BRAUN IRT 6030 ThermoScan Infrared Ear Thermometer User Guide
- June 6, 2024
- Braun
Table of Contents
- Product description
- How does Braun ThermoScan Infrared Ear Thermometer work?
- How to use
- Temperature taking hints
- Memory mode
- Night light feature
- Changing the temperature scale
- Care and cleaning
- Replacing the batteries
- Errors and troubleshooting
- Model and product specifications
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ThermoScan
Infrared ear thermometer
IRT 6030
This product is manufactured under license to the ‘Braun’ trademark.
‘Braun’ is a registered trademark of Braun GmbH, Kronberg, Germany.
© 2017 All rights reserved.
0297
Patents
www.kaz.com/patents/braun
Designed in Germany, Made in Mexico.
P/N: A000595R0
17 SEP 2017
Braun ThermoScan Infrared Ear Thermometer
Indications for use
The Braun ThermoScan Infrared Ear Thermometer is indicated for the
intermittent measurement and monitoring of human body temperature by consumers
in a home use environment.
Product description
- IRT 6030
- Lens Filter (Box of 20; Model: LF20)
- Probe tip
- Probe (Inserted with 1pc of lens filter)
- ExacTemp light
- Lens filter ejector
- Display
- Power button
- Start button
- Battery door
- Protective case
Proper technique is critical to obtaining accurate temperatures from this
thermometer. Therefore, read the instructions carefully and thoroughly.
The Braun ThermoScan Infrared Ear Thermometer is intended for household use
only and is not intended as a substitute for consultation with your physician.
WARNINGS AND PRECAUTIONS
- Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc. in spite of any color of the background light or absence of fever.
The operating ambient temperature range for this thermometer is 10 – 40 °C (50
– 104 °F). Do not expose the thermometer to temperature extremes (below –25 °C
/ –13 °F or over 55 °C / 131 °F) or excessive humidity (> 95 % RH). This
thermometer must only be used with genuine Braun ThermoScan lens filters
(Model LF40).
To avoid inaccurate measurements always use this thermometer with a new, clean
lens filter attached.
If the thermometer is accidentally used without a lens filter attached, clean
the lens (see «Care and cleaning» section). Keep lens filters out of reach of
children.
This thermometer is intended for household use only. This product is not
intended to diagnose any disease but is a useful screening tool for
temperature. Use of this thermometer is not intended as a substitute for
consultation with your physician.
Do not allow children to take their temperatures unattended.
Do not modify this equipment without the authorization of the manufacturer.
Parents/guardians should call the pediatrician upon noticing any unusual
sign(s) or symptom(s).
For example, a child who exhibits irritability, vomiting, diarrhea,
dehydration, seizure, changes in appetite or activity, even in the absence of
fever, or who exhibits a low temperature, may still need to receive medical
attention.
Children who are on antibiotics, analgesics, or antipyretics should not be
assessed solely on temperature readings to determine the severity of their
illness.
Please seek professional advice immediately when there is a temperature
elevation and if you are taking the temperature on:
- Neonates and infants under 3 months (consult your physician immediately if the temperature exceeds 37.4 °C or 99.4 °F)
- Patients over 60 years of age
- Patients having diabetes mellitus or a weakened immune system (e.g. HIV positive, cancer chemotherapy, chronic steroid treatment, splenectomy)
- Patients who are bedridden (e.g. nursing home patient, stroke, chronic illness, recovering from surgery)
- A transplant patient (e.g. liver, heart, lung, kidney) Fever may be blunted or even absent in elderly patients.
This thermometer contains small parts that can be swallowed or produce a choking hazard to children. Always keep the thermometer out of children’s reach.
How does Braun ThermoScan Infrared Ear Thermometer work?
Braun ThermoScan Infrared Ear Thermometer measures the infrared heat generated by the eardrum and surrounding tissues. To help avoid inaccurate temperature measurements, the probe tip is warmed to a temperature close to that of the human body. When the thermometer is placed in the ear, it continuously monitors the infrared energy. The measurement is finished and the result is displayed when the thermometer detects that a temperature measurement has been taken.
How to use
-
Remove the thermometer from the protective case.
-
Push the Power button
During an internal self-check, the display shows all segments. Then the last temperature taken will be displayed for 5 seconds. -
The lens filter indicator will blink to signal one is needed.
To achieve accurate measurements, make sure a new, clean lens filter is in place before each measurement.
Attach a new lens filter by pushing the thermometer probe straight into the lens filter inside the box and then pulling out.
Note: The thermometer will not work unless a lens filter is attached.
1. Guyton A C, Textbook of medical physiology, W.B. Saunders, Philadelphia, 1996, p 919
2. Guyton A C, Textbook of medical physiology, W.B. Saunders, Philadelphia, 1996, p 754-5
3. Netter H F, Atlas of Human Anatomy, Novartis Medical Education, East Hanover, NJ, 1997, pp 63, 95. -
Fit the probe snuggly into the ear canal, then push and release the Start button .
-
ExacTemp light will pulse while the temperature is in progress. The light will remain solid for 3 seconds to indicate that a successful temperature reading has been achieved.
NOTE: If the probe has been properly inserted into the ear canal during the measurement, a long beep will sound to signal the completed measurement.
If the probe has NOT been constantly placed in a stable position in the ear canal, a sequence of short beeps will sound, the ExacTemp light will go out and the display will show an error message (POS = position error).
See the «Errors and troubleshooting» section for more information.
-
The confirmation beep indicates that an accurate temperature measurement has been taken. The result is shown on the display.
Temperature displays. **** -
For the next measurement, press the Eject button to remove and discard the used lens filter, and put on a new, clean lens filter.
The Braun ThermoScan Infrared Ear Thermometer turns off automatically after 60 seconds of inactivityThe thermometer can also be turned off by pressing the Power button .
The display will briefly flash OFF and it will go blank.
Temperature taking hints
Always replace disposable lens filters to maintain accuracy and hygiene. The right ear measurement may differ from the measurement taken in the left ear. Therefore, always take the temperature in the same ear. The ear must be free from obstructions or excess earwax uild-up to take an accurate reading.
External factors may influence ear temperatures, including when an individual has:
Factor | Yes affects |
---|---|
Poor probe placement | |
Used lens filter | |
Dirty lens |
In the cases below, wait 20 minutes prior to taking a temperature.
Factor | Yes affects |
---|---|
Extreme hot and cold room temperature | |
Hearing aid | |
Lying on pillow |
Memory mode
The last temperature taken is stored in its memory and will be automatically displayed for 5 seconds when it is turned on again.
Night light feature
The thermometer includes a convenient night light to illuminate the display in
a dim environment.
The light will turn on when you press any button. It will stay on until the
thermometer is inactive for up to 15 seconds even after the temperature is
taken.
Changing the temperature scale
This thermometer is shipped with the Celsius (° C) temperature scale activated. If you wish to switch to Fahrenheit (° F) and/or back from Fahrenheit to Celsius, proceed as follows:
- Make sure the thermometer is turned off.
- Press and hold down the Power button . After about 3 seconds the display will show this sequence: ° C / SET / ° F / SET …
- Release the Power button when the desired temperature scale is shown.
There will be a short beep to confirm the new setting, then the thermometer is turned off automatically.
Care and cleaning
The probe tip is the most delicate part of the thermometer.
It must be clean and intact to ensure accurate readings.
If the thermometer is ever accidentally used without a lens filter, clean the
probe tip as follows:
Very gently wipe the surface with a cotton swab or soft cloth moistened with
alcohol. After the alcohol has completely dried out, you can put a new lens
filter on and take a temperature measurement.
If the probe tip is damaged, please contact the local service center.
Use a soft, dry cloth to clean the thermometer display and exterior. Do not
use abrasive cleaners. Never submerge this thermometer in water or any other
liquid. Store thermometer and lens filters in a dry location free from dust
and contamination and away from direct sunlight.
Replacing the batteries
The thermometer is supplied with two 1.5 V type AA (LR 06) batteries.
- Insert new batteries when the battery symbol appears on the display.
- Open the battery compartment. Remove the batteries and replace them with new batteries, making sure the poles are in the right direction.
- Snap battery door into place.
Only discard empty batteries. To protect the environment, dispose of empty batteries at your retail store or at appropriate collection sites according to national or local regulations.
The thermometer is initially calibrated at the time of manufacture. If this
thermometer is used according to the use instructions, periodic re-adjustment
is not required. If at any time you question the accuracy of the temperature
measurement, please contact your authorized service center.
The manufacturing date is given by the LOT number located in the battery
compartment.
The first three (3) digits after LOT represent the Julian date that the
product was manufactured and the next two (2) digits represent the last two
numbers of the calendar year the product was manufactured. The last
identifiers are the letters that represent the manufacturer.
An example: LOT 11614K, this product has been manufactured on the 116th day of
the year 2014.
Errors and troubleshooting
Error Message | Situation | Solution |
---|---|---|
No lens filter is attached. | Attach a new, clean lens filter. | |
The thermometer probe was not |
positioned securely in the ear.
An accurate measurement was not possible.
POS = position error| Take care that the positioning of the
the probe is correct and remains stable.
Replace lens filter and reposition.
Press the Start button to begin a new
measurement.
| Ambient temperature is not
within
the allowed operating range
(10 – 40 °C or 50 – 104 °F).| Allow the thermometer to remain for
30 minutes in a room where
the temperature is between 10
and 40 °C or 50 and 104 °F.
| Temperature taken is not within
typical human temperature range
(34 – 42.2 °C or 93.2 – 108 °F).
HI = too high
LO = too low| Make sure the probe tip and lens are
clean and a new, clean lens filter is
attached. Make sure the thermometer is properly inserted. Then, take a new
temperature.
| System error – self-check display flashes continuously and will not be
followed by
the ready beep and the ready symbol.
If the error persists,
If the error still persists,| Wait 1 minute until the thermometer
turns off automatically, then turn
on again.
… reset the thermometer by re-moving
the batteries and putting them back in.
… please contact the service center.
| The battery is low, but the thermometer will still operate correctly.|
Insert new batteries.
| The battery is too low to take correct
temperature measurement.| Insert new batteries.
Model and product specifications
Product specifications
Product | ThermoScan IRT 6030 |
---|---|
Temperature measurement within seconds | ■ |
Temperature range °C | 34-42.2 |
Temperature range °F | 93.2-108.0 |
ExacTemp technology | ■ |
Feedback system | ■ |
Ready beep | ■ |
Small, soft tip | ■ |
Flexible tip | ■ |
Memory storage capacity | 1 |
Auto-off after | 60 sec. |
Easy-to-read LCD display | ■ |
Lens filter detector | ■ |
Lens filter ejector | ■ |
Protective case with lens filter storage | ■ |
Batteries included | ■ |
21 lens filter included | ■ |
Colour | Green |
Displayed temperature range: | 34 – 42.2 °C |
--- | --- |
Operating ambient temperature range: | 10 – 40 °C |
Storage temperature range: | -25 – 55 °C |
Operating and storage relative humidity: | 10 – 95 %RH (non condensing) |
Display resolution: | 0.1 °C or °F |
Accuracy for displayed temperature range | Maximum Laboratory Error |
--- | --- |
35 °C – 42 °C (95 °F – 107.6 °F): | ± 0.2 °C |
outside this range: | ± 0.3 °C |
clinical repeatability: | ± 0.2 °C |
Battery life: | 2 years / 350 measurements |
Service life: | 5 years |
This thermometer is specified to operate at 1 atmospheric pressure or at altitudes with an atmospheric pressure up to 1 atmospheric pressure (700-1060hPa).
Please do not dispose of the product in the household waste at the end of it
useful life.
To protect the environment, dispose of empty batteries at appropriate
collection sites according to national or local regulations.
Manufactured by Key Tronic Corporation (Address: Tomas Becket #2220 Parque Ind. Gema Plant 3 Juarez, Chihuahua C.P. 32380 Mexico) for Kaz Europe Sarl (Address: Place Chauderon 18, CH-1003 Lausanne, Switzerland)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>