermometer will automatically turn off if left idle for 30 seconds.
Troubleshoot
Error indicators
The following symbols will appear on the display when measurement is abnormal
Symbol
|
Correction
---|---
| In body mode. Measured temperature is above measuring range of
43.0°C(109.4°F)
It is shown on the LCD with red LED.
| In body mode. Measured temperature is bellow Measuring Range of <32°C/89,6°F
It is shown on the LCD with red LED.
| In object mode. Measured temperature is above measuring range of 100°C/212°F or environmental temperature is above system operating range 40°C/104°F
It is shown on the LCD with red LED.
| In object mode. Measured temperature is below measuring range of <0.0°C/32,0°F
Or environmental temperature is below system operating range <5°C/41°F
It is shown on the LCD with red LED.
| If low battery indicator appears, replace all batteries with new ones.
ERR
| Thermometer sytem fails or affected by electric magnetic field.
Care and maintenance
Care for the main unit
- Keep the unit in the storage case when not in use.
- Clean the unit with a soft dry cloth. Do not use any abrasive or volatile cleaners.
- Never immerse the unit or any of its component in water.
Maintenance
Do not clean the unit with naphtha, thinner or gasoline etc.| Store the unit
in a clean and dry location. Do not subject the unit to extreme hot or cold
temperature, humidity and direct sunlight.
---|---
|
Remove the batteries if the unit will not be used in 3 months or longer.| Do
not use the unit under the influence of electromagnetic interference (nearby
cellphones, microwave etc.)
|
Note : We will not be responsible for any quality problem if you do not care and maintain the product as instructed.
Specification
Description | Non-con tact Infrared Thermometer |
---|---|
Display | LCD digital display |
Measuring localization | Forehead and object surface |
Measurement range | Body mode 32.0C~43.0°C(89.6oF~109.4°F); Object mode |
0.0~100.0°C(32.0°F-212.0°F);
Temperature unit| oc /oF
Display resolution| 0. 1 °C/0.1°F
Accuracy| ±0.2 ° C/±0.4 ° F (w i th in 35.0 ° C~42.0 ° C/95.0 ° F~107
.6°F)
Memory function| Last memory of measurement values
Power source| 2 pcs AAA alkaline battery
Automatic power- off| In 30 seconds
Main unit weight| Approx. 93 gr (batteries not included)
Main unit size| 95mm45mm155mm
Battery life| Could be used for 500 times for normal condition
Accessories| Instruction manual + storage pouch
Operating environment| Body mode 10.0°C~40.0°C/50.0 °F -104.0°F
Object mode 5°C~40.0°C/41.0°F~104.0°F
Storage environment| Temperature >-20°C~+55°C/-4.0°F ~+131.0°F Humidity: RHs
85%1 does not condense avoid crash, sunburn or rain during transportation
Warranty information
The unit is guaranteed to be free of defects in work man ship and materials under normal use for a period of 1 year from the date of purchase.
For repair under this warranty. Our authorized service agent must be advised of the fault within the period of the warranty. This warranty only covers parts and labor service under normal operations. Any defect resulting from natural causes, eg. flood, hurricane etc, is not covered in this guarantee. This guarantee also does not cover damage incurred by use of the unit not in accordance with the instructions, accidental damage, or being tampered or serviced by unauthorized service agents.
The following will be excluded from this warranty-if the thermometer has been
misused, abused, or neglect in following the manual’s instructions on purpose
and unauthorized repair or modifications.
The device requires no calibration.
The device is not repairable and contains no user serviceable parts
ShenZhen Medek Bio-Medical Co.,Ltd.
ADD: No. 101 Wenhao Industrial Park No.13 Yuanxin Road Tongle Community,
Baolong Street, Longgang District. 518116 Shenzhen P.R.China
Name:Shanghai International Holding Corp.GmbH(Europe)
Add: Eiffestrasse 80,20537 Hamburg,Germany
© copyright Edco Deutschland GmbH Siemensstr. 31 47533 Kleve
Deutschland. Made in P.R.C.
www.grundigaccessories.com
® The Grundig trademark is used under license
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>