Wzzard™ Mesh Wireless Sensor
Monitoring Nodes – Commercial Applications

Features

  • Ultra-low-power 802.15.4e SmartMesh IP technology
  • Communicates with SmartSwarm 342 gateway via a highly scalable and reliable wireless mesh network
  • Internal temperature & humidity sensing support
  • Connect to industry standard analog or digital sensors
  • MQTT and JSON IoT protocol to application platform
  • Wide operating temperature range
  • Monitor refrigeration, food processing/storage, or light stacks

Introduction

Wireless Connectivity Where You Need It
The Wzzard mesh intelligent wireless sensor platform creates a complete, quick and easy connectivity stack between your sensors and your application, on your network or on the Internet. The platform uses Wzzard mesh wireless sensor nodes and a wireless 802.15.4e SmartMesh IP network to transmit sensor data to the gateway. The SmartSwarm 342 gateway connects to the Internet via wired connections or cellular data networks.
Reliable, Highly Scalable Wireless Network
The Wzzard Mesh platform uses mesh networking and time-synchronized channel hopping to provide up to 99.999% connectivity, even in demanding RF environments. New nodes may be added at any time ­ the SmartMesh IP network will dynamically self-configure as nodes are added or removed. This is a function of the mesh network itself and does not need to be controlled by the network gateway. One gateway can support up to 100 nodes.
Easy Installation and Configuration
Non-intrusive – even portable – network “overlay” is easy to install and remove with no disruptions to your existing network and no downtime. Configuration of the Wzzard mesh sensor platform is easy via the Advantech hub cloud management portal.

Ordering Information

Model No.

|

Description

---|---
BB-WCD1H2102H| Wzzard Mesh Wireless 802.15.4e Sensor Node
– HVAC/Cooler Node for Temperature & Humidity Sensing
– 2 AI, 1 DI, 1 Thermistor, Internal Temperature & Humidity, Internal Antenna
BB-WCD1H3001HP100| Wzzard Mesh Wireless 802.15.4e Sensor Node
– Commercial Stack light Node for Light Sensing
– 3 AI, vBat Out, Internal Antenna
– Internal Temperature & Humidity supported

Accessories ­ Sold Separately ­
Or included with select Wzzard starter kits (see kit/s below for details)
BB-WCHMS ­ Door sensor cable (open/close)
BB-WCHCBL ­ Thermistor/Breakout sensor cable
BB-LSSCBL ­ Light sensor cable (stack light)
BB-JC10F50V ­ 50A clamp-on current sensor (compressor, fan)

Dimensions

ADVANTECH BB-WCD1H2102H Wzzard Mesh Wireless Sensor Monitoring Nodes -
Dimensions

Starter Kits Available

Everything you need to get started ­ easy to expand later.

ADVANTECH BB-WCD1H2102H Wzzard Mesh Wireless Sensor Monitoring Nodes -
icon

Refrigeration/Cooler Monitoring
Model# BB-WSK-REF-2
1 – Wzzard wireless node – temperature & humidity (# BB-WCD1H2102H)
2 – Clamp-on current sensors (# BB-JC10F50V)
1 – 10K thermistor for temperature (# BB-WCHCBL)
1 – Door open/close sensor (# BB-WCHMS)
1 – SmartSwarm 342 Gateway

ADVANTECH BB-WCD1H2102H Wzzard Mesh Wireless Sensor Monitoring Nodes -
fig1 Stack Light Monitoring
Model# BB-WSK-SLM-2
1 – Wzzard wireless node – light (# BB-WCD1H3001HP100)
1 – Stack Light Sensor Cable (# BB-LSSCBL) 1 – SmartSwarm 342 Gateway

ADVANTECH BB-WCD1H2102H Wzzard Mesh Wireless Sensor Monitoring Nodes -
fig2
BB-USOPTL4-2P_BB-USOPTL4-4P_0221ds BB-WCD1Hxx_WzzardCommercialNodes_1321ds Some names and phrases are trademarks and property of their respective owners.

Specifications

Technology


Wireless| 802.15.4e, SmartMesh IP
LED| Network Connectivity, Node Status

Power

Internal| 3.6V 1650 mAH Lithium Thionyl Chloride 2/3 AA battery
Battery Life| 5-year battery life, based on the 1-minute sensor sampling interval

Mechanical

Physical Connection| Molex® 6-pin MicroClasp™
Antenna| Internal
Mounting Options| Mounting bracket (included), VHB adhesive strip (included),

or zip tie (ties not included)

Dimensions| 120.38l x 27.42h x 19.05d mm  (4.74l x 1.08h x 0.75d in)
Weight| 0.09 kg  (0.2 lb)

Wireless Security

Device Authentication
128-bit AES-based encryption with multiple keys
Message Integrity Check (MIC)
Synchronized Key Changeovers
Customized Key Rotation

*Thionyl Chloride Lithium Battery  (1 supplied with the product)**

Temperature Range| -60 to +85 °C
Nominal Capacity| 1.65 Ah
Nominal Voltage| 3.6 V
Diameter| 14.5 mm
Height| 33.5 mm
   *Potential Hazard: Do not recharge, crush, disassemble or heat above +100°C (+212°F)

Environmental

Installation| Indoor
Operating Temperature| -20 to +70 °C (-4 to +158 °F)
Storage Temperature| -40 to +85 °C (-40 to +187 °F)
Operating Humidity| 0 to 95%, non-condensing

Regulatory – Approvals / Standards / Directives

FCC Part 15, 15.247, Class B Industry Canada – RSS210


CE – Directives| 2014/35/EU Low Voltage Directive
2014/53/EU Radio Equipment Directive
2011/65/EU amended by (EU) 2015/863 – Reduction of Hazardous Substances Directive (RoHS)
2012/19/EU Waste Electrical and Electronic Equipment (WEE)
CE – Standards| EMC:
ETSI EN 300 328 v2.1.1 – EMC & Radio Spectrum Matters (ERM) Wideband Transmission Systems, 2.4 GHz ISM Band
ETSI EN 301 489-1 V2.1.1 – Applied in accordance with the specific requirements of:
ETSI EN 301 489-17 V3.2.0 – EMC and Radio Spectrum Matters: Broadband Data Sytems
EN 55032 +AC, Class A Information technology equipment — RF Emissions EN 55024 Information Technology Equipment — Immunity Characteristics — Limits and methods of measurement
Safety:
EN/IEC 61010-1 3rd Ed. Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements
EN/IEC 61010-2-201 1st Ed. Particular requirements for control equipment
RF Exposure:
EN 62479 – Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Standards – other| EN 61000-6-2 – Generic Immunity Standard for (Heavy) Industrial Environments
EN 61000-6-4 + Al – Emission Standard for (Heavy) Industrial Environments
EN 60255-21-1 – Vibration, 2g, 10-500 Hz,1.5mm displacement
EN 60255-21-2 – Shock, 50g, LLMs half-sine wave, 18 shocks
IEC 60068-2-31 – Drop

SmartMesh IP 802.15.4e Radio Specifications

Parameter| Conditions| Minimum| Typical| Maximum|

Units

---|---|---|---|---|---
Frequency Band| | 2.400| | 2.4835| GHz
Number of Channels| | | 15| |
Channel Separation| | | 5| | MHz
Channel Clear Frequency| Where k =11 to 25, as defined by IEEE 802.4.15| | 2405 + 5*(k-11)| | MHz
Modulation| IEEE 802.15.4 Direct Sequence Spread Spectrum (DSSS)| | | |
Raw Data Rate| | | 250| | kbps
Range| Indoor| | 100| | m
Outdoor| | 200| | m
Receiver Sensitivity| Packet Data Error Rate (PER) = 1%| | | -93| dBm
Receiver Sensitivity| PER = 50%| | | -95| dBm
Conducted Output Power (PA on)| Delivered to a 50 Q load| | 8| | dBm
Conducted Output Power (PA off)| Delivered to a 50 Q load| | 0| | dBm
Radiated Output Power (PA on)| Taoglas PA.11.BB antenna| | 7| | dBm
Radiated Output Power (PA off)| Taoglas PA.11.BB antenna| | -1| | dBm

BB-WCD1H2102H – Sensor Interface Specifications

Analog Inputs

Input Range| 0 -10V DC / 0-20 mA (software selectable)
Resolution| 0.3 mV/ 1.3 uA
Input Load Resistance| 59 K Ohms / 250 Ohms
Accuracy| +/-25 mV +/-0.05 mA
Number of Analog Inputs| 2
Thermistor Input
Types Supported| 10K CO +25 °C
Ranges Supported| -40 to +85 °C
Resolution| 0.05 °C
Accuracy| Typical ± 0.3 °C it +25 °C
Number of Thermistor Inputs| 1
Digital Inputs
Voltage Range| 0 – 48V DC
V IL| 0.4 V, maximum
V IH| 2.5 V, minimum
Pull-up Current| 65 IA
Type| Sinking (NPN) Input
Isolation| None
Number of Digital Inputs| 1
Integrated Sensors – inside of the node
Humidity Sensor
Accuracy| 4%, relative humidity
Response Time| 80% response within 10 minutes
Number of Humidity Sensors| 1
Temperature Sensor| Conditions| Minimum| Typical| Maximum| Units
---|---|---|---|---|---
Offset| Temperature Offset Error @ +25 °C| | ± 0.25| | °C
Slope Error| | | ± 0.033| | °C / °C

BB-WCD1H3001HP100 – Sensor Interface Specifications

Analog Inputs


Input Range| 0 -10 VDC
Resolution| 0.3 mV
Input Load Resistance| 59 K Ohms
Accuracy| -11-25 mV
Number of Inputs| 3

Sensor Power

Power to Sensor| Switched vBat Out

Integrated Sensors – inside of node

Humidity Sensor


Accuracy| 4% RH
Response Time| 80% response within 10 minutes

ADVANTECH logo

www.advantech.com
All product specifications are subject to change without notice.
BB-USOPTL4-2P_BB-USOPTL4-4P_0221ds
BB-WCD1Hxx_WzzardCommercialNodes_1321ds
Some names and phrases are trademarks and property of their respective owners.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals