Harley Benton StompControl-4 ISO Programmable Loop Switcher with Integrated Power Supply User Guide
- June 6, 2024
- Harley Benton
Table of Contents
Quick Start Guide
This quick start guide contains important information on the safe operation of the product. Read and follow the safety advices and instructions given. Retain the quick start guide for future reference. If you pass the product on to others please include this quick start guide.
Safety instructions
Intended use
This unit serves as a control unit for up to 4 external effects units. Any
other use or use under other operating conditions is considered to be improper
and may result in personal injury or property damage. No liability will be
assumed for damages resulting from improper use.
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not
within reach of babies and young children. Choking hazard! Ensure that
children do not detach any small parts from the product. They could swallow
the pieces and choke! Never let children unattended use electrical devices.
Where to use the product
Never use the product
- in conditions of extreme temperature or humidity
- in extremely dusty or dirty areas
- at locations where the unit can become wet
General handling
- To prevent damage, never use force when handling the product.
- Never immerse the product in water. Just wipe it with a clean dry cloth. Do not use liquid cleaners such as benzene, thinners or flammable cleaning agents.
- Disconnect the device’s power supply from the mains when not in use.
Features
- 4 external effects units for guitar / bass can be connected
- 20 programmable groups
- 4 LEDs and one LED display indicate the device functions
- Built-in power supply for the external devices
- True bypass for unaffected signal transmission
- Protection against overload and short circuit
- Aluminium housing
- Supplied with mains adapter and 5 × power supply cable, á 60 cm
Controls and functions
1 | LED display for displaying the current loop group |
---|---|
2 | STORE button to save the selected configuration |
3 | EDIT button to change the current configuration |
4 | LEDs for displaying the currently activated loop 1 – 4 |
5 | MUTE button to mute the signal while tuning |
6 | ABCD buttons for activating loops 1 – 4 |
7 | BANK + button to recall loop groups 1 – 5 |
8 | Input IN to connect the instrument |
9 | TUNER output for connecting an external tuner |
10 | L1 – L4 SENDS to the effect devices |
11 | L1 – L4 RETURNS from the effect units |
12 | 9 V outputs (100, 300, 500 mA) to power the effects units |
13 | Output OUT to connect an amplifier or the PA |
14 | 12 V connection for the power supply of the device (centre negative) |
Using the device
Connecting
Connect the instrument to the 1/4″ jack input 8
. Connect up to 4 effects
units to socket pairs L1 – L4. Connect the jack to the respective input of the
effects unit and the jack to its output. If you want to supply the effect
devices and / or a tuner via the StompControl with a voltage of 9 V , connect
their sockets to the power supply with the connections 12
. Pay attention to
the differences in the maximum current provided by the connections: The
connections at Tuner and L1 can be loaded by up to 100 mA each, the
connections at L2 and L3 by up to 300 mA each and the connection at L4 by up
to 500 mA. You can connect an external tuner to the tuner output 9
. Connect
the output OUT 13
to a suitable amplifier or the PA. Connect the supplied AC
adapter to the 12 V connector 14
and plug the adapter into a power outlet.
The device is instantly ready to use in True Bypass mode and the LEDs are
flashing.
Operating
Press the switches A, B, C, D, 6
to switch the effects units connected to L4
– L1 into the signal path. The LEDs 4
indicate the status of the 4 loops. If
the loop is active, the LED is lit, otherwise not. The various configurations
can be stored in up to 5 loop groups. The LED display 1
indicates the
current loop group. Press BANK 7
repeatedly to select the desired loop
group, then press STORE 2
to save. Press BANK (u) again to call up another
loop group. If you press EDIT3
you can change the configuration of this
loop. Then press STORE 2
again to save the changes. To mute the signal, for
example while tuning, press MUTE 5
. Press MUTE again, to cancel muting.
Technical specifications
Supply voltage power adapter: 230 V ~ 50 Hz
Supply voltage unit: 12 V / 2 A
Power supply for connected devices:
2 × 9 V 100 mA
2 × 9 V 300 mA
1 × 9 V 500 mA
Dimensions (W × H × D) : 335 mm × 75 mm × 45 mm
Weight: ca. 700 g
For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the notes and markings on the packaging.
This product is subject to the European Waste Electrical and Electronic Equipment Directive (WEEE) in its currently valid version. Do not dispose of your old device with your normal household waste. Dispose of this product through an approved waste disposal firm or through your local waste facility. Comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility.
Thomann GmbH · Hans-Thomann-Straße 1 · 96138 Burgebrach · www.thomann.de · info@thomann.de DocID: 451027_05.01.2021
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>